Doc. no. AS*-OMO0058-A

PRODUCT NAME

SPEED CONTROLLER WITH ONE-TOUCH TUBE FITTING

IN-LINE TYPE

MODEL/ Series / Product Number

Contents

1Safety Instructions 2 3

2Specific Product Precautions 4 6

3Application 7

4Specifications 7

5Troubleshooting 7

6Construction 8

-1-

- 2 -

Speed Controller with One-Touch Tube Fitting

In-Line Type / AS Series

Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger. They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)*1) , and other safety regulations. *1) ISO 4414: Pneumatic fluid power -- General rules relating to systems. ISO 4413: Hydraulic fluid power -- General rules relating to systems. IEC 60204-1: Safety of machinery -- Electrical equipment of machines .(Part 1: General requirements) ISO 10218: Manipulating industrial robots -Safety. etc.

Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.

Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.

Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.

Warning 1. The compatibility of the product is the responsibility of the person who designs the equipment or

decides its specifications. Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment.

2. Only personnel with appropriate training should operate machinery and equipment. The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced.

3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed. 1.The inspection and maintenance of machinery/equipment should only be performed after measures to

prevent falling or runaway of the driven objects have been confirmed. 2.When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully. 3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.

4. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions. 1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight. 2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping,

vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog.

3. An application which could have negative effects on people, property, or animals requiring special safety analysis.

4.Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation.

- 3 -

Speed Controller with One-Touch Tube Fitting In-Line Type / AS Series

Safety Instructions

Caution The product is provided for use in manufacturing industries.

The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary.

If anything is unclear, contact your nearest sales branch.

Limited warranty and Disclaimer/Compliance Requirements The product used is subject to the following Limited warranty and Disclaimer and Compliance Requirements. Read and accept them before using the product.

Limited warranty and Disclaimer

1.The warranty period of the product is 1 year in service or 1.5 years after the product is delivered,whichever is first. Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch.

2. For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage

incurred due to the failure of the product. 3. Prior to using SMC products, please read and understand the warranty terms and disclaimers

noted in the specified catalog for the particular products.

Compliance Requirements

1. The use of SMC products with production equipment for the manufacture of weapons of mass destruction (WMD) or any other weapon is strictly prohibited.

2. The exports of SMC products or technology from one country to another are governed by the relevant security laws and regulation of the countries involved in the transaction. Prior to the shipment of a SMC product to another country, assure that all local rules governing that export are known and followed.

Caution SMC products are not intended for use as instruments for legal metrology.

Measurement instruments that SMC manufactures or sells have not been qualified by type approval tests relevant to the metrology (measurement) laws of each country.

Therefore, SMC products cannot be used for business or certification ordained by the metrology

(measurement) laws of each country.

! Caution

SMC products are not intended for use as instruments for legal metrology.

Measurement instruments that SMC manufactures or sells have not been qualified by type approval tests relevant to the metrology (measurement) laws of each country. Therefore, SMC products cannot be used for business or certification ordained by the metrology (measurement) laws of each country.

- 4 -

2. Specific Product Precautions

Warning (1) Confirm the specifications.

Do not operate at pressures or temperatures, etc., beyond the range of specifications, as this can cause damage or malfunction. (Refer to the specifications.) Contact SMC when using a fluid other than compressed air. We do not guarantee against damage if the product is used outside of the specifications.

(2) The product cannot be used as a stop valve to achieve zero leakage.

A certain amount of leakage is allowed in the products specifications. Tightening the needle to achieve zero leakage

may result in equipment damage. (3) No not disassemble the product or make any modifications.

An accident and/or injury may occur. (4) The flow characteristics are representative values for each product. Flow characteristics are for individual products. Actual values may differ depending on the piping, circuitry, pressure conditions, etc. Also, there are variations in the closed zero-position of the needle.

Warning (1) Operation Manual

Install and operate only after reading the operation manual carefully and understanding the contents. Keep the manual where is can be referred to if necessary.

(2) Maintenance space Allow sufficient space for maintenance and

inspection. (3) Confirm that the lock nut is tight.

If the lock nut is not tight, changes in the actuator speed may occur.

(4) Check the number of opening and closing rotations of the needle valve. It is not possible to remove the needle valve

completely, over rotation will cause damage to the product.

(5) Do not use tools such as pliers to rotate the handle.

If the knob is excessively rotated, it may cause damage.

(6) Mount after confirming the direction of flow. Mounting backwards is dangerous. The speed

adjustment needle will not work and the actuator may move suddenly.

Warning

(7) To adjust the speed, start with the needle in the closed position, and then adjust by opening gradually.

When the needle valve is open, the actuator may move suddenly. When the needle valve is turned clockwise (closed) the cylinder speed decreases. When the needle valve is turned counterclockwise (opened) the cylinder speed increases.

(8) Do not apply excessive force or shock to the body of fittings with an impact tools.

It can cause damage or air leakage. (9) Refer to the Fittings and Tubing Precautions

for handling One-touch fittings. (10) Tube O.D. 2 Tubing other than that from SMC cannot be used,

as it may not be possible to connect to the product.

Caution (1) The correct tightening torque for the lock

nut is shown below. Be careful not to over torque the product.

Caution (1) Refer to the Fittings and Tubing Precautions

for handling One-touch fittings. (2) Before piping Before piping, perform air blow (flushing) or

cleaning to remove cutting chips, cutting oil, dust, etc. from the pipe.

Design/ Selection

Installation

Installation

Piping

Model No.

Appropriate tightening

torque (Nm)

Lock nut Width across

flats

AS1002F-02 0.07 4.5

AS1002F 0.2 7

AS2002F 0.3 9

AS2052F 1 12

AS3002F 2 14

AS4002F 4 17

- 5 -

Warning (1) Type of fluids

The operating fluid must be compressed air. Contact SMC if using the product with other fluids.

(2) When there is a large amount of condensate

Compressed air containing a large amount of condensate can cause malfunction of pneumatic equipment. An air dryer or water droplet separator should be installed upstream from filters.

(3) Drain flushing If condensation in the drain bowl is not emptied

on a regular basis, the bowl will overflow and allow the condensation to enter the compressed air lines. This causes malfunction of pneumatic equipment. If the drain bowl is difficult to check and remove, installation of a drain bowl with an auto drain option is recommended.

For compressed air quality, refer to SMC catalog "Compressed Air Purification System". (4) Types of air

Do not use compressed air which contains chemicals, synthetic oils containing organic solvents, salts or corrosive gases, etc., as this can cause damage or malfunction.

Caution (1) Install an air filter.

Install an air filter close to the upstream side of the valve. A filtration degree of 5mm or less should be selected.

(2) Install an aftercooler, air dryer or water separator etc.

Do not use compressed air containing a lot of condensate, which can cause failure of the flow control or other pneumatic equipment. Install an aftercooler, air dryer or water droplet separator.

(3) Use the product within the specified fluid and ambient temperature range.

When operating at temperatures 5oC or lower, water in the circuit may freeze and cause breakage of seals or malfunction. Measures should be taken to prevent freezing.

For the details of compressed air mentioned above, refer to SMC catalog "Compressed Air Purification System".

Warning (1) Do not use in an environment where

corrosive gases, chemicals, sea water, water or steam are present.

For materials of the flow control equipment, refer to their construction drawings.

(2) Do not expose the product to direct sunlight for an extended period of time.

(3) Do not operate in a location subject to vibration or impact.

(4) Do not mount the product in locations where it is exposed to radiant heat.

Warning

(1)Maintenance should be performed according to the procedure indicated in the Operation Manual. Improper handling can cause damage and

malfunction of equipment and machinery. (2) Maintenance operations If handled improperly, compressed air can be

dangerous. A knowledgeable and experienced person should perform assembly, handling, repair and element replacement of pneumatic systems.

(3) Draining Remove condensate from air filters regularly. (4) Removal of equipment, and supply/exhaust

of compressed air When components are removed, first confirm that measures are in place to prevent workpieces from dropping and/or equipment running away, etc. Cut the supply pressure and electric power and exhaust all compressed air from the system. Before restarting the equipment, confirm that measures are taken to prevent sudden movement.

Air Supply

Maintenance

Operating environment

- 6 -

Caution

(1) Connection and disconnection of tube from one-touch fitting

Insertion of tube

1) Cut the tube perpendicularly, being careful not to damage the external surface. Use SMC's tube cuter TK-1, 2 or 3 for cutting. Do not cut the tube with pliers, nippers, scissors, etc. This may flatten the tube and connection to the fitting may fail, causing disconnection of the tube and air leakage.

2) The outside diameter of polyurethane tubing swells when internal pressure is applied, so it may not be possible to re-insert used tubing into One-touch fittings. Confirm the outside diameter of the tubing. If the accuracy of the outside diameter is +0.07mm or more for 2, and +0.15mm or more for other sizes, insert into the one-touch fitting again without cutting it. When tubing is re-inserted into a One-touch fitting, confirm that the tubing is able to go through the release button smoothly.

3) Hold the tube and push it in slowly, inserting it securely all the way into the fitting.

4) After inserting the tubing, pull on it gently to confirm that it will not come out. If it is not installed securely all the way into the fitting, problems such as leakage or disconnection of the tube can occur.

Removal of the tube 1) Press the release button firmly. Push the collar

evenly around its circumference. 2) Hold down the release button while pulling out

the tube. If the release button is not held down fully, it will be more difficult to pull out the tube.

3) If the removed tubing is to be used again, cut off the section of the tubing which has been gripped. Re-using the gripped portion of the tube can cause problems such as air leakage or difficulty in removing the tube.

(2) Connection of the metal rod accessories Do not use tube, resin plug, reducer, etc. after connecting a fitting with a metal rod (KC series, etc.) to a One-touch fitting. This can cause the tube to disconnect.

(3) When mounting the tube, resin plug or metal rod, do not press the release button. Do not press the release button unnecessarily before mounting tubing, resin plugs and metal rods. This can cause the tube to disconnect.

Caution

(4) When using tubing from a manufacturer other than SMC, be careful of the tolerance of the tubing O.D. and tubing material.

1) Nylon tubing Within 0.1 mm 2) Soft nylon tubing Within 0.1 mm 3) Polyurethane tubing Within +0.15 mm,

Within -0.2 mm Do not use tubing which does not satisfy the specified tubing O.D. accuracy, or tubing with an I.D., material, hardness, or surface roughness that differs from SMC's tubing. Please consult SMC if anything is unclear. It may cause difficulty in connecting the tubing, leakage, disconnection of the tubing, or fitting damage.

(5)Tubing O.D.2

Tubing other than that from SMC cannot be used because it may result in the inability to connect the tube, air leakage after connecting the tube, or disconnection of the tube.

(1) When connecting piping to the One-touch fitting, use a pipe length with sufficient margin, in accordance with the piping conditions shown in Figure 1. Also, when using a tying band, etc., to bind the piping together, make sure that external force does not come to bear on the fitting.

(See Fig.2)

Precautions for One-Touch Tube Fitting

Mounting/ Piping Mounting/ Piping

Recommended Piping Conditions

- 7 -

3. Application

This product is designed to control the speed of a pneumatic actuator.

4. Specifications

Model AS1002F AS2002F AS2052F AS3002F AS4002F

Tube O.D. Metric 2 3.2,4,6 4,6 6,8 6,8,10,12 10,12

Inch - 1/8",5/32,1/4 5/32",1/4" 1/4",5/16" 1/4",5/16",3/8" 3/8",1/2"

Fruid Air

Proof pressure 1.05MPa 1.5MPa

Max. operating pressure

0.7MPa 1.0Mpa

Min. operating pressure 0.1MPa

Ambient and fruid temperature -5 to 60 (No freezing)

Applicable tube material Note 1) Nylon ,Soft nylon, Polyurethane

Note 1) Note the max. operating pressure for soft nylon and polyurethane.

5 Troubleshooting

Trouble Possible causes Countermeasures

The speed (flow rate) cannot be controlled.

The product is mounted the wrong way round.

Check if the JIS symbol is suitable for the operating conditions.

Dust inside. Fully open the needle and apply air blow from the free flow side. If the problem is not solved even after air blow, install an air filter to the piping, and replace the product with a new one.

Air leaks from the One-touch fitting. Or the tube disconnects.

Tube has been cut using pliers or nipper.

Use a tube cutter.

The tolerance of the outside diameter of the tube is outside of the specification.

If tubing used is other than SMC, note the accuracy of the outside tolerances. Nylon tube: +/-0.1 mm at max. Soft nylon tube: +/-0.1 mm at max. Polyurethane tube: +0.15mm or -0.2 at max.

- 8 -

6 Construction

AS1002F, AS2002F, AS2052F

AS1002F-02 AS3002F, AS4002F

S

Revision history

A : Added the Safety Instructions sentences and

Manualsnet FAQs

If you want to find out how the AS02F Series SMC works, you can view and download the SMC AS02F Series Fitting Operation Manual on the Manualsnet website.

Yes, we have the Operation Manual for SMC AS02F Series as well as other SMC manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Operation Manual should include all the details that are needed to use a SMC AS02F Series. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the SMC AS02F Series Fitting Operation Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This SMC AS02F Series Fitting Operation Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download SMC AS02F Series Fitting Operation Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print SMC AS02F Series Fitting Operation Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the SMC AS02F Series Fitting Operation Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.