IMPORTANT

3

Please Read and FollowTable of Contents

Before beginning, please read these instructions completely and carefully.

Do not remove permanently affixed labels, warnings, or plates from product. This may void the warranty.

Please observe all local and national codes and ordinances.

The installer should leave these instructions with the consumer who should retain for local inspectors use and for future reference.

This outdoor cooking appliance shall be only used outdoors and shall not be used in a building, garage or any other enclosed area.

Installation must conform with local codes or in the absence of codes, the National Fuel Gas Code, ANSI Z223.1/NFPA 54.

In Canada: Installation must be in accordance with the current CSA-B149.1, Natural Gas and Propane Installation Code or CSA-B149.2, Propane Storage and Handling Code and/or local codes. For units with an external electrical source, when installed, must be electrically grounded in accordance with local codes or with the National Electrical code ANSI/NFPA 70, or Canadian Electrical code, CSA C22.1.

IMPORTANT Please Read and Follow

WARNING EXCESSIVE WEIGHT HAZARD

Use two or more people to move and install this

unit. Failure to follow this instruction can result

in back or other injury.

FOR YOUR SAFETY If not installed, operated and maintained in

accordance with the manufacturers instructions,

this product could expose you to substances in

fuel or fuel combustion which can cause death

or serious illness and which are known to cause

cancer, birth defects or other reproductive harm.

For example, benzene is a chemical which is

part of the gas supplied to the cooking product.

It is consu-incomplete combustion. Properly

adjusted burners with a bluish rather than yellow

flame minimize incomplete combustion.

WARNING This outdoor gas grill is not intended to be

installed inside a home or on recreational

vehicles and/or boats.

WARNING Keep electrical supply cord and the fuel supply

hose away from heated surfaces.

WARNING This appliance is not fused. Installer must install

a ground fault interrupt.

CAUTION Conversions should only be performed by an

authorized service technician.

WARNING ELECTRICAL SHOCK HAZARD

This appliance is equipped with a 3 (91.4 cm)

3-prong power cord with a grounding plug for

your protection against shock hazard and should

be plugged directly into a properly grounded

receptacle. Do not cut or remove the grounding

prong from this plug. This unit is not fused and

installer must install a GFI. Unit must be

grounded in accordance with local codes or with

the National Electrical Code ANSI/NFPA 70, or

the Canadian Electrical Code, CSA C22.1.

CAUTION Before placing into operation, always check for

gas leaks with a soapy water solution. DO NOT

USE AN OPEN FLAME TO CHECK FOR LEAKS.

DANGER WHAT TO DO IF YOU SMELL GAS:

Shut off gas to the appliance.

Extinguish any open flame.

Open lid.

If odor continues, keep away from the

appliance, immediately call your gas supplier

or your fire department.

FOR YOUR SAFETY DO NOT store or use gasoline or other

flammable vapors and liquids in the vicinity of

this or any other appliance.

Any LP cylinder not connected for use shall

not be stored in the vicinity of this or any other

appliance.

Important Safety Instructions __________________________________________________________2 Dimensions (30" & 36" 100 and 300 Series)_____________________________________________4 Specifications (30" & 36" 100 and 300 Series)___________________________________________5 Dimensions (30" & 42" 500 Series Grills) _______________________________________________6 Specifications (30" & 42" 500 Series Grills) _____________________________________________7 Dimensions (54" 500 Series Grill) ______________________________________________________8 Specifications (54" 500 Series Grill) ____________________________________________________9 General Information ________________________________________________________________10 Clearance Dimensions (100 and 300 Series)____________________________________________12 Clearance Dimensions (500 Series)____________________________________________________14 Cutout Dimensions (100 and 300 Series) ______________________________________________17 Cutout Dimensions (500 Series) ______________________________________________________19 Ventilation for Built-In Installations ____________________________________________________22 Gas and Electrical Connection _______________________________________________________23 Natural Fixed Piping Connection _____________________________________________________24 LP/Propane Fixed Piping Connection _________________________________________________25

Built-In Installations _____________________________________________________________26 LP/Propane Tank Requirements ______________________________________________________26 LP/Propane Tank Connection ________________________________________________________27 Leak Testing _______________________________________________________________________28 Burner Adjustment__________________________________________________________________30 Rotisserie System___________________________________________________________________32 Final Preparation ___________________________________________________________________33 Performance Checklist ______________________________________________________________33 Service & Registration_______________________________________________________________34

2

Specifications (30" & 36" 100 and 300 Series)

5

Dimensions (30" & 36" 100 and 300 Series)

4

35-7/8"(91.1 cm) 29"

(73.6 cm)

34-1/4"(86.9 cm)

17-3/16"(43.7 cm)

10-5/8(26.9 cm)

30-1/16"(76.4 cm)

29"

(73.6 cm)

27-9/16"(70.0 cm)

17-3/16"(43.7 cm)

10-5/8"(26.9 cm)

30" 100 and 300 Series Grill

36" 100 and 300 Series Grill

30W. & 36W. 100 and 300 Series Grills Description VGBQ1302/VGBQ3302RE VGBQ1363/VGBQ3363RE

Cutout width 29-1/4 (74.2 cm)

35-1/4 (89.5 cm)

Cutout depth 24 3/8" (67.9 cm)

Cutout height 10 1/8" (25.7 cm)

Overall width 30 (76.2 cm)

35-7/8 (91.1 cm)

Overall depth 29 (73.6 cm)

Gas requirements Natural: standard residential 1/2 (1.3 cm) ID gas service line. LP/Propane: Equipped with high capacity hose/regulator assembly for

connection to standard 5gal, 20 lb. LP/Propane gas cylinder with Type 1, QCC-1 connection or standard residential 1/2 (1.3 cm) ID gas service line.

Electrical requirements

100 Series Models: 9 volt DC battery for electronic ignition

300 Series Models: 120VAC/60HZ - 3 ( 91.4 cm) power cord supply cord with 3-prong grounded

plug attached to grill

120VAC/60HZ - 2 (61.0 cm) power cord supply cord with 3-prong grounded plug attached to rotisserie motor

Grill burner rating 25,000 BTU Nat./22,500 BTU LP (7.3 kW Nat./6.5 kW LP)

Rotisserie burner rating (300 Series only)

(1) 15,000 BTU Nat./13,500 BTU LP (4.4 kW Nat./4.0 kW LP)

Approximate shipping weight

325 lbs. (147 kg)

340 lbs. (154 kg)

*Rotisserie available in 300 Series Models Only

NOTE: An insulated jacket (INJK-purchased separately) is required when installing either a 100 or 300 series grill in combustible type material.

30W & 42W 500 Series Grills

Description VGBQ53002RE VGBQ54203RE/ VGIQ54203RE

Cutout width 28-5/8 (72.7cm) 40-1/4 (102.2cm)

Cutout depth 28 (71.1 cm)

Cutout height 10-1/4 (26.0 cm)

Overall width 29-1/2 (74.9 cm) 41-3/16 (104.6 cm)

Overall depth 32-3/4 (83.2 cm)

Gas requirements Natural: standard residential 1/2 (1.3 cm) ID gas service line.

LP/Propane: equipped with high capacity hose/regulator assembly for

connection to standard 5gal, 20 lb. LP/Propane gas cylinder with

Type 1, QCC-1 connection or standard residential 1/2 (1.3 cm)

ID gas service line.

Electrical requirements

120VAC/60HZ - 3 ( 91.4 cm) power cord supply cord with 3-prong grounded plug attached to grill

120VAC/60HZ - 2 (61.0 cm) power cord supply cord with 3-prong grounded plug attached to rotisserie motor

Grill burner rating 29,000 BTU Nat./28,000 BTU LP (7.3 kW Nat./6.5 kW LP)

TruSear burner rating (If applicable)

NA 30,000 BTU Nat./LP (8.3 kW Nat./LP)

Rotisserie burner rating 15,000 BTU Nat./13,500 BTU LP (4.4 kW Nat./4.0 kW LP)

Approximate shipping weight

325 lbs. (147 kg

350 lbs. (159 kg)

76

Specifications (30" & 42" 500 Series Grills)Dimensions (30" & 42" 500 Series Grills)

41-3/16(104.6 cm) 32-3/4

(83.2 cm)

41-3/16(104.6 cm)

16-5/8(42.4 cm)

10-1/4(26.0 cm)

29-1/2(74.9 cm) 32-3/4

(83.2 cm)

29-1/2(74.9 cm)

16-5/8(42.4 cm)

10-1/4(26.0 cm)

30" 500 Series Grill

42" 500 Series Grill

98

54W 500 Series Grills Description VGBQ55404RE/VGIQ55404RE

Cutout width 52-1/4 (132.7 cm)

Cutout depth 28 (71.1 cm)

Cutout height 10-1/4 (26.0 cm)

Overall width 53-3/16 (135.1 cm)

Overall depth 32-3/4 (83.2 cm)

Gas requirements Natural: standard residential 1/2 (1.3 cm) ID gas service line.

LP/Propane: equipped with high capacity hose/regulator assembly for connection to standard 5gal, 20 lb. LP/Propane gas cylinder with Type 1, QCC-1 connection or standard residential 1/2 (1.3 cm) ID gas service line.

Electrical requirements 120VAC/60HZ - 3 ( 91.4 cm) power cord supply cord with 3-prong grounded plug attached to grill

120VAC/60HZ - 2 (61.0 cm) power cord supply cord with 3-prong grounded plug attached to rotisserie motor

Grill burner rating 29,000 BTU Nat./28,000 BTU LP (7.3 kW Nat./6.5 kW LP)

TruSear burner rating (If applicable)

30,000 BTU Nat./LP (8.3 kW Nat./LP)

Rotisserie burner rating 15,000 Nat./13,500 BTU LP (4.4 kW Nat./4.0 kW LP)

Approximate shipping weight

490 lbs. (222 kg)

53-3/16(135.1 cm) 32-3/4

(83.2 cm)

50(127 cm)16-5/8(42.4 cm)

10-1/4(26.0 cm)

54 500 Series Grill

Specifications (54" 500 Series Grill)Dimensions (54" 500 Series Grill)

General Information A minimum of 6 (15.2 cm) from the sides,

or a minimum of 8 (20.3 cm) from the right side if there is a rotisserie motor and a minimum of 24 (61.0 cm) from the back must be maintained from the grill above the cooking surface to adjacent vertical combustible construction. The grill is not to be located under overhead unprotected combustible construction. NOTE: An insulated jacket (INJK- purchased separately) is required when installing either a 100 or 300 series grill in combustible type material.

Note that the grill exhausts combustion products and cooking greases to the back. NEVER locate the grill in a location where the exhaust is directed at a window, less than 24 (61.0 cm) to combustible material or any surface that is difficult to clean.

A minimum of 3 (7.6 cm) clearance from the back of the grill with a canopy and a minimum of 6 (15.2 cm) from the back of the grill without a canopy to non- combustible construction is required for the purpose of allowing the lid to open fully and for proper ventilation. It is desirable to allow at least 6 side clearance to non-combustible construction above the cooking surface for counter space. If using the rotisserie option, the space is essential for motor and skewer clearance. The grill can be placed directly adjacent to combustible and/or non- combustible construction below the cooking surface. However, clearances from non-combustible materials are not part of the ANSI Z21.58 scope and are not certified by CSA. Clearances to non- combustible materials must be approved by the authority having jurisdiction.

When determining a suitable location for the grill, take into account concerns such as exposure to wind, proximity to traffic paths and keeping gas supply lines as short as possible. Locate the grill only in a well-ventilated area. Never locate the grill in a building, garage, shed or other such fully enclosed areas. During heavy use, the grill will produce a lot of smoke. Ensure there is adequate area for it to dissipate.

300 and 500 Series Grills: When using a rear wall, locate a 110/120

volt supply outlet on the bottom left hand side beneath the solid bottom support at a maximum distance of 2 feet. This connection is to be used for the ignition system and canopy lights. In addition, the rotisserie motor requires a separate 110/120 volt supply to be located on the right hand side of the grill. Both the power supply cords for the ignition/lights and the rotisserie motor are equipped with a 3-prong (grounded) plug for protection against shock hazard. Do not cut or remove the grounding from the plug. The electrical service must be equipped with a properly grounded 3- prong receptacle as required by the National Electrical Code ANSI/NFPA 70- latest edition. Installation in Canada must be in accordance with the Canadian Electrical Code, CSA 22.1 and local codes.

IMPORTANT: Gas fittings, regulator, and installer supplied shut-off valve must be easily accessible.

11

General Information Keep grill area clear and free from combustible

materials, gasoline, and other flammable vapors.

When the outdoor grill is not in use, the gas supply must be turned off at the LP gas supply cylinder.

The pressure regulator and hose assembly supplied with the outdoor grill must be used. Replacement pressure regulators and hose assemblies must be those specified by the manufacturer.

Finding a leak is not a do-it-yourself procedure. Some leaks can only be found with the burner control in the on position and this must be done by a qualified technician.

The LP supply cylinder to be used must be constructed and marked in accordance with the specifications for LP- gas cylinders of the U.S. Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA- B339, Cylinders, Spheres, and Tubes for the Transportation of Dangerous Goods.

Use only extension cords with a 3-prong grounding plug, rated for the power of the equipment, and approved for outdoor use with a W-A marking.

Gas Manifold Pressure Natural gas - 4.0 W.C.P. LP/Propane - 10.0 W.C.P.

10

WARNING This outdoor gas grill is not intended to be

installed inside a home or on recreational vehicles

and/or boats.

WARNING Keep electrical supply cord and the fuel supply

hose away from heated surfaces.

WARNING This appliance is not fused. Installer must install

a ground fault interrupt.

WARNING If the following instructions are not followed

exactly, a fire causing death or serious injury

may occur: Do not store a spare LP gas cylinder under

or near this appliance. Never fill the cylinder beyond 80 percent full.

WARNING This appliance is not fused. Installer must install

a ground fault interrupt.

22-15/16 (58.3 cm)

17-3/16(43.7 cm)

10-5/8(26.9 cm)

34-1/4(86.9 cm) 8(20.3 cm) 5-3/8(13.7 cm)

29

(73.6 cm)

27-13/16

(70.6 cm)

3 min.

(7.6 cm) to non-

combustable

surface

24 min.

(61.0 cm) to

combustable

surface

6(15.2 cm)

Clearance Dimensions (100 and 300 Series 36W. Grill)

13

22-15/16 (58.3 cm)

17-3/16(43.7 cm)

10-5/8(26.9 cm)

27-9/16(70.0 cm) 8(20.3 cm)

5-3/8(13.7 cm)

27-13/16

(70.6 cm)

29

(73.6 cm)

3 min.

(7.6 cm) to non-

combustable

surface

24 min.

(61.0 cm) to

combustable

surface

6(15.2 cm)

Clearance Dimensions (100 and 300 Series 30W. Grill)

12

VGBQ1302/VGBQ3302RE VGBQ1363/VGBQ3363RE

22-15/16 (58.3 cm)

16-5/8(80.2 cm)

10-1/4(26.0 cm)

41-3/16(104.6 cm) 8(20.3 cm) 5-3/8(13.7 cm)

32-3/4

(83.2 cm)

31-9/16

(80.2 cm)

3 min.

(7.6 cm) to non-

combustable

surface

24 min.

(61.0 cm) to

combustable

surface

6(15.2 cm)

VGBQ54203RE/VGIQ54203RE

1514

22-15/16 (58.3 cm)

16-5/8(80.2 cm)

10-1/4(26.0 cm)

29-1/2(74.9 cm) 8(20.3 cm)

5-3/8(13.7 cm)

32-3/4

(83.2 cm)

31-9/16

(80.2 cm)

3 min.

(7.6 cm) to non-

combustable

surface

24 min.

(61.0 cm) to

combustable

surface

6(15.2 cm)

Clearance Dimensions (500 Series 30W. Grill) Clearance Dimensions (500 Series 42W. Grill)

VGBQ53002RE

22-15/16 (58.3 cm)

16-5/8(80.2 cm)

10-1/4(26.0 cm)

6(15.2 cm)

50(127 cm) 8(20.3 cm)

5-3/8(13.7 cm)

32-3/4

(83.2 cm)

31-9/16

(80.2 cm)

3 min.

(7.6 cm) to non-

combustable

surface

24 min.

(61.0 cm) to

combustable

surface

VGBQ55404RE/VGIQ55404RE

10-1/8(25.7 cm)

36(91.4 cm)

**Access door opening

24-3/8

(61.9 cm) 28-5/8(72.7 cm) 3(7.6 cm) min. Electrical connection for rotisserie motor (position unit so that the plug is always accessible)

Electrical connection for power supply cord on 300 Series to be located on rear wall with a maximum distance of 2 (61.0 cm) beneath solid bottom support.

*Solid bottom

support

Countertop typically requires 3/4 wide by 3/4 deep notch cutout on each side of grill. This allows grill CP to sit back properly in the cutout.

Gas inlet and power cord location area

5(12.7 cm)

5 (12.7 cm)

3/4

(1.9 cm)

3/4 (1.9 cm)

17

Cutout Dimensions (100 and 300 Series 30W. Grill)

**Access Doors sold separately - refer to access door installation instructions for correct dimensions.

*IMPORTANT

Cabinet cutout must have a solid bottom

to support the full weight of the unit.

16

Clearance Dimensions (500 Series 54W. Grill)

10-1/4(26.0 cm)

36(91.4 cm)

**Access door opening

28

(71.1 cm) 28-5/8(72.7 cm) 3(7.6 cm) min.

Electrical connection for rotisserie motor (position unit so that the plug is always accessible)

Electrical connection for power supply cord on 500 Series to be located on rear wall with a maximum distance of 2 (61.0 cm) beneath solid bottom support.

*Solid bottom

support

Countertop typically requires 1/2 wide by 1/2 deep notch cutout on each side of grill. This allows grill CP to sit back properly in the cutout.

Gas inlet and power cord location area

5(12.7 cm)

5 (12.7 cm)

1/2

(1.2 cm)

1/2 (1.2 cm)

**Access Doors sold separately - refer to access door installation instructions for correct dimensions.

*IMPORTANT

Cabinet cutout must have a solid bottom

to support the full weight of the unit.

Cutout Dimensions (500 Series 30W. Grill)

19

10-1/8(25.7 cm)

36(91.4 cm)

**Access door opening

24-3/8

(61.9 cm) 35-1/4(89.5cm)

3(7.6 cm) min. Electrical connection for rotisserie motor (position unit so that the plug is always accessible)

Electrical connection for power supply cord on 300 Series to be located on rear wall with a maximum distance of 2 (61.0 cm) beneath solid bottom support.

*Solid bottom

support

Countertop typically requires 3/4 wide by 3/4 deep notch cutout on each side of grill. This allows grill CP to sit back properly in the cutout.

Gas inlet and power cord location area

5(12.7 cm)

5 (12.7 cm)

3/4

(1.9 cm)

3/4 (1.9 cm)

Cutout Dimensions (100 and 300 Series 36W. Grill)

18

**Access Doors sold separately - refer to access door installation instructions for correct dimensions.

*IMPORTANT

Cabinet cutout must have a solid bottom

to support the full weight of the unit.

10-1/4(26.0 cm)

36(91.4 cm)

**Access door opening

28

(71.1 cm) 52-1/4(132.7 cm)

3(7.6 cm) min.

Electrical connection for rotisserie motor (position unit so that the plug is always accessible)

Electrical connection for power supply cord on 500 Series to be located on rear wall with a maximum distance of 2 (61.0 cm) beneath solid bottom support.

*Solid bottom support

Gas inlet and power cord location area

5(12.7 cm)

5 (12.7 cm)

Countertop typically requires 1/2 wide by 1/2 deep notch cutout on each side of grill. This allows grill CP to sit back properly in the cutout.

1/2

(1.2 cm)

1/2 (1.2 cm)

Cutout Dimensions (500 Series 54W. Grill)

21

10-1/4(26.0 cm)

36(91.4 cm)

**Access door opening

28

(71.1 cm) 40-1/4(102.2 cm)

3(7.6 cm) min.

Electrical connection for rotisserie motor (position unit so that the plug is always accessible)

Electrical connection for power supply cord on 500 Series to be located on rear wall with a maximum distance of 2 (61.0 cm) beneath solid bottom support.

*Solid bottom support

Gas inlet and power cord location area

5(12.7 cm)

5 (12.7 cm)

Countertop typically requires 1/2 wide by 1/2 deep notch cutout on each side of grill. This allows grill CP to sit back properly in the cutout.

1/2

(1.2 cm)

1/2 (1.2 cm)

Cutout Dimensions (500 Series 42W. Grill)

20

**Access Doors sold separately - refer to access door installation instructions for correct dimensions.

*IMPORTANT

Cabinet cutout must have a solid bottom

to support the full weight of the unit.

**Access Doors sold separately - refer to access door installation instructions for correct dimensions.

*IMPORTANT

Cabinet cutout must have a solid bottom

to support the full weight of the unit.

Gas and Electrical Connection

Gas Connection Verify the type of gas supply to be used, either natural or LP, and make sure the marking on the grill rating plate agrees with that of the supply. Never connect an unregulated gas line to the appliance. An installer supplied gas shut-off valve must be installed in an easily accessible location. All installer supplied parts must conform to local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 and the National Fuel Code, ANSI Z223.1/NFPA 54.

In Canada: Installation must be in accordance with the current CSA-B149.1, Natural Gas Installation Code or CSA-B149.2, Propane Installation Code and/or local codes. All pipe sealants must be an approved type and resistant to the actions of LP gas. Never use pipe sealant on flare fittings. All gas connections should be made by a competent technician and in accordance with local codes and or ordinances. In the absence of codes, the installation must comply with the National Fuel Gas Code ANSI Z223.1/NFPA 54. The gas grill and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 PSIG (3.5 kPa). The gas grill must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of that system at test pressures equal to or less than 1/2 psi (3.5 kPa). Built-in installations must be plumbed using a fixed/hard line if the unit is going to be operated at a distance exceeding 3 feet (0.91 meters) from the fuel supply per ANSI Z21.24 CSA.

Gas Conversion To convert a grill from natural to LP/Propane or LP/Propane to natural, you MUST use conversion kit sold seperately.

Electrical Connection

2322

Vents

1.00 inch maximum

5.00 inch maximum

All vents no more than 5.00 inches above the floor of the installation.

5.00 inch maximum

Not more than 5.00 inches from inside bottom of countertop.

Bottom Vent not more than 1.00 inch from inside floor of installation.

Vents located on sidewall

Ventilation for Built-In Installations

An enclosure for an LP-gas cylinder shall be ventilated by openings at both the upper and lower levels of the enclosure. The effectiveness of the opening(s) for purposes of ventilation shall be determined with the LP-gas supply cylinder in place. This shall be accompanied by one of the following:

a. One side of the enclosure shall be completely open; or b. For an enclosure having four sides, a top and a bottom:

1. At least two ventilation openings (See Part IV, Definitions) shall be provided in the side walls of the enclosure, located within 5 in. (217 mm) of the top of the enclosure, equally sized, spaced at a minimum of 90 degrees (1.57 rad), and unobstructed. The opening(s) shall have a total free area of not less than 1 in2/lb (1.42 cm2/kg) of stored fuel capacity.

2. Ventilation opening(s) shall be provided at floor level at rear of the enclosure and shall have a total free area of not less than 1/2 in2/lb (7.1 cm2/kg) of stored fuel capacity. The bottom of the openings shall be 1 in. (25.4 mm) or less from the floor level and the upper edge no more than 5 in. (127 mm) above the floor level. The openings shall be equally sized, spaced at a minimum of 90 degrees (1.57 rad) and unobstructed.

3. Every opening shall have minimum dimensions so as to permit the entrance of a 1/8 inch (3.2 mm) diameter rod.

4. Ventilation openings in the side walls shall not communicate directly with other enclosures of the outdoor cooking gas appliance.

Note: It is strongly recommended to follow the same ventilation requirements when using Natural Gas.

CAUTION Conversions should only be performed by an

authorized service technician.

WARNING ELECTRICAL SHOCK HAZARD

This appliance is equipped with a 3

(91.4 cm) 3-prong power cord with a

grounding plug for your protection

against shock hazard and should be

plugged directly into a properly grounded

receptacle. Do not cut or remove the grounding

prong from this plug. This unit is not fused and

installer must install a GFI. Unit must be

grounded in accordance with local codes or with

the National Electrical Code ANSI/NFPA 70, or

the Canadian Electrical Code, CSA C22.1.

3/8 male flare dapteradapter

Installer supplied flexible gas line with 3/8 female adapter or GHS12

Installer supplied shut-off valve must be easily accessible

3/8 female flare adapter

Regulator Assembly

3/8 male flare adapter

LP/Propane Fixed Piping Connection Check with your local gas utility company or with local codes for instructions on installing gas supply lines. Be sure to check on type and size of run and how deep to bury the lines. If the gas line is too small, the grill will not function properly.

To connect the supplied regulator assembly to the incoming flexible gas line, attach with a 3/8 female flare adapter to the 3/8 male flare

adapter to the regulator assembly. Ensure that the regulator arrow points in the direction of the gas flow towards the unit and away from the supply. Attach the regulator assembly to the grill unit with the 3/8 female flare adapter on the regulator assembly to the 3/8 male flare adapter on the grill. Do not forget to place the installer supplied gas valve in an accessible location

25

Male coupler

Installer supplied flexible gas line with 1/2 female adapter or GHS12

Installer supplied shut-off valve must be easily accessible

female coupler

7/8 male flare adapter

Regulator Assembly

Natural Fixed Piping Connection Check with your local gas utility company or with local codes for instructions on installing gas supply lines. Be sure to check on type and size of run and how deep to bury the lines. If the gas line is too small, the grill will not function properly.

To connect the supplied regulator assembly to the incoming flexible gas line, attach with a 7/8 (2.2 cm) female flare adapter to the 7/8 (2.2 cm) male flare adapter on the regulator assembly. Ensure that the regulator arrow points in the direction of the gas flow towards the unit and away from the supply. Attach the regulator

assembly to the grill unit by pulling back the female coupler sleeve towards the regulator. Insert the coupler into the male coupler fitting on the grill until the sleeve snaps forward securing the connection. Do not forget to place the installer supplied gas valve in an accessible location.

Note: If using a Viking GSH12 flexible hose, remove the 1/2 flare adapter and attach hose to the 7/8 (2.2 cm) male flare on the regulator assembly.

24

Connection Operating Pressure Supply Pressure Standard Residential 1/2" ID gas service line - 1/2" NPT male with

7/8" (2.2 cm) flare adapter.

4.0" W.C.P. Nat. 6" to 10" W.C.P. Nat. If in excess of 10" W.C.P., a step-down

regulator is required.

Connection Operating Pressure Supply Pressure Standard Residential 1/2" ID gas service line - 1/2 NPT male with

3/8" flare adapter.

10.0" W.C.P. LP/Propane 11" to 14" W.C.P. LP. If in excess of 14" W.C.P., a step-down

regulator is required.

3/8 male flare adapter

Type 1, QCC-1 connector

3/8 female flare adapter

3/8 male flare adapter

Regulator Assembly

NOTE: Tank must be mounted in vertical position for proper Ventilation

LP/Propane Tank Connection Outdoor grills orificed for use with LP/Propane gas come equipped with a high capacity hose/regulator assembly for connection to a standard 20 lb. LP/Propane cylinder equipped with a Type 1, QCC-1 connector. Hose assembly must comply with Elastomeric Composite Hose and Couplings for conducting Propane and Natural Gas, CAN/CGA-8.1 standard or the Theromplastic Hose and Hose Couplings for conducting Propane and Natural Gas

CAN1-8.3 standard. (See LP/Propane tank requirements below). Each tank is supplied with a dust cap. Place dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap on the cylinder valve outlet that is provided with the cylinder valve. Other types of caps or plugs may result in leakage of propane.

Connect the regulator to the grill unit by screwing the 3/8 flare coupling to the 3/8 flare adapter. Connect to the tank valve by screwing the Type 1, QCC-connector to the LP/Propane tank. Open the tank valve and check the

connection between the regulator and the Type 1, QCC-1 fitting for leaks with a soapy water solution. If bubbles appear, tighten the connection. Repeat until all leaks have been stopped. ALWAYS CHECK FOR LEAKS AFTER EVERY LP/PROPANE TANK CHANGE. Any joint sealant used must be an approved type and be resistive to the actions of LP/Propane gas.

27

LP/Propane Tank Requirements A dented or rusty LP/Propane tank may be hazardous and should be checked by your tank supplier. Never use a cylinder with a damaged valve. All tanks should be equipped with an OPD (overfilling protection device). This is a DOT requirement for all tanks purchased after October 1, 1998 and will ensure that the tank is not overfilled. The LP/Propane tank should be a standard 5-gal, 20 lb. gas cylinder tank approximately 12 in diameter and 18 high which must be constructed and marked in accordance with the Specifications for LP/Propane Gas Cylinders of the U.S. Department of Transportation (D.O.T.) or the National Standard of Canada, CAN/CSA-B339, Cylinders, Spheres and Tubes for Transportation of Dangerous Goods; and Commission. The cylinder connection device must be compatible with the Type 1, QCC-1 connector on the outdoor cooking appliance.

All LP/Propane tanks must be mounted in a vertical position for proper ventilation. The cylinder must be provided with a shut-off valve terminating in an LP/Propane gas supply cylinder valve outlet specified. The cylinder supply system must be arranged for vapor withdrawal and provided with a listed overfilling prevention device. If the appliance is stored indoors the cylinder must be disconnected and removed from the appliance. Each tank is supplied with a dust cap. Place dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap on the cylinder valve outlet that is provided with the cylinder valve.

Other types of caps or plugs may result in leakage of propane. The cylinder used must include a collar to protect the cylinder valve. Cylinders must be stored outdoors in a well- vented area out of the reach of children.

Built-In Installations Built-in installations must be plumbed using a fixed/hard line if the unit is going to be operated at a distance exceeding 3 feet (0.91 meters) from the fuel supply per ANSI Z21.24 CSA. Also, in a built-in construction where an LP/Propane tank is going to be used, there MUST be some type of support (braces, cutout, etc.) to prevent tank from moving within the installation. The support must also allow the LP/Propane tank to withstand a horizontal tipping force equal to the weight of the tank without tipping over. The tank can not tip over or deflect more than 1.00 inch when a 8 lb. horizontal force is applied to a 20 lb. LP/Propane tank

26

Connection Operating Pressure 1/2 (1.3 cm) NPT male with a 3/8 (.95) flare adapter 10.0 W.C.P. LP/Propane.

29

5 6

Bubbling bubbles in the soap solution indicates that a leak is present.

Stop a leak by tightening the loose joint or by replacing the faulty part with a replacement part

recommended by the manufacturer.

7

2

8 1

Do not attempt to repair the cylinder valve if it should become damaged. The cylinder must be replaced.

If you are unable to stop a leak, shut off the gas at the cylinder valve. Remove the cylinder from the grill.

Call an authorized gas appliance service technician or LP/Propane gas dealer.

Do not use the grill until

the leak is corrected.

1

2

9

After checking for leaks, push in and turn any control knob to release the pressure in the hose and manifold.

Turn off the control knob.

28

1

2

Make a soap solution of one part liquid detergent and one part water. You will need a spray bottle, brush or

towel to apply the solution to the fittings. Note: For LP/Propane units, check with a full cylinder.

Check that all control knobs are in the OFF position.

4

Apply the soap solution to fittings. Turn cylinder valve knob counter clockwise one turn to open.

Although all gas connections on the grill are leak tested at the factory prior to shipment, a complete gas tightness check must be performed at the installation due to possible mishandling in shipment or excessive pressure unknowingly being applied to the unit. Periodically check the whole system for leaks, or immediately check if the smell of gas is detected.

Do not smoke while leak testing. Extinguish all flames. Never leak test with an open flame

CAUTION Before placing into operation, always check for

gas leaks with a soapy water solution. DO NOT

USE AN OPEN FLAME TO CHECK FOR LEAKS.

Leak Testing

3

31

1/2"(1.3 cm)3/8"(.95 cm)

CORRECT

YELLOW

BLUE LIFTING

5

1

Off

6

2

3

If the flame is yellow, turn the air shutter counter clockwise to allow more air to the burner. If the

flame is noisy and lifting away from the burner, turn the air shutter clockwise to reduce the amount

of air to the burner.

Once adjusted, turn the burner off, tighten the set screw on the air shutter. For grill burners, replace the

valve panel and knobs.

7

Replace the drip tray

30

1 2

To access the air shutter on the grill burners, remove the drip tray.

Remove the knobs and valve panel. Note: Leave wires connected to switches on valve panel.

3

2

1

HI/LITE

4

With a screw driver, loosen the lock-screw on the face of the air shutter.

Push and turn the the valve to light the burner and adjust according to the directions following. Must push ignition

button on 100 Series. Note: By replacing the knob, it may be easier to light the burner.

A qualified installer should perform the following burner adjustments. Each burner is tested and adjusted at the factory prior to shipment; however, variations in the local gas supply may make it necessary to adjust the burners. The flames of the burners (except the rotisserie infrared burner) should be visually checked and compared with the following illustrations.

Flames should be blue and stable with no yellow tips, excessive noise or lifting. If any of these conditions exist, check if the air shutter or burner ports are blocked by dirt, debris, spider webs, etc. With a proper flame height, adjust the air shutter to obtain a blue flame with no yellow tipping that sits on the burner at the burner ports. The air shutter is locked in place by a set screw which must be loosened prior to lighting the burner for adjustments.

Burner Adjustment

CORRECT YELLOW BLUE LIFTING

Performance Checklist A qualified installer should carry out the following checks: All internal packaging removed. Specified clearances maintained to

combustible materials. Pressure regulator connected and set. Manual shut-off valve installed and accessible. Check air shutter adjustment - sharp blue

flame, no yellow tipping. Check for gas leaks (odors) at all gas

connections. Each burner lights satisfactorily, individually or

with adjacent burners lit.

Any adjustments necessary that are the result of the installer not following instructions will be responsibility of the installer, dealer or the end user of the product.

33

Rotisserie System The rotisserie motor is attached to the mounting bracket located on the right side of the grill frame. The rotisserie motor must be electrically grounded in accordance with local codes. The skewer for the rotisserie is assembled into the gear box assembly by placing the pointed end into the gear box, and resting the threaded end on the support at the left side of the grill. With the skewer pushed as far in as possible, the grooved skewer bushing should rest on the left side bracket. Do not remove the plastic cover on the rotisserie motor switch due to safety consideration.

32

WARNING ELECTRICAL SHOCK HAZARD

This appliance is equipped with a grounding

plug for your protection against shock hazard

and should be plugged directly into a properly

grounded receptacle. Do not cut or remove the

grounding prong from this plug.

Groove skewer support

Grounded plug

Skewer

Gear box

Mounting bracket

Final Preparation Some stainless steel parts may have a plastic

protective wrap which must be peeled off. The interior should be washed thoroughly with hot, soapy water to remove film residues and any dust or debris before being used, then rinsed and wiped dry. Solutions stronger than soap and water are rarely needed.

All stainless steel body parts should be wiped with hot, soapy water and with a liquid cleaner designed for this material. If buildup occurs, do not use steel wool, abrasive cloths, cleansers, or powders!

If it is necessary to scrape stainless steel to remove encrusted materials, soak with hot, wet cloths to loosen the material, then use a wool or nylon scraper. Do not use a metal knife, spatula, or any other material tool to scrape stainless steel! Scratches are almost impossible to remove..

3534

Service & Registration Only authorized replacement parts may be used in performing service on the appliance. All servicing should be referred to a qualified technician.

Contact Viking Range, LLC, 1-888-(845-4641), for the nearest service parts distributor in your area or write to:

VIKING RANGE, LLC PREFERRED SERVICE

111 Front Street Greenwood, Mississippi 38930 USA

Record the following information indicated below. You will need it if service is ever required.

The serial number and model number for your grill are located underneath the pullout drip tray on the left hand side.

Model number ____________________________________________________________________________________

Serial number _____________________________________________________________________________________

Date of purchase __________________________________________________________________________________

Date installed ______________________________________________________________________________________

Manualsnet FAQs

If you want to find out how the VGBQ13603 Viking works, you can view and download the Viking VGBQ13603 Grill Installation Guide on the Manualsnet website.

Yes, we have the Installation Guide for Viking VGBQ13603 as well as other Viking manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Installation Guide should include all the details that are needed to use a Viking VGBQ13603. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Viking VGBQ13603 Grill Installation Guide is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Viking VGBQ13603 Grill Installation Guide consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Viking VGBQ13603 Grill Installation Guide free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Viking VGBQ13603 Grill Installation Guide, simply download the document to your computer. Once downloaded, open the PDF file and print the Viking VGBQ13603 Grill Installation Guide as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.