Viking DCWN3644 Hood Installation Guide PDF

1 of 28
1 of 28

Summary of Content for Viking DCWN3644 Hood Installation Guide PDF

Viking Range Corporation

111 Front Street

Greenwood, Mississippi 38930 USA

(662) 455-1200

For product information,

call 1-888-VIKING1 (845-4641)

or visit the Viking Web site at

vikingrange.com

F20472D EN (022410)

ULCUL

Viking Installation Guide

Designer Hoods

Table of Contents Warnings & Important Information _____________________________________________________________________________ 3-4 DCH 12H. Classic Chimney Wall Hoods w/Standard Ventilator

Dimensions & Specifications ________________________________________________________________________ 5 Clearance Dimensions _____________________________________________________________________________ 6 Interior Ventilator Dimensions_______________________________________________________________________ 7

DPPV Custom Power Packs w/Standard Ventilator Dimensions & Specifications ________________________________________________________________________ 8 Installing Hood Canopy ____________________________________________________________________________ 9 Clearance Dimensions ____________________________________________________________________________ 10 Interior Ventilator Dimensions _____________________________________________________________________ 11

DCWH/DCWN/DCWL Classic Chimney Wall Hoods Ledgeless & Ledge 30, 33, 36, 39, 42, 45, 48, & 51

Dimensions & Specifications _______________________________________________________________________ 12 Clearance Dimensions_____________________________________________________________________________13 Interior Ventilator Dimensions _____________________________________________________________________ 14 Exterior Ventilator Dimensions ____________________________________________________________________ 15

DCIH Classic Chimney Island Hoods 36, 42, & 54 Dimensions & Specifications _______________________________________________________________________ 16 Clearance Dimensions_____________________________________________________________________________17 Interior Ventilator Dimensions ______________________________________________________________________18 Exterior Ventilator Dimensions ____________________________________________________________________ 19

DTWS Slim Traditional Wall Hoods 30, 36, 42, & 48 Dimensions & Specifications _______________________________________________________________________ 20 Clearance Dimensions ____________________________________________________________________________ 21 Interior Ventilator Dimensions______________________________________________________________________ 22 Exterior Ventilator Dimensions _____________________________________________________________________23

DTWN Tall Traditional Wall HoodsLedgeless 30, 36, 42, & 48 Dimensions & Specifications _______________________________________________________________________24 Clearance Dimensions_____________________________________________________________________________25 Interior Ventilator Dimensions _____________________________________________________________________26 Exterior Ventilator Dimensions _____________________________________________________________________27

DBCV Wall Custom Ventilator System Dimensions & Specifications _______________________________________________________________________28 Installing Hood Canopy ___________________________________________________________________________29 Clearance Dimensions ____________________________________________________________________________ 30 DBCV Ventilator Dimensions _______________________________________________________________________31

DICV Island Custom Ventilator System Dimensions & Specifications_______________________________________________________________________ 33 Installing Hood Canopy___________________________________________________________________________ 34 Clearance Dimensions ____________________________________________________________________________ 35 DICV Ventilator Dimensions ________________________________________________________________________36

Planning Information__________________________________________________________________________________ 38 Installation Procedure

Installation (DCH 12H. Classic Chimney Wall Hoods w/Standard Ventilator) ____________________________ 39 Duct Cover Option (DCH 12H. Classic Chimney Wall Hoods w/Standard Ventilator) _____________________ 41 Installation (DCH 12H. Classic Chimney Wall Hoods w/Recirculating Kit) _______________________________ 42 Installation (DCWH/DCWN/DCWL Classic Chimney & DTWN Tall Traditional Wall Hoods)________________________________________________________________ 44

Duct Cover Option (DCWH/DCWN/DCWL Classic Chimney Wall Hoods) _______________________________ 45 Duct Cover Option (DTWN Tall Traditional Wall Hoods)_______________________________________________ 46 Installation (DTWS Slim Traditional)_________________________________________________________________ 46 Duct Cover Option (DTWS Slim Traditional Wall Hoods) ______________________________________________ 48 Installation (DCIH Classic Chimney Island Hoods) ____________________________________________________ 50

Service & Registration_________________________________________________________________________________ 52

3

IMPORTANTPlease Read and Follow! NOTE: If installing hood with warming shelf panel, install warming shelf panel first.

IMPORTANT PLEASE READ AND FOLLOW Before beginning, please read these instructions completely and carefully.

Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty.

Please observe all local and national codes and ordinances. If no local codes are applicable, wire in accordance with the National Electrical Code, ANSI/NFPA 70-latest edition.

The installer should leave these instructions with the consumer who should retain for local inspectors use and for future reference.

Check with a qualified and trained installer or local codes for makeup air requirement, if any.

This hood is for residential installation only and is not designed for installation over a commercial product. Make sure power is off at the main circuit breaker or fuse box before making connections. To avoid risk of fire, electric shock, or injury to persons, turn off the electricity to the hood from the power supply before servicing or cleaning.

Viking hoods are equipped with the variable speed controls for blowers. These units will not function with a single speed ventilator. All Viking ventilator kits are designed specifically for use with Viking hoods. Use of any non-Viking ventilator kit will void the hood warranty.

READ AND SAVE THESE INSTRUCTIONS

W A R N I N G TO REDUCE THE RISK OF A RANGETOP GREASE FIRE 1. Never leave surface units unattended at high

setting. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

2. Always turn hood ON when cooking at high heat or when cooking flaming foods. (i.e. crepes suzette, cherries jubilee, peppercorn beef flamb).

3. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.

4. Use proper pan size. Always use cookware appropriate for the size of the surface element.

TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING 1. Installation work and electrical wiring must be

done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.

2. Sufficient air is needed for proper combustion and exhausting of gases through the flute (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturers guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

3. When cutting or drilling into wall or ceiling, do not damage electrical wiring or other hidden utilities.

4. Ducted fans must always be vented to the outdoors.

5. WARNING!: To reduce risk of fire, use only metal ductwork.

6. CAUTION!: To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings, or into attics, crawl spaces, or garages.

7. CAUTION!: To Reduce the Risk of Fire and Electric Shock, Install this rangehood only with remote blower models manufactured by Viking, model numbers DEV900/DEV1200, VEV900/VEV1200, OR DEV1500, VEV1500 or integral blowers manufactured by Viking, model numbers DIV300, DIV440, DIV600, DIV800, DIV1200, VIV300, VIV600, or VIV1200. NOTE Please refer inside for specific canopy/blower combinations.

W A R N I N G

W A R N I N G TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

2

5

IMPORTANTPlease Read and Follow!

4

W A R N I N G TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS Rangehoods must be installed with the ventilators that are specified on their carton indicating suitability with this model. Other ventilators cannot be substituted.

C A U T I O N For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

W A R N I N G TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGETOP GREASE FIRE, OBSERVE THE FOLLOWING. (Based on Kitchen Firesafety Tips, published by NFPA.)

1. SMOTHER FLAMES with a close fitted lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

2. NEVER PICK UP A FLAMING PAN. You may be burned.

3. DO NOT USE WATER, including wet dishcloths or towels a violent steam explosion will result.

4. Use an extinguisher ONLY if You know it is a Class ABC extinguisher, and you already know how to operate it.

The fire is small and contained in the area where it started.

The fire department is being called. You can fight the fire with your back to an exit.

DCH 12H. Classic Chimney Wall Hoods w/Standard Ventilator Description 30 36 Duct cover width 16 (40.6 cm) Duct cover depth 12 (30.5 cm) Duct cover height 18 (45.7 cm) to 30 (76.2 cm) Number of lights 2 Number of filters 2 Interior ventilator kit 460 CFM Interior duct size* 7 (17.8 cm) InteriorMaximum amps 5.6

* Disregard when using recirculating kits. 460 CFM blower is shipped with hood. NOTE: All products must be hard wired with 2-wire with ground.

24

(61.0 cm)

16(40.6 cm)

12(30.5 cm)

18(30.5 cm)to30(76.2 cm)

12

(30.5 cm)

A A (Hood width)

30W. 29-7/8 (75.9 cm) 36W. 35-7/8 (91.1 cm)

2 (5.1 cm)

Dimensions & Specifications (DCH 12H. Classic Chimney Wall Hoods w/Standard Ventilator)

NOTE: Optional duct cover sold separately.

6

Clearance Dimensions

7

30min. (76.2 cm)to33max. (83.8 cm)

66min. (167.6 cm)to69max. (175.3 cm)

36

(91.4 cm)

A 14-15/16 (37.9 cm) 17-15/16 (45.6 cm)

16 (40.6 cm)

A

4 (10.2 cm)

120 V

7 (17.8 cm) dia. duct location

9-3/4 (24.8 cm)

30W. 36W.

460 CFM Interior Ventilator Installation

(DCH 12H. Classic Chimney Wall Hoods w/Standard Ventilator)(DCH 12H. Classic Chimney Wall Hoods w/Standard Ventilator)

Top view

Interior Ventilator Dimensions

98

DPPV Custom Power Packs w/Standard Ventilator System Description 30 36 Number of lights 2 Number of filters 2 Interior ventilator kit 460 CFM Interior duct size 7 (17.8 cm) InteriorMaximum amps 5.6

460 CFM blower is shipped with hood. NOTE: All products must be hard wired with 2-wire with ground.

Dimensions & Specifications (DPPV Custom Power Packs w/Standard Ventilator System)

B*

A*

Bottom Cutout Dimensions

*For best results, center the unit over the burners of the cooking product (front to back; right to left).

Power Packs Description A (Hood Width) B (Hood Depth)

30 W. 28-11/16 (72.9 cm) 16-1/2 (41.9 cm) 36 W. 34-11/16 (88.1 cm) 16-1/2 (41.9 cm)

Make sure the back wall of the custom hood canopy is flush with the cutout so the ventilator system may be mounted as shown on page 9.

Installing Hood Canopy (Custom Hood Canopy Cutouts)

A B

Custom Hood Canopy

1) Position ventilator system inside of the custom hood canopy and center it front to back and left to right.

2) Bottom mounting holes fasten ventilator system to bottom of custom hood canopy with the screws provided.

Built-In Ventilator System

3) OPTIONAL Rear mounting holes fasten ventilator system to rear of custom hood canopy.

1110

Clearance Dimensions

30min. (76.2 cm)to33max. (83.8 cm)

66min. (167.6 cm)to69max. (175.3 cm)

36

(91.4 cm)

(Custom Hood)

(DPPV Custom Power Packs w/Standard Ventilator System)

A 14-15/16 (37.9 cm) 17-15/16 (45.6 cm)

16 (40.6 cm)

A

4 (10.2 cm)

120 V

7 (17.8 cm) dia. duct location

9-3/4 (24.8 cm)

30W. 36W.

460 CFM Interior Ventilator Installation

(DPPV Custom Power Packs w/Standard Ventilator System)

Top view

Interior Ventilator Dimensions

Clearance Dimensions

13

Dimensions & Specifications

12

24

(61.0 cm)

B

C

A

D

12

(30.5 cm)

E

E (Hood height) 30W. 12 (30.5 cm) 33W. 12 (30.5 cm) 36W. 14 (35.6 cm) 39W. 14 (35.6 cm) 42W. 14 (35.6 cm) 45W. 14 (35.6 cm) 48W. 14 (35.6 cm) 51W. 14 (35.6 cm)

A (Duct cover width) 30W. 10 (25.4 cm) 33W. 10 (25.4 cm) 36W. 12 (30.5 cm) 39W. 12 (30.5 cm) 42W. 12 (30.5 cm) 45W. 12 (30.5 cm) 48W. 18 (45.7 cm) 51W. 18 (45.7 cm)

B (Hood width) 30W. 29-7/8 (75.9 cm) 36W. 35-7/8 (91.1 cm) 42W. 41-7/8 (106.4 cm) 48W. 47-7/8 (121.6 cm)

D (Duct height)

30/33W.

36/39W. 42/45W. 48/51W.

18 (45.7 cm) to 30 (76.2 cm)

16 (40.6 cm) to 28 (71.1 cm)

C (Hood widthLedge models) 33W. 32-7/8 (83.5 cm) 39W. 38-7/8 (98.4 cm) 45W. 44-7/8 (114.0 cm) 51W. 50-7/8 (129.2 cm)

25-1/2

(64.8 cm)

Ledge models o nly

2(5.1 cm)

(DCWH Classic Chimney Wall Hoods 30, 36, 42, & 48) (DCWN Ledgeless models 30, 36, 42, & 48) (DCWL Ledge models 33, 39, 45, & 51)

* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct run is 50 ft. ** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft. NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all Designer hoods.

30min. (76.2 cm)to36max. (91.4 cm)

66min. (167.6 cm)to72max. (182.9 cm)

36

(91.4 cm)

(DCWH/DCWN/DCWL Classic Chimney Wall Hoods)

NOTE: For best performance, it is recommended that the bottom of the hood be 30 (76.2 cm) to 36 (91.4 cm) above the countertop. These dimensions provide for safe and efficient operation of the hood.

DCWH/DCWN/DCWL Classic Chimney Wall HoodsLedgeless & Ledge Description 30/33 36/39 42/45 48/51

Duct cover width 10 (25.4 cm) 12 (30.5 cm) 12 (30.5 cm) 18 (45.7 cm)

Duct cover depth 12 (30.5 cm)

Duct cover height 18 (45.7 cm) to 30 (76.2 cm)

16 (40.6 cm) to 28 (71.1 cm)

16 (40.6 cm) to 28 (71.1 cm)

16 (40.6 cm) to 28 (71.1 cm)

Number of lights 2 2 2 3

Number of filters 2 2 3 3

Interior ventilator kits VINV300/600 VINV300/600 VINV600 VINV1200*

Exterior ventilator kits DEV900/1200* DEV900/1200* DEV900/1200* DEV1200*/1500**

In-line ventilator kits DIL900/1200 DIL900/1200 DIL900/1200 DIL1200

Interior duct size 7 (17.8 cm) 7 (17.8 cm) 7 (17.8 cm) 10 (25.4 cm)

Exterior duct size 10 (25.4 cm)

InteriorMaximum amps 2.8/3.8 2.8/3.8 3.8 7.3

ExteriorMaximum amps 6.6/3.9 6.6/3.9 6.6/3.9 4.3/5.1

In-LineMaximum amps 3.9/5.7 3.9/5.7 3.9/5.7 6.1

14

Exterior Ventilator Dimensions

15

1-1/2 (3.8 cm)

10 (25.4 cm) dia. duct location

1-1/2 (3.8 cm)

18 (45.8 cm)

23-15/16 (60.8 cm)

1-1/2 (3.8 cm) 120 V

power supply

6 (15.2 cm)

Classic Chimney w/Ledge

Classic Chimney

1-1/2 (3.8 cm)

7 (17.8 cm) dia. duct location

A1-1/2 (3.8 cm) 120V

power supply

6 (15.2 cm)

B

A 30W. 10 (25.4 cm) 33W. 10 (25.4 cm) 36W. 12 (30.5 cm) 39W. 12 (30.5 cm) 42W. 12 (30.5 cm) 45W. 12 (30.5 cm)

B 30W. 14-15/16 (37.9 cm) 33W. 14-15/16 (37.9 cm) 36W. 17-15/16 (45.6 cm) 39W. 17-15/16 (45.6 cm) 42W. 20-15/16 (53.2 cm) 45W. 20-15/16 (53.2 cm)

Classic Chimney w/Ledge

Classic Chimney

1-1/2 (3.8 cm)

1-1/2 (3.8 cm)

1-1/2 (3.8 cm)

18 (45.8 cm)

1-1/2 (3.8 cm) 120 V

power supply

Classic Chimney w/Ledge

Classic Chimney

6 (15.2 cm)

10 (25.4 cm) dia. duct location

900 or 1200 CFM External Ventilation Installation (48 models only)

23-15/16 (60.8 cm)

1-1/2 (3.8 cm)

1-1/2 (3.8 cm)A1-1/2

(3.8 cm) 120V power supply

Classic Chimney w/Ledge

Classic Chimney

6 (15.2 cm)

C

900 or 1200 CFM External Ventilation Installation (30, 36 & 42 models)

B

A 30W. 10 (25.4 cm) 33W. 10 (25.4 cm) 36W. 12 (30.5 cm) 39W. 12 (30.5 cm) 42W. 12 (30.5 cm) 45W. 12 (30.5 cm)

B 30W. 14-15/16 (37.9 cm) 33W. 14-15/16 (37.9 cm) 36W. 17-15/16 (45.6 cm) 39W. 17-15/16 (45.6 cm) 42W. 20-15/16 (53.2 cm) 45W. 20-15/16 (53.2 cm)

C (Duct diameter) 30W. 8 (20.3 cm)* 33W. 8 (20.3 cm)* 36W. 10 (25.4 cm) 39W. 10 (25.4 cm) 42W. 10 (25.4 cm) 45W. 10 (25.4 cm)

900 or 1200 CFM Exterior or In-Line Ventilator Installation for 30, 33, 36, 39, 42, & 45 models

900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation for 48 & 51 models

300 or 600 CFM Interior Ventilator Installation for 30, 33, 36, 39, 42, & 45 models

(DCWH/DCWN/DCWL Classic Chimney Wall Hoods) (DCWH/DCWN/DCWL Classic Chimney Wall Hoods)

1200 CFM Interior Ventilator Installation for 48 & 51 models

Top view

Top view

Top view

Top view

Interior Ventilator Dimensions

* 8 to 10 transition to be acquired locally.

Clearance Dimensions

17

Dimensions & Specifications

16

30

(76.2 cm)B

A

14(35.6 cm)

C2(5.1 cm)

12

(30.5 cm)

B (Hood width) 36W. 35-7/8 (91.1 cm) 42W. 41-7/8 (106.4 cm) 54W. 53-7/8 (136.8 cm)

A (Duct cover width) 36W. 12 (30.5 cm) 42W. 12 (30.5 cm) 54W. 18 (45.7 cm)

C (Duct height)

36W.

42W.

54W.

16 (40.6 cm) or

28 (71.1 cm) or

40 (101.6 cm)

(DCIH Classic Chimney Island Hoods 36, 42, & 54)

* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct run is 50 ft. ** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft. NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all Designer hoods.

30min. (76.2 cm)to36max. (91.4 cm)

66min. (167.6 cm)to72max. (182.9 cm)

36

(91.4 cm) NOTE: Optional duct cover sold separately.

(DCIH Classic Chimney Island Hoods)

NOTE: For best performance, it is recommended that the bottom of the hood be 30 (76.2 cm) to 36 (91.4 cm) above the countertop. These dimensions provide for safe and efficient operation of the hood.

DCIH Classic Chimney Island Hoods Description 36 42 54

Duct cover width 12 (30.5 cm) 12 (30.5 cm) 18 (45.7 cm)

Duct cover depth 12 (30.5 cm)

Duct cover height 16 (40.6 cm) or 28 (71.1 cm) or 40 (101.6 cm)

Number of lights 4 4 6

Number of filters 2 3 3

Interior ventilator kits VINV600 VINV600 VINV1200*

Exterior ventilator kits DEV900/1200* DEV900/1200*/1500** DEV1200*/1500**

In-line ventilator kits DIL900/1200 DIL900/1200 DIL1200

Interior duct size 7 (17.8 cm) 7 (17.8 cm) 10 (25.4 cm)

Exterior duct size 10 (25.4 cm)

InteriorMaximum amps 4.7 4.3 8.5

ExteriorMaximum amps 7.4/3.9 7.4/4.8/5.5 5.5/6.2

In-LineMaximum amps 4.7/6.6 4.7/6.6 7.3

Interior Ventilator Dimensions

18

Exterior Ventilator Dimensions

19

26-15/16 (68.4 cm)

12 (30.5 cm)

10 (25.4 cm) dia. duct location

1200 CFM Interior or Exterior 1500 CFM Exterior

54 models

18 (45.7 cm)

6 (15.2 cm)

120 V power supply

7 (17.8 cm)

15 (38.1 cm)

600 CFM Interior Ventillation Installation

36 & 42 Chimney Island

4-3/4 (12.1 cm)

4-3/4 (12.1 cm)

12 (30.5 cm)

A

7 (17.8 cm) dia. duct location

15 (38.1 cm)

12 (30.5 cm)

120 V power supply

A

36W. 17-15/16 (45.6 cm)

42W. 20-15/16 (53.2 cm)

26-15/16 (68.4 cm)

12 (30.5 cm)

10 (25.4 cm) dia. duct location

1200 CFM Interior or Exterior 1500 CFM Exterior

54 models

18 (45.7 cm)

6 (15.2 cm)

120 V power supply

7 (17.8 cm)

15 (38.1 cm)

4-3/4 (12.1 cm)

4-3/4 (12.1 cm)

12 (30.5 cm)

A

10 (25.4 cm) dia. duct location

15 (38.1 cm)

900 or 1200 CFM Exterior Ventillation Installation

36 & 42 Chimney Island

12 (30.5 cm)

120 V power supply

A

36W. 17-15/16 (45.6 cm)

42W. 20-15/16 (53.2 cm)

900 or 1200 CFM Exterior or In-Line Ventilator Installation for 36 & 42 models

900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation for 54 models

600 CFM Interior Ventilator Installation for 36 & 42 models

(DCIH Classic Chimney Island Hoods) (DCIH Classic Chimney Island Hoods)

Top view

Top view

Top view

Top view

1200 CFM Interior Ventilator Installation for 54 models

Clearance Dimensions

21

Dimensions & Specifications

20

24

(61.0 cm) B

9(22.9 cm)

21(53.3 cm)to33(83.8 cm)

A 12

(30.5 cm)

B (Hood width) 30W. 29-7/8 (75.9 cm) 36W. 35-7/8 (91.1 cm) 42W. 41-7/8 (106.4 cm) 48W. 47-7/8 (121.6 cm)

A (Duct cover width) 30W. 12 (30.5 cm) 36W. 12 (30.5 cm) 42W. 12 (30.5 cm) 48W. 20 (50.8 cm)

2 (5.1 cm)

13

(33.0 cm)

(DTWS Slim Traditional Wall Hoods 30, 36, 42, & 48)

* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct run is 50 ft. ** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft. NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all Designer hoods.

66min. (167.6 cm)to72max. (182.9 cm)

30min. (76.2 cm)to36max. (91.4 cm)

36

(91.4 cm)

(DTWS Slim Traditional Wall Hoods)

NOTE: For best performance, it is recommended that the bottom of the hood be 30 (76.2 cm) to 36 (91.4 cm) above the countertop. These dimensions provide for safe and efficient operation of the hood.

DTWS Slim Traditional Wall Hoods Description 30 36 42 48

Duct cover width 12 (30.5 cm) 12 (30.5 cm) 12 (30.5 cm) 20 (50.8 cm)

Duct cover depth 12 (30.5 cm)

Duct cover height 21 (53.3 cm) to 33 (83.8 cm)

Number of lights 2 2 2 3

Number of filters 2 2 3 3

Interior ventilator kits VINV300/600 VINV300/600 VINV600 VINV1200*

Exterior ventilator kits DEV900/1200* DEV900/1200* DEV900/1200* DEV1200*/1500**

In-line ventilator kits DIL900/1200 DIL900/1200 DIL900/1200 DIL1200

Interior duct size 7 (17.8 cm) 7 (17.8 cm) 7 (17.8 cm) 10 (25.4 cm)

Exterior duct size 10 (25.4 cm)

InteriorMaximum amps 2.8/3.8 2.8/3.8 3.8 7.3

ExteriorMaximum amps 6.6/3.9 6.6/3.9 6.6/3.9 4.3/5.1

In-LineMaximum amps 3.9/5.7 3.9/5.7 3.9/5.7 6.1

2322

120 V power supply

5-9/16 (14.3 cm)

A

5-1/8 (13.0 cm)

11 (27.9 cm)

8 (20.3 cm)* dia. duct location

1-1/8 (2.9 cm)

900 or 1200 CFM Exterior Ventilator Installation

30, 36 & 42 models

A

30W. 15-3/4 (40.0 cm)

36W. 18-3/4 (47.6 cm)

42W. 21-3/4 (55.2 cm)

120 V

7-7/8 (20.0 cm)

1-1/8 (2.9 cm)

6 (15.2 cm)

19 (48.3 cm)

1200 or 1500 CFM Exterior Ventilator Installation

48 models

23-15/16 (60.1 cm)

10 (25.4 cm) dia. duct location

900 or 1200 CFM Exterior or In-Line Ventilator Installation for 30, 36 & 42 models

900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation for 48 models

120 V power supply

5-9/16 (14.3 cm)

A

5-1/8 (13.0 cm)

11 (27.9 cm)

7 (17.8 cm) dia. duct location

300 or 440 CFM** Interior Ventilator Installation 30, 36, & 42 models

1-1/8 (2.9 cm)

A

30W. 15-3/4 (40.0 cm)

36W. 18-3/4 (47.6 cm)

42W. 21-3/4 (55.2 cm)

300 or 600 CFM Interior Ventilator Installation for 30, 36, & 42 models

(DTWS Slim Traditional Wall Hoods) (DTWS Slim Traditional Wall Hoods)

Exterior Ventilator Dimensions Interior Ventilator Dimensions

10 (25.4 cm) dia. duct location

120 V

7-7/8 (20.0 cm)

1-1/8 (2.9 cm)

6 (15.2 cm)

19 (48.3 cm)

880 CFM Interior Ventilator Installation

48 models

23-15/16 (60.1 cm)

Top view

Top view

Top view

Top view

1200 CFM Interior Ventilator Installation for 4 models

* 8 to 10 transition to be acquired locally.

2524

* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct run is 50 ft. ** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft. NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all Designer hoods.

24

(61.0 cm)

B

A

18(45.7 cm)

12(30.5 cm)

12

(30.5 cm)

B (Hood width) 30W. 29-7/8 (75.9 cm) 36W. 35-7/8 (91.1 cm) 42W. 41-7/8 (106.4 cm) 48W. 47-7/8 (121.6 cm)

A (Duct cover width) 30W. 29-7/8 (75.9 cm) 36W. 35-7/8 (91.1 cm) 42W. 41-7/8 (106.4 cm) 48W. 47-7/8 (121.6 cm)

2(5.1 cm)

Ledge models only

25-1/2

(64.8 cm)

Ledge models o nly

(DTWN Tall Traditional Wall Hoods Ledgeless 30, 36, 42, & 48)

Dimensions & Specifications Clearance Dimensions

30min. (76.2 cm)to36max. (91.4 cm)

66min. (167.6 cm)to72max. (182.9 cm)

36

(91.4 cm)

NOTE: Optional duct cover sold separately.

(DTWN Tall Traditional Wall Hoods)

NOTE: For best performance, it is recommended that the bottom of the hood be 30 (76.2 cm) to 36 (91.4 cm) above the countertop. These dimensions provide for safe and efficient operation of the hood.

DTWN Tall Traditional Wall HoodsLedgeless Description 30 36 42 48

Duct cover width 29-7/8 (75.9 cm) 35-7/8 (91.1 cm) 41-7/8 (106.4 cm) 47-7/8 (121.6 cm)

Duct cover depth 12 (30.5 cm)

Duct cover height 12 (30.5 cm)

Number of lights 2 2 2 3

Number of filters 2 2 3 3

Interior ventilator kits VINV300/600/1200* VINV300/600/1200* VINV600/1200* VINV1200*

Exterior ventilator kits DEV900/1200* DEV900/1200* DEV900/1200* DEV1200*/1500**

In-line ventilator kits DIL900/1200 DIL900/1200 DIL900/1200 DIL1200

Interior duct size 7 (17.8 cm) 7 (17.8 cm) 7 (17.8 cm) 10 (25.4 cm)

Exterior duct size 10 (25.4 cm)

InteriorMaximum amps 2.8/3.8/6.8 2.8/3.8/6.8 3.8/6.8 7.3

ExteriorMaximum amps 6.6/3.9 6.6/3.9 6.6/3.9 4.3/5.1

In-LineMaximum amps 3.9/5.7 3.9/5.7 3.9/5.7 6.1

Exterior Ventilator Dimensions

27

Interior Ventilator Dimensions

26

23-15/16 (60.8 cm)

5/8 (1.6 cm)

18-3/4 (47.6 cm)

Interior Vent VIV1200 48 models

8-3/8 (21.3 cm)

120 V

9-1/2 (24.1 cm)

9-1/4 (23.5 cm)

5-1/2 (14.0 cm)

Tall Traditional with Ledge

Tall Traditional Ledgeless

10 (24.8 cm) dia. duct location

18-3/4 (47.6 cm)

4-5/8 (11.7 cm) 9-1/8

(23.2 cm)

A

9-5/8 (24.4 cm)

9-3/8 (23.8 cm)

30, 36, & 42 Interior Vent - VIV300, VIV600 or VIV1200

Tall Traditional with Ledge

120 V

Tall Traditional Ledgeless

A (Duct diameter)

VIV300 7 (17.8 cm)/10 (25.4 cm)

VIV600 7 (17.8 cm)/10 (25.4 cm)

VIV1200 10 (25.4 cm)

23-15/16 (60.8 cm)

Exterior Vent VEV1200 or VEV1500 48 models

8-3/16 (20.7 cm)

5-15/16 (15.1 cm)

6-5/8 (16.8 cm)

3 (7.62 cm)

2-1/2 (6.35 cm)

Tall Traditional with Ledge

120 V

Tall Traditional Ledgeless

10 (24.8 cm) dia. duct location

A

5-5/16 (15.1 cm)

3 (7.6 cm)

2-1/2 (6.4 cm)

Tall Traditional with Ledge

Tall Traditional Ledgeless

120 V

10 (24.8 cm) dia. duct location

30, 36, & 42 Exterior Vent - VEV900 or VEV1200

8-1/4 (20.9 cm)

6-7/16 (16.4 cm)

A (Duct diameter)

30W. 14-15/16 (37.9 cm)

36W. 17-15/16 (45.6 cm)

42W. 20-15/16 (56.2 cm)

900 or 1200 CFM Exterior or In-Line Ventilator Installation for 30, 36, & 42 models

900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation for 48 models

300, 600, or 1200 CFM Interior Ventilator Installation for 30, 36, & 42 models

(DTWN Tall Traditional Wall Hoods) (DTWN Tall Traditional Wall Hoods)

1200 CFM Interior Ventilator Installation for 48 models

Top view

Top view

Top view

Top view

2928

Dimensions & Specifications (DBCV Wall Custom Ventilator System)

* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct run is 50 ft. ** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft. NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2- wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all Designer hoods.

B*

A*

Bottom Cutout Dimensions

*For best results, center the unit over the burners of the cooking product (front to back; right to left).

Make sure the back wall of the custom hood canopy is flush with the cutout so the ventilator system may be mounted as shown on page 29.

Wall Hoods Description A (Hood Width) B (Hood Depth)

30 W. 28-11/16 (72.9 cm) 16-1/2 (41.9 cm) 36 W. 34-11/16 (88.1 cm) 16-1/2 (41.9 cm) 42 W. 40-11/16 (103.4 cm) 16-1/2 (41.9 cm) 48 W. 46-11/16 (118.6 cm) 16-1/2 (41.9 cm)

A B

Custom Hood Canopy

1) Position ventilator system inside of the custom hood canopy and center it front to back and left to right.

2) Bottom mounting holes fasten ventilator system to bottom of custom hood canopy with the screws provided.

Built-In Ventilator System

3) OPTIONAL Rear mounting holes fasten ventilator system to rear of custom hood canopy.

Installing Hood Canopy (Custom Hood Canopy Cutouts)

DBCV Wall Custom Ventilator System Description 30 36 42 48

Number of lights 2 2 2 3

Number of filters 2 2 3 3

Interior ventilator kits VINV300/600 VINV300/600 VINV600 VINV1200*

Exterior ventilator kits DEV900/1200* DEV900/1200* DEV900/1200* DEV1200*/1500**

In-line ventilator kits DIL900/1200 DIL900/1200 DIL900/1200 DIL900/1200

Interior duct size 7 (17.8 cm) 7 (17.8 cm) 7 (17.8 cm) 10 (25.4 cm)

Exterior duct size 10 (25.4 cm)

InteriorMaximum amps 2.8/3.8 2.8/3.8 3.8 6.8

ExteriorMaximum amps 6.6/3.9 6.6/3.9 6.6/3.9 4.3/5.1

In-LineMaximum amps 3.9/5.7 3.9/5.7 3.9/5.7 6.1

3130

Built-In Wall Custom Ventilator System Dimensions (30W./36W./42W. DBCV Models)

900 or 1200 CFM External or In-Line Ventilator Installation

300 or 600 CFM** Internal Ventilator Installation

A 30 W. 29-5/8 (75.2 cm) 36 W. 35-5/8 (90.5 cm) 42 W. 41-5/8 (105.7 cm)

11-3/4 (29.8 cm)

1 (2.5 cm)

11 (27.9 cm)

8 (20.3 cm)

5 (12.7 cm)

11-3/4 (29.8 cm)

1 (2.5 cm)

11 (27.9 cm)

7 (17.8 cm)

5 (12.7 cm)

900 or 1200 CFM External or In-Line Ventilator Installation

(10 diameter duct required)

300 or 600 CFM** Internal Ventilator Installation

(7 diameter duct required)

B C

A

16 (40.6 cm)

6-1/8 (15.6 cm)

16 (40.6 cm) 6

(15.2 cm) 2

(5.1 cm)

120V

3/4 (1.9 cm)

7 (17.8 cm) Round for External Ventilation Duct*

B C

A

17-1/4 (43.8 cm)

6-1/8 (15.6 cm)

16 (40.6 cm) 6

(15.2 cm) 2

(5.1 cm)

120V

3/4 (1.9 cm)

8 (20.3 cm) Round for External Ventilation Duct*

*Must purchase 8 diameter to 10 diameter transition locally. Transition should be installed past the duct cover.

**300 CFM ventilator kit for installation with 30 W. and 36 W. hoods only.

B 30 W. 28-3/8 (72.1 cm) 36 W. 34-3/8 (87.3 cm) 42 W. 40-3/8 (102.6 cm)

C 30 W. 14-13/16 (37.6 cm) 36 W. 17-13/16 (45.2 cm) 42 W. 20-13/16 (52.9 cm)

Clearance Dimensions

30min. (76.2 cm)to36max. (91.4 cm)

66min. (167.6 cm)to72max. (182.9 cm)

36

(91.4 cm)

(Custom Hood)

(DBCV Wall Custom Ventilator System)

NOTE: For best performance, it is recommended that the bottom of the hood be 30 (76.2 cm) to 36 (91.4 cm) above the countertop. These dimensions provide for safe and efficient operation of the hood.

3332

Built-In Wall Custom Ventilator System Dimensions (48W. DBCV Models)

1200 CFM Internal and 900, 1200 or 1500 CFM External or In-Line Ventilator Installation

11-3/4 (29.8 cm)

1 (2.5 cm)

11 (27.9 cm)

10 (25.4 cm)

5 (12.7 cm)

1200 CFM Internal and 900, 1200 or 1500 CFM External Ventilator Installation

(10 diameter duct required)

17-1/4 (43.8 cm)

6-1/8 (15.6 cm)

16 (40.6 cm) 6

(15.2 cm) 2

(5.1 cm)

120V

3/4 (1.9 cm)

10 (25.4 cm) Round for External Ventilation Duct*

47-5/8 (121.0 cm)

46-5/8 (118.4 cm)

23-13/16 (60.5 cm)

Dimensions & Specifications (DICV Island Custom Ventilator Systems 36, 42, & 54)

* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct run is 50 ft. ** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft. NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2- wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all Designer hoods.

B*

A*

Bottom Cutout Dimensions

*For best results, center the unit over the burners of the cooking product (front to back; right to left).

Island Hoods Description A (Hood Width) B (Hood Depth)

36 W. 34-11/16 (88.1 cm) 21-1/2 (54.6 cm) 42 W. 40-11/16 (103.4cm) 21-1/2 (54.6 cm) 54 W. 52-11/16 (133.8 cm) 21-1/2 (54.6 cm)

Make sure the back wall of the custom hood canopy is flush with the cutout so the ventilator system may be mounted as shown on page 34.

DICV Island Custom Ventilator System Description 36 42 54

Number of lights 4 4 6

Number of filters 2 3 3

Interior ventilator kits VINV600 VINV600 VINV1200*

Exterior ventilator kits DEV900/1200* DEV900/1200*/1500** DEV1200*/1500**

In-line ventilator kits DIL900/1200 DIL900/1200 DIL1200

Interior duct size 7 (17.8 cm) 7 (17.8 cm) 10 (25.4 cm)

Exterior duct size 10 (25.4 cm)

InteriorMaximum amps 4.0 4.0 6.9

ExteriorMaximum amps 7.5/5.2 7.5/5.2/6.0 5.2/6.0

In-LineMaximum amps 4.8/7.0 4.8/7.0 7.0

3534

A B

Custom Hood Canopy

1) Position ventilator system inside of the custom hood canopy and center it front to back and left to right.

2) Bottom mounting holes fasten ventilator system to bottom of custom hood canopy with the screws provided.

Built-In Ventilator System

3) OPTIONAL Rear mounting holes fasten ventilator system to rear of custom hood canopy.

Installing Hood Canopy (Custom Hood Canopy Cutouts)

Clearance Dimensions

30min. (76.2 cm)to36max. (91.4 cm)

66min. (167.6 cm)to72max. (182.9 cm)

36

(91.4 cm)

(Custom Hood)

(DICV Island Custom Ventilator System)

NOTE: For best performance, it is recommended that the bottom of the hood be 30 (76.2 cm) to 36 (91.4 cm) above the countertop. These dimensions provide for safe and efficient operation of the hood.

3736

Built-In Island Custom Ventilator System Dimensions (36W./42W. DICV Models)

900, 1200 or 1500 CFM External** or In-Line Ventilator Installation

300 or 600 CFM** Internal Ventilator Installation

11 (27.9 cm)

8 (20.3 cm)

5 (12.7cm)

11-3/4 (29.8 cm)

1 (2.5 cm)

11 (27.9 cm)

7 (17.8 cm)

5 (12.7cm)

11-3/4 (29.8 cm)

1 (2.5 cm)

900, 1200 or 1500 CFM External** or In-Line Ventilator Installation (10 diameter duct required)

300*** or 600 CFM** Internal Ventilator Installation

(7 diameter duct required)

120V 7 (17.8 cm) Round

for Ventilation Duct*

3/4 (1.9 cm)

B C

A

16 (40.6 cm) 6

(15.2 cm) 2

(5.1 cm)

11-1/8 (28.3 cm)

21 (53.3 cm)

22-1/4 (56.5 cm)3/4

(1.9 cm)

120V

8 (20.3 cm) Round for Ventilation Duct*

11-1/8 (28.3 cm)

21 (53.3 cm)

22-1/4 (56.5 cm)

B

C

A

6 (15.2 cm)

2 (5.1 cm)

16 (40.6 cm)

*Must purchase 8 diameter to 10 diameter transition locally. Transition should be installed past the duct cover.

A 36 W. 35-5/8 (90.5 cm) 42 W. 41-5/8 (105.7 cm)

***300 CFM ventilator kit for installation with 30 W. and 36 W. hoods only. **1500 CFM external ventilator kit for installation with 42 W. island hood only.

B 36 W. 34-5/8 (87.9 cm) 42 W. 40-5/8 (103.2 cm)

C 36 W. 17-13/16 (45.2 cm) 42 W. 20-13/16 (52.9 cm)

Built-In Island Custom Ventilator System Dimensions (54W. DICV Models)

1200 CFM Internal and 900, 1200 or 1500 CFM External or In-Line Ventilator Installation

11 (27.9 cm)

10 (25.4 cm)

5 (12.7cm)

11-3/4 (29.8 cm)

1 (2.5 cm)

1200 CFM Internal and 900, 1200 or 1500 CFM External or In-Line Ventilator Installation

(10 diameter duct required)

10 (25.4 cm) Round for Ventilation Duct

120V

3/4 (1.9 cm)

11-1/8 (28.3 cm)

21 (53.3 cm)

22-1/4 (56.5 cm)

10 (25.4 cm)

24 (61.0 cm)

26-13/16 (68.1 cm)

52-5/8 (133.7 cm)

53-5/8 (136.2 cm)

2 (5.1 cm)

3938

Planning Information

Plan where the duct work will be located. Install proper-sized duct work, roof, or wall cap for the type of blower you are using. Adjust your measurements for various heights of ceilings, soffits, cabinets, or ranges/rangetops.

Proper installation of ducting is extremely important to ensure maximum performance from any ventilation product. All CFMs are based on tests at 0.1 static pressure: without applying static pressure, CFM would be greatly overstated.

Straight runs and gradual turns are best; for example, each 90 elbow is equivalent to 5-10 feet (1.52-3.05 cm) of straight run.

Never use flexible duct; it creates back pressure/air turbulence and greatly reduces performance.

Proper performance is dependent on proper ducting; make sure that a qualified and trained installer is used.

Check with a qualified and trained installer or local codes for makeup air requirement, if any.

Max. amp rating for hoods includes recommended ventilator kit rating; all products must be hard wired direct with 2-wire with ground.

Check Framing

NOTE: Because of the weight of the hood make sure that the mounting screws are driven into the framing and not just the drywall. It may be necessary to drill additional holes in the canopy for proper alignment. Some hoods require a locally supplied wood strip for mounting. Check installation procedure of your hood on page 34 to determine if a wood strip is required.

Electrical Supply Run 120 VAC electrical wiring from service panel to installation location. See specification pages for the maximum amp requirements.

Roof cap

7 round duct

Duct cover or soffit

300 or 600 CFM single blower interior-power

typical ductwork

Hood

Roof cap

10 round duct

Duct cover or soffit

1200 CFM single blower interior power

typical ductwork

Hood

Exterior blower

10 round duct

Duct cover or soffit

900, 1200, or 1500 CFM

exterior power typical ductwork

Hood

Duct Duct cover or soffit

Wall installation exterior power

typical ductwork

NOTE: Wall exhaust must be a minimum of 24 (61.0 cm) from ground. This may vary depending on local codes and geographic location.

Hood

Wall cap

Installation (DCH 12H. Classic Chimney Wall Hoods w/Standard Ventilator and DPPV Custom Power Packs w/Standard Ventilator)

1

Check damper for unrestricted movement, adjust if necessary.

2

3

Attach transition to damper. Seal with aluminum tape.

Flip hood over and remove electrical box cover.

1

4 2

1 5

Insert 6 of electrical wiring through the top of vent hood and secure using wiring restrain. Refer to local

codes.

Slide duct over transition and tape around joint.

W A R N I N G TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

4140

CAUTION: If not using a duct cover, using screws provided make sure top mounting screws are secured into soffit or cabinet frame. Use additional mounting

screws, if necessary.

Connect black to black, white to white, and the green/bare wire under the green screw.

NOTE: Housing wiring must be properly installed for wiring to be correct when wiring unit.

5/16 nut driver

BLACK

BLACK

WHITE

WHITE

GREEN

BARE OR GREEN7

Replace electrical box cover. Make connection to breaker box.

1

2 3

9

1 1

2

8

Slide spacer front over front lip. Push spacer rear up, then slide back over rear lip.

Slide filter front over front lip. Push filter rear up, then slide back over rear lip.

2

1

3

10 3 4

2

Place duct cover top inside duct cover base and lower until desired height is found. Mark height. Use the retaining nuts and bolts to fasten in place from the inside and remove tape.

Slide duct cover in place and fasten from inside canopy using the sheet metal screws provided.

1 2

Measure distance from ceiling to canopy. Tape to avoid scratching.

Duct Cover Option (DCH 12H. Classic Chimney Wall Hoods w/Standard Ventilator)

CAUTION: Secure vent hood to wall using screws provided. Use additional mounting screws and wall

anchors, if necessary.

6

5/16 nut driver

2

1

3

11

Slide filter front over front lip. Push filter rear up, then slide back over rear lip.

42 43

CAUTION: Secure vent hood. Make sure mounting screws are secured into framing using additional mounting screws and wall anchors, if necessary.

Connect black to black, white to white, and the green/bare wire under the green screw.

NOTE: Housing wiring must be properly installed for wiring to be correct when wiring unit.

7

5/16 nut driver

BLACK

BLACK

WHITE

WHITE

GREEN

BARE OR GREEN83 4

5

Attach with screws and lock washers provided. Attach with screws.

Remove electrical box cover.

1

6

2

Flip hood over. Insert 6 of electrical wiring through the top of vent hood and secure using wiring restrain. Refer

to local codes.

Replace electrical box cover. Make connection to breaker box.

1 1

2

9

10

Slide filter front over front lip. Push filter rear up, then slide back over rear lip.

2

1 11

3

Assemble brackets to mesh filters and insert charcoal filters.

2

1 2

Remove damper and discard with transition. Turn recirculating unit upside down. Place vent hood upside down on recirculating unit.

Installation (DCH 12H. Classic Chimney Wall Hoods w/Recirculating Kit)

W A R N I N G TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

4544

1-13/16

(4.6 cm) 1-1/2x 3/4

(3.8 cm) x (1.9 cm) wood strip

1 5/16 nut driver

Slot for wood strip

2 5/16 nut driver

Measure down 1-13/16 (4.6 cm) from desired height of hood and secure 1-1/2 x 3/4 wood strip (not

included) to wall using screws provided.

Use additional mounting screws to secure hood to wood strip.

Installation (DCWH/DCWN/DCWL Classic Chimney & DTWN Tall Traditional Wall Hoods)

3 5/16 nut driver

5/16 nut driver

CAUTION: Secure vent hood to wall using screws provided. Make sure mounting screws are secured into frame. Use additional mounting screws and wall anchors, if necessary.

CAUTION: If not using a duct cover, using screws provided make sure top mounting screws are secured into soffit or cabinet frame. Use additional mounting screws, if necessary.

To install ventillation kit refer to ventillation kit

installation instructions.

1

2 3

4

Slide filter front over front lip. Push filter rear up, then slide back over rear lip.

1

2 3

5

Slide spacer front over front lip. Push spacer rear up, then slide back over rear lip.

1

2 3

6

Slide filter front over front lip. Push filter rear up, then slide back over rear lip.

1 2

Measure distance from ceiling to canopy. Tape to avoid scratching.

Duct Cover Option (DCWH/DCWN/DCWL Classic Chimney Wall Hoods)

Slide filter front over front lip. Push filter rear up, then slide back over rear lip.

2

1

3

13

Slide spacer front over front lip. Push spacer rear up, then slide back over rear lip.

2

1

3

12

4746

Installation (DTWS Slim Traditional)

1

1

2 2

Flip hood over. Remove electrical box cover.

Insert 6 of electrical wiring through the top of vent hood and secure using wiring restrain. Refer to local codes.

3

5/16 nut driver

5/16 nut driver

CAUTION: Using screws provided, secure vent hood to wall. Make sure mounting screws are secured into frame. Use additional mounting screws and wall anchors, if necessary.

CAUTION: If not using a duct cover, use screws provided and make sure top mounting screws are secured into soffit or cabinet frame. Use additional

mounting screws, if necessary.

BLACK

BLACK

WHITE

WHITE

GREEN

BARE OR GREEN4

1 1

2

5

Connect black to black, white to white, and the green/bare wire under the green screw.

NOTE: Housing wiring must be properly installed for wiring to be correct when wiring unit.

Replace electrical box cover. Make connection to breaker box.

1 2 2

Measure distance from ceiling to canopy. Slide duct cover in place and fasten from inside canopy using the sheet metal screws provided.

Duct Cover Option (DTWN Tall Traditional Wall Hoods)

To install ventillation kit refer to ventillation kit

installation instructions.

3 4

2

Place duct cover top inside duct cover base and lower until desired height is found. Mark height. Use the retaining nuts and bolts to fasten in place from inside and remove tape.

Slide duct cover in place and fasten from inside canopy using the sheet metal screws provided.

W A R N I N G TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

4948

3 4

2

Place duct cover top inside duct cover base and lower until desired height is found. Mark height. Use the retaining nuts and bolts to fasten in place from inside and remove tape.

Slide duct cover in place and fasten from inside canopy using the sheet metal screws provided.

2

1

3

7

1 2

1

2 3

8

Slide filter front over front lip. Push filter rear up, then slide back over rear lip.

Slide spacer front over front lip. Push spacer rear up, then slide back over rear lip. NOTE: Number of spacers

and baffles may vary by model.

Duct Cover Option (DTWS Slim Traditional Wall Hoods)

Tape to avoid scratching.Measure distance from ceiling to canopy.

1

2 3

6

Slide filter front over front lip. Push filter rear up, then slide back over rear lip.

5150

4 5/16 nut driver

Attach canopy to duct cover/soffit. From inside of hood, seal top of hood to duct with aluminum tape.

3

To install ventillation kit refer to ventillation kit

installation instructions.

Run duct work down to bottom edge of duct cover/soffit and secure in place. Make sure the duct

does not stick down past the cover.

1

2 3

5

Slide filter front over front lip. Push filter rear up, then slide back over rear lip.

2

1

3

6

Slide spacer front over front lip. Push spacer rear up, then slide back over rear lip. NOTE: Number of spacers

and baffles may vary by model.

2

1

3

7

Slide filter front over front lip. Push filter rear up, then slide back over rear lip.

Check framing where cutout will be. NOTE: 200 lb. limit.

Cut appropriate size hole in ceiling. Either 7 or 10 depending on your specific unit and ventilator kit.

1 2

Mounting options:

Using duct cover with ceiling mounting bracket. (Option A)

Using threaded rod for additional support. (Option B)

Attaching hood directly to soffit or duct cover.

(Skip to step 3)

NOTE: It is recommended to follow option A or B, however both arent necessary.

Installation (DCIH Classic Chimney Island Hoods)

A1

Attach duct cover to optional ceiling mounting bracket.

Attach duct cover to ceiling. The ceiling bracket can be hidden by using a locally supplied trim.

A2 5/16 nut driver

B1

Additional support option. Drill holes in all four corners for threaded rod and run rods from hood to ceiling.

52 53

Service & Parts Only authorized replacement parts may be used in performing service on the appliance. Do not repair or replace any part of the appliance unless specifically recommended in the manual. All other servicing should be referred to a qualified technician.

Record the following information indicated below. You will need it if service is ever required. The serial number and model number for your appliance are located on the identification plate mounted on the inside of the hood canopy.

Model number

_________________________________________

Serial number

_________________________________________

Date of purchase

_________________________________________

Date installed

_________________________________________

Dealer's name

_________________________________________

Address

_________________________________________

Service & Registration

Manualsnet FAQs

If you want to find out how the DCWN3644 Viking works, you can view and download the Viking DCWN3644 Hood Installation Guide on the Manualsnet website.

Yes, we have the Installation Guide for Viking DCWN3644 as well as other Viking manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Installation Guide should include all the details that are needed to use a Viking DCWN3644. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Viking DCWN3644 Hood Installation Guide is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Viking DCWN3644 Hood Installation Guide consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Viking DCWN3644 Hood Installation Guide free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Viking DCWN3644 Hood Installation Guide, simply download the document to your computer. Once downloaded, open the PDF file and print the Viking DCWN3644 Hood Installation Guide as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.