Doc. no.XL-OMO0001-A

High Vacuum Angle Valve

PRODUCT NAME

XLC-25,40-F7NJ- Series MODEL/ Series

Thank you for purchasing this SMC product.

Be sure to read this Operation Manual carefully and understand its contents before

operating this product to ensure the safety of the operator and this product.

Please refer to the drawing and other informative documents for the construction and

specifications of this product.

Further, ensure your operating environment satisfies the requirements specified for the

product.

Keep this Operation Manual available whenever necessary.

Doc. no.XL-OMO0001-A

Contents

Safety Instructions - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1

1. Product Specific Precautions 1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3 (Precautions on Design, Selection, Mounting, Piping, Wiring, Maintenance)

2. Product Specific Precautions 2 - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5 (Maintenance parts)

3. Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6

4. Construction/ Dimensions - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8

5. Guaranteed term and range - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9

6. Parts replacement procedure - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10

- 1 -

XL-OMO0001-A

Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger. They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)*1), and other safety regulations. *1) ISO 4414: Pneumatic fluid power -- General rules relating to systems ISO 4413: Hydraulic fluid power -- General rules relating to systems IEC 60204-1: Safety of machinery -- Electrical equipment of machines (Part 1: General requirements) ISO 10218-1992: Manipulating industrial robots -- Safety

Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result

in minor or moderate injury.

Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could

result in death or serious injury.

Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result

in death or serious injury.

Warning 1. The compatibility of the product is the responsibility of the person who designs the

equipment or decides its specifications. Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment.

2. Only personnel with appropriate training should operate machinery and equipment. The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced.

3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed. 1.The inspection and maintenance of machinery/equipment should only be performed after measures to

prevent falling or runaway of the driven objects have been confirmed. 2.When the product is to be removed, confirm that the safety measures as mentioned above are implemented

and the power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully.

3.Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction. 4. Contact SMC beforehand and take special consideration of safety measures if the product is

to be used in any of the following conditions. 1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to

direct sunlight. 2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping,

vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog.

3. An application which could have negative effects on people, property, or animals requiring special safety analysis.

4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation.

- 2 -

XL-OMO0001-A

Safety Instructions

Caution 1.The product is provided for use in manufacturing industries.

The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.

Limited warranty and Disclaimer/Compliance Requirements The product used is subject to the following Limited warranty and Disclaimer and Compliance Requirements. Read and accept them before using the product.

Limited warranty and Disclaimer 1.The warranty period of the product is 1 year in service or 1.5 years after the product is

delivered,whichever is first.*2) Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch.

2.For any failure or damage reported within the warranty period which is clearly our responsibility, a

replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product.

3.Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in

the specified catalog for the particular products. *2) Vacuum pads are excluded from this 1 year warranty. A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or

failure due to the deterioration of rubber material are not covered by the limited warranty.

Compliance Requirements 1.The use of SMC products with production equipment for the manufacture of weapons of mass

destruction(WMD) or any other weapon is strictly prohibited.

2.The exports of SMC products or technology from one country to another are govemed by the relevant security laws and regulation of the countries involved in the transaction. Prior to the shipment of a SMC product to another country, assure that all local rules goveming that export are known and followed.

- 3 -

XL-OMO0001-A

1. Product Specific Precautions 1

Common Precautions 1 Be sure to read before handling. Design

Warning All models

1. The body material is A6063, the bellows is SUS316L, and other metal seal material is SUS304. Standard seal material in the vacuum section is FKM that can be changed to the other materials (please refer How to Order). Use fluids those are compatible with using materials after confirming.

2. Select materials for the actuation pressure piping, and heat resistance for fittings that are suitable for the applicable operating temperatures.

Models with auto switch 1. Keep the temperature of the switch below 150oC

With heater (thermistor) 1. When using a model with a heater, a mechanism to prevent overheating should be

installed.

Selection

All models 1. When controlling valve responsiveness, take note of the size and length of piping, as well

as the flow rate characteristics of the actuating solenoid valve. 2. Actuating press should be kept within the specified range.0.3 MPa to 0.5 MPa is

recommended. 3. Keep within the specified range of the pilot pressure.

High temperature type

1. If using gases that cause a large amount of deposits, heat the valve body to prevent deposits in the valve.

Mounting

All models 1. In high humidity environments, keep the valve packed until the time of installation. 2. For models with switches, secure the lead wires so that they have sufficient slack, without

any unreasonable force applied to them. 3. Perform piping so that excessive force is not applied to the flange sections. When there is

vibration from heavy objects or attachments, etc., fix piping so that vibration will not apply torque directly to the flange section.

4. Vibration resistance allows for normal operation of up to 30 m/s2 (45 to 250Hz), but continuous vibration may cause a decline in durability. Arrange piping to avoid excessive vibration or impacts.

High temperature type (temperature specification / H0 H4 H5) 1. In models with a heater (thermistor), take care not to damage the insulation components of the

lead wires and connector section. 2. The set temperature for models with a heater should be established without any drafts or heat

insulation. It will change depending on conditions such as heat insulation measures and the heating of other piping. Fine adjustment is not possible.

3. When installing heater accessories or mounting a heater, check insulation resistance at the actual operating temperature. A current leakage breaker or fuse should be installed.

4. If the valve is to be insulated, only the body should be insulated, excluding the bonnet part. 5. In models with a heater, when the heater is in operation, the entire valve becomes hot. Be

Caution

Caution

- 4 -

XL-OMO0001-A

careful not to touch it with bare hands, as burns will result.

1. Before mounting, clean the surface of the flange seal and the O-ring with ethanol, etc. 2. There is an indentation of 0.1 to 0.2mm in order to protect the flange seal surface, and it

should be handled so that the seal surface is not damaged in any way.

If the fluid or reaction product (deposit) may cause the valve to become unsafe, the valve should be disassembled, cleaned and re-assembled by an operator who has sufficient knowledge and experience (e.g. a specialist).

1. When removing deposits from the valve, take care not to damage any part of it. 2. Replace the bonnet assembly when the valve is approaching the end of its service life.

* For details regarding endurance cycles, please reference Section 5 of this Operation manual titled Period and scope of warranty. (pages 9)

3. If damage is suspected prior to the end of the service life, perform early maintenance. 4. SMC specified parts should be used for service. Refer to the Construction / Maintenance

parts table. 5. When removing the valve seal and external seal, take care not to damage the sealing

surfaces. When installing the valve seal and external seal, be sure that the O-ring is not twisted. (Refer to Section 6 Parts Replacement Procedure (pages 10 to 13) for details.)

Piping

Caution

Maintenance

Warning

Caution

- 5 -

XL-OMO0001-A

2. Product Specific Precautions 2

Common Precautions 2 Be sure to read before handling Maintenance Parts

Caution

The bonnet assembly should also be replaced when changing the seal material. Due to the different materials used, changing only the seal may prove inadequate. Bonnet assembly/construction part number:1

Valve size 25 40

XLC25-30-1H-F7// XLC40-30-1H-F7//

Note1) When an auto switch D-F7NJ is mounted, replace the part F7// of the model no. with F7NJL* (lead wire: 3,000mm) and F7NJZ* (lead wire: 5,000mm) *Mounting symbol/ number of auto switches: A: 1pcs on both side, B: 1pc on the open side, C: 1pc on the close side(ex. F7NJLA).

Note2) List the optional sealant material symbol after the model number, except for the

standard sealant material (FKM: compound No. 1349-80). Refer to the Construction of each series for the construction numbers.

External seal/Valve seal

Description Constructions no. Material

Valve size 25 40

External seal 3 Standard AS568-030V AS568-035V

Specific AS568-030** AS568-035**

Valve seal 2 Standard B2401-V24V B2401-P42V

Specific B2401-V24** B2401-P42**

Note1) List the optional sealant material symbol after the model number, except for the standard sealant material (FKM: compound no. 1349-80).

Note2) Refer to the Construction of each series for the construction numbers.

Additional symbols of the seal materials

Seal material EPDM Barrel

Perfluoro R Kalrez R Chemraz R VMQ

FKM for PLASMA

ULTIC ARMOR R

Combination No. 2101-80 70W 4079 SS592 SS630 SSE38 1232-70 3310-75 UA4640

Symbol -XN1 -XP1 -XQ1 -XR1 -XR2 -XR3 -XS1 -XT1 -XU1

Note1) Due to the different materials used, changing only the seal may prove inadequate. Barrel Perfluoro R is a registered trademark of MATSUMURA OIL Co.,Ltd. Kalrez R is a registered trademark of E. I. du Pont de Nemours and Company. Chemraz R is a registered trademark of Greene, Tweed & Co., ULTIC ARMOR R is a registered trademark of NIPPON VALQUA INDUSTRIES, LTD.

Auto switch mounting bracket For the auto switch D-F7NJ*, the mounting bracket XLA25-100 is used.

- 6 -

XL-OMO0001-A

3. Specifications 3-1. Vale specifications

Model XLC-25 XLC-40 Flange (valve) size 25 40

Actuating type Double acting/ activated by applying pressure Fluid Vacuum of inert gas

Operating temperature oC 5 to 150 Operating pressure Pa(abs) Atmospheric pressure to 1 x 10-6

Conductance l/s Note 1 14 45

Leakage

Pam3/s

Internal 1.3 x 10-10 for the standard material (FKM) at ambient temperature, excluding gas permeation

External 1.3 x 10-11 for the standard material (FKM) at ambient temperature, excluding gas permeation

Flange type KF(NW)

Main material Body: aluminum alloy, Bellows: SUS316L, Main part: SUS304 and FKM (standard sealing material)

Surface treatment for body Outside: hard anodized Inside: basis material Pilot pressure MPa (G) 0.3~0.6

Air consumption cm3 for 0.5MPa

Note 2

Main pumping 91 430

Port size M5 RC1/8 Weight kg 0.45 1.1

Note1) Conductance is molecular flow measured with an elbow pipe which has the same dimension as each applicable flange.

Note2) For one cycle of cylinder.

- 7 -

XL-OMO0001-A

3-2. Heater specifications Item XL-25 XL-40

Rated voltage of the heater 90 to 240 ACV

S y m b o l

H 4

Heater assembly number - XLA25-60S-1 No. of heater assemblies - 1 pc.

Initial power / Power consumption (W)

100 VAC - 200/40 200 VAC - 800/40

H 5

Heater assembly number XLA25-60S-1 XLA25-60S-2 No. of heater assemblies 1 pc. 1 pc.

Initial power / Power consumption (W)

100 VAC 200/40 400/70

200 VAC 800/40 1600/80 Note 1) Initial power and power consumption are nominal values.

The heaters are PTC thermistor type design. These

thermistors self regulate their temperature by

switching the resistance at certain critical

temperatures, so a separate temperature controller is

unnecessary.

If the temperature of the PTC heaters fitted exceeds

200oC, then it may fail. The maximum operating

temperature for the valve is 150oC. If the heater

temperature is over 200oC or valve temperature is

over 150oC, please use thermostat to control the

heaters to prevent overheating.

With PTC type heaters, there is an initial surge of

current (inrush current) after the power is supplied. These inrush current will reduce overtime. If

multiple heater assemblies are used, the inrush current to the heaters will be magnified and care

should be taken. When multiple heater assemblies or valves are used, do not apply power to the

heater assemblies simultaneously. Keep approximately 30 seconds between applications of power to

each heater assembly. This will allow for incremental spacing to prevent harmful large initial surge.

0 5 10 15 20 25 30

(

Time (sec.)

C ur

re nt

Duration of the inrush current flow (as a guide)

200V

100V

- 8 -

XL-OMO0001-A

1

2

4

5

( A6063)

( )

( )

( SUS304)

()

Ass 'y ()

) (

6

( SUS316L)

3 ()

7

( SUS304)

()

4. Construction / Dimensions mm

Model A B C D E Fn G H J K XLC-25 50 120 48 1 12 40 26 39 27.5 8 XLC-40 65 171 66 2 11 55 41 63 36 9

Auto switch

Valve (material: SUS304)

Valve seal (maintenance part)

Body (material: A6063)

Bellows (material: SUS316L)

External seal (maintenance part)

Bellows holder (material: SUS304)

Pilot Port (opened by applying pressure)

Bonnet assembly (maintenance part)

Port (closed by applying pressure)

Heater (option)

FF FF nn nn

( K F

)

A

AA AA

BB BB

()

CC CC EE EE

EE EE

C D

HH HH JJ JJ

G

K

Auto switch Heater (option)

K

F fl

an ge

- 9 -

XL-OMO0001-A

110 Pa

:

Blank flange

Test piece posture: lateral

Vacuum pump Durability test conditions

5 Guaranteed period and range The warranty period is 2 million cycles (under SMC endurance test conditions), 18 months

after delivery or 12 months in service, whichever comes first. Note) The product durability is varied depending on the operating conditions (such as a use with large flow rate). If the specification is not kept, or any non-conformance derived from mounting or replace of a device, an assembly, or an O-ring at your place occurs, the guarantee cannot be applied.

If any failure occurs due to our fault during the guaranteed period, we will guarantee the

non-conformance by delivering a substitute in the worst case. However, responsibility of any damage which is led by the product failure is not taken by us.

Result of durability test (with the circuit

shown on the right) Internal/ external leakage and operation

were checked by opening and closing a valve in internally evacuated condition at ordinary temperature (room temperature).

The test was performed with FKM, the standard sealing material.

The pumping direction is not limited, but if the pumping creates a flow stream, the endurance of the valve could be impaired. Therefore, the pumping direction shown on the right figure (bellows side pumping) is recommended. Also, the operating conditions should be checked beforehand because it affects the life.

Valve side

Chamber Bellows side

Vacuum pump Recommended direction of pumping

- 10 -

XL-OMO0001-A

6 Parts Replacement Procedure 6-1. Precautions

Be sure to follow [1. Precautions 1] when disassembling the product for maintenance. Along

with the precautions above, comply with the following precautions too.

Warning If it is expected that product materials may get stuck to the product, ensure safety is

assured before handling. It is recommended to wear gloves and a mask. Pay attention to the handling of components according to the procedure in the next item

onwards. Do not apply excessive force or impact. This will not only damage the product but also decrease its performance and life expectancy.

It is not possible to disassemble the bonnet assembly of this product. If the components and assembly are damaged, or damage is expected, exchange the bonnet assembly itself.

Do not disassemble the parts that are not explained in this operation manual. The performance and life may decrease. Also, it may cause danger.

- 11 -

XL-OMO0001-A

6-2. Disassembly procedure

Step 1 Step 2

The heater is removed by loosening bolt a. Bolt a is behind the cover. Remove the cover using a watchmaker's screwdriver. Loosen bolt b in numerical order to disassemble the body and the bonnet assembly.

Remove the O-ring from the groove for discharging gas using a plastic tool to prevent scratch the O-ring groove. (Take care not to scratch the O ring groove. >

Step 3

Remove the outer seal O-ring from the Body (Take care to prevent the mounting surface of O ring from being damaged )

1

Bolt b

Heater

Body

Bonnet assembly

2

3

4

O-ring

Bottom surface of the groove to discharge gas.

O-ring

Body

Cover

Installation surface of the O-ring

Bolt a

- 12 -

XL-OMO0001-A

6-3. Assembly Procedure

Step 1 Step 2

Assemble parts eliminating any dust or debris. Wipe off dust with a clean cloth soaked with ethanol. Blow parts with clean air if necessary. (Ensure there is no fibers or dust. )

Eliminate any dust within O-ring groove of the valve.

Step 3 Step 4

Wipe off any dust on the valve seal O ring surface. Place the O ring on the O ring groove. Press the O-ring into the groove in numerical order (press diagonally) to fit the O-ring into the groove. Take care not to twist the O ring. (Use dust-free gloves.)

Wipe off any dust from the external O-ring seal and the mounting surface of the Body. Place the O-ring on the O-ring mounting surface.

Clean cloth Valve

O-ring

1

3 4

2

O-ring

Installation surface of the O-ring

Ethanol

O ring groove

Body

- 13 -

XL-OMO0001-A

Step 5

Wipe off any dust from the valve seal O-ring and the Bellows holder surface.

Step 6

Tighten bolt b in numerical order to assemble the Body and the Bonnet assembly. When tightening bolt b, tighten manually until the O ring is compressed, then perform extra tightening in diagonal order. For models with heater, tighten bolt a to mount the heater to the body. Insert the cover.

Tightening torque of bolt b Nm Valve size

Tightening torque

XLC-25 1.5 -40 2.5

Tightening torque of bolt a Nm

Valve size Tightening torque

All sizes 0.3

O-ring

Bellows holder

1

Bolt b

Bolt a

Heater

Bonnet assembly

2

3

4

Cover

Body

- 14 -

XL-OMO0001-A

Revision history

Limited

Manualsnet FAQs

If you want to find out how the XLC-25 SMC works, you can view and download the SMC XLC-25,40-F7NJ Series Valve Operation Manual on the Manualsnet website.

Yes, we have the Operation Manual for SMC XLC-25 as well as other SMC manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Operation Manual should include all the details that are needed to use a SMC XLC-25. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the SMC XLC-25,40-F7NJ Series Valve Operation Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This SMC XLC-25,40-F7NJ Series Valve Operation Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download SMC XLC-25,40-F7NJ Series Valve Operation Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print SMC XLC-25,40-F7NJ Series Valve Operation Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the SMC XLC-25,40-F7NJ Series Valve Operation Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.