VBA-OM-S009
OPERATION MANUAL VBAT-M47A
AIR TANK VBAT20S1-T-X104 VBAT38S1-T-X104
Chinese Pressure Vessel Code Compliant Product
INDEX - Description and specifications of the components - Cautions for operation - Connecting Air tank and Booster regulator - Regular check
Thank you for choosing this SMC product. This operation manual provides essential information to ensure its optimum performance and lifespan. Please read it before using the product. Keep this manual accessible and refer to it if problems occur. Please refer to the latest catalogue, drawings and maintenance procedures for product configuration and specifications.
- Description and specifications of the components
Table 1 Specifications Model VBAT20S1-T-X104 VBAT38S1-T-X104
Max. operating pressure 1.0 MPa Material SUS304
Tank capacity 20 L 38 L Temp. range 0 to 75oC Tank mass 13kg 19kg
IN 1/2 OUT 1/2 3/4 Port size Drain 1/4
External surface treatment Acid cleaning Applicable booster regulator VBA2 / VBA4
Applicable standards TSG R0003-2007
Supervision Regulation on Safety Technology for Simple Pressure Vessels
Table 2 Accessories
Part name / Part No. Components Anchor bolt, nut For VBA2 / 4 mounting 4 pcs. Hex. socket head bolt For VBA2 / 4 mounting 4 pcs. O-ring For VBA2 / 4 mounting 1 pc.
Accessory set VBAT20S-Y-4
Hex. socket head plug For Drain port 1 pc.
Pressure gauge and safety valve set VBAT-T
Safety valve Pressure gauge Piping components for tank connection
1 pc. 1 pc. 1 pc.
Operation Manual/VBAT-M47 Operation Manual/VBAT-M47C
Operation Manual (Japanese) Operation Manual (Chinese)
1 copy 1 copy
V B
AT20S 1/ 38S
1-T-X 104
Product certificate Certificate 1 pc.
- Operating precautions - To ensure safety and optimum operation, confirm the products specifications before use. Operating product out of the scope of its
specifications may cause failure or accident.
WARNING Design precautions (1) Applicable standard - This air tank conforms to laws and regulations in China.
When this tank is used in countries outside of China, confirm that it is compliant with the laws and regulations of those countries. As the air tank is compliant with "Regulations on Safety Supervision of Special Equipment", the following procedures are
required when using the product. (Refer to "Regulations on Safety Supervision of Special Equipment Chapter 3" for details.) (1) To confirm that the pressure is set at the set value, submit the safety valve for air tank to the nearest Safety Inspection Bureau, and
store the safety valve together with the Check ticket. (2) Before installing the air tank, inform the nearest Special Equipment Safety Supervision Department in writing. (3) When installing the air tank, it should pass the inspection performed by the Inspection and Measurement Agency authorized by the
Special Equipment Safety Supervision Department based on the safety technical standard. [Documents supplied with the air tank, the Check ticket of the safety valve and the certificate supplied with the pressure gauge are necessary.]
(4) Register the product and related documents with the Special Equipment Safety Supervision Department before using the device or within 30 days after starting to use the device.
(2) Operating pressure - Use this air tank at maximum operating pressure of 1.0 MPa or less. (3) Connection - Install a filter or mist separator on the OUT side of the air tank as necessary. This air tank does not guarantee cleanliness (this product is for general industrial use).
CAUTION - Consider the operating conditions, and use this air tank within the specification range. - Do not supply or discharge air suddenly. This will cause the temperature to decrease due to air expansion, and the temperature may exceed the operating temperature limit of the air tank. If flow speed becomes faster, a loud noise may be generated by the friction inside the tube.
- When a booster regulator is used, select the appropriate product model according to the selection procedure of the energy saving program or How to Order in the catalog.
CAUTION Installation precautions (1) Accessories - Accessories are supplied attached to the foot of the tank. Once removed, take care not to lose any of the parts. (2) Installation - Operate the air tank fixed. - To mount the air tank on a floor surface, use the four holes of 13 to secure the tank with bolts (order separately) or anchor bolts (supplied with the product).
- Mount the air tank horizontally. If the tank is mounted vertically, the load will be concentrated on one foot, leading to breakage. - If the air tank is used where there is vibration, it may lead to breakage of the feet and the body. Please take anti-vibration measures. - A lot of energy builds up if high pressure is applied to the air tank. If the air tank breaks and air is discharged, a large blast of air will be generated and is very dangerous. Install the air tank where operations or equipment will not be affected.
- When connecting a booster regulator with an air tank, refer to the procedure Assembling the air tank and the booster regulator. (3) Piping - Connect piping so that the piping load and vibration are not applied to the tank socket. (4) Safety valve - Pressure setting cannot be changed as it is fixed. (5) Drain valve - The drain valve needs to be prepared by the user. SMC related product VBAT-V1 is available.
Related products
VBAT-V1
Drain valve
[MaterialCopper alloy] Order it separately
O-ring
IN port
Stand
Air tank
OUT port
Accessory set Drain port
Foot
Hex. socket head bolt
Hex. socket head plug Drain valve
Pressure gauge and safety valve set
Safety valve port