Page 3

This agreement shall be interpreted in accordance with the laws of the State of Michigan and jurisdiction and venue shall lie with the courts of Michigan as selected by X-Rite, Incorporated...

Page 4

As the DTP34 QuickCal Densitometer is designed to be a drop-in replacement for the DTP32 Automatic Strip Reading Densitometer, reflection versions, it will by default report itself as a DTP32... Most existing software packages will reference a DTP32 in their connection menu while newer software may use DTP34... Select DTP34 if it is available, otherwise select the DTP32... Refer to Appendix B for further differences... See the Readme file on the CD for any late changes or known issues...

Page 5

Instrument Interface The Quick Cal Densitometer must be interfaced directly with one of the computers Serial Ports... Installation differs slightly for Macs and PCs (see below)... For attachment to a Mac Mini-DIN 8 Serial Port, you need to use the optional adapter (P/N SE108-DB9PA-01)...

Page 6

NOTE: When the instrument is first turned on the LED will be red while it performs its self-tests... The self- tests will complete in approximately 2 to 3 seconds, at which time it will turn green under normal conditions...

Page 7

Frequency of Calibration Your QuickCal Densitometer should have a Quick Calibration performed weekly... A Full Calibration should be performed annually, during heavy usage to provide accurate measurements, or if the Quick Calibration consistently fails... Typically, the host computer prompts for an instrument calibration (amber LED) when required but the process can be invoked manually at any time... Refer to the following procedure for details on the calibration process...

Page 8

The strip must have at least a 1... 2 (30... 5mm) leader before the leading edge of the first step... Contact X-Rite Applications Support if additional information is required... Inspect the strip for spots or defects on the steps... Defects may cause inaccurate measurements...

Page 9

Some software packages define strips as multi-pass where all color passes must be read before a conformation is displayed on the monitor... In these cases, a successful reading of a color pass is shown by the instrument slowly flashing green after the reading... This indicates that you may continue to the next color pass... Fast flashing of green indicates a re-read is required on the pass... The instruments LEDs will stay at solid green after all passes are successfully read...

Page 10

Spot Measurement Your QuickCal Densitometer is designed to read spots, single readings of specific locations... This feature can be manually activated or if supported, activated by your software application... Refer to your software program documentation to see if this feature is supported... To manually activate this feature, scan the Spot Read X-Rite Setup Barcode enclosed...

Page 11

Troubleshooting and Service Troubleshooting Prior to contacting X-Rite, Inc... Customer Service for instrument problems try the applicable solution(s) described below... If the condition persists contact a Customer Service Representative (see Service Information)...

Page 12

X-Rite will repair any instrument past warranty... The customer shall pay shipping and repair cost to the authorized service center, and the instrument shall be submitted in the original carton, as a complete unaltered unit along with all the supplied accessories...

Page 13

General Maintenance Cleaning the Instrument Your instrument requires very little maintenance to achieve years of reliable operation... However, to protect your investment and maintain reading accuracy, a few simple-cleaning procedures should be performed from time to time...

Page 14

If required, a new calibration reference can be ordered from X-Rite... Order calibration reference part number DTP34-100-KIT...

Page 15

Patch Size: ... 400 (10... 16 mm) min... in direction of travel by ... 350 (9 mm) min... wide... 1 mm wide 1... 0D contrast space between patches or ... 5D min difference between patches...

Page 16

For the most recent list of supporting third-party software, see X-RiteColor Enabled Partner literature item L11-031A and L11-031B, or visit www... x-rite... com/support/partners... asp and browse to the Support and Training page...

Page 17

Configuration of the instrument Go to page 3 to Configure the Instrument Most software will automatically configure and setup the DTP32R or the DTP34 for use... Often, this equates to selecting from various communications settings so the software can take over control of the instrument once it is connected... For the few packages that require a manual configuration the DTP34 allows manual configuration by reading X-Rite Set-up Barcodes... X-Rite Set-up Barcode pages are supplied on the QuickCal CD-ROM for some manual configurations... Check the third party support folder on the CD-ROM to see if there is a configuration page that contains all the settings for your software package... More information about reading bar codes is found in section 2 of the manual... Further information about Quick Cal and third party support can be referenced at the X-Rite website under the help desk area at the following location: http://www... xrite... com/HelpDesk/3PSort... asp?RecType=6&id=272

Page 18

The LEDs signal the status of the instrument when reading a set-up barcode... While scanning the initial barcode, the LEDs will flash slowly between off and green, the same as any normal scan... Once the unit has recognized the initial barcode as being part of a set-up barcode, the LEDs will slowly flash between yellow and green... This same flash pattern will continue while scanning continuation barcodes... Upon completion of the entire set-up barcode, the LEDs will come on steady green, indicating a successful completion...

Page 28

X-Rite, Incorporated - World Headquarters 3100 44th Street S... W... Grandville, Michigan 49418 USA www... x-rite... com (616) 534-7663 Toll-Free U... S... Numbers Tel: 1-888-826-3044 Fax: 1-888-826-3045 Toll-Free International Numbers Tel: 1-888-826-3039 Fax: 1-888-826-3041

Manualsnet FAQs

If you want to find out how the X-RiteColor DTP34 Xerox works, you can view and download the Xerox X-RiteColor DTP34 Densitometer Users Manual on the Manualsnet website.

Yes, we have the User's Manual for Xerox X-RiteColor DTP34 as well as other Xerox manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The User's Manual should include all the details that are needed to use a Xerox X-RiteColor DTP34. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Xerox X-RiteColor DTP34 Densitometer Users Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Xerox X-RiteColor DTP34 Densitometer Users Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Xerox X-RiteColor DTP34 Densitometer Users Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Xerox X-RiteColor DTP34 Densitometer Users Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Xerox X-RiteColor DTP34 Densitometer Users Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.