Safety Instructions

1. Product Specifications

1-1. Specifications

2. Operating Method / Operation

2-1. Design

2-2. Selection

2-3. Installation

2-4. Air supply

2-5. Piping

2-6. Operating environment

2-7. Lubrication

3. Maintenance

3-1. Precautions

3-2. Disassembly drawing

3-3. Finger assembly set replacement procedure

3-4. Seal replacement procedure

3-5. Construction / Parts list, seal list

-1-

Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger. They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)*1) , and other safety regulations. *1) ISO 4414: Pneumatic fluid power -- General rules relating to systems. ISO 4413: Hydraulic fluid power -- General rules relating to systems. IEC 60204-1: Safety of machinery -- Electrical equipment of machines .(Part 1: General requirements) ISO 10218: Manipulating industrial robots -Safety. etc.

Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.

Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.

Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.

Warning 1. The compatibility of the product is the responsibility of the person who designs the equipment or

decides its specifications. Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment.

2. Only personnel with appropriate training should operate machinery and equipment. The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced.

3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed. 1.The inspection and maintenance of machinery/equipment should only be performed after measures to

prevent falling or runaway of the driven objects have been confirmed. 2.When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully. 3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.

4. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions. 1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight. 2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping,

vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog.

3. An application which could have negative effects on people, property, or animals requiring special safety analysis.

4.Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation.

-2-

Safety Instructions

Caution The product is provided for use in manufacturing industries.

The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary.

If anything is unclear, contact your nearest sales branch.

Limited warranty and Disclaimer/Compliance Requirements The product used is subject to the following Limited warranty and Disclaimer and Compliance Requirements. Read and accept them before using the product.

Limited warranty and Disclaimer 1.The warranty period of the product is 1 year in service or 1.5 years after the product is

delivered,whichever is first. Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch.

2. For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage

incurred due to the failure of the product. 3. Prior to using SMC products, please read and understand the warranty terms and disclaimers

noted in the specified catalog for the particular products.

Compliance Requirements 1. The use of SMC products with production equipment for the manufacture of weapons of mass

destruction(WMD) or any other weapon is strictly prohibited.

2. The exports of SMC products or technology from one country to another are governed by the relevant security laws and regulation of the countries involved in the transaction. Prior to the shipment of a SMC product to another country, assure that all local rules governing that export are known and followed.

Caution SMC products are not intended for use as instruments for legal metrology. Measurement instruments that SMC manufactures or sells have not been qualified by type approval tests relevant to the metrology (measurement) laws of each country. Therefore, SMC products cannot be used for business or certification ordained by the metrology (measurement) laws of each country.

-3-

- 4 -

1. Product Specifications

1-1 Specifications Specifications

Model JMHZ2-8D JMHZ2-12D JMHZ2-16D JMHZ2-20D

Bore size (mm) 8 12 16 20

Fluid Air

Operating pressure [MPa] 0.15 to 0.7 0.1 to 0.7

Ambient and fluid temperature ( o C) 10 to 60

Repeatability (mm) 0.01

Maximum operating frequency (c.p.m.) 120

Lubrication Non-lube

Action Double acting

Holding force Actual value per finger

O.D. holding force 7.8 17.5 32.7 54.2

I.D. holding force 10.5 23.3 43.5 72.2

Opening/ closing stroke (both) (mm) 4. 6 10 14

Note 1) Weight [g] 31 65 128 240

Note 1) Excluding the auto switch weight.

- 5 -

2. Operating Method / Operation

2-1 Design ! Warning 1. The product is designed for use only in compressed air systems. Do not operate at

pressures or temperatures, etc., beyond the range of the specifications, as this can cause damage or malfunction of the cylinder and other equipment. (Refer to the specifications.) Please contact SMC if using fluids other than compressed air. The product cannot be guaranteed if is used outside of the specification range.

2. Take safety measures (e.g. mounting protective covers) when there is a danger of fingers being caught in a gripper or workpieces causing damage, etc.

3. There is a danger of workpieces dropping if there is a decrease in gripping force due to a drop in circuit pressure caused by a power failure or trouble with the air source. It is necessary to take measures such as drop prevention so that injury and damage to machinery or equipment can be prevented.

4. If the product is used for a purpose other than the transportation of a workpiece such as positioning or clamping, please consult SMC.

! Caution 1. Finite orbit type guide is used in the actuator finger part. By using this, when there are

inertial force which cause by movements or rotation to the actuator, steel ball will move to one side and this will cause a large resistance degrade the accuracy. When there are inertial force which cause by movements or rotation to the actuator, operate the finger to full stroke.

2-2 Selection ! Warning 1. The gripping point should be set within the limited range.

When the gripping point distance becomes large, the gripper attachment applies an excessively large load to the gripper sliding section, and causes adverse affects on the life of the gripper. Refer to the catalog for details.

2. Attachments should be designed to be as light and short as possible (1) A long or heavy attachment increases the inertia force required to open or close the

fingers. This may cause unsteady movement of fingers and have an adverse affect on the life of the gripper.

(2) Design the attachment to be as short and light as possible even if the gripping point is within the limited range. Refer to the catalogue for details.

L

H

H

H

L

L

"L" and "H" are appropriate "L" is too long "H" is too long

Gripping point

Gripping point

Gripping point

L Gripping point

- 6 -

(3) Select a larger size gripper or used two or more grippers for handling a long and/or large

workpiece.

3. Provide a run off space in the attachment when using with a small or thin workpiece. If a runoff space is not provided, gripping becomes unsteady, and it may lead to gripping failure or slippage.

4. Select a model that provides a gripping force with margin in relation to the workpiece weight. Incorrect selection may lead to dropping of the workpiece or othre troubles. Refer to the model selection criteria of each series for the effective gripping force and the workpiece mass.

5. Do not use the product in applications where excessive external force or impact force is applied. This can result in failure. Please consult with SMC if necessary.

6. Select a model having a sufficient working finger opening/closing width. < In case of insufficient width > (1) Gripping becomes unsteady due to variations in opening/closing width or workpiece

diameter. (2) When using an auto switch, the detection may not be reliable. Refer to the Auto Switch

Hysteresis section and set the stroke including the hysteresis length for reliable switch function. When using the water resistant 2-color indicator auto switch, the gripper stroke may be limited by the setting of the indicator color during detection.

2-3. Installation ! Warning

1. Install and operate the product only after reading the Operation Manual carefully and understanding its contents. Also, keep the manual where it can be referred to as necessary.

2. Allow sufficient space for maintenance and inspection. 3. Do not scratch or dent the air gripper by dropping or bumping it when mounting.

Slight deformation can cause inaccuracies or a malfunction. 4. Tighten the screw within the specified torque range when mounting the attachment.

Tightening with a torque above the limit can cause malfunction, while insufficient tightening can cause slippage and dropping.

Needle shaped workpiece

Runoff

space

Runoff

space

Thin sheet workpiece

- 7 -

How to mount attachment to the finger

Make sure to mount the attachments on fingers with the tightening torque in the table below by using bolts, etc., for the female threads on fingers.

5. Tighten the screw within the specified torque range when mounting the air gripper. Tightening with a torque above the limit can cause malfunction, while insufficient tightening can cause slippage and dropping.

How to Mount Air Gripper Axial mounting (Body tapped)

Lateral mounting (Body tapped)

Lateral mounting (Body through-hole)

Model Bolt

Max. tightening torque

(Nm)

Maximum screw-in depth

Depth [mm]

JMHZ2-8 M3 x 0.5 0.88 6

JMHZ2-12 M3 x 0.5 0.88 6

JMHZ2-16 M4x0.7 2.1 8

JMHZ2-20 M5 x 0.8 4.3 10

Model Bolt Max. tightening

torque

Nm

JMHZ2-8 M2.5x0.45 0.31

JMHZ2-12 M2.5x0.45 0.31

JMHZ2-16 M3 x 0.5 0.59

JMHZ2-20 M4x0.7 1.4

Model Bolt

Max. tightening torque

(Nm)

Max. thread depth L(mm)

Hole diameter

(mm)

Hole depth

(mm)

JMHZ2-8 M3 x 0.5 0.88 6 9H9 +0.036

0 2

JMHZ2-12 M3 x 0.5 0.88 6 13H9 +0.043

0 2

JMHZ2-16 M40.7 2.1 8 17H9 +0.043

0 2

JMHZ2-20 M5 x 0.8 4.3 10 21H9 +0.052

0 3

Refer to the catalogue for the dimension of the positioning pin.

Model Bolt

Max. tightening

torque

Nm

JMHZ2-8 M2.5x0.45 0.31

JMHZ2-12 M2.5x0.45 0.31

JMHZ2-16 M3x0.5 0.59

JMHZ2-20 M4x0.5 1.4

Attachment

Use the holes on the body

end surface for positioning.

- 8 -

! Caution

1. To mount the attachment to the finger, make sure not to apply undue strain on the finger. Any damage to the gripper may cause malfunction and reduce the accuracy.

2. Avoid external force to the finger. Fingers may be damaged by a continual lateral or impact load. Provide clearance to prevent the workpiece or the attachment from striking against any object at the stroke end.

1. Stroke end when fingers are open

2. Stroke end when gripper is moving

3. When turning over the gripper

Impact load

No clearance

C le

a ra

n c e

C le

a ra

n c e

Small clearance

Impact load

C le

a ra

n c e

Invert

Impact load

No clearance

C le

a ra

n c e

Small clearance

C le

a ra

n c e

- 9 -

3. Adjust the gripping point so that an excessive force will not be applied to the fingers when inserting a workpiece. Confirm that the gripper can operate without receiving any shock by testing it in manual operation mode or by low speed operation.

4. Control the opening/closing speed with the speed controller to avoid excessive high speed operation. If the finger opening/closing speed is greater than necessary, impact forces on the fingers and other parts will increase. This can cause a loss of repeatability when gripping a workpiece and have an adverse effect on the life of the gripper unit. It may be difficult to adjust the speed using meter-out control depending on the piping condition. In this case, adjust the speed using meter-in control or with dual speed controllers.

5. When elbow piping fittings are used, they may interfere each other or part of the air gripper, limiting the range for piping entry. Please use long elbow union: KQ2W or extension fitting to avoid this situation. Refer to the catalog for details.

Impact load

Not aligned Aligned

- 10 -

2-4 Air supply

! Warning 1. Please contact SMC when using the product in applications other than with compressed air. 2. Compressed air containing a large amount of condensate can cause malfunction of

pneumatic equipment. An air dryer or water separator should be installed upstream from filters.

3. If condensate in the drain bowl is not emptied on a regular basis, the condensate will overflow enter the compressed air lines. This will cause a malfunction of pneumatic equipment. If the drain bowl is difficult to check and remove, the installation of a drain bowl with an auto drain option is recommended.

4. Use clean air. Do not use compressed air that contains chemicals, synthetic oils including organic solvents, salt or corrosive gases, etc., as it can cause damage or malfunction of equipment.

Refer to "SMC Air Preparation System" for further details on compressed air quality.

! Caution 1. When extremely dry air is used as the fluid, degradation of the lubrication properties

inside the equipment may occur, resulting in reduced reliability (or reduced service life) of the equipment. Please consult with SMC.

2. Install air filters. Install an air filter at the upstream side of valve. A filtration degree of 5m or less should be selected.

3. Install an aftercooler, air dryer or drain catch before the filter and take appropriate measures. Compressed air that contains excessive foreign material may cause malfunction of valves and other pneumatic equipment. Therefore, take appropriate measures to ensure air quality, such as by providing an aftercooler, air dryer or water separator.

4. Use the product within the specified fluid and ambient temperature range. If the fluid temperature is 5

o C or less, the moisture in the circuit could freeze, causing

damage to the seals and leading to equipment malfunction. Therefore, take appropriate measures to prevent freezing.

Refer to "SMC Air Preparation System" for further details on compressed air quality.

2-5 Piping

! Caution

1. Refer to the Fittings and Tubing Precautions (Best Pneumatics) for handling one touch fittings.

2. Before piping Before piping, blow air (flush) or clean the piping to remove any cutting chips, cutting oil, dust, etc.

- 11 -

2-6. Operating environment

! Warning 1. Do not use in an environment where corrosive gases, chemicals, sea water, water or

steam are present. 2. Do not use in direct sunlight. 3. Do not operate in a location subject to vibration or impact. 4. Do not mount the product in locations where it is exposed to radiant heat. 5. Do not use this product in an area that is dusty, or in an environment in which water or oil

splashes on the cylinder.

! Caution 1. Martensitic stainless steel is used for the finger guide , so make sure that

anti-corrosiveness is inferior to the austenitic stainless steel. Especially, rust may be generated in environments that allow water drops from condensation to stay on the surface.

2-7. Lubrication ! Caution

1. The non-lube type air gripper is lubricated at the factory, and can be used without any further lubrication. If a lubricant is used in the system, use turbine oil Class 1 (with no additive) ISO VG32. Furthermore, once lubrication is applied, it must be continued. If lubrication is later stopped, malfunction can occur due to loss of the original lubricant. Refer to the Material Safety Data Sheet (MSDS) of the hydraulic fluid when supplying the fluid

- 12 -

3. Maintenance

3-1. Precautions ! Warning

1. Maintenance should be performed according to the procedure indicated in the Operation Manual. If handled improperly, malfunction and damage of machinery of equipment may occur.

2. If handled improperly, compressed air can be dangerous. Assembly, handling, repair and element replacement of pneumatic systems should be performed by a knowledgeable and experienced person.

3. Remove drainage moisture from air filters regularly. 4. When air grippers are removed, first confirm that measures are in place to prevent any

workpieces from dropping, run-away of equipment, etc. Then cut off the supply pressure and electric power and exhaust all compressed air from the system using the residual pressure release function. When the equipment is restarted, proceed with caution after confirming that appropriate measures are in place to prevent cylinders from sudden movement.

5. Do not allow people to enter or place objects in the carrying path of the air gripper. Otherwise, injury or an accident may occur.

6. Do not put hands, etc. in between the air gripper fingers or attachments. 7. When removing the air gripper, first confirm that no workpieces are being held and then

release the compressed air before removing the air gripper. If a workpiece is still being held, there is a danger of it being dropped.

- 13 -

3-2 Disassembly drawing

Finger assembly

Lever

Hexagon socket head cap

screws.

Body B Lever shaft

Rod cover

Gasket

Rod seal

Piston seal

Seal support

Piston assembly

Body A

Guide bolt

(Included in the finger

assembly set)

Seal kit

Hexagon

wrench

(Nominal)

Tightening

torque

(Nm)

8 2 0.36

12 2.5 0.63

16 3 1.5

20 4 3

Hexagon

wrench

(Nominal)

Tightening

torque

(Nm)

8 1.5 0.18

12 1.5 0.18

16 2 0.36

20 2.5 0.63

- 14 -

3-3. Finger assembly set replacement procedure (1) Direction of the body of the drawing below is recommended for mounting the finger

assembly to the body. Note) For 8, use a hexagon wrench with a ball end. Mount the finger assembly and the Body A with care so that the guide bolts do not interfere with the Body A.

(2) The guide may be displaced during tightening of the guide bolts. In order to avoid this displacement, place the guide and Body A on a flat surface and insert a spacer to fill the gap between the surface and guide (with reference line face down).

With across flat of the guide bolt and tightening torque

Width across

flats (Nominal)

Tightening torque (Nm)

Spacer size required

(mm)

8 2 0.36 1.7

12 2.5 0.63 1.2

16 3 1.5 1.2

25 4 3 2.4

Guide reference mark

Body A Air supply port

Block Surface plate

R a

is e

d p

a rt

- 15 -

3-4. Seal replacement procedure

(1) Loosen the guide bolts and remove

the finger assembly.

(2) Loosen hexagon socket head cap screws, and then remove them from the Body A.

(3) Push the seal support so that the rod cover comes out of the Body B end surface.

(4) Remove the lever shaft and lever.

(5) Pull out the rod cover and piston assembly and replace the seal. Assembly should be performed by following the removal procedure in reverse. Refer to the disassembly drawing for the tightening torque for the bolt. Use a specified grease. Specified grease pack part number: GR-S-010(10g)

Hexagon socket

head cap screws.

Body A Guide bolt

Body B

Seal support

Rod cover

Body B

Lever shaft Lever

Rod seal

Gasket

Piston seal

Needle roller

- 16 -

3-5. Construction / Parts list, seal list

Components

No. Parts description No. Description

1 Body A 8 Lever shaft

2 Piston assembly 9 Seal support

3 Lever 10 Rod cover

4 Guide 11 Steel ball

5 Finger 12 Rod seal

6 Roller stopper 13 Piston seal

7 Body B 14 Gasket

7 12 6

5 2 1 3

4

11 14

10 9 8 13

Replacement parts

Description JMHZ2-8 JMHZ2-12 JMHZ2-16 JMHZ2-20 Main part

Seal kit JMHZ8-PS JMHZ12-PS JMHZ16-PS JMHZ20-PS 12,13,14

Finger

assembly

JMHZ2- JMHZ-A0802 JMHZ-A1202 JMHZ-A1602 JMHZ-A1602 4,5,6,11

Mounting

screw

JMHZ2-1 JMHZ-A0802-1 JMHZ-A1202-1 JMHZ-A1602-1 JMHZ-A1602-1

JMHZ2-2 JMHZ-A0802-2 JMHZ-A1202-2 JMHZ-A1602-2 JMHZ-A1602-2

Piston assembly JMHZ-A0803 JMHZ-A1203 JMHZ-A1603 JMHZ-A2003 2

Lever assembly JMHZ-A0804 JMHZ-A1204 JMHZ-A1604 JMHZ-A2004 3

1= Side tapped 2=Through hole Replacement part/ grease package part no: number: GR-S-010 (10g)

Revision history

4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3

Manualsnet FAQs

If you want to find out how the JMHZ2-16D SMC works, you can view and download the SMC JMHZ2-16D Gripper Operation Manual on the Manualsnet website.

Yes, we have the Operation Manual for SMC JMHZ2-16D as well as other SMC manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Operation Manual should include all the details that are needed to use a SMC JMHZ2-16D. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the SMC JMHZ2-16D Gripper Operation Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This SMC JMHZ2-16D Gripper Operation Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download SMC JMHZ2-16D Gripper Operation Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print SMC JMHZ2-16D Gripper Operation Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the SMC JMHZ2-16D Gripper Operation Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.