Viking VCRT301 Rangetop Installation Guide PDF
Summary of Content for Viking VCRT301 Rangetop Installation Guide PDF
Viking Installation Guide
Electric Induction Rangetops
Viking Range Corporation
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
For product information,
call 1-888-VIKING1 (845-4641)
or visit the Viking Web site at
vikingrange.com
F20115A (PS032607JJ)
1
Before beginning, please read and follow these instructions completely and carefully.
Do not remove permanently affixed labels, warnings, or plates from product. This may void the warranty.
Please observe all local and national codes and ordinances.
Please ensure that this product is properly grounded.
Installation must conform with local codes, or in the absence of codes, with the National Electrical Code, ANSI/NFPA 70, latest edition.
In CANADA: Electrical installation must be in accordance with the current CSA C22.2 Canadian Electrical Codes Part 1 and/or local codes.
Installer should leave these instructions with the consumer who should retain for local Inspectors use and for future reference.
Consumer should retain this guide for the local Electrical Inspectors use.
IMPORTANT Please Read and Follow! General Information
2
All openings in the wall behind the appliance and/or in the floor under the appliance should be sealed.
Keep appliance area clear and free from combustible materials, gasoline and other flammable vapors.
Disconnect the electrical supply prior to servicing and/or cleaning.
When removing the appliance for service and/or cleaning, disconnect AC power supply and carefully remove the appliance by pulling forward.
Electrical requirements are listed in the product specifications chart. Electrical installation should comply with national and local codes.
DO NOT remove protective packaging until you are ready to perform the installation.
Back Trim Accessories Assembly and installation instructions are included with all back trim accessories.
W A R N I N G ELECTRICAL GROUNDING
INSTRUCTIONS This appliance must be electrically in accordance with local codes, or in the absence of local codes, the National Electrical ANSI/NFPA 70, latest edition.
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY
GROUNDED.
W A R N I N G The use of cabinets for storage above the appliance may result in potential fire or burn hazard. Combustible items may ignite, metallic items may become hot and cause burns. If a cabinet storage is to be provided, the risk can be reduced by installing a rangehood that projects horizontally a minimum of 5 (12.7 cm) beyond the bottom of the cabinets.
Electrical Requirements Check your national and local codes regarding this unit. This rangetop is supplied with a 3 wire, 240/208 VAC, 60 Hz conduit which is equipped with a No. 10 ground wire. See electrical connection section for grounding instructions. This unit should be fused separately.
C A U T I O N Be sure all electrical power is off between the breaker box and the junction box, until the unit is installed and ready to operate. The junction box should be connected to a suitable ground.
Electrical Connection
When making the wire connections, use the entire length of the conduit provided (3 feet). The conduit must not be cut. Connect the red and black leads from the unit conduit to the corresponding leads in the junction box. The bare ground wire in the conduit is connected to the unit frame. When connecting to a 3- conductor branch circuit, if local codes permit, connect the bare ground connector lead of the unit to the branch circuit neutral (gray or white in color).
DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE. SUCH USE MAY RESULT IN A FIRE, ELECTRICAL SHOCK OR OTHER PERSONAL INJURY.
W A R N I N G This appliance should not be used for space heating. This information is based on safety considerations.
W A R N I N G Electrical power to the unit must be shut off while line connections are being made. Failure to do so could result in serious injury or death.
Dimensions & Specifications
Induction/Radiant Rangetop Description VCRT301 VCRT361 Overall Width 29 7/8 (75.9 cm) 35 7/8 (91.1 cm) Overall Height From Bottom
BASE HEIGHT ADDITIONS TO BASE HEIGHT To top of glass frame To top of island trim - add 1 1/4 (3.2 cm) 7 7/8 (20.0 cm) To top of backguard - add 6 (15.2 cm)
To top of high-shelf - add 23 1/2 (59.7 cm)
Overall Depth From Rear
To edge of side panel - 24 (61.0 cm) To end of control panel - 25 15/16 (65.9 cm)
To end of knobs - 27 7/16 (69.7 cm)
Cutout Width 30 (76.2 cm) 36 (91.4 cm)
Cutout Height 7 1/2 (19.1 cm)
Cutout Depth 24 (61.0 cm)
Electrical Requirements
3 - Wire, 240/208 VAC, 60 Hz, electrical connection. Unit is equipped with No. 10 ground wire in conduit. Should be fused separately.
Maximum Amps 240v - 37.9 amps 208v - 32.8 amps
240v - 55.0 amps 208v - 50.2 amps
Surface Element Rating
240V 208V 240V 208V
Left Front 2500 watts 1875 watts Left Front 2200 watts 1650 watts Left Rear 1500 watts 1125 watts Left Rear 1500 watts 1125 watts
Center Front 1800 watts 1350 watts Bridge 800 watts 600 watts Center Rear 1800 watts 1350 watts
Right Front 1200 watts 900 watts Right Front 1200 watts 900 watts Right Rear 3300 watts 2475 watts Right Rear 3300 watts 2475 watts
Approx. Shipping Wt. 110 lbs. (49.5 kg) 125 lbs. (56.2 kg)
Dimensions & Specifications
3 4
All Induction Rangetop Description VIRT301 VIRT361 Overall Width 29 7/8 (75.9 cm) 35 7/8 (91.1 cm) Overall Height From Bottom
BASE HEIGHT ADDITIONS TO BASE HEIGHT To top of glass frame To top of island trim - add 1 1/4 (3.2 cm) 7 7/8 (20.0 cm) To top of backguard - add 6 (15.2 cm)
To top of high-shelf - add 23 1/2 (59.7 cm)
Overall Depth From Rear
To edge of side panel - 24 (61.0 cm) To end of control panel - 25 15/16 (65.9 cm)
To end of knobs - 27 7/16 (69.7 cm)
Cutout Width 30 (76.2 cm) 36 (91.4 cm)
Cutout Height 7 1/2 (19.1 cm)
Cutout Depth 24 (61.0 cm)
Electrical Requirements
3 - Wire, 240/208 VAC, 60 Hz, electrical connection. Unit is equipped with No. 10 ground wire in conduit. Should be fused separately.
Maximum Amps 240v - 37.9 amps 208v - 32.8 amps
240v - 56.3 amps 208v - 56.3 amps
Surface Element Rating
240V 208V 240V 208V
Left Front 2500 watts 1875 watts Left Front 2700 watts 2025 watts Left Rear 1500 watts 1125 watts Left Rear 1800 watts 1350 watts
Center Front 2700 watts 2025 watts Center Rear 1800 watts 1350 watts
Right Front 1200 watts 900 watts Right Front 1200 watts 900 watts Right Rear 3300 watts 2475 watts Right Rear 3300 watts 2475 watts
Approx. Shipping Wt. 110 lbs. (49.5 kg) 125 lbs. (56.2 kg)
Minimum Clearance from adjacent combustible construction Cooking surfaces and below (36 [91.4 cm] and below)
Sides - 0 Rear - 0 with backguard or highshelf; 0 with island trim and non-combustible wall; 6 (15.2 cm) with
island trim and combustible rear wall Top grate support - 36 (91.4 cm)
Above cooking surface (above 36 [91.4 cm]) Sides - 6 (15.2 cm) Within 6 (15.2 cm) side clearance, wall cabinets no deeper than 13 (33.0 cm) must be minimum 18 (45.7 cm) above cooking surface.
Wall cabinets directly above product must be minimum 36 (91.4 cm) above cooking surface.
Interior Cabinet Clearances for proper airflow
Remove the material from this area for proper air flow into the unit.
3 (7.6 cm)
2 (5.1 cm)
2 3/4 (7.0 cm)
8 (20.3 cm)
8 (20.3 cm)
3 (7.6 cm)1 1/2 (3.8 cm)
1 1/2 dia. cutout for conduit
IMPORTANT: The electronic components for the induction elements in the rangetop need some air circulation. To ensure long life of electronic components, it is required that a minimum of 8 (20.3 cm) of open space remain between the bottom of the unit and any shelf underneath. The maximum length of the shelf underneath is to be 18 (45.7 cm) There should be no partition or shelf directly underneath the unit.
8 Min. (20.3 cm)
18 Max. (45.7 cm)
6
Proximity to cabinet installation 1. This rangetop may be installed directly adjacent to existing 36 (91.4 cm) high base cabinets.
2. The rangetop CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above 36 (91.4 cm) high. There must be a minimum of 6 (15.2 cm) side clearance from the rangetop to such combustible surfaces above the 36 (91.4 cm) counter height.
3. Within the 6 (15.2 cm) side clearance to combustible vertical surfaces above 36 (91.4 cm), the maximum wall cabinet depth must be 13 (33.0 cm) and wall cabinets within this 6 (15.2 cm) side clearance must be 18 (45.7 cm) above the 36 (91.4 cm) high countertop.
4. Wall cabinets above the rangetop must be a minimum of 36 (91.4 cm) above the rangetop cooking surface for the full width of the rangetop.
13 Max
(33.0 cm)
36 Min. (91.4 cm)
7 1/2 (19.1 cm)
18 Min. (45.7 cm)6 Min.
(15.2 cm)
36 Min. (91.4 cm)
SIDE FRONT
5
Installation Clearances
Detailed View of Bottom Support
87
1. The interior of the oven should be washed thoroughly with hot, soapy water to remove film residues and installation debris before being used for food preparation, then rinsed and wiped dry. Solutions stronger than soapy water are rarely needed.
2. Some stainless steel parts may have a plastic protective wrap, which must be removed. All stainless steel body parts should be washed with hot soapy water and with liquid cleaner designed for this material. If build-up occurs, do not use steel wool, abrasive cloths, cleaners or powders! If it is necessary to scrape stainless steel to remove encrusted materials, soak with hot, wet cloths to loosen the material, then use a wood or nylon scraper. Do not use a metal knife, spatula, or any other metal tool to scrape stainless steel!! Scratches are almost impossible to remove.
Service & Parts Only authorized replacement parts may be used in performing service on the appliance. Do not repair or replace any part of the appliance unless specifically recommended in the manual. All other servicing should be referred to a qualified technician.
Contact Viking Range Corporation, (888) 845-4641, for the nearest service parts distributor in your area.
Record the following information indicated below. You will need it if service is ever required. The serial number and model number for your appliance are located on the identification plate mounted on the inside of the water tank opening.
Model number _________________________________________
Serial number _________________________________________
Date of purchase _________________________________________
Date installed _________________________________________
Dealer's name _________________________________________
Address _________________________________________
These installation instructions should remain with the unit for future reference.
Final Preparation
109
Electric All Induction 30 Wide Rangetop Wiring Diagram
POWER BOARD
JOUT1
JOUT2 SMALL COIL
J3 TEMP CONTROL
J14
J15
J11
J10
LED BOARD
FRONT
REAR
LARGE COIL JOUT3
JOUT4
J2
J12
J13
TEMP CONTROL
RED
BLACK
RED
BLACK
AC FAN
J16
J17
J6
J7
J4 J5
J18
J19
JE5
JE6
JE4JE3
JE8JE7
JE1
JE2
EMI BOARD
LEFT
SMALL COIL POTENTIOMETER
LARGE COIL POTENTIOMETER
J9
J8
RED
BLACK
BLACK
RED
VIO
GRAY
SECTION
BLUE
WHITE POWER LINE
CONDITIONER J1
L1C L2R
L2
L1
RED
BLACK GREEN
CHASSIS GROUND
J2
L1RL2C
J4 J3
POWER BOARD
JOUT1
JOUT2 SMALL COIL
J3 TEMP CONTROL
J14
J15
J11
J10
LED BOARD
FRONT
REAR
LARGE COIL JOUT3
JOUT4
J2
J12
J13
TEMP CONTROL
RED
BLACK
RED
BLACK
AC FAN
J16
J17
J6
J7
J4 J5
J18
J19
JE5
JE6
JE4JE3
JE8JE7
JE1
JE2
EMI BOARD
RIGHT
SMALL COIL POTENTIOMETER
LARGE COIL POTENTIOMETER
J9
J8
RED
BLACK
BLACK
RED
VIO
GRAY
SECTION
BROWN
ORG
C A U T I O N Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
W A R N I N G This unit must be properly grounded. See installation instructions for proper grounding instructions. NOTE: Trailers or stripes will be the second color in a color combination.
1211
Electric Induction/Radiant 30 Wide Rangetop Wiring Diagram
2500/1000 WATT L. F. ELEM.
1500 WATT L.R. ELEM.
RED/YEL
B LK
/W H
BLK
YEL/BLK
WH/BLK
B LK
RED
RED/BLK
YEL/RED
WH/RED
RE D
/B LK
ORG
YEL/RED
YEL/BLK
WH/BLK
RED
WH/RED
RED/BLK
RED/BLKRED/BLK
RED
ORG
ORG
POWER BOARD
AC FAN
J16
J17
J6
J7
J4
J5
J18
J19
POWER LINE CONDITIONER
J1
L1C L2R
ORG
BROWN
J2
L1RL2C
J4 J3
JOUT1
JOUT2 SMALL COIL
J3 TEMP CONTROL
J14
J15
J11
J10
LED BOARD
FRONT
REAR
LARGE COIL JOUT3
JOUT4
J2
J12
J13
TEMP CONTROL
SMALL COIL POTENTIOMETER
LARGE COIL POTENTIOMETER
J9
J8
JE5
JE6
JE4JE3
JE8JE7
JE1
JE2
EMI BOARD
RED
BLACK
BLACK
RED
VIO
GRAY
B LA
C K
RED
L2L1
SURF. ELEM. POWER ON
LIGHT
BLACK RED
LP 1
H1 H2
L 2
RED RED/BLK
RED
RED/BLK
PU RP
LE
PURPLE
RED
(H1)a(H2)
(H1)b
P
L2 L1
RED
PU RP
LE
O R
G
RED
RED
BLACK
WHITE
YELLOW
GREEN CHASSIS GROUND
C A U T I O N Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
W A R N I N G This unit must be properly grounded. See installation instructions for proper grounding instructions. NOTE: Trailers or stripes will be the second color in a color combination.
1413
Electric All Induction 36 Wide Rangetop Wiring Diagram
POWER BOARD
JOUT1
JOUT2 SMALL COIL
J3 TEMP CONTROL
J14
J15
J11
J10
LED BOARD
FRONT
REAR
LARGE COIL JOUT3
JOUT4
J2
J12
J13
TEMP CONTROL
WHITE
YELLOW
RED
BLACK
AC FAN
J16
J17
J6
J7
J4
J5
J18
J19
JE5
JE6
JE4JE3
JE8JE7
JE1
JE2
EMI BOARD
POWER BOARD
JOUT1
JOUT2 SMALL COIL
J3 TEMP CONTROL
J14
J15
SMALL COIL POTENTIOMETER
LED BOARD
FRONT
REAR
LARGE COIL
LARGE COIL
POTENTIOMETER
JOUT3
JOUT4
J2
J12
J13
TEMP CONTROL
RED
BLACK
WHITE
YELLOW
AC FAN
J16
J17
J6
J7
J4
J5
J18
J19
JE5
JE6
JE4JE3
JE8JE7
JE1
JE2
EMI BOARD
RIGHTCENTER
BLUE
WHITE
ORG
BROWN
SMALL COIL POTENTIOMETER
LARGE COIL POTENTIOMETER
SECTION
J9
J8
J9
J8
J11
J10
RED
RED
VIO
BLACK
BLACK
GRAY
RED
BLACK
BLACK
RED
VIO
GRAY
POWER LINE CONDITIONER
J1
L1C L2R
L2
L1
RED
BLACK
GREEN CHASSIS GROUND
J2
L1RL2C
J4 J3J6 J5
L1LL2L
POWER BOARD
JOUT1
JOUT2 SMALL COIL
J3 TEMP CONTROL
J14
J15
J11
J10
LED BOARD
FRONT
REAR
LARGE COIL JOUT3
JOUT4
J2
J12
J13
TEMP CONTROL
WHITE
YELLOW
RED
BLACK
AC FAN
J16
J17
J6
J7
J4
J5
J18
J19
JE5
JE6
JE4JE3
JE8JE7
JE1
JE2
EMI BOARD
LEFT
SMALL COIL POTENTIOMETER
LARGE COIL POTENTIOMETER
J9
J8
RED
BLACK
BLACK
RED
VIO
GRAY
SECTION SECTION
YELLOW
WHT/RED
(FRONT)
(REAR)
(REAR)
(FRONT)
(FRONT)
(REAR)
C A U T I O N Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
W A R N I N G This unit must be properly grounded. See installation instructions for proper grounding instructions. NOTE: Trailers or stripes will be the second color in a color combination.
1615
Electric Induction/Radiant 36 Wide Rangetop Wiring Diagram
2200/1000 WATT L. F. ELEM.
1500 WATT L.R. ELEM.
RED/YEL
B LK
/W H
BLK
YEL/BLK
WH/BLK
B LK
RED
RED/BLK
YEL/RED
WH/RED
RE D
/B LK
ORG
L2L1
SURF. ELEM. POWER ON
LIGHT
BLACK RED
LP 1
H1 H2
L 2
RED RED/BLK
YEL/RED
YEL/BLK
WH/BLK
RED
WH/RED
RED
RED/BLK
RED/BLK
RED/BLKRED/BLK
RED
PU RP
LE
PURPLE
RED
(H1)a(H2)
(H1)b
P
L2 L1
RED
ORG
ORG
LP 1
H1 H2
L 2
RED RED/BLK
RED RED/BLK
(H1)a(H2)
(H1)b
P
L2 L1
PU RP
LE
RED
BLK
W H
/R ED
RE D
/B LK
Y EL
/R ED
RE D
/B LK
O R
G
W H
/B LK RE
D /Y
EL
B LK
/W H
T
Y EL
/B LK
O R
G
Y EL
/R ED
W H
/R ED
MIDDLE FRONT
LEFT REAR
MIDDLE REAR
LEFT FRONT
BRIDGE ELEM
1800 WATT
800 WATT
1800 WATT
POWER BOARD
AC FAN
J16
J17
J6
J7
J4
J5
J18
J19
POWER LINE CONDITIONER
J1
L1C L2R
GREEN CHASSIS GROUND
ORG
BROWN
J2
L1RL2C
J4 J3
JOUT1
JOUT2 SMALL COIL
J3 TEMP CONTROL
J14
J15
J11
J10
LED BOARD
FRONT
REAR
LARGE COIL JOUT3
JOUT4
J2
J12
J13
TEMP CONTROL
RED
BLACK
WHITE
YELLOW
SMALL COIL POTENTIOMETER
LARGE COIL POTENTIOMETER
J9
J8
JE5
JE6
JE4JE3
JE8JE7
JE1
JE2
EMI BOARD
RED
BLACK
BLACK
RED
VIO
GRAY <
Related manuals for Viking VCRT301 Rangetop Installation Guide
Manualsnet FAQs
If you want to find out how the VCRT301 Viking works, you can view and download the Viking VCRT301 Rangetop Installation Guide on the Manualsnet website.
Yes, we have the Installation Guide for Viking VCRT301 as well as other Viking manuals. All you need to do is to use our search bar and find the user manual that you are looking for.
The Installation Guide should include all the details that are needed to use a Viking VCRT301. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.
The best way to navigate the Viking VCRT301 Rangetop Installation Guide is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.
This Viking VCRT301 Rangetop Installation Guide consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.
You can download Viking VCRT301 Rangetop Installation Guide free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.
To be able to print Viking VCRT301 Rangetop Installation Guide, simply download the document to your computer. Once downloaded, open the PDF file and print the Viking VCRT301 Rangetop Installation Guide as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.