VBA-OM-S009

OPERATION MANUAL VBAT-M47A

AIR TANK VBAT20S1-T-X104 VBAT38S1-T-X104

Chinese Pressure Vessel Code Compliant Product

INDEX - Description and specifications of the components - Cautions for operation - Connecting Air tank and Booster regulator - Regular check

Thank you for choosing this SMC product. This operation manual provides essential information to ensure its optimum performance and lifespan. Please read it before using the product. Keep this manual accessible and refer to it if problems occur. Please refer to the latest catalogue, drawings and maintenance procedures for product configuration and specifications.

- Description and specifications of the components

Table 1 Specifications Model VBAT20S1-T-X104 VBAT38S1-T-X104

Max. operating pressure 1.0 MPa Material SUS304

Tank capacity 20 L 38 L Temp. range 0 to 75oC Tank mass 13kg 19kg

IN 1/2 OUT 1/2 3/4 Port size Drain 1/4

External surface treatment Acid cleaning Applicable booster regulator VBA2 / VBA4

Applicable standards TSG R0003-2007

Supervision Regulation on Safety Technology for Simple Pressure Vessels

Table 2 Accessories

Part name / Part No. Components Anchor bolt, nut For VBA2 / 4 mounting 4 pcs. Hex. socket head bolt For VBA2 / 4 mounting 4 pcs. O-ring For VBA2 / 4 mounting 1 pc.

Accessory set VBAT20S-Y-4

Hex. socket head plug For Drain port 1 pc.

Pressure gauge and safety valve set VBAT-T

Safety valve Pressure gauge Piping components for tank connection

1 pc. 1 pc. 1 pc.

Operation Manual/VBAT-M47 Operation Manual/VBAT-M47C

Operation Manual (Japanese) Operation Manual (Chinese)

1 copy 1 copy

V B

AT20S 1/ 38S

1-T-X 104

Product certificate Certificate 1 pc.

- Operating precautions - To ensure safety and optimum operation, confirm the products specifications before use. Operating product out of the scope of its

specifications may cause failure or accident.

WARNING Design precautions (1) Applicable standard - This air tank conforms to laws and regulations in China.

When this tank is used in countries outside of China, confirm that it is compliant with the laws and regulations of those countries. As the air tank is compliant with "Regulations on Safety Supervision of Special Equipment", the following procedures are

required when using the product. (Refer to "Regulations on Safety Supervision of Special Equipment Chapter 3" for details.) (1) To confirm that the pressure is set at the set value, submit the safety valve for air tank to the nearest Safety Inspection Bureau, and

store the safety valve together with the Check ticket. (2) Before installing the air tank, inform the nearest Special Equipment Safety Supervision Department in writing. (3) When installing the air tank, it should pass the inspection performed by the Inspection and Measurement Agency authorized by the

Special Equipment Safety Supervision Department based on the safety technical standard. [Documents supplied with the air tank, the Check ticket of the safety valve and the certificate supplied with the pressure gauge are necessary.]

(4) Register the product and related documents with the Special Equipment Safety Supervision Department before using the device or within 30 days after starting to use the device.

(2) Operating pressure - Use this air tank at maximum operating pressure of 1.0 MPa or less. (3) Connection - Install a filter or mist separator on the OUT side of the air tank as necessary. This air tank does not guarantee cleanliness (this product is for general industrial use).

CAUTION - Consider the operating conditions, and use this air tank within the specification range. - Do not supply or discharge air suddenly. This will cause the temperature to decrease due to air expansion, and the temperature may exceed the operating temperature limit of the air tank. If flow speed becomes faster, a loud noise may be generated by the friction inside the tube.

- When a booster regulator is used, select the appropriate product model according to the selection procedure of the energy saving program or How to Order in the catalog.

CAUTION Installation precautions (1) Accessories - Accessories are supplied attached to the foot of the tank. Once removed, take care not to lose any of the parts. (2) Installation - Operate the air tank fixed. - To mount the air tank on a floor surface, use the four holes of 13 to secure the tank with bolts (order separately) or anchor bolts (supplied with the product).

- Mount the air tank horizontally. If the tank is mounted vertically, the load will be concentrated on one foot, leading to breakage. - If the air tank is used where there is vibration, it may lead to breakage of the feet and the body. Please take anti-vibration measures. - A lot of energy builds up if high pressure is applied to the air tank. If the air tank breaks and air is discharged, a large blast of air will be generated and is very dangerous. Install the air tank where operations or equipment will not be affected.

- When connecting a booster regulator with an air tank, refer to the procedure Assembling the air tank and the booster regulator. (3) Piping - Connect piping so that the piping load and vibration are not applied to the tank socket. (4) Safety valve - Pressure setting cannot be changed as it is fixed. (5) Drain valve - The drain valve needs to be prepared by the user. SMC related product VBAT-V1 is available.

Related products

VBAT-V1

Drain valve

[MaterialCopper alloy] Order it separately

O-ring

IN port

Stand

Air tank

OUT port

Accessory set Drain port

Foot

Hex. socket head bolt

Hex. socket head plug Drain valve

Pressure gauge and safety valve set

Safety valve port

- Connecting Air Tank and Booster Regulator (1) Accessory check: Check the items and the quantity of parts in the package shown in Table 2.

(Accessories are attached to the foot of the air tank.)

(2) Prepare tools: Prepare a hexagon wrench key. The hexagon wrench key for

VBA2 is with nominal size 8, for VBA4 with nominal size 8 and 10,

and for the drain port with nominal size 6.

: Tighten the optional safety valve and drain valve and drain valve

with a monkey spanner.

(3) Change of the booster regulator OUT port plug

: Remove the hexagon socket head plug at the joint of the tank at the back

of the booster regulator. (Remove any sealing agent left on the thread.)

: Mount the hexagon socket head plug to the OUT port at the front of the

booster regulator by applying the seal tape.

VBA2: Tightening torque: 22 to 24 Nm (R3/8)

VBA4: Tightening torque: 28 to 30 Nm (R1/2)

(4) O-ring

: Mount O-rings in the grooves of the joint of the tank at the back side of the booster regulator.

(5) Mounting direction: When mounting the booster regulator to the air tank, the direction of IN of the booster regulator and

OUT of the air tank can be changed to suit the application.

(6) Installation: Tighten diagonally with the hexagon socket head bolts included in the package.

VBA2, 4: Tightening torque: 24 Nm (M10)

Assembly dimensions

Air tank Booster regulator A B C D E F G H I J K L M

VBA20A VBA22A

481 444 394 Rc3/8 59

VBAT20S1 VBA40A VBA42A

206 674 520 477 429.8

180 200 100 400 Rc1/2

Rc1/2 85

305 236

VBA20A VBA22A

531 494 444 Rc3/8 59

VBAT38S1 VBA40A VBA42A

256 824 570 527 479.8

205 250 150 500 Rc1/2

Rc3/4 85

355 250

- Maintenance

WARNING (1) Regular check - The user of the air tank shall keep a record of maintenance by making a special equipment safety technical document. - The use of pressure vessel could lead to an unexpected accident due to external damage or internal corrosion caused by

drainage. Therefore, make sure to check periodically for external damage, or the extent of internal corrosion through the port hole. An ultrasonic thickness indicator may also be used to check for any reduction in material thickness.

(2) Drain discharge - If the product is used with a large amount of drainage, the drainage could flow out, leading to equipment malfunction or

corrosion inside the tank. Do the drain pulling out regularly.

URL http://www.smcworld.com

Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021,JAPAN Phone: +81 3 5207 8249 Fax: +81 3 5298 5362 Specifications are subject to change without prior notice and any obligation the part of the manufacturer.

2008 SMC Corporation All Rights Reserved

Remove

OUT port Mounting

Groove O-ring

There should be no damage or dust

There is shaking on the diagonal

No gap

Air tank

Booster regulator

VBA4: Mounting holes (Outside)

VBA2: Mounting holes (Inside)

Mounting base

IN port (I)

Safety valve port Rc3/4

OUT port (J)

Drain port Rc1/4

IN port Rc1/2

413

Manualsnet FAQs

If you want to find out how the VBAT38S1-T-X104 SMC works, you can view and download the SMC VBAT38S1-T-X104 Tank Operation Manual on the Manualsnet website.

Yes, we have the Operation Manual for SMC VBAT38S1-T-X104 as well as other SMC manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Operation Manual should include all the details that are needed to use a SMC VBAT38S1-T-X104. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the SMC VBAT38S1-T-X104 Tank Operation Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This SMC VBAT38S1-T-X104 Tank Operation Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download SMC VBAT38S1-T-X104 Tank Operation Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print SMC VBAT38S1-T-X104 Tank Operation Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the SMC VBAT38S1-T-X104 Tank Operation Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.