instructions for
torque wrenches model no: s0455.V2 & s0456.V2
thank you for purchasing a sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. sAFetY 99 9 ensure all workshop safety rules, regulations and conditions are complied with when using the torque wrench. 99 9 maintain thewrench in good condition and replace any damaged or worn parts. Use genuine parts only. Unauthorised parts
may be dangerous and will invalidate the warranty. 99 9 the wrench is a precision tool, Do not abuse it. 99 9 maintain correct balance and footing. ensure the floor is not slippery and wear non-slip shoes. 99 9 Keep children and unauthorised persons away from the working area. wArnInG! Do not use the wrench if damaged or thought to be faulty (contact service Agent). 98 9 Do not drop or throw the wrench. 98 9 Do not use wrench unless you have been instructed in its use by a qualified person. 98 9 Do not use any cleaner which might affect the high pressure grease with which the wrench it is packed. 9 After use adjust to lowest torque setting (but not below),clean and store in a safe, dry, childproof location.
2. iIntroDuctIon Heat treated steel ratchet head. fully hardened and tempered. chrome plated for corrosion resistance. micrometer type torque range adjustment. twist reverse ratchet mechanism. supplied in storage case.
3. ispecIFIcAtIon model no: ...................................................................s0455.V2 drive type: ......................................................................3/8sq. length: ..........................................................................365mm range: ....................................................19-110nm (14-81lb.ft)
model no: ...................................................................s0456.V2 drive type: ......................................................................1/2sq. length: ..........................................................................440mm range: ................................................. 42-410nm (40-155lb.ft)
4. ioperAtIon 4.1. Hold torque wrench in left hand (if right handed) so that required scale is uppermost and visible. 4.2. turn knurled lock screw at end of handle anticlockwise to unlock knurled adjusting grip. 4.3. turn adjusting grip to select torque setting as follows, for a required setting of 50nm: Turngripuntiltopedgeofgripislevelwiththe47Nmlineonthehandlescaleandthezerograduationonthegripisalignedwiththe centre line of the handle scale. Rotatehandlefurther,clockwise,until3rdgraduationongripisalignedwithcentrelinetogiveasettingof47+3=50Nm. note: Ifusingthekgmscaletheneachdivisiononthegripgraduationisequivalentto0.98Nm. therefore to set wrench at 4.5kgm: Turngripuntiltopedgeofgripislevelwiththe4.0kgmlineonthehandlescaleandthezerograduationonthegripisalignedwiththe centre line of the handle scale. Rotatethehandlefurther,clockwise,untilthe5thgraduationonthegripisalignedwiththecentrelinetogiveasettingof=4.5kgm. 4.4. tighten lock screw at end of handle to prevent accidental alteration of the setting. When tightening the nut/bolt you will feel and hear the wrench mechanism click when the set torque is reached. immediately stop applying force to wrench to avoid overtightening nut/bolt. Wrench will reset ready for next application. 4.5. Do not turn the handle below its lowest torque setting. note: if the wrench has not been used for some time, operate it a few times, at a low setting, to ensure all internal parts are coated in grease.
5. icAlIbrAtIon 5.1. Iftheuserdoesnotutilizeacontrolprocedure,aperiodof12months,or5000cycles,whicheveroccursfirst,maybetakenas
defaultvaluesfortheintervalbetweencalibrations.Theintervalstartswiththefirstuseofthetorquetool.Shorterintervalsbetween calibrations may be used if required by the user, their customer or by legislation.
s0455.V2,S0456.V2|Issue:107/06/17Original Language Version Jack sealey limited
refer to instruction
manual
Wear eye protection