Operation Manual -Process Pump PA5*13 Series-

Read this manual carefully and thoroughly before using.

For construction and specification etc. of this product, refer to drawing

and catalogue. The content of this operation manual is subject to

change without prior notification.

1. Precautions

Warning Environment When using hazardous fluid, take measures to keep people away from the pump. The occurrence of external

leakage could result in serious injury.

External leakage of transported fluid Fluid might leak externally due to life of diaphragm, and this could result in human injury or equipment damage.

Take measures against leakage.

Caution Quality of supply air Place filter with filtration 5m. Use air having better quality than No.B mentioned in catalogues of Air

Cleaning Equipment.

If a large amount of foreign matter comes from air source (carbon powder, etc.), take measures such as using

special lubricant, which generates less carbon powder or using mist-separator together with this pump.

Smooth operation might be hindered by resistance increased due to foreign matter pilled up.

Quality of transported fluid When using the pump to transport liquid which contains solid matter, install strainer mount the filter with

filtration of 0.2mm at least on IN port.

Life Span and Replacement Diaphragm should be changed before the life indicated. If diaphragm should be damaged, transported fluid will

leak into the pump and damage inner components.

Calculation method of diaphragm life. (varying with applications)

0.090 liter(discharge amount per one cycle)50 million cyclesreferential life cycle Referential life

date Operating frequency of

the solenoid valve (Hz)

x 60 (sec) x

operating time per

dayhour

x 60min.

2. Installment

Caution Mounting Mount in horizontal posture. Otherwise, internal parts may not operate smoothly and liquid is not transported.

Tighten mounting bolts (4pcs.) securely to avoid breakage of mounting bracket due to vibration.

Piping For piping to the port FLUID IN or FLUID OUT, tighten it securely with tooling such as spanner. Use flexible tube,

not steel pipe to avoid load applied to the ports. Excessive load applied to the inner seal could cause liquid

leakage.

Flush the piping thoroughly. When installing piping or a fitting into a port, ensure that sealant material and

cutting chips of threads do not enter piping. When using sealant tape, leave the first 2 threads exposed at the

end of piping /fitting. Tightening torque Under-tightening causes liquid or air

leakage while over-tightening causes

breakage of threads and other parts. Refer

to the table below for appropriate

tightening torque.

< Description and purpose of each port >

Suction port (FLUID IN) Sucking transported fluid

Discharge port (FLUID OUT) Discharging fluids sucked into the pump. Connect to the discharge port.

Pilot air supply port (AIR SUP) Supplying pressure set by regulator. Use clean air.

Connecting port Correct tightening torque(N) Rc(PT)1/4 Metal 1214 Rc(PT)1/2 Metal 2830 Rc(PT)3/8 Metal 2830

PAB-OM-C007-B 3. How to use

Caution Start & Stop

Connect air piping to the port P1 P2, and transported fluid piping to the suction port FLUID IN and the

discharge port FLUID OUT respectively.

Set pilot air pressure in the range of 0.2MPa and 0.5MPa by using regulator. Keep ball valve open on the

discharge side. Whenever solenoid valve at air source is energized, air is supplied and pump starts to operate.

Set the solenoid valves operating cycle frequency in between 15Hz. Fluid flows from the suction port FLUID IN to the discharge port FLUID OUT.

To stop the pump. Exhaust pressure supplied to the pump. Pump also stops when ball valve is closed on the

discharge side. Avoid stopping the pump for long hours., as this may prevent restart of the pump. Closing

valve abruptly can generates surge, that considerably shortens the life of the pump.

Discharge Flow Adjustment

Discharge flow rate could be adjusted by changing the solenoid valves operating cycle frequency.

Circuit(1) Circuit(2)

4. Maintenance

Caution During operation

Check liquid and air leakage, and operation conditions regularly during pump operation. If any abnormal

conditions or unclear matters are found, stop the pump immediately and contact SMC or the sales office you

purchased the pump.

Use protective tools such as anti-corrosive gloves to avoid a burn or other human injury when touching the

pump for check.

At stop

Exhaust the air on the SUP side if the pump will be stopped for a couple of hours.

Clean inside the pump to avoid clotting of transported liquid and sticking of internal parts if it will not be used

for a long period of time.

Check & Repair

Check liquid and air leakage, and operation conditions regularly during pump operation. If any abnormal

conditions or unclear matters are found, stop the pump immediately and contact SMC or the sales office you

purchased the pump.

Replace diaphragm before the indicated life cycles.

If diaphragm is broken due to the life, the operating fluid would flow out to the pilot air side. Leading to the

failure of pump.

5. Replacement parts

PTFE diaphragm set KT-PA5-31

Switching valve assembly set KT-PA5-36

FLUID

OUT

P1

P2 IN

FLUID

Manualsnet FAQs

If you want to find out how the PA513 Series SMC works, you can view and download the SMC PA513 Series Pump Operation Manual on the Manualsnet website.

Yes, we have the Operation Manual for SMC PA513 Series as well as other SMC manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Operation Manual should include all the details that are needed to use a SMC PA513 Series. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the SMC PA513 Series Pump Operation Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This SMC PA513 Series Pump Operation Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download SMC PA513 Series Pump Operation Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print SMC PA513 Series Pump Operation Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the SMC PA513 Series Pump Operation Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.