Summary of Content for Subaru R1700i Generator User Instructions PDF

3ZZ9990170

4

3

1

2

2

4

5

6

7

8

9

10

1

5

4

1

2

3

4

3

7

6

1

2

3

1

1

2

3

3

1

1

2

2

3

4

1

2

6

1

2

3

4

12

11

10

6

7

8

9

1 2

1

2

PILOT LAMP

OVER LOAD

5

2

1

1 2

1

1

1 2

" "

" "

ON

STOP RUN

CHOKE

OFF

STOP RUN

CHOKE

STOP RUN

CHOKE

3 4

STOP RUN

CHOKE

E N

G L

IS H

F R

A N

A

IS E

E S

P A

O

L

NOTICE FEDERAL EMISSION COMPONENT DEFECT WARRANTY and CALIFORNIA EMISSION CONTROL WARRANTY are applicable to only those engines/ generators complied with EPA (Environmental Protection Agency) and CARB (California Air Resources Board) emission regulations in the U.S.A.

AIR INDEX To show compliance with California emission regulations, a hangtag has been provided displaying the Air Index level and durability period of this engine.

The Air Index level defines how clean an engines exhaust is over a period of time. A bar graph scaled from 0 (most clean) to 10 (least clean) is used to show an engines Air Index level. A lower Air Index level represents cleaner exhaust from an engine.

The period of time (in hours) that the Air Index level is measured is known as the durability period. Depending on the size of the engine, a selection of time periods can be used to measure the Air Index level (see below).

Descriptive Term Applicable to Emissions Durability Period

Moderate - 50 hours (engine from 0 to 80 cc) 125 hours (engine greater than 80 cc)

Intermediate - 125 hours (engine from 0 to 80 cc) 250 hours (engine greater than 80 cc)

Extended - 300 hours (engine from 0 to 80 cc) 500 hours (engine greater than 80 cc)

Notice : This hangtag must remain on this engine or piece of equipment, and only be removed by the ultimate purchaser before operation.

The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

WARNING:

NOTICE To the engines/generators exported to and used in the countries other than the U.S.A., warranty service shall be performed by the distributor in each country in accordance with the standard Robin engine/generator warranty policy as applicable.

R1700I(US)_GU2093 05.3.8 1:46 PM 01

E N

G L

IS H

F R

A N

A

IS E

E S

P A

O

L

FEDERAL EMISSIONS COMPONENT DEFECT WARRANTY

EMISSIONS COMPONENT DEFECT WARRANTY COVERAGE This emission warranty is applicable in all States, except the state of California.

Fuji Heavy Industries Ltd. and Robin America Inc., Wood Dale Illinois, (herein ROBIN AMERICA) warrant(s) to the initial retail purchaser and each subsequent owner, that this Nonroad engine (herein engine) has been designed, built, and equipped to conform at the time of initial sale to all applicable regulations of the U.S. Environmental Protection Agency (EPA), and that the engine is free of defects in materials and workmanship which would cause this engine to fail to conform with EPA regulations during its warranty period.

For the components listed under PARTS COVERED, the service dealer authorized by ROBIN AMERICA will, at no cost to you, make the necessary diagnosis, repair, or replacement necessary to ensure that the engine complies with applicable U.S. EPA regulations.

EMISSISON COMPONENT DEFECT WARRANTY PERIOD

The warranty period for this engine begins on the date of sale to the initial purchaser and continues for a period of two years.

PARTS COVERED

Listed below are the parts covered by the Emission Components Defect Warranty. Some of the parts listed below may require scheduled maintenance and are warranted up to the first scheduled replacement point for that part.

(1) Fuel Metering System

(i) Carburetor and internal parts (and/or pressure regulator or fuel injection system).

(ii) Air/fuel ratio feedback and control system, if applicable.

(iii) Cold start enrichment system, if applicable.

(iv) Regulator assy (gaseous fuel, if applicable)

(2) Air Induction System

(i) Intake manifold, if applicable

(ii) Air filter.

(3) Ignition System

(i) Spark plugs.

(ii) Magneto or electronic ignition system.

(iii) Spark advance/retard system, if applicable.

(4) Exhaust manifold, if applicable

(5) Miscellaneous Items Used in Above Systems

(i) Electronic controls, if applicable

(ii) Hoses, belts, connectors, and assemblies.

(iii) Filter lock assy (gaseous fuel, if applicable)

OBTAINING WARRANTY SERVICE

To obtain warranty service, take your engine to the nearest authorized Robin America service dealer . Bring your sales receipts indicating date of purchase for this engine. The service dealer authorized by ROBIN AMERICA will perform the necessary repairs or adjustments within a reasonable amount of time and furnish you with a copy of the repair order. All parts and accessories replaced under this warranty become the property of ROBIN AMERICA.

WHAT IS NOT COVERED

*Conditions resulting from tampering, misuse, improper adjustment (unless they were made by the service dealer authorized by ROBIN AMERICA during a warranty repair), alteration, accident, failure to use the recommended fuel and oil, or not performing required maintenance services.

*The replacement parts used for required maintenance services.

*Consequential damages such as loss of time, inconvenience, loss of use of the engine or equipment, etc.

*Diagnosis and inspection charges that do not result in warranty- eligible service being performed.

*Any non-authorized replacement part, or malfunction of authorized parts due to use of non-authorized parts.

OWNERS WARRANTY RESPONSIBILITIES

As the engine owner, you are responsible for the performance of the required maintenance listed in your owners manual. ROBIN AMERICA recommends that you retain all receipts covering maintenance on your engine, but ROBIN AMERICA cannot deny warranty solely for the lack of receipts or for your failure to ensure the performance of all scheduled maintenance.

As the engine owner, you should however be aware that ROBIN AMERICA may deny warranty coverage if your engine or a part has failed due to abuse, neglect, improper maintenance or unapproved modifications.

You are responsible for presenting your engine to the nearest service dealer authorized by ROBIN AMERICA when a problem exists.

If you have any questions regarding your warranty rights and responsibilities, you should contact the Robin America customer service department at 1-630-350-8200 for the information.

THINGS YOU SHOULD KNOW ABOUT THE EMISSION CONTROL SYSTEM WARRANTY MAINTENANCE AND REPAIRS

You are responsible for the proper maintenance of the engine. You should keep all receipts and maintenance records covering the performance of regular maintenance in the event questions arise. These receipts and maintenance records should be transferred to each subsequent owner of the engine. ROBIN AMERICA reserves the right to deny warranty coverage if the engine has not been properly maintained. Warranty claims will not be denied, however, solely because of the lack of required maintenance or failure to keep maintenance records.

MAINTENANCE, REPLACEMENT OR REPAIR OF EMISSION CONTROL DEVICES AND SYSTEMS MAY BE PERFORMED BY ANY REPAIR ESTABLISHMENT OR INDIVIDUAL; HOWEVER, WARRANTY REPAIRS MUST BE PERFORMED BY A SERVICE DEALER AUTHORIZED BY ROBIN AMERICA. THE USE OF PARTS THAT ARE NOT EQUIVALENT IN PERFORMANCE AND DURABILITY TO AUTHORIZED PARTS MAY IMPAIR THE EFFECTIVENESS OF THE EMISSION CONTROL SYSTEM AND MAY HAVE A BEARING ON THE OUTCOME OF A WARRANTY CLAIM.

If other than the parts authorized by ROBIN AMERICA are used for maintenance replacements or for the repair of components affecting emission control, you should assure yourself that such parts are warranted by their manufacturer to be equivalent to the parts authorized by ROBIN AMERICA in their performance and durability.

HOW TO MAKE A CLAIM

All repair qualifying under this limited warranty must be performed by a service dealer authorized by ROBIN AMERICA. In the event that any emission-related part is found to be defective during the warranty period, you shall notify Robin America customer service department at 1-630- 350-8200 and you will be advised of the appropriate warranty service dealer or service providers where the warranty repair can be performed.

R1700I(US)_GU2093 05.3.8 1:46 PM 02

E N

G L

IS H

F R

A N

A

IS E

E S

P A

O

L

CALIFORNIA EMISSION CONTROL WARRANTY STATEMENT YOUR WARRANTY RIGHTS AND OBLIGATIONS

The California Air Resources Board and Fuji Heavy Industries Ltd. (herein FUJI) are pleased to explain the emission control system warranty on your 2005 and later Small Off-Road engine (herein "engine"). In California, new engine must be designed, built and equipped to meet the State's stringent anti-smog standards. FUJI must warrant the emission control system on your engine for the periods of time described below, provided there has been no abuse, neglect or improper maintenance of your engine. Your emission control system may include parts such as the carburetor or fuel-injection system, and the ignition system. Also included may be hoses, belts, connectors and other emission-related assemblies. Where a warrantable condition exists, FUJI will repair your engine at no cost to you including diagnosis, parts and labor.

MANUFACTURER'S WARRANTY COVERAGE:

The 2005 and later engines are warranted for two (2) years. If any emission related part on your engine is defective, the part will be repaired or replaced by FUJI.

OWNER'S WARRANTY RESPONSIBILITIES :

-As the engine owner, you are responsible for the performance of the required maintenance listed in your Owner's Manual. FUJI recommends that you retain all receipts covering maintenance on your engine, but FUJI cannot deny warranty solely for the lack of receipts or for your failure to ensure the performance of all scheduled maintenance.

-As the engine owner, you should ,however, be aware that FUJI may deny you warranty coverage if your engine or a part has failed due to abuse, neglect, improper maintenance or unapproved modifications.

-You are responsible for presenting your engine to a service dealer or warranty station authorized by ROBIN AMERICA Inc. 940 Lively Blvd., Wood Dale, IL 60191 (herein ROBIN AMERICA) as soon as a problem exists. The warranty repairs should be completed in a reasonable amount of time, not to exceed 30 days.

If you have any questions regarding your warranty rights and responsibilities, you should contact the Robin America Inc. Customer Service Department at 1-630-350-8200

LIMITED WARRANTY on Emission Control Systems

- California Only -

FUJI warrants to the owner of the 2005 and later engine that the engine 1)has been designed, built and equipped so as to conform at the time of manufacture with the applicable regulations of the California Air Resources Board, and (2) is free from defects in materials and workmanship that could cause it to fail to conform with those regulations as may be applicablein the terms and conditions stated below.

A. COMMENCEMENT DATE

The warranty period begins on the date the engine is delivered to a first retail purchaser.

B. LENGTH OF COVERAGE

FUJI warrants to a first retail purchaser and each subsequent purchaser that the engine is free from defects in materials and workmanship that cause the failure of a warranted emission-related part for a period of two (2) years after the date of delivery to the first retail purchaser.

C. WHAT IS COVERED:

1. REPAIR OR REPLACEMENT PARTS Repairs and replacement of any warranted part will be performed at no charge to you by an authorized service dealer or a warranty station. You may contact the Robin America Inc. Customer Service Department at 1-630-350-8200 to obtain the name of the nearest appropriate location where your warranty repairs are performed.

2. WARRANTY PERIOD This warranty continues for a period of two (2) years and applies only to the repair, replacement or adjustment of the component parts that are not scheduled for replacement as required maintenance. Further, component parts which are scheduled only for regular inspection to the effect of "repair or replace as necessary" are warranted for the warranty period. Any warranted part which is scheduled for replacement as required maintenance is warranted for the period of time up to the first scheduled replacement point for that part.

3. DIAGNOSIS You will not be charged for diagnostic labor that leads to the determination that a warranted part is defective, if the diagnostic work is performed at an authorized service dealer or warranty station.

4. DAMAGES If a warranted part failed causing damage to other engine components, consult an warranty station.

D. WHAT IS NOT COVERED

1. This limited warranty does not cover any part which malfunctions, fails or is damaged due to failure to follow the maintenance and operating instructions set forth in the 2005 and later Owner's Manual including:

(1) improper maintenance of any warranted parts

(2) improper installation, adjustment or repair of the engine or of any warranted part unless performed by an authorized service dealer

(3) failure to follow recommendations on fuel use contained in the 2005 and later Owner's Manual

(4) repairs performed outside of the authorized warranty service dealers

(5) use of parts which are not authorized by FUJI.

2. Add-on or modified parts This warranty does not cover any part that malfunctions, fails or is damaged due to alterations by changing, adding to or removing parts from the engine.

3. Expenses incurred by processing warranty claims FUJI, any authorized service dealer and warranty station shall not be liable for any loss of use of the engine, for any alternative usage, for any damage to goods, loss of time or inconvenience.

E. HOW TO FILE A CLAIM

All repairs qualifying under this Limited Warranty must be performed by a dealer who sold you the engine or warranty station authorized by ROBIN AMERICA. In the event that any emission-related part is found to be defective during the warranty period, you must notify the Robin America Inc. Customer Service Department at 1-630-350-8200 and you will be advised of the appropriate warranty service facilities where the warranty repair is to be performed.

F. WHERE TO OBTAIN WARRANTY SERVICE

It is recommended that warranty service be performed by the authorized dealer who sold you the engine, although warranty service will be performed by any authorized service dealers or warranty stations anywhere in the United States.

R1700I(US)_GU2093 05.3.8 1:46 PM 03

E N

G L

IS H

F R

A N

A

IS E

E S

P A

O

L

When warranty repair is needed, the engine must be brought to an authorized service dealer or warranty stations place of business during normal business hours. In all cases, a reasonable time, not to exceed 30 days, must be allowed for the warranty repair to be completed after the engine is received by the authorized service dealer or warranty station.

G. MAINTENANCE, REPLACEMENT AND REPAIR OF EMISSION-RELATED PARTS

Only warranted engine replacement parts approved by FUJI should be used in the performance of any warranty maintenance or repairs on emission-related parts. If other than authorized parts are used for maintenance, replacement or repair of components affecting emission control, you should assure yourself that such parts are warranted by their manufacturer to be equivalent to authorized parts in performance and durability. FUJI ,however, assumes no liability under this warranty with respect to parts other than authorized parts. The use of non- authorized replacement parts does not invalidate the warranty on other components unless the non-authorized parts cause damage to warranted parts.

H. PARTS COVERED UNDER THE CALIFORNIA EMISSIONS WARRANTY

(1) Fuel Metering System

(i) Carburetor and internal parts (and/or pressure regulator or fuel injection system).

(ii) Air/fuel ratio feedback and control system, if applicable.

(iii) Cold start enrichment system, if applicable.

(iv) Regulator assy (gaseous fuel, if applicable)

(2) Air Induction System

(i) Intake manifold, if applicable

(ii) Air filter.

(3) Ignition System

(i) Spark plugs.

(ii) Magneto or electronic ignition system.

(iii) Spark advance/retard system, if applicable.

(4) Exhaust manifold, if applicable

(5) Miscellaneous Items Used in Above Systems

(i) Electronic controls, if applicable

(ii) Hoses, belts, connectors, and assemblies.

(iii) Filter lock assy (gaseous fuel, if applicable)

I. MAINTENANCE STATEMENTS

It is your responsibility to have all scheduled inspection and maintenance services performed at the times recommended in the 2005 and later Owner's Manual and to retain proof that inspection and maintenance services are performed at the times when recommended. FUJI will not deny a warranty claim solely because you have no record of maintenance; however, FUJI may deny a warranty claim if your failure to perform required maintenance resulted in the failure of warranted part. The proof which you maintain should be given to each subsequent owner of the engine. You are responsible for performing the scheduled maintenance described below based on the procedures specified in the 2005 and later Owner's Manual. The scheduled maintenance below is based on a normal engine operating schedule.

PROCEDURE INTERVAL

1) Change engine oil : Initial 20 hours and every 100 hours afterward 2) Clean air cleaner (element) : Every 50 hours 3) Replace air cleaner element : Every 200 hours 4) Clean and adjust spark plug and electrodes : Every 200 hours

Note: More frequent maintenance may be necessary under dusty, dirty or severe conditions.

R1700I(US)_GU2093 05.3.8 1:46 PM 04

1

E N

G L

IS H

F R

A N

A

IS E

E S

P A

O

L

FOREWORD Thank you very much for purchasing a ROBIN GENERATOR. This manual covers operation and maintenance of the ROBIN GENERATOR. This ROBIN GENERATOR can be used for general electrical equipments, appliances, lamps, tools as an AC power source. With regards to DC application, the terminals are used only for charging 12 volt battery. Never use this generator for any other purposes.

Please take a moment to familiarize yourself with the proper operation and maintenance procedures in order to maximize the safe and efficient use of this product. Keep this owners manual at hand, so that you can refer to it at any time. Due to constant efforts to improve our products, certain procedures and specifications are subject to change without notice.

When ordering spare parts, always give us the MODEL, PRODUCTION NUMBER (PROD No.) and SERIAL NUMBER (SER No.) of your Product.

Please fill in the following blanks after checking the production number on your product. (Location of label is different depending on the product model.)

CONTENTS 1. SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2. COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 3. CONTROLS AND INDICATORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 4. PRE-OPERATION CHECKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 5. OPERATING PROCEDURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 6. WATTAGE INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 7. SPARK ARRESTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 8. MAINTENANCE SCHEDULE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 9. "HOW-TO" MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

10. PERIODIC OPERATION AND INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 11. TRANSPORTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 12. PREPARATION FOR STORAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 13. TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 14. SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 15. WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

PROD No. SER No. (Label)

Please refer to the illustrations on the back page of the front cover or back cover for Fig. 1 to 6 indicated in the sentence.

NOTE

R1700I(US)_GU2093 05.3.8 1:46 PM 1

1. SAFETY PRECAUTIONS

2

E N

G L

IS H

F R

A N

A

IS E

E S

P A

O

L

Please make sure you review each precaution carefully.

Pay special attention to statement preceded by the following words.

WARNING indicates a strong possibility of severe personal injury or loss of life if instructions are not followed.

CAUTION indicates a possibility of personal injury or equipment damage if instructions are not followed.

Do not operate the generator near gasoline or gaseous fuel because of the potential danger of explosion or fire. Do not fill the fuel tank with fuel while the engine is running. Do not smoke or use open flame near the fuel tank. Be careful not to spill fuel during refueling. If fuel is spilt, wipe it off and let dry before starting the engine.

WARNING

WARNING

Operate the generator on a level surface. It is not necessary to prepare a special foundation for the generator. However, the generator will vibrate on an irregular surface, so choose a level place without surface irregularities. If the generator is tilted or moved during operation, fuel may spill and / or the generator may tip over, causing a hazardous situation. Proper lubrication cannot be expected if the generator is operated on a steep incline or slope. In such a case, piston seizure may occur even if the oil is above the upper level.

WARNING

Pay attention to the wiring or extension cords from the generator to the connected device. If the wire is under the generator or in contact with a vibrating part, it may break and possibly cause a fire, generator burnout, or electric shock hazard. Replace damaged or worn cords immediately.

WARNING

Do not operate the generator inside a room, cave, tunnel, or other insufficiently ventilated area. Always operate it in a well-ventilated area, otherwise the engine may become overheated, and the poisonous carbon monoxide gas contained in the exhaust gases will endanger human lives. Keep the generator at least 1 meter (3 feet) away from any structure or building during use.

If the generator must be used indoors, the area must be well-ventilated and extreme caution must be taken regarding the discharge of exhaust gases.

WARNING

Do not place in flammables near the generator. Be careful not to place fuel, matches, gunpowder, oily cloths, straw, trash, or any other in flammables near the generator.

WARNING

Do not enclose the generator nor cover it with a box. The generator has a built-in forced air cooling system, and may become overheated if it is enclosed. If generator has been covered to protect it from the weather during non use, be sure to remove it and keep it well away from the area during generator use.

WARNING

CAUTION

1m

1m

R1700I(US)_GU2093 05.3.8 1:46 PM 2

3

E N

G L

IS H

F R

A N

A

IS E

E S

P A

O

L

Do not contact the generator to a commercial power line. Connection to a commercial power line may short circuit the generator and ruin it or cause electric shock hazard. Use the transfer switch for connecting to domestic circuit.

WARNING

Engine becomes extremely hot during and for some time after operation. Keep combustible materials well away from generator area. Be very careful not to touch any parts of the hot engine especially the muffler area or serious burns may result.

WARNING

No smoking while handling the battery. The battery emits flammable hydrogen gas, which can explode if exposed to electric arcing or open flame. Keep the area well-ventilated and keep open flames/sparks away when handling the battery.

WARNING

Do not operate in rain, in wet or damp conditions, or with wet hands. The operator may suffer severe electric shock if the generator is wet due to rain or snow.

WARNING

Keep children and all bystanders at a safe distance from work areas.

WARNING

If wet, wipe and dry it well before starting. Do not pour water directly over the generator, nor wash it with water.

WARNING

Be extremely careful that all necessary electrical grounding procedures are followed during each and every use. Failure to do so can be fatal.

WARNING

It is absolutely essential that you know the safe and proper use of the power tool or appliance that you intend to use. All operators must read, understand and follow the tool/appliance owners manual. Tool and appliance applications and limitations must be understood. Follow all directions given on labels and warnings. Keep all instruction manuals and literature in a safe place for future reference.

WARNING

Use only "LISTED" extension cords. When a tool or appliance is used outdoors, use only extension cords marked "For Outdoor Use". Extension cords, when not in use should be stored in a dry and well ventilated area.

WARNING

Always switch off and disconnect tools or appliances when not in use, before servicing, adjusting, or installing accessories and attachments.

WARNING

Make sure the engine is stopped before starting any maintenance, servicing or repair.

CAUTION

NOTE : Make sure maintenance and repair of the generator set are performed by properly trained personnel only.

R1700I(US)_GU2093 05.3.8 1:46 PM 3

4

E N

G L

IS H

F R

A N

A

IS E

E S

P A

O

L

Symbols and Meanings In accordance with the European requirements (eec Directives),the specified symbols as shown in the following table are used for the products and this instruction manual.

Read the operator's instruction manual.

Stay clear of the hot surface.

Exhaust gas is poisonous. Do not operate in an unventilated room.

Stop the engine before refueling.

Fire, open light and smoking prohibited.

Caution, risk of electric shock.

HOT, avoid touching the hot area.

Do not connect the generator to the commercial power lines.

Engine oil

ON (power and Engine)

Add oil

Battery charging condition

OFF (power and Engine)

Alternating current

Direct current

Plus ; positive polarity

Minus ; negative polarity

OUT-position of a bistable push control

IN-position of a bistable push control

Protective earth (ground)

Fuse

Choke ; cold starting aid

Engine start (Electric start)

Engine stop

Gasoline

Fast

Slow

Fuel start

Fuel stop

P r Rated power (kW) COP Continuous power COS r Rated power factor

f r Rated frequency (Hz) U r Rated voltage (V) I r Rated current (A)

H max Maximum site altitude above sea-level (m) T max

Maximum ambient temperature ( ) m Mass (kg)

R1700I(US)_GU2093 05.3.8 1:46 PM 4

2. COMPONENTS (See Fig. 1)

3. CONTROLS AND INDICATORS (See Fig. 2) 1. ENGINE SWITCH (See Fig. 2-q)

Please refer to the illustrations on the back page of the front cover or back cover for Fig. 1 to 6 indicated in the sentence.

NOTE

q RECOIL STARTER (HANDLE)

w CONTROL PANEL

e SIDE PANEL (L)

r AIR CLEANER

t FUEL DRAIN SCREW

y CARRYING HANDLE

u TANK CAP COVER

i EXHAUST OUTLET

o OIL DRAIN PLUG

!0 SIDE PANEL (R)

!1 OIL GAUGE (OIL FILLER)

!2 SPARK PLUG CAP

The engine switch is designed for easy operation with the interlocking mechanism between the fuel cock and the choke furnished.

The AUTO POWER SAVE LAMP is turned on when the switch is in the ON position. With the switch in the marking position, the engine speed is reduced automatically when no electricity is taken out, while the engine speed is automatically adjusted in accordance with the load condition when the electricity is taken out. When using in the heavy load condition, set the switch into the marking position to maintain the electric power level in the stable condition. When using DC power, turn the switch into the OFF position.

5

E N

G L

IS H

F R

A N

A

IS E

E S

P A

O

L5. AC RECEPTACLES AC electric power is available through this receptacle. Use a ground type, three-leg plug as shown.

CHOKE To start the engine, turn the knob to the position. (Choke valve is closed.)

RUN Keep the knob in this position after the engine starts. (The engine can be started with the knob at this position when the engine is warm.)

STOP To stop the engine, return the knob to the position. (The fuel cock is closed as well.)

Do not plug more than two appliances into the generator at a time.

Do not put foreign objects into the plug receptacle.

CAUTION

2. PILOT LAMP and OVERLOAD LAMP (See Fig. 2-w)

These lamps are turned on in the following conditions; PILOT LAMP (Green) --- The lamp is turned on

while generating properly. OVERLOAD LAMP (Red) --- The lamp is turned on in the

overload condition. * The breaker will be activated after the lamp is

turned on for 20 seconds in the 120% electric power condition, and results in no load condition.

* If the lamp is turned on, stop and start the engine again to resume the operation.

3. OIL SENSOR LAMP (See Fig. 2-e)

When the level of the engine oil falls below the prescribed value, the alarm lamp lights up and the engine stops automatically. When the engine stops due to oil shortage, it can not be started anymore even by pulling the start knob (just the alarm lamp flickers). In such a case, replenish engine oil up to the mouth of the oil filling port. (Refer to page 6 for details about the oil replenishing procedure).

4. AUTO POWER SAVE SWITCH AND LAMP (See Fig. 2-r)

6. DC TERMINALS (See Fig. 2-t)

DC electric power for battery charge is available. - Red is positive (+) terminal. - Black is negative (-) terminal.

R1700I(US)_GU2093 05.3.8 1:46 PM 5

6

E N

G L

IS H

F R

A N

A

IS E

E S

P A

O

L

4. PRE-OPERATION CHECKS (See Fig. 3) 1. CHECK ENGINE OIL (See Fig. 3-q,w)

Before checking or refilling oil, be sure generator is located on stable and level surface with engine stopped. Remove oil filler cap and check the engine oil level. If oil level is below the lower level line, refill

with suitable oil (see table) to upper level line. Do not screw in the oil filler cap when checking oil level.

Change oil if contaminated. (See "How-To" Maintenance.)

Oil capacity . . . . 0.4 liters (0.42 qts)

2. CHECK ENGINE FUEL (SeeFig. 2-o, 3-e)

If fuel level is low, refill with unleaded automotive gasoline.

Fuel level should never over the RED marking at the inlet portion. (SeeFig. 3-e-q) q RED MARKING

Be sure to use the fuel filter screen on the fuel filter neck.

q FUEL TANK CAP w FUEL FILTER SCREEN e TANK CAP COVER

Fuel tank capacity . . . 3.5 liters (0.92 US.gal) When using the generator first time or stopping

due the fuel running out, pull the recoil handle several times after filling fuel up to the RED marking at the inlet portion of the fuel tank.

Recommended engine oil: Use 4-stroke automotive detergent oil of API service class SE or higher grade (SG, SH or SJ is recommended). SAE 10W-30 or 10W-40 is recommended for general, all-temperature use. If single viscosity oil is used, select the appropriate viscosity for the average temperature in your area.

Ambient temperature

Single grade

Multigrade

5W 10W

20W #20

#30 #40

10W-30 10W-40

Do not refuel while smoking or near open flame or other such potential fire hazards. Otherwise fire accident may occur.

WARNING

7. DC CIRCUIT BREAKER (See Fig. 2-y)

DC circuit breakers shut off electric current when the current exceeds its limit or a malfunction occurs in the connected appliance. Check for excessive current consumption or defects in the appliance. After making sure everything is in order, push the button to the " ON " position.

q BUTTON e IN (ON) w KNOB r OUT (OFF)

9. RECOIL STARTER (See Fig. 2-u)

Pull this handle to start the generator.

q RECOIL STARTER HANDLE

q FUEL TANK CAP w FUEL FILTER SCREEN e TANK CAP COVER

8. GROUND TERMINAL (See Fig. 2-i)

Terminal for grounding the generator.

11. SIDE COVER (..) (See Fig. 2-!00) To access the following items for servicing, take the applicable side cover out by removing the screw with screwdriver or coin.

LH-side cover ---- Air cleaner etc.

RH-side cover ---- Oil level gauge, Ignition coil, Spark plug etc.

10. FUEL TANK CAP (See Fig. 2-o)

The fuel tank cap is located behind the cover. To open the cover, lift up with the dent portion depressed backward as shown in the illustration. Remove the fuel tank cap by turning counterclockwise.

If circuit breaker continues to be activated, discontinue use and check generator and/or appliance for malfunction with their respective service representatives. Never interfere with the operation of the circuit breaker knob or keep pushing it in the "ON" position.

CAUTION

R1700I(US)_GU2093 05.3.8 1:46 PM 6

7

E N

G L

IS H

F R

A N

A

IS E

E S

P A

O

L

Make sure you review each warning in order to prevent fire hazard.

Do not refill tank while engine is running or hot.

Before filling fuel, turn the engine switch into " " (STOP) position.

Be careful not to admit dust, dirt, water or other foreign objects Into fuel.

Wipe off spilt fuel thoroughly before starting engine.

Keep open flames away.

WARNING

3. CHECKING COMPONENT PARTS

Check following items before starting engine: Fuel leakage from fuel hose, etc. Bolts and nuts for looseness. Components for damage or breakage. Generator not resting on or against any

adjacent wiring.

If such grounding conductor or grounding electrode is unavailable, connect the grounding lug of the generator to the grounding terminal of the using electric tool or appliance. (See Fig. 2-i, 3-r)

q GROUND TERMINAL

w GROUNDING SPIKE

5. GROUNDING THE GENERATOR To ground the generator to the earth, connect

the grounding lug of the generator to the grounding spike driven into the earth or to the conductor which has been already grounded to the earth. (See Fig. 3-r)

4. CHECK GENERATOR SURROUNDINGS.

Make sure you review each warning in order to prevent fire hazard. Keep area clear of in flammables or

other hazardous materials. Keep generator at least 3 feet (1 meter)

away from buildings or other structures. Only operate generator in a dry, well

ventilated area. Keep exhaust pipe clear of foreign

objects. Keep generator away from open flame.

No smoking! Keep generator on a stable and level

surface. Do not block generator air vents with

paper or other material.

WARNING

5. OPERATING PROCEDURES (See Fig. 4) 1. STARTING THE GENERATOR

(a) Make sure the appliance is disconnected.

(b)Turn engine switch to " "(CHOKE) position.

(When engine is warm or temperature is high,

start engine with the switch at " " (RUN)

position.) (See Fig. 4-q)

(c) Pull the starter handle slowly until passing the

compression point (resistance will be felt), then

return the handle to its original position and pull

briskly. (See Fig. 4-w)

q RECOIL STARTER HANDLE

w PULL BRISKLY

(d)After starting, allow the starter handle to return to

its original position with the handle still in your hand.

Check the oil level before each operations as outlined on page 6.

CAUTION

Do not connect defective appliances including lines and plugs.

Be sure appliances are not connected to generator when starting up. Starting the generator with an appliance connected could result in damage to the generator and/or appliance and in personal injury.

CAUTION

NOTE When engine fails to start after several attempts, repeat the starting procedures mentioned above with the engine switch placed at " " (RUN) position.

When listening the radio near by the generator, the radio sound may be disturbed on account of the radio wave condition and the radio performance.

R1700I(US)_GU2093 05.3.8 1:46 PM 7

8

E N

G L

IS H

F R

A N

A

IS E

E S

P A

O

L

Make sure that the appliance is switched OFF before connecting it to the generator.

Do not move the generator while it is running.

Be sure to ground the generator if the connected appliance is grounded. Failure to ground unit may lead to electrical shock.

WARNING

2. USING ELECTRIC POWER

CONTROL PANEL R1700i (60Hz-120V)

1 5

8

910

2 3 4

6

7

(e) After 20 to 30 seconds of warm-up is completed, turn the engine switch to " " (RUN) position. (See Fig. 4-e)

(f) Make sure the pilot lamp is on. This indicates that the generator is properly operating.

NOTE Please consult with the nearest dealer if the pilot lamp is turned off during the proper operation.

(1) AC APPLICATION (See Fig. 4-r) (a) Make sure the pilot lamp is turned on.

(b) Turn off the switch(es) of the electrical appliance(s) before connecting to the generator.

(c) Insert the plug(s) of the electrical appliance(s) into the receptacle. (See Fig. 4-r)

Check the amperage of the receptacles used referring to TABLE 1, and be sure not to take a current exceeding the specified amperage.

Be sure that the total wattage of all appliances dose not exceed the rated output of the generator.

q PILOT LAMP

w OVERLOAD LAMP

e OIL SENSOR LAMP

r AUTO POWER SAVE LAMP

t AUTO POWER SAVE SWITCH

y AC RECEPTACLES

u DC TERMINALS

i DC CIRCUIT BREAKER

o GROUND TERMINAL

!0 ENGINE SWITCH

Up to 20A

Style Ampere

NEMA 5-20R

Receptacle

NEMA 5-20P

AC plug

GFCI (Ground Fault Circuit Interrupter) Receptacle, duplex

Description

TABLE 1

R1700I(US)_GU2093 05.3.8 1:46 PM 8

9

E N

G L

IS H

F R

A N

A

IS E

E S

P A

O

L

(d) Turn on the switch of the appliance.

NOTE If the generator is stopped with the overload pilot lamp turned on, the generator will be in the overload condition and/or the electrical appliance(s) would be out of order. In this case, stop the engine immediately and check the appliance and/or generator for overloading. After the check and remedy, restarting the engine will resume displaying in the normal manner.

(2) DC APPLICATION (See Fig. 4-t)

The DC terminal is used only for charging 12 volt batteries. It provides up to 12V-8.3A (100W) of maximum power.

q Positive terminal (RED)

w Negative terminal (BLACK)

CONNECTION OF CABLE : Connect positive terminal (red) on generator

to positive (+) terminal on battery.

Connect negative terminal (black) on generator to negative (-) terminal on battery.

Both AC and DC output can be used at the same time if the total output is within rated output of the generator.

SAFETY PRECAUTIONS WHILE CHARGING An explosive hydrogen gas is discharged

through vent holes in the battery during the charging process. Do not allow spark or open flame around the generator or battery during the charging process.

Electrolyte fluid can burn eyes and clothing. Be extremely careful to avoid contact. If injured, wash the affected area immediately with large quantities of water and consult a doctor for treatment.

When charging a large capacity battery or totally discharged battery, excessive current may force the DC breaker to turn off. In such cases, use a battery charger to charge a large battery with AC output.

Battery defects may cause the DC breaker to turn off. Check the battery before replacing the DC breaker.

STOPPING THE GENERATOR (a) Turn off the power switch of the electric

equipment and unplug the cord from receptacle of the generator.

(b) Allow the engine about 3 minutes to cool down at no load before stopping.

(c) Turn the engine switch to the position " " (STOP). (See Fig. 4-y)

OIL SENSOR (See Fig. 4-u)

(a) The oil sensor detects the fall in oil level in the crankcase and automatically stops the engine when the oil level falls below a predetermined level.

(b) When engine has stopped automatically, switch off generator's no fuse breaker, and check the oil level. Refill engine oil to the upper level as instructed on page 6 and restart the engine.

(c) If the engine dose not start by usual starting procedures, check the oil level

q OIL SENSOR

Do not remove OIL SENSOR PROBE when refilling with oil. Remove oil filler cap on the opposite side of carburetor.

CAUTION

Be sure to ground the generator if the connected electrical device is grounded.

Failure to ground unit could lead to electrical spark.

WARNING

Do not put foreign objects into the plug receptacle.

CAUTION

R1700I(US)_GU2093 05.3.8 1:46 PM 9

10

E N

G L

IS H

F R

A N

A

IS E

E S

P A

O

L

Electrical loads such as incandescent lamps and hot plates require the same wattage to start as is needed to maintain use.

Loads such as fluorescent lamps require 1.2 to 2 times the indicated wattage during start-up.

Loads for mercury lamps require 2 to 3 times the indicated wattage during start-up.

Electrical motors require a large starting current. Power requirements depend on the type of motor and its use. Once enough "surge" is attained to start the motor, the appliance will require only 50% to 30% of the wattage to continue running.

Most electrical tools require 1.2 to 3 times their wattage for running under load during use. For example, a 5000 watt generator can power a 1800 to 4000 watt electrical tool.

Loads such as submersible pumps and air compressors require a very large force to start. They need 3 to 5 times the normal running wattage in order to start. For example, a 5000 watt generator would only be able to drive a 1000 to 1700 watt pump.

Some appliances need a "surge" of energy when starting. This means that the amount of electrical power needed to start the appliance may exceed the amount needed to maintain its use. Electrical appliances and tools normally come with a label indicating voltage, cycles / Hz, amperage (amps) and electrical power needed to run the appliance or tool. Check with your nearest dealer or service center with questions regarding power surge of certain appliances or power tools.

6. WATTAGE INFORMATION

To determine the total wattage required to run a particular electrical appliance or tool, multiply the voltage figure of the appliance/tool by the amperage (amps) figure of same. The voltage and amperage (amps) information can be found on a name plate which is normally attached to electrical appliances and tools.

NOTE The following wattage chart is general guide only. Refer to your specific appliance for correct wattage.

Applicable Wattage (W)

60 Hz

approx. 1350

approx. 700

approx. 400

approx. 300

Applications

Incandescent lamp, Heater

Fluorescent lamp, Electric tool

Mercury lamp

Pump, Compressor

VOLTAGE DROP IN ELECTRIC EXTENSION CORDS

When a long electric extension cord is used to connect an appliance or tool to the generator, a certain amount of voltage drop or loss occurs in the extension cord which reduces the effective voltage available for the appliance or tool. The chart below has been prepared to illustrate the approximate voltage loss when an extension cord of 300 feet (approx. 100 meters) is used to connect an appliance or tool to the generator.

Nominal cross

section A.W.G. Allowable

current No.of strands / strands dia.

Resistance Current Amp.

No./mm /100mmm2 No. A 1A 3A 5A 8A 10A 12A 15A

0.75 18 7 30/0.18 2.477 2.5V 8V 12.5V

V o

lt ag

e d

ro p

1.27 16 12 50/0.16 1.486 1.5V 5V 7.5V 12V 15V 18V 2.0 14 17 37/0.26 0.952 1V 3V 5V 8V 10V 12V 15V

3.5 12 to 10 23 45/0.32 0.517 1.5V 2.5V 4V 5V 6.5V 7.5V

5.5 10 to 8 35 70/0.32 0.332 1V 2V 2.5V 3.5V 4V 5V

R1700I(US)_GU2093 05.3.8 1:46 PM 10

11

E N

G L

IS H

F R

A N

A

IS E

E S

P A

O

L

In a dry or wooded area, it is recommendable to use the product with a spark arrester. Some areas require the use of a spark arrester. Please check your local laws and regulations before operating your product.

The spark arrester must be cleaned regularly to keep it functioning as designed. A clogged spark arrester :

Prevents the flow of exhaust gas

Reduces engine output

Increases fuel consumption

Makes starting difficult

If the engine has been running, the muffler and the spark arrester will be very hot. Allow the muffler to cool before cleaning the spark arrester.

How to remove the spark arrester 1. Remove the flange bolts from the muffler cover and

remove the muffler cover.

2. Remove the special screw from the spark arrester and remove the spark arrester from the muffler.

SPARK ARRESTER SCREEN

SCREW

MUFFLER

Clean the spark arrester screen

Use a brush to remove carbon deposits from the spark

arrester screen.

Be careful to avoid damaging the screen.

The spark arrester must be free of breaks and holes.

Replace the spark arrester if it is damaged.

Install the spark arrester, and muffler protector in the

reverse order of disassembly.

SPARK ARESSTER SCREEN

7. SPARK ARRESTER

R1700I(US)_GU2093 05.3.8 1:46 PM 11

12

E N

G L

IS H

F R

A N

A

IS E

E S

P A

O

L

8. MAINTENANCE SCHEDULE

MAINTENANCE, REPLACEMENT OR REPAIR OF THE EMISSION CONTROL DEVICES AND SYSTEMS MAY BE PERFORMED BY ANY NONROAD ENGINE REPAIR ESTABLISHMENT OR INDIVIDUAL.

DAILY INSPECTION Before running the generator, check the following service items:

Excessive vibration,noise

Clean air cleaner element

Safe surroundings

Enough clean engine oil

Leakage of gasoline and engine oil

Loose or broken bolts and nuts

Enough gasoline

AC and DC terminals for damage

PERIODIC MAINTENANCE Periodic maintenance is vital to safe and efficient operation of your generator. Check the table below for periodic maintenance intervals. IT IS ALSO NECESSARY FOR THE USER OF THIS GENERATOR TO CONDUCT THE MAINTENANCE AND ADJUSTMENTS ON THE EMISSION- RELATED PARTS LISTED BELOW TO KEEP THE EMISSION CONTROL SYSTEM EFFECTIVE.

The emission control system consists of the following parts :

The maintenance schedule indicated in the table is based on the normal generator operation. Should the generator be operated in extremely dusty condition or in heavier loading condition, the maintenance intervals must be shortened depending on the contamination of oil, clogging of filter elements, wear of parts, and so on.

(1) Carburetor and internal parts

(2) Cold start enrichment system, if applicable

(3) Intake manifold, if applicable

(4) Air cleaner elements

(5) Spark plug

(6) Magneto or electronic ignition system

(7) Spark advance/retard system, if applicable

(8) Exhaust manifold, if applicable

(9) Hoses, belts, connectors, and assemblies

R1700I(US)_GU2093 05.3.8 1:46 PM 12

13

E N

G L

IS H

F R

A N

A

IS E

E S

P A

O

L

*Note: 1. Initial oil change should be performed after first twenty (20) hours of operation. Thereafter change oil every hundred (100) hours. Before changing oil, check for a suitable way to dispose of old oil. Do not pour it down into sewage drains, onto garden soil or into open streams. Your local zoning or environmental regulations will give you more detailed instructions on proper disposal.

*Note: 2. As to the procedures for these items, please refer to the SERVICE MANUAL or consult your nearest Robin service dealer.

Maintenance Items Every 1000 hours

Every 500

hours

Every 200 hours (Monthly)

Every 50 hours (Weekly)

Every 8 hours (Daily)

Clean generator and check bolt and nuts (Daily)

(Daily)

(Yearly)

(Daily)

(Daily)

Check and refill engine oil

Change engine oil (*Note1)

Clean spark plug

Clean air cleaner

Replace air cleaner element

Clean fuel filter

Remove carbon from cylinder head (*Note 2)

Check and adjust valve clearance (*Note 2)

Clean and adjust carburetor (*Note 2)

Replace fuel lines

Overhaul engine (*Note 2)

Clean spark arrester

Check AC receptacles

Clean and adjust spark plug and electrodes

Replace spark plug

Check engine switch

Check DC termianl

Check rotor

Check stator

Replace engine mount

Periodic Maintenance Schedule table

(Refill daily up to upper level)

(Initial 20 hours)

(Every 100 hours)

(Every 100 hours)

R1700I(US)_GU2093 05.3.8 1:46 PM 13

14

E N

G L

IS H

F R

A N

A

IS E

E S

P A

O

L

2. SERVICING THE AIR CLEANER (See Fig. 5-w)

Maintaining an air cleaner in proper condition is very important. Dirt induced through improperly installed, improperly serviced or inadequate elements damages and wears out engines. Keep the element always clean.

(a) Unhook the cover and remove the cleaner element. q ELEMENT w AIR CLEANER COVER

(b) Paper element: Clean by tapping gently to remove dirt and blow off dust. Never use oil. Clean paper element every 50 hours of operation, and replace element every 200 hours or once a year.

(c) Urethane form : Wash the element with fresh water. Squeeze out the water then dry the element. (Do not twist.)

3. CLEANING AND ADJUSTING SPARK PLUG (See Fig. 5-e,r)

q SPARK PLUG w PLUG WRENCH

(a) If the plug is contaminated with carbon, remove it using a plug cleaner or wire brush.

(b) Adjust the electrode gap to 0.6 to 0.7 mm (0.024 to 0.028 in.).

9. "HOW-TO" MAINTENANCE (See Fig. 5)

1. ENGINE OIL CHANGE (See Fig. 5-q)

q OIL DRAIN PLUG

Change engine oil every 50 hours. (For new engine, change oil after 20 hours.)

(a) Drain oil by removing the drain plug and the oil filler cap while the engine is warm.

(b) Reinstall the drain plug and fill the engine with oil until it reaches the upper level on the oil filler cap.

Use fresh and high quality lubricating oil to the specified level as directed on page 6. If contaminated or deteriorated oil is used or the quantity of the engine oil is not sufficient, the engine damage will result and its life will be greatly shortened.

Make sure the engine is stopped before starting any maintenance, servicing or repair.

CAUTION

10. PERIODIC OPERATION AND INSPECTION

When furnishing the generator as emergency

electric power source, periodic operation and

inspection are needed.

Fuel (gasoline) and engine oil will be deteriorated

with time, and this causes that the engine is

difficult to start and as the results improper

engine operation and fault.

Since the fuel (gasoline) will be deteriorated with time, replace fuel (gasoline) with fresh one periodically; once every three (3) months is recommended.

CAUTION

(a) Check the fuel (gasoline), engine oil and air cleaner.

(b) Start engine.

(c) With appliance such as lightings activated, run the engine for over ten minutes.

(d) Check for the following items;

Proper engine running.

Adequate output and the indicator lamp turned on properly.

The engine switch normally operated.

No leakage of engine oil and fuel (gasoline).

Spark plug BMR4A (NGK)

NOTE It is recommended to use ear protection when performing operation, maintenance and repair of the generator set.

R1700I(US)_GU2093 05.3.8 1:46 PM 14

12. PREPARATION FOR STORAGE

(See Fig. 6)

15

E N

G L

IS H

F R

A N

A

IS E

E S

P A

O

L

The following procedures should be followed prior to storage of your generator for periods of 6 months or longer.

Drain fuel from fuel tank carefully by disconnecting the fuel line. Gasoline left in the fuel tank will eventually deteriorate making engine-starting difficult.

When draining fuel from the fuel tank, use the hand pomp and set it into the refilling port. (See Fig. 6-q)

Remove the drain screw of the carburetor. (See Fig. 6-w) q DRAIN SCREW

Change engine oil.

Check for loose bolts and screws, tighten them if necessary.

Clean generator thoroughly with oiled cloth. Spray with preservative if available. NEVER USE WATER TO CLEAN GENERATOR !

Pull starter handle until resistance is felt, leaving handle in that position.

Store generator in a well ventilated, low humidity area.

11. TRANSPORTING When transporting the generator, make sure that

the fuel (gasoline) should be drained from the

tank.

(a) Turn the engine switch to the " " (STOP) position.

(b) Drain the fuel from the tank.

To prevent fuel spillage due to the vibration and impact, never transport the generator with the fuel (gasoline) filled in the tank.

Secure the tank cap thoroughly.

To avoid the risk of the gasoline flammability, never leave the generator in an area exposed to direct sunlight or high temperatures for a long time.

Keep the fuel (gasoline) in the exclusive gasoline storage tank made by steel when transporting.

WARNING

STOP RUN

CHOKE

(c) Secure the tank cap and set the cover in position.

TANK CAP COVER

FUEL TANK CAP

Do not place any heavy objects on the generator.

Select and place the generator in the proper position of the transport vehicle so that the generator not be moved or fallen down. Fix the generator with rope as necessary.

CAUTION

R1700I(US)_GU2093 05.3.8 1:46 PM 15

16

E N

G L

IS H

F R

A N

A

IS E

E S

P A

O

L

When generator engine fails to start after several attempts, or if no electricity is available at the output socket, check the following chart. If your generator still fails to start or generate electricity, contact your nearest Robin dealer or service shop for further information or corrective procedures.

13. TROUBLESHOOTING

Check if engine switch is in its proper position.

Check fuel level.

Check to make sure generator is not connected to an appliance.

Check spark plug for contamination.

Check engine oil level.

Check spark plug for loose spark plug cap.

Turn engine switch to " "(CHOKE) position.

If empty, refill fuel tank making sure not to overfill.

If connected, turn off the power switch on the connected appliance and unplug.

Remove spark plug and clean electrode.

If the engine oil level is low, add the oil to the upper level line on the oil gauge.

If loose, push spark plug cap back into place.

When Engine Fails to Start:

When No Electricity Is Generated at Receptacle :

Check if the DC circuit breaker is turned OFF.

Check if the Overload Lamp is turned ON (Red).

Check AC receptacle and DC terminals for loose connection.

Check to see if engine starting was attempted with appliances already connected to generator.

Depress the circuit breaker into ON position,

after making sure the electric appliances

are in the normal condition.

Stop the engine and check the appliances and/or generator for overloading.

Secure connection if necessary.

Turn off switch on the appliance, and disconnect cable from receptacle. Reconnect after generator has been started properly.

R1700I(US)_GU2093 05.3.8 1:46 PM 16

14. SPECIFICATIONS

17

E N

G L

IS H

F R

A N

A

IS E

E S

P A

O

L

MODEL G

en er

at o

r E

n g

in e

D im

en si

o n

R1700i

Type Multipole revolving field INVERTER type

Ground system Neutral ground (Neutral bonded to frame)

AC Output

Model

DC Output

120

11.2

1.35

Electoronic

12

8.3

EH09-2

Fuel Automobil unleaded gasoline

Starting system Recoil starter

Spark plug BMR4A (NGK)

Engine oil capacity L (U.S. gal) 0.4 (0.106)

Type Forced air-cooled,4-cycle,single cylinder OHV type gasoline engine

Displacement mL (cu.in.) 85.8 (5.23)

Length mm (in.)

Width mm (in.)

High mm (in.)

480 (19.3)

295 (11.6)

445 (17.5)

Dry weight kg (lb) 20.5 (45.2)

Fuel tank capacity L (U.S. gal) 3.5 (0.92)

Valve Clearance (Intake & Exhaust) mm(in.)

0.10.03 (0.00390.0012) Note : Adjust the valve clearance while the engine is cold.

Emissions Durability Period (California only) hours

Rated continuous operation [Approx.] hours 3.5

250

Rated Frequency Hz

Rated voltage V

Rated current A

Rated output kVA

2.1 / 4,200Rated output kW / rpm

Rated voltage V

Rated current A

Safety device ; type

Current breakerSafety device ; type

60

1.0Rated power factor

R1700I(US)_GU2093 05.3.8 1:46 PM 17

18

E N

G L

IS H

F R

A N

A

IS E

E S

P A

O

L

15.WIRING DIAGRAM

R1700i (60Hz-120V)

Blk : Black

Wiring color cord

Blk/W : Black/White Blu : Blue

LBlu : Light blue Brn : Brown Brn/W : Brown/White

Grn : Green Grn/W : Green/White Org : Orange

Gry : Gray R : Red W : White

Y : Yellow

Grn/Y : Green/Yellow

W/Blk : White/Black Pur : Purple

ENGINE SWITCH

Y

G ry

O rg YR B lu

Gry

R

W

Grn/Y

MAIN COIL

W

Blk

W

W

Grn/Y

AC RECEPTACLE

DC COIL

Pin Gry W

Blk

R Brn

G rn

/Y

Brn

W

RGrn Blu Pur Gry

Gry

Org

B rnW

WRB lu

INVERTER & ENGINE CONTROL UNIT

IGNITION COIL

PICKUP COIL

DC CIRCUIT BRAKER

EARTH (GROUND) TERMINAL

OIL LEVEL SENSOR

STEP MOTOR

DC OUTPUT TERMINAL

ENGINE CONTROL PANEL

LED INDICATOR

GENERATOR

AUTO POWER SAVE SWITCH

Y

Y/Blu

G rn

/Y

B lk

R1700I(US)_GU2093 05.3.8 1:46 PM 18

ISSUE EMD-GU2093

IMPRESO EN JAPN Marzo 2005 CE

Manualsnet FAQs

If you want to find out how the R1700i Subaru works, you can view and download the Subaru R1700i Generator User Instructions on the Manualsnet website.

Yes, we have the User Instructions for Subaru R1700i as well as other Subaru manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The User Instructions should include all the details that are needed to use a Subaru R1700i. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Subaru R1700i Generator User Instructions is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Subaru R1700i Generator User Instructions consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Subaru R1700i Generator User Instructions free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Subaru R1700i Generator User Instructions, simply download the document to your computer. Once downloaded, open the PDF file and print the Subaru R1700i Generator User Instructions as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.