No.EX-OMY0032-A

PRODUCT NAME

Fieldbus system IO-Link Setting tool

MODEL / Series / Product Number

IO-Link Device Tool V5.1 PE

-1-

No.EX-OMY0032-A

Contents

1. Outline 2

2. System Requirements and How to Obtain the Software 3

3. Connection between an EX series and aPC 4

4. Software Installation 5

5. Starting the Software 8

6. Importing an IOLM File 9

7. Importing an IODD File 11

8. How to Use the Software 13

8.1. The IO-Link Module setting screen 13

8.1.1. Search Master 13

8.1.2. Individual selection 14

8.2. IO-Link Module Setting Screen 15

8.3. Common Screen 15

8.4. Port Config Screen 16

8.4.1. Reading the IO-Link Port Setting 16

8.4.2. Changing the Setting of the IO-Link Ports (for EX600-SEN3-X80 only) 17

8.4.3. Scanning IO-Link Devices 18

8.4.4. IO-Link Device Checking / Data Storage Function Setting (for EX600-SEN3-X80 only) 19

8.4.5. Port Config Details 20

8.5. Setting Screen 21

8.5.1. Reading IO-Link Module Parameters 21

8.5.2. Setting the IO-Link Module Parameters (for EX600-SEN3-X80 only) 22

8.6. Setting the IO-Link Devices 23

8.6.1. Reading Information on IO-Link Devices 23

8.6.2. IO-Link Device Process (Example using the ISE20B-L) 24

8.6.3. IO-Link Device Identification (Example using the ISE20B-L) 24

8.6.4. IO-Link Device Observation (Example using the ISE20B-L) 25

8.6.5. IO-Link Device Parameter (Example using the ISE20B-L) 26

8.6.6. IO-Link Device Diagnosis (Example using the ISE20B-L) 27

8.6.7. IO-Link Device Scope (Example using the ISE20B-L) 27

8.6.8. IO-Link Device Generic (Example using the ISE20B-L) 28

8.6.9. IO-Link Device IODD (Example using the ISE20B-L) 29

-2-

No.EX-OMY0032-A

1.Outline

The IO-Link Device Tool is an application software for IO-Link developed by Technologie Management Gruppe (TMG hereafter) in Germany, that makes the following operations possible for the IO-Link Module in the EX600 and 245 series.

- Monitoring various parameters of IO-Link Module - Monitoring and setting various parameters of IO-Link devices

Note: Applicable SI units and IO-Link Modules are as following. SI unit IO-Link Module EX600-SPN3

EX600-LAB1EX600-LBB1 EX600-SPN4 EX600-SEN3-X80 EX245-SPN1A

EX245-LA1EX245-LB1 EX245-SPN2A EX245-SPN3A

IO-Link Device Tool

IO-Link setting tool software

IO-Link Module

IODD filer

IO-Link device

Communication cable

-3-

No.EX-OMY0032-A

2.System Requirements and How to Obtain the Software

How to Obtain the Software

- IO-Link Device Tool After click Request for 30 days free version and quotation at the website below and register user iformation, IO-Link Device Tool file can be downloaded.

URLhttps://www.tmgte.de/en/products/io-link/io-link-device-tool-professional-edition.html - IOLM file IOLM file can be downloaded from the website below. URLhttps://www.smcworld.com Documents/Download >> Instruction Manuals >> Fieldbus System Serial Transmission System >>

IO-Link Module

License Key

- The IO-Link Device Tool can be used free of charge for 30 days after the first installation, but a license key is required after that period. A license key can be obtained in one of two ways:

1) Purchase one from TMG. Either CmActLicense (limited to a single PC) or a USB dongle (valid when

connected to any PC) => Contact TMG for details.

2) Purchase a USB dongle from SMC. Model No. EX9-ZSW-LDT1

Minimum System Requirements

Components Requirements Operating system Windows10 (32-and 64-bit) Memory 2GB Free hard disk space 150MB Processor 1GHz or higher,32-bit(x86) or 64-bit(x64) Screen resolution 800 600 pixels

Recommended System Requirements

Components Requirements Operating system Windows10 (32-and 64-bit) Memory 8GB Free hard disk space 250MB Processor 1GHz or higher,64-bit(x64) Screen resolution 1920 1080 pixels

-4-

No.EX-OMY0032-A

3.Connection between an EX series and a PC

Connect the EX series to a PC via a switching hub.

Fig. Example of a connection using a switching hub and EX600

Using the EX9-AC***EN-PSRJ cable, you can connect directly to either the BUS IN or the BUS OUT connector on the SI unit.

- Cable model

EX9-AC020EN -PSRJ Cable length (L) 010 1m 020 2m 030 3m 050 5m 100 10m

Fig. Example of a direct connection between a PC and SI unit(EX600)

BUS IN BUS OUT

M12 RJ45

Metal part Metal part

Switching hub

-5-

No.EX-OMY0032-A

4.Software Installation

Install the software according to the following procedure:

- If an old version of IO-Link Device Tool has been installed on the PC, be sure to uninstall it before installing the new version of IO-Link Device Tool.

- Double-click Setup.exe. The following screen will appear. - Select a language and then press [OK]. - Check the license terms, and if you agree, check "I accept the agreement" and then press [Next].

-6-

No.EX-OMY0032-A

- Select a folder to save the software and then press [Next]. - If you want to add a shortcut, check "Create a desktop shortcut" and then press [Next].

-7-

No.EX-OMY0032-A

- Check the installation conditions and if everything looks correct, press [Install]. - The above screen appears when the installation is successful. Then press [Finish].

The following description uses the manifold configuration example shown in Fig. 1.

Fig. 1 EX600 manifold configuration example

PCs IP address: 192.168.0.250 EX600s IP address: 192.168.0.1

L#B

IO-Link Module

Slot2

SPN#

SI Unit

Slot3

Valve

L#B

IO-Link Module

Slot1

End plate

-8-

No.EX-OMY0032-A

5.Starting the Software

- When the IO-Link Device Tool V#.# is started, the following screen appears. - Select the Help > Content, to refer to the User Manual prepared by TMG (read the manual for a detailed description of the operations).

- Select a user role depending on the user authorization. User roles Password setting Initial password Specialist Allowed special Maintenance Not allowed maintain Operator Not allowed None

* For details of the user roles, refer to the User Manual.

-9-

No.EX-OMY0032-A

6.Importing an IOLM File

To use the IO-Link Module in the EX600 and EX245 series for IO-Link Device Tool, an IOLM file must be imported which is dedicated to this purpose. For an EX600-SPN3/4 SI unit: SMC-EX600-SPN-LxB1-202*****-IOLM1.5zip For an EX600-SEN3-X80 SI unit: SMC-EX600-LxB1-202*****-IOLM.zip For an EX245-SPN1A SI unit: SMC-EX245-SPN_FX-Lx1-202*****-IOLM1.5zip For an EX245-SPN2A/3A SI unit: SMC-EX245-SPN_Cu-Lx1-202*****-IOLM1.5zip

- The following shows how to import an IOLM file.

(1) Select Options > Import IOLM (IO-Link Module Description).

(1)

-10-

No.EX-OMY0032-A

(2) Select a folder where the IOLM file in zip format is saved. (3) Press [OK]. (4) Check the IOLM file to be imported. (5) Press [Import]. (6) SMC-EX600 is added to the Module folder in the Catalog.

(2)

(4)

(3) (5) (6)

-11-

No.EX-OMY0032-A

7.Importing an IODD File

To set an IO-Link Device by using IO-Link Device Tool, an IODD file must be imported which is dedicated to this purpose.

- For how to obtain an IODD file, contact the manufacturer of your device. - How to import the IODD file of the SMC EX260-SIL1 is shown below.

The IODD file can be downloaded from the URL below. - URL: https://www.smcworld.com Documents/Download >> Instruction Manuals >> Fieldbus System Serial Transmission System >>

IO-Link Device>> EX260-SIL1 >> Configuration File

(1) Select the Option > Import IODD (IO Device Description).

(1)

-12-

No.EX-OMY0032-A

(2) Select the folder where the IODD file is saved. (3) Press [OK]. (4) Check the IODD file to be imported. (5) Press [Import]. (6) EX260-SIL is added to the IO-Link folder in the Catalog.

(2)

(4)

(3)

(5)

(6)

-13-

No.EX-OMY0032-A

8.How to Use the Software 8.1. The IO-Link Module setting screen 8.1.1. Search Master - After connecting the SI unit to a PC, supply power to the EX600 and conduct the operation as follows. Note: EX245 does not support the function of Search Master. (1) Press [Search Master]. (2) When the scanned EX600 is shown on the Master Discovery screen, double-click it with the left mouse

button. The IO-Link Module setting screen will appear.

(1)

(2)

* If the EX600 does not appear, perform the following. - Make sure an IP address has been set for the SI unit. - Turn off the EX600 and then turn it on again. - Restart the IO-Link Device Tool.

-14-

No.EX-OMY0032-A

8.1.2. Individual selection - After connecting the SI unit to a PC, supply power to the EX600 or EX245 and conduct the operation as follows.

(1) Select the IOLM file that matches the SI unit to be used. (2) Drag and move to Topology. The IO-Link Module setting screen will appear. (3) Press [Enter IP address] to display the input screen. (4) Input the IP address of the using SI unit. (5) Press [OK].

(3)

(4)

(5)

(1)

(2)

-15-

No.EX-OMY0032-A

8.2. IO-Link Module Setting Screen

- The IO-Link Module Setting Screen has the three tabs shown below. Selecting a tab changes the screen. Tab name Outline 1 Common Shows information such as the vendor ID of the EX600/245 which cannot change. 2 Port Config Shows information on devices connected to the ports of the EX600-L*B1 or EX245-L*1. 3 Settings Shows parameter setting information for the EX600-L*B1.

Note: EX245 does not support the Settings tab.

8.3. Common Screen - The Common Screen of the SMC-EX600/245 shows data that does not change such as the Vendor ID. (The image is an example of EX600.)

Item Outline 1 Vendor SMC Corporation, fixed value 2 IO-Link Vendor ID 0x0083, fixed value 3 Product name SMC-EX600-SPN3/SPN4, fixed value 4 IOLM Shows the name of the IOLM file being used. 5 IP Address Shows the IP address of the EX600-SPN3/4 being

monitored. 6 MAC Address Shows the MAC address of the EX600-SPN3/4 being

monitored.

(1) (2)

(3)

(4)

(5) (6)

-16-

No.EX-OMY0032-A

8.4. Port Config Screen 8.4.1. Reading the IO-Link Port Settings

- The following shows how to read the port settings of the EX600-L*B1 and EX245-L*1. (1) Set the status to [Go Online]. (2) Press [read from master] to read the port settings of the EX600-L*B1 or EX245-L*1.

Note: In the case of EX245, show from the IO-Link Module unit connected to the position nearest to the SI unit.

(1)

Shows the port mode settings of Ports 1 to 4 of the IO-Link Module unit connected to the position nearest to the end plate (Port 1, 2, 3, and 4 from the top).

Shows the port mode settings of Ports 1 to 4 of the IO-Link Module unit connected to the position second from the end plate (Port 1, 2, 3, and 4 from the top).

(2)

Offline Online

* When the port setting IOL_Manual and ValidationBackup is set as shown below, the set Vendor ID and the device with the Device ID are shown.

- Type compatible Device V1.1

-17-

No.EX-OMY0032-A

8.4.2. Changing the Settings of the IO-Link Ports (for EX600-SEN3-X80 only)

- The following shows how to change the port settings of the EX600-LAB1 and EX600-LBB1. (1) Set the status to [Go Offline]. (2) Place the cursor on [Mode] of the Port whose setting you want to change and right-click the mouse.

The settings for the port will be shown. (3) Place the cursor on the desired Port settingand left-click the mouse. [Mode] will be set to that setting. (4) When you press [Go Online], the "Synchronize Port Configuration" screen will appear. (5) Press [write to master] to apply the setting to the EX600-LAB1 or EX600-LBB1.

* When the SI unit is EX600-SPN* or EX245-SPN*A, use the configuration software of the PLC to change the parameters of EX600-L*B1 and EX245-L*1.

(1)(4)

(2) (3)

(5)

-18-

No.EX-OMY0032-A

8.4.3. Scanning IO-Link Devices

- The following shows the procedures for scanning IO-Link devices when communication with IO-Link devices connected to an EX600-L*B1 or EX245-L*1 is established.

(1) Set the status to [Go Online]. (2) Press [Check Devices]. The connected IO-Link devices will be shown. (3) Press [Takeover devices into engineering]. (4) Models, etc. of the connected IO-Link devices are shown.

(1) (2)

(3)

(4)

-19-

No.EX-OMY0032-A

8.4.4. IO-Link Device Checking / Data Storage Function Setting (for EX600-SEN3-X80 only)

- In the "Port Config Details" on the Port Config Screen of the SMC-EX600, the settings for the IO-Link device checking / Data storage function can be set for each port.

(1) Set the status to [Go Offline]. (2) Place the cursor on a port whose [Mode] is set to IO-Link. (3) In the device checking / data storage function setting in [IO-Link Mode], place the cursor on the desired

setting, and left-click the mouse. * For details on each setting, refer to the Operation Manual of the EX600-SEN3-X80.

(4) When the status is set to [Go Online], the Synchronize Port Configuration screen appears. Press the [write to master] button, to apply the setting to the EX600-LAB1 or EX600-LBB1.

* See page 18. * When the SI unit is EX600-SPN* or EX245-SPN*A, use the configuration software of the PLC to change the parameters of EX600-L*B1 and EX245-L*1.

(1)

(2)

(3)

-20-

No.EX-OMY0032-A

8.4.5. Port Config Details

- In "Port Config Details" on the Port Config screen of the SMC-EX600/245, information on connected IO-Link devices is shown.

(1) Place the cursor on a port to which an IO-Link device is connected. (2) The information on the selected IO-Link device is shown in "Port Config Details" as shown below.

Item Outline 1 Vendor ID Vendor ID 2 Device ID Device ID 3 Product ID Product ID 4 IODD IODD file name 5 Device PD Length Inputs Input size of the process data 6 Device PD Length Outputs Output size of the process data

(1)

(2)

-21-

No.EX-OMY0032-A

8.5. Settings Screen 8.5.1. Reading IO-Link Module Parameters

- Reading the parameters of the EX600-LAB1 and EX600-LBB1 can be performed using the following procedure.

- For details of the parameters, refer to the Operation Manual of the EX600-SPN3/4 or EX600-SEN3-X80. (1) Set the status to [Go Online]. (2) Select the Settings tab. The parameters of the unit selected in "List of Masters" will be shown. (3) The units can be selected in the List of Masters area. (4) "Maximum" of "Total Input/Output Size" shows the maximum acceptable configuration size that can be

occupied, and "Configured" shows the actually occupied configuration size (for the EX600-SEN3-X80 only).

Fig. Screen for the EX600-SPN3/4

Fig. Screen for the EX600-SEN3-X80

(1)

(3)

(2)

(1)

(3)

(2)

(4)

-22-

No.EX-OMY0032-A

8.5.2. Setting the IO-Link Module Parameters (for the EX600-SEN3-X80 only)

- Setting the parameters of the EX600-LAB1 and EX600-LBB1 can be performed with the following procedure.

- For details of the parameters, refer to the Operation Manual of the EX600-SEN3-X80. (1) Set the status to [Go Offline]. (2) Select the Settings tab. The parameters of the unit selected in "List of Masters" will be shown. (3) The units can be selected in the List of Masters area. (4) When the status is set to [Go Online] after changing the " Module Parameter," the "Synchronize Port

Configuration" screen appears. (5) Press [write to master] to apply the parameters to the unit.

* When the SI unit is EX600-SPN* or EX245-SPN*A, use the configuration software of the PLC to change the parameters of EX600-L*B1 and EX245-L*1.

(1)

(5)

(2)

(3)

(4)

-23-

No.EX-OMY0032-A

8.6. Setting the IO-Link Devices 8.6.1. Reading Information on IO-Link Devices

- Reading information on an IO-Link device can be performed using the following procedure. - The SMC ISE20B-L is used for the screen examples below (a special IODD file has been installed). * Screens differ depending on the IO-Link device. (1) Select an IO-Link device to read information, after setting the status to [Go Online], and double-click the

mouse. (2) The Common tab screen for the IO-Link device appears. (3) When the [Upload from device] button is pressed, the information on the connected device will be read.

(1)

(3) (2)

-24-

No.EX-OMY0032-A

8.6.2. IO-Link Device Process Data (Example using the ISE20B-L)

- When the "Process Data" tab of the ISE20B-L is selected, the following screen appears. - Pressure information, diagnostic information, and switch output status are shown.

8.6.3. IO-Link Device Identification (Example using the ISE20B-L)

- When the "Identification" tab of the ISE20B-L is selected, the following screen appears. - Only the "Application-Specific Tag" allows writing.

(1) When the [Upload from device] button is pressed, the information on the connected device will be read. (2) Select either the "block write mode" or "direct write mode" for the device writing mode. * For details of the difference between the writing modes, see the User Manual. (3) Any value within 32 characters can be set for the value of "Application-Specific Tag." To change this value, press the [Enter] button after directly entering the characters. (4) When the [Download to device] button is pressed, the device is written to.

(1)

(3)

(4) (2)

-25-

No.EX-OMY0032-A

8.6.4. IO-Link Device Observation (Example using the ISE20B-L)

- When the Observation tab of the ISE20B-L is selected, the following screen appears. - Pressure information, diagnostic information, and switch output status are shown.

(1) When the [Upload from device] button is pressed, the information on the connected device will be read.

(1)

-26-

No.EX-OMY0032-A

8.6.5. IO-Link Device Parameter (Example using the ISE20B-L)

- When the Parameter tab of the ISE20B-L is selected, the following screen appears. - The set parameters can be checked. - For details of the parameters, refer to the Operation Manual of the relevant IO-Link device.

(1) When the [Upload from device] button is pressed, the information on the connected device will be read. (2) Select either the "block write mode" or "direct write mode" for the device writing mode. * For details of the difference between the writing modes, refer to the User Manual. (3) Change "Value." ("State" will change to "c.") (4) When the [Download to device] button is pressed, the device is written to.

(1) (3)

(4) (2)

-27-

No.EX-OMY0032-A

8.6.6. IO-Link Device Diagnosis (Example using the ISE20B-L)

- When the Diagnosis tab of the ISE20B-L is selected, the following screen appears. - For details of the Diagnosis data, refer to the Operation Manual of the relevant IO-Link device.

(1) When the [Upload from device] button is pressed, the information on the connected device will be read.

8.6.7. IO-Link Device Scope (Example using the ISE20B-L)

- Process data of devices that support the Scope function can be shown in a chart format. (the scope of the ISE20B-L does not support this Scope function).

- For details on Scope, refer to the User Manual.

Chart

(1)

-28-

No.EX-OMY0032-A

8.6.8. IO-Link Device Generic (Example using the ISE20B-L)

- When the Generic tab of the ISE20B-L is selected, the following screen appears. - For details of the Generic data, refer to the Operation Manual of the relevant IO-Link device.

(1) When the [Upload from device] button is pressed, the information on the connected device will be read. (2) The information on Direct Parameter Page 1 is shown. (3) It allows users to view Process Data Inputs and to Read/Write Process Data Outputs. (4) It allows users to Read/Write parameters of IO-Link devices by specifying Index and SubIndex.

(1)

(3)

(2)

(4)

-29-

No.EX-OMY0032-A

8.6.9. IO-Link Device IODD (Example using the ISE20B-L)

- When the IODD tab of the ISE20B-L is selected, the following screen appears. - Detailed information on the IODD file is shown.

No.EX-OMY0032-A

Revision history AAddition of IO-Link modules EX245-L*1.

[April 2022]

4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL https://www.smcworld.com Note: Specificatio

Manualsnet FAQs

If you want to find out how the IO Link Device Tool V5 SMC works, you can view and download the SMC IO Link Device Tool V5,1 PE Fieldbus Operation Manual on the Manualsnet website.

Yes, we have the Operation Manual for SMC IO Link Device Tool V5 as well as other SMC manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Operation Manual should include all the details that are needed to use a SMC IO Link Device Tool V5. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the SMC IO Link Device Tool V5,1 PE Fieldbus Operation Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This SMC IO Link Device Tool V5,1 PE Fieldbus Operation Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download SMC IO Link Device Tool V5,1 PE Fieldbus Operation Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print SMC IO Link Device Tool V5,1 PE Fieldbus Operation Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the SMC IO Link Device Tool V5,1 PE Fieldbus Operation Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.