Viking DERT361 Rangetop Installation Guide PDF

1 of 8
1 of 8

Summary of Content for Viking DERT361 Rangetop Installation Guide PDF

Viking Installation Guide

F1485L EN (021808J)

Electric Ranges/Rangetops

Viking Range Corporation

111 Front Street

Greenwood, Mississippi 38930 USA

(662) 455-1200

For product information,

call 1-888-VIKING1 (845-4641)

or visit the Viking Web site at

vikingrange.com

3

Description VERT301-4B DERT301-4B DERT361-5B Overall Width 29 7/8 (75.9 cm) 29 7/8 (75.9 cm) 35 7/8 (91.1 cm) Overall Height BASE HEIGHT BASE HEIGHT

To top of To top of glass frame - 7 7/8 (20.0 cm) side trim - 6 1/8 (15.6 cm) ADDITIONS TO BASE HEIGHT

To top of island trim add 1 1/4 (3.2 cm) add 0 (0 cm) To top of backguard add 6 (15.2 cm) add 6 (15.2 cm) To top of high-shelf add 23 1/2 (59.7 cm) add 23 1/2 (59.7 cm) Overall Depth from To end of:

Rear side panel - 24 (61.0 cm) 24 7/16 (62.1 cm) control panel - 25 15/16 (65.9 cm) 26 1/8 (66.35 cm) knobs - 27 7/16 (69.7 cm) 27 5/8 (70.2 cm)

Cutout Width 30 (76.2 cm) 30 (76.2 cm) 36 (91.4 cm) Cutout Height 7 1/2 (19.1 cm) 5 3/4 (14.6 cm) 5 3/4 (14.6 cm) Cutout Depth 24 (61.0 cm) 24 7/16 (62.1 cm) 24 7/16 (62.1 cm) Electrical Connection 40 amp 40 amp 50 amp Requirements 3-Wire, 240/208 VAC, 60 Hz. Unit is equipped with No. 10 ground wire in conduit. Should be

fused separately. Maximum Amps 240V- 34.6 amps 240V- 35.0 amps 240V- 45.0 amps

208V- 29.8 amps 208V- 30.3 amps 208V- 40.0 amps

Surface Elements 240V 208V 240V 208V 240V 208V Left Front 1500 watts 1125 watts 1800 watts 1350 watts 1800 watts 1350 watts Bridge N/A N/A 800 watts 600 watts 800 watts 600 watts Left Rear 2400 watts 1800 watts 1800 watts 1350 watts 1800 watts 1350 watts Center N/A N/A N/A N/A 2700 watts 2025 watts Right Front 1800 watts 1350 watts 1500 watts 1125 watts 1500 watts 1125 watts Bridge 800 watts 600 watts N/A N/A N/A N/A Right Rear 1800 watts 1350 watts 2500 watts 1875 watts 2200 watts 1650 watts

Approximate 110 lbs. (49.5 kg) 52 lbs. (23.4 kg) 63 lbs. (28.4 kg) Shipping Weight

SPECIFICATIONS-ELECTRIC RANGETOP

Minimum clearances from adjacent combustible construction Cooking surfaces and below (36[91.4 cm] and below)

Sides- 0 Rear- 0 with backguard or highshelf; 0 with island trim and non-combustible wall;

6 (15.2 cm) with island trim and combustible rear wall Top grate support - 36 (91.4 cm)

Above cooking surface (above 36[91.4 cm]) Sides- 6 (15.2 cm) Within 6 (15.2 cm) side clearance, wall cabinets no deeper than 13 (33.0 cm) must be minimum 18 (45.7 cm) above cooking surface.

Wall cabinets directly above product must be minimum 36 (91.4 cm) above cooking surface

It is not recommended to install two or more units side by side.

IMPORTANT: PLEASE READ AND FOLLOW Before beginning, please read these instructions completely and carefully. Do not remove permanently affixed labels, warnings, or plates from product. This may void the warranty. Please observe all local and national codes and ordinances. Please ensure that this product is properly grounded. The installer should leave these instructions with the consumer who should retain for local inspectors use

and for future reference.

Installation must conform with local codes or in the absence of codes, with the National Electrical Code, ANSI/NFPA 70-latest edition. In CANADA: Electrical installation must be in accordance with the current CSA C22.2 Canadian Electrical Codes Part 1 and/or local codes.

GENERAL INFORMATION 1. WARNING: The use of cabinets for storage above the appliance may result in potential fire or burn hazard.

Combustible items may ignite, metallic items may become hot and cause burns. If a cabinet storage is to be provided the risk can be reduced by installing a rangehood that projects horizontally a minimum of 5 (12.7 cm) beyond the bottom of the cabinets.

2. WARNING: This appliance shall not be used for space heating. This information is based on safety considerations.

3. All openings in the wall behind the appliance in the floor under the appliance shall be sealed. 4. Keep appliance area clear and free from combustible materials, gasoline, and other flammable vapors. 5. Disconnect the electric supply to the appliance before servicing. 6. When removing oven for service and/or cleaning, disconnect AC power supply. 7. Electrical requirements:

Listed in specifications chart. Electrical installation should comply with national and local codes.

WARNING!!! ELECTRICAL GROUNDING INSTRUCTIONS

This rangetop must be electrically grounded in accordance with local codes or, in the absence of codes, with the National Electrical Code, ANSI/NFPA 70-latest edition.

FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.

BACK TRIM ACCESSORIES Assembly and installation instructions are included with all back trim accessories.

2

5

PROXIMITY TO SIDE CABINET INSTALLATION 1. This rangetop may be installed directly adjacent to existing 36 (91.4 cm) high base cabinets. IMPORTANT: The

top grate support MUST be 3/8 (.95 cm) above the adjacent base cabinet countertop. 2. The rangetop CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical

surfaces above 36 (91.4 cm) high. There must be a minimum of 6 (15.2 cm) side clearance from the rangetop to such combustible surfaces above the 36 (91.4 cm) counter height.

3. Within the 6 (15.2 cm) side clearance to combustible vertical surfaces above 36 (91.4 cm) , the maximum wall cabinet depth must be 13 (33.0 cm) and wall cabinets within this 6 (15.2 cm) side clearance must be 18 (45.7 cm) above the 36 (91.4 cm) high countertop.

4. Wall cabinets above the rangetop must be a minimum of 36 (91.4 cm) above the rangetop cooking surface for the full width of the rangetop. This minimum height requirement does not apply if a rangehood is installed over the cooking surface.

ELECTRICAL REQUIREMENTS Check your national and local codes regarding this unit. This rangetop is supplied with a 3 wire conduit which is equipped with a No. 10 ground wire. See next section for grounding instructions. This unit should be fused separately. CAUTION: Be sure the electrical power is off from the breaker box to the junction box until the unit is installed and ready to operate. The junction box should be located as shown in the drawing and connected to a suitable ground.

B

A B VERT 7 1/2 24

19.1 cm) (61.0 cm) DERT 5 3/4 24 7/16

(14.6 cm) (62.1 cm)

A

4

Minimum clearances from adjacent combustible construction Cooking surface and below (36 [91.4 cm ] and below)

Sides - 0 Rear - 0 with backguard or high shelf; 0 with island trim and non-combustible rear wall; 6 (15.2 cm) with island trim and combustible rear wall.

Top grate support - 36 (91.4 cm) Above cooking surface (above 36 [91.4 cm])

Sides - 6 (15.2 cm) Within 6 (15.2 cm) side clearance, wall cabinets no deeper than 13 (33.0 cm) must be minimum 18 (45.7 cm) above cooking surface.

Wall cabinets directly above product must be minimum 36 (91.4 cm) above cooking surface Use range only with factory supplied legs.

Description VESC306-4B Overall Width 29 7/8 (75.9 cm) Overall Height from Bottom Base Height

To top of glass frame - Min. 35 7/8 (91.1cm) to Max. 37 5/8 (95.6 cm) [Legs adjust 1 3/4 (4.5cm)]

Additions to Base Height To top of island trim - add 1 1/4 (3.2 cm) To top of backguard - add 6 (15.2 cm) To top of high shelf - add 23 1/2 (59.7 cm)

Overall Depth from Rear To end of side panel - 24 5/16 (61.8 cm) To end of control panel - 26 1/4 (66.7 cm) To end of knobs - 27 3/4 (70.5 cm)

Electrical Requirements 240-208/120 VAC/60Hz - Connect with locally supplied 3-wire, flexible cord rated 60 amp 125-250 minimum. Cord must be agency approved for use with household electric ranges.

Maximum Amp Usage 240V - 58.5 amps 208V - 50.7 amps Preheat Rating 240V - 24.0 amps 208V - 20.8 amps Surface Element Rating 240V

Left Front 1500 watts Left Rear 2400 watts Right Front 1800 watts Bridge 800 watts Right Rear 1800 watts

Broil Rating 240V Maxi Broil - (8 Pass) 3000 watts Mini Broil - (4 Pass) 1250 watts

Bake Rating (partial power from broil element 240V - 2935 watts Convection Cook Rating 240V - 2200 watts Oven Interior Dimension Width - 23 ( 58.4 cm)

Height - 16 1/8 (41.1 cm) Depth - 15 3.8 (39.1 cm) Overall size - 3.3 cu. ft.

Approximate Shipping Weight 424 lb. (190.8 kg.

SPECIFICATIONS - ELECTRIC RANGE

7

FINAL PREPARATION 1. Some stainless steel parts may have a plastic protective wrap which must be peeled off. All stainless steel body

parts should be wiped with hot, soapy water and with a liquid cleaner designed for this material. If build-up occurs, do not use steel wool, abrasive cloths, cleaners, or powders!! If it is necessary to scrape stainless steel to remove encrusted materials, soak with hot, wet cloths to loosen the material, then use a wood or nylon scraper. Do not use a metal knife, spatula, or any other metal tool to scrape stainless steel! Scratches are almost impossible to remove.

2. The interior of the oven should be washed thoroughly with hot, soapy water to remove film residues and any installation dust or debris before being used for food preparation, then rinsed and wiped dry. Solutions stronger than soap and water are rarely needed.

REPLACEMENT PARTS Only authorized replacement parts may be used in performing service on the range. Do not repair or replace any part of the appliance unless specifically recommended in the manual. All other servicing should be referred to a qualified technician.

DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE. SUCH USE MAY RESULT IN A FIRE, ELECTRICAL SHOCK, OR OTHER PERSONAL INJURY.

6

WOOD/COMPOSITE OVERLAY INSTALLATION (Including Custom Ventilator Installation) The bottom of a standard hood should be 30 (76.2 cm) min to 36 (91.4 cm) max above the ceramic glass surface. This would typically result in the bottom of the hood being 66 (167.6 cm) to 72 (182.9 cm) above the floor. Refer to the rangehood installation instructions for further information. These dimensions provide for safe and efficient operation of the hood.

30 (76.2 cm) min 36 (91.4 cm) max

66 - 72 (167.6 cm - 182.9 cm)

30 (76.2 cm) min 36 (91.4 cm) max

66 - 72 (167.6 cm - 182.9 cm)

36 (91.4 cm)

ISLAND INSTALLATIONWALL INSTALLATION

36 (91.4 cm)

Metal Hood Metal Hood

Wood/Composite Overlay Wood/Composite Overlay

Countertop

ELECTRICAL CONNECTION With the rangetop positioned in front of the cabinet opening, connect the wire leads extending from the conduit to the junction box, making sure the neutral (white) wire is connected to the appropriate terminal. Check your local codes to see which of the options below should be used in grounding the unit. Do not use GFI circuit.

OPTION 1 Connnect the neutral (white) wire and the grounding (bare) wire with the incoming neutral (white) power supply lines.

OPTION 2 If the junction box is grounded, untwist the grounding (bare) wire and attach to the junction box. Attach the neutral (white) wire to neutral (white) power supply line.

OPTION 3 Untwist the grounding (bare) wire and attach it to a suitable ground. Attach neutral (white) wire to the incoming neutral (white) power supply line.

Identification Label Location - (bottom of unit in left rear corner)

Countertop

9

RANGE INSTALLATION Legs 1. Legs are packed in styrofoam top pack. 2. Legs should be installed near to where the appliance is to be used, as they are not secure for long transit. After

unpacking the range, raise it about a foot to remove the bottom shipping skid. Keep the unit raised to permit the legs to be screwed into their couplings and lower it gently to keep any undue strain from the legs and internal mounting hardware. It is strongly recommended that a pallet or lift jack be used rather than tilting.

BACK TRIM ACCESSORIES Assembly and installation instructions are included with all back trim accessories.

STABILITY DEVICE INSTALLATION INSTRUCTIONS 1. The anti-tip bracket is to be attached to the rear wall as shown. The dimension for the bracket location from the

floor is to be determined after the range legs have been adjusted to the proper installation height shown in the installation instructions and the range has been leveled.

2. Measure from the floor to the bottom of the anti-tip opening located on the back of the range. Measured Dim. (A). 3. Locate the anti-tip bracket on the wall with the top left corner at the measured dimension plus 1/2 from the floor

and the 5-5/8 from where the left side of the range (facing range) is to be located. 4. Slide the range into place. Be sure the anti-tip bracket slides into the anti-tip opening.

WARNING THIS RANGE CAN TIP INJURY TO PERSONS COULD RESULT INSTALL ANTI-TIP DEVICE PACKED WITH RANGE SEE INSTALLATION INSTRUCTIONS

8

PROXIMITY TO SIDE CABINET INSTALLATION 1. This range may be installed directly adjacent to existing 36 (91.4 cm) high base cabinets. IMPORTANT: The top

grate support MUST be 3/8 (.95 cm) above the adjacent base cabinet countertop. This may be accomplished by raising the unit using the adjustment spindles on the legs.

2. The range CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above 36 (91.4 cm) high. There must be a minimum of 6 (15.2 cm) side clearance from the range to such combustible surfaces above the 36 (91.4 cm) counter height.

3. Within the 6 (15.2 cm) side clearance to combustible vertical surfaces above 36 (91.4 cm) , the maximum wall cabinet depth must be 13 (33.0 cm) and wall cabinets within this 6 (15.2 cm) side clearance must be 18 (45.7 cm) above the 36 (91.4 cm) high countertop.

4. Wall cabinets above the range must be a minimum of 36 (91.4 cm) above the range cooking surface for the full width of the range. This minimum height requirement does not apply if a rangehood is installed over the cooking surface.

ELECTRICAL REQUIREMENTS Check your local codes regarding this unit. This range requires 3 wires, 240-208/120 VAC, 60 Hz. See next section for grounding instructions. It should be fused separately. CAUTION: Be sure the electrical power is off from the breaker box to the junction box until the range is installed and ready to operate. The junction box should be located as shown in the drawing and connected to suitable ground. Do not use GFI circuit.

18 Minimum (45.7 cm)

36 Minimum (91.4 cm)

36 (91.4 cm)

0

0

3/8 (.95 cm)

6 Minimum (15.2 cm)

13 Maximum (33.0 cm)

30 (76.2 cm)

Adjustable Legs

Anti-tip Bracket

11

WOOD/COMPOSITE OVERLAY INSTALLATION The bottom of a standard hood should 30 (76.2 cm) min to 36 (91.4 cm) max above the ceramic glass surface. This would typically result in the bottom of the hood being 66 (167.6 cm) to 72 (182.9 cm) above the floor. Refer to the rangehood installation instructions for additional information. These dimensions provide for safe and efficient operation of the hood.

66 - 72 (167.6 cm - 182.9 cm)

66 - 72 (167.6 cm - 182.9 cm)

36 (91.4 cm)

ISLAND INSTALLATIONWALL INSTALLATION

36 (91.4 cm)

Metal Hood Metal Hood

Wood/Composite Overlay

30 (76.2 cm) min 36 (91.4 cm) max

30 (76.2 cm) min 36 (91.4 cm) max

10

ELECTRICAL CONNECTION Use a 3-wire power supply cord kit rated for 60 amps - 125/250 volts with closed loop terminals and marked for use with ranges. Where local codes do not permit grounding through neutral, use a 4-wire power supply cord. the cord or conduit must be secured to the range with the strain relief bracket. The electrical connection is made at the terminal block, which is located behind the access door on the back of the range.

3-Wire Power Supply Cord 1. Remove access door. 2. Remove supply cord strain relief bracket and 3-supply cord

mounting screws on the terminal block. 3. Feed supply cord up thru the hole in the bottom of the

range back. 4. Attach the line #1 (red) and line #2 (black) leads to the

outside terminal and the neutral wire (white) to the center terminal on the terminal block.

5. Reattach supply cord strain relief bracket over supply cord, pushing supply cord up toward terminal block to relieve strain before tightening.

6. Reattach access door.

4-Wire Power Supply Cord 1. Remove access door. 2. Remove supply cord strain relief bracket and 3-supply cord

mounting screws on the terminal block. 3. Remove grounding screw; cut-off and discard ground strap. 4. Feed supply cord up thru the hole in the bottom of the

range back. 5. Attach the ground lead (green) with the ground screw that

was removed in step #3. 6. Attach the line #1 (red) and line #2 (black) leads to the

outside terminal and the neutral wire (white) to the center terminal on the terminal block.

7. Reattach supply cord strain relief bracket over supply cord, pushing supply cord up toward terminal block to relieve strain before tightening.

8. Reattach access door.

Countertop Countertop

Wood/Composite Overlay

13

ELECTRICAL CONNECTION WITH CONDUIT Use 1/2 (1.3 cm) trade size conduit with a conduit clamp, 12 AWG/600 volt copper conductor colored red for line 1 and black for line 2 and 14 AWG/600 volt copper conductor colored white for neutral with closed loop terminals marked for use with ranges. Where local codes do not permit grounding through neutral, use a green 12 AWG copper conductor as directed in the 4-wire connector directions. The conduit must be secured to the range with the strain relief bracket. The electrical connection is made at the terminal block which is located behind the access door on the back of the range.

3-Wire Power Connection 1. Remove access door. 2. Remove strain relief mounting angle and reattach as shown. 3. Feed 1/2 (1.3 cm) trade size conduit through the hole in the

bottom of the range back and secure to the strain relief bracket with a conduit clamp.

4. Feed line #1 (red 12 AWG/600v copper conductor), line #2 (black 12 AWG/600v copper conductor) and neutral (white 14 AWG/600v copper conductor) through conduit and attach closed loop terminals marked of use with range.

5. Remove 3 mounting screws and attach line #1 (red) to the left terminal line #2 (black) to the right terminal, the neutral wire (white) to the center terminal.

6. Reattach the access door.

4-Wire Power Connection 1. Remove access door. 2. Remove strain relief mounting angle and reattach as shown. 3. Feed 1/2 (1.3 cm) trade size conduit through the hole in the

bottom of the range back and secure to the strain relief bracket with a conduit clamp.

4. Feed line #1 (red 12 AWG/600v copper conductor), line #2 (black 12 AWG/600v copper conductor), neutral (white 14 AWG/600v copper conductor) and grounding wire (green 12 AWG copper conductor) through conduit and attach closed loop terminals marked of use with range. (Terminal is not required on grounding wire if used with ground washer.

5. Remove 3 mounting screws and green grounding screw. Cut off and discard ground strap. Attach line #1 (red) to the left terminal, line #2 (black) to the right terminal, the neutral wire (white) tothe center terminal and the copper ground wire to the green grounding screw using the ground washer.

6. Reattach the access door.

12

IMPORTANT: LEVELING/ADJUSTMENTS/ALIGNMENT Closely follow the procedures below to ensure proper performance and appearance of the range.

1. If the floor is smooth and level, level the unit with the screw thread of the legs. Set the high corner of the range so that the the top of the grate support is 3/8 (.95cm) above the countertop, and level the range to the high corner.

2. If the floor is uneven or has a decided slope, level the unit with metal shims, as the adjustment required may exceed the thread available in the leg.

3. After the range is properly leveled, the drip tray handle may be aligned by loosening the screws and adjusting the handle horizontally within the limits provided by the slotted screw holes.

4. A level should be placed across the top of the range and the unit leveled both front-to-back and side-to-side. If it is not level, burner combustion may be erratic, liquid, or semi-liquid batters will cook at an angle, and the unit may not function efficiently.

A. Right Side Front / Back Adjustable Legs

B. Left Side Front / Back Adjustable Legs

All ranges are tested before leaving the factory. When the range is connected to the electrical service, the installer should use the Performance Checklist for his final checks.

When adjustments are required, contact your dealer/installer for corrections. If assistance is not available, contact Viking Range Corporation Preferred Service for the nearest authorized service agent at (888) 845-4641. All corrections to installation are the responsibility of the dealer/installer or end user.

B A

Identification Label Location (located behind door)

15

PERFORMANCE CHECKLIST The installer should carry out the following performance checks. Refer to instructions below.

1. Check top surface elements - glow red when turned on. 2. Check hot surface indicator lights - glow red when corresponding element is on. 3. Check oven bake function - bake element on full power.

Convection bake function - bake element is same with the convection fan on. 4. Check convection cook function - convection cook element (behind fan cover) on and convection fan on. 5. Check mini broil function - center broil element on. 6. Check maxi broil function - center and outside broil elements on. Convection broil function is the same as maxi

broil with the convection fan on. 7. Check self-clean function - door will lock and in approximately 30 seconds; the center and outside broil elements

will turn on. Check broil elements through window to make sure they are on, then abort self-clean cycle to unlock door. CAUTION: Do not run self-clean cycle for more than 10 minutes with oven racks and rack supports inside oven. This could cause them to discolor due to the high temperature required for self-cleaning.

FINAL PREPARATION 1. Some stainless steel parts may have a plastic protective wrap which must be removed. The interior of the oven

should be washed thoroughly with hot, soapy water to remove film residues and any installation dust or debris before being used for food preparation, then rinsed and wiped dry. Solutions stronger than soap and water are rarely needed.

2. All stainless steel body parts should be wiped with hot, soapy water and with a liquid cleaner designed for this material. If buildup occurs, do not use steel wool, abrasive cloths, cleaners, or powders! If it is necessary to scrape stainless steel to remove encrusted materials, soak with hot, wet cloths to loosen the material, then use a wood or nylon scraper. Do not use a metal knife, spatula, or any other metal tool to scrape stainless steel! Scratches are almost impossible to remove.

Any adjustments necessary that are a result of the installer not following instructions will be the responsibility of the installer, dealer, or the end user of the product.

REPLACEMENT PARTS Only authorized replacement parts may be used in performing service on the range. Do not repair or replace any part of the appliance unless specifically recommended in the manual. All other servicing should be referred to a qualified technician.

14

Manualsnet FAQs

If you want to find out how the DERT361 Viking works, you can view and download the Viking DERT361 Rangetop Installation Guide on the Manualsnet website.

Yes, we have the Installation Guide for Viking DERT361 as well as other Viking manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Installation Guide should include all the details that are needed to use a Viking DERT361. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Viking DERT361 Rangetop Installation Guide is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Viking DERT361 Rangetop Installation Guide consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Viking DERT361 Rangetop Installation Guide free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Viking DERT361 Rangetop Installation Guide, simply download the document to your computer. Once downloaded, open the PDF file and print the Viking DERT361 Rangetop Installation Guide as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.