Sealey 180XT.V2 Welder Instruction Manual PDF

1 of 8
1 of 8

Summary of Content for Sealey 180XT.V2 Welder Instruction Manual PDF

INSTRUCTIONS FOR

ARC WELDER 180XT.V2MODEL No:

Original Language Version 180XT.V2 Issue: 1 - 08/08/14 Jack Sealey Limited

This instruction manual contains the information required to prepare your arc welding set for welding. For Individual model specifications refer to part 2. The instructions are not intended to show you how to become a welder. If you have no experience, we recommend that you seek training from an expert source. Arc welding is relatively easy to perform, but does require a steady hand and time practising with scrap metal, as it is only with continued practice that you will achieve the desired results.

1.1. ELECTRICAL SAFETY WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following: You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual Current Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer. You must also read and understand the following instructions concerning electrical safety. 1.1.1. The Electricity at Work Act 1989 requires that all portable electrical appliances, if used on business premises, are tested by a qualified electrician, using a Portable Appliance Tester (PAT), at least once a year. 1.1.2. The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician. 1.1.3. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and 1.1.2. and use a Portable Appliance Tester. 1.1.4. Ensure that cables are always protected against short circuit and overload. 1.1.5. Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that none is loose. 1.1.6. Important: Ensure that the voltage marked on the appliance matches the power supply to be used and that the plug is fitted with the correct fuse - see fuse rating at right. 1.1.7. DO NOT pull or carry the appliance by the power cable. 1.1.8. DO NOT pull the plug from the socket by the cable. 1.1.9. DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty item repaired or replaced by a qualified electrician.

Original Language Version 180XT.V2 Issue: 1 - 08/08/14 Jack Sealey Limited

1.2. IMPORTANT : THE 180XT AND THE CAN BE CONNECTED TO EITHER A 16AMP SINGLE PHASE SUPPLY OR A PROPERLY INSTALLED 13AMP SUPPLY. TO ACHIEVE MAXIMUM OUTPUT HOWEVER A 16AMP FUSED SUPPLY SHOULD BE USED. WE RECOMMEND YOU DISCUSS THE INSTALLATION OF AN INDUSTRIAL ROUND PIN PLUG & SOCKET WITH A QUALIFIED ELECTRICIAN. 1.2.1. To fit a 13Amp plug proceed as shown on the right. Ensure the unit is correctly earthed via a three-pin plug. a) Connect the green/yellow earth wire to the earth terminal E. b) Connect the brown live wire to live terminal L. c) Connect the blue neutral wire to the neutral terminal N. After wiring, check there are no bare wires, that all wires have been correctly connected and that the wire restraint is tight. 1.2.2. Cable extension reels. When a cable extension reel is used it should be fully unwound before connection. A cable reel with an RCD fitted is recommended since any product which is plugged into the cable reel will be protected. The cross-section of the cable on the cable reel must be suitable for the unit and never lower than the cross-section of the main cable supplied with unit.

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.

INTRODUCTION

1. SAFETY

INSTRUCTIONS FOR:

ARC WELDER 180AMP WITH ACCESSORY KIT MODEL NO: 180XT.V2

1.3. GENERAL SAFETY WARNING! Arc welding produces sparks, fused metal projectiles and fumes which are dangerous. WARNING: Unplug from the mains power supply before performing maintenance or service. Keep the welder and cables in good working order and condition. Take immediate action to repair or replace damaged parts. Replace or repair damaged parts. Use genuine parts only, unauthorised parts may be dangerous and will invalidate the warranty. Keep the welder clean for best and safest performance. Locate welder in a suitable work area. Ensure area has adequate ventilation as welding fumes are harmful. Keep work area tidy and free from unrelated materials. Also ensure work area has adequate lighting and a fire extinguisher is at hand. WARNING: You MUST use an appropriate shaded lens welding face mask (contact your Sealey dealer for details). DANGER! Permanent eye damage may result if you do not use correct protection. Also wear safety welding gauntlets and dry, oil free safety protective clothing to protect yourself from sparks and hot droplets of fused metal. Cover exposed flesh to avoid potential burns from the ultraviolet rays of the arc. Use non-reflective welding curtains to protect other people in the area. Check you have good ventilation and that air can flow freely around the welder.

IMPORTANT INFORMATION: To operate all welders to their full capacity, you must run them on the correct power supply. To check the amperage, use the following formula: kVA Rating x 4.35 = Correct Amps Supply

3.1. Assembly, : (Refer to fig.1) 3.1.1 Lay a protective covering such as some cardboard packaging onto the floor and, with the help of another person, carefully turn the welder upside down onto it. Place the bent metal foot (6) onto the bottom of the casing just behind the front panel and fix it in place using three self tapping screws (7). 3.1.2 Assemble the wheels and axle as follows. Attach a circlip (8) to one end of the axle (5). Slide a wheel (3) onto the far end of the axle and move it across to the circlip ensuring that the recess in the wheel faces outwards. Insert the free end of the axle into the hole in the side of the casing as shown in fig.1 and guide it through the casing to emerge from the hole on the far side of the casing. Slide the other wheel (3) onto the axle and retain it with a circlip (8). Push a cap (4) into the recess in each wheel. With the help of another person, carefully turn the welder the right way up. 3.1.3 Attach the handle extension to the handle as follows. Take the handle extension (1) and push the large recessed spigot on its underside into the matching hole in the handle (2) as shown in fig.1. Secure the two parts together using the 25mm M5 bolt (9) provided. 3.1.4 Place the handle assembly onto the top of the casing and align it with the fixing holes. Secure the back end of the handle using an M6 16mm bolt (11), a split washer (12) and a flat washer (13) as shown in fig.1. Secure the front end of the handle using an M6 25mm bolt (10), a split washer (12) and a flat washer (13) as shown in fig.1.

Model No: 180XT Welding Current: 60-180A

Electrode Capacity: 2.0-4.0mm

Cooling: Forced Air

Output Cable 16mm

No-Load Voltage: 50V

Absorbed Power: 10kW

Supply: 230V

Weight: 23kg

DANGER! Ensure no flammable or combustible materials are near work area. Welding containers or pipes which hold, or have held dangerous gases or substances may explode or burn. Materials cleaned with chlorinated solvents, or varnished surfaces pose danger of toxic fumes. Keep unauthorised persons at a safe distance from the work area. Persons within the work area are subject to the same dangers as the welder and must take the same precautions. DO NOT weld on pressurised containers. Remove ties, watches, rings and other jewellery and contain long hair. DO NOT use the welder for any purpose other than that for which it is designed. DO NOT use the welder in damp or wet locations. DO NOT stand welder on a metal workbench, car bodywork or similar object. DO NOT touch any live metal parts of the torch or electrode while the machine is switched on. DO NOT weld without a welding safety head shield, gauntlets, clothing. DANGER! DO NOT weld near inflammable materials - solids, liquids, or gases. DO NOT operate welder while under the influence of drugs, alcohol or other medication, or if you are tired. DO NOT operate the welder if it or the cables are damaged. DO NOT allow untrained persons to operate the welder. DO NOT pull welder by the cable, or electrode holder. DO NOT bend or strain cables, protect from sharp or abrasive items. DO NOT stand on cables or leads. Protect from heat. Long lengths of slack must be gathered and neatly coiled. DO NOT place cables where they endanger others. DO NOT touch the electrode holder or workpiece immediately after welding as they will be very hot. Allow to cool. DO NOT open the cover of the machine. Switch off machine and remove the plug from the power supply after use. The electromagnetic fields generated by the welding process may interfere with the operation of electrical and electronic equipment. Users of vital electrical or electronic devices (e.g.pace-makers, respirators etc.) should consult a doctor before entering areas where welding machines are in use.(see Section 8). Users of vital electrical or electronic devices should not use any welding machine.

2. SPECIFICATIONS

DESCRIPTION

3. ASSEMBLY

Original Language Version 180XT.V2 Issue: 1 - 08/08/14 Jack Sealey Limited

Manufactured to exacting standards this model meets all relevant CE requirements. Fitted with a forced air cooling system, this welder has increased duty cycle and performance. It features a vented, wrap-around shell fitted to a heavy-duty chassis. Screw type, stepless welding control allows fine adjustment of current. Fitted with carry handle. Has wheels for added mobility. Supplied with accessory kit including electrode holder, cables, earth clamp, chipping hammer/wire brush.

fig.1

fig.2 fig.3

4. CONTROLS & SYMBOLS

Original Language Version 180XT.V2 Issue: 1 - 08/08/14 Jack Sealey Limited

fig.4

Original Language Version 180XT.V2 Issue: 1 - 08/08/14 Jack Sealey Limited

5. ENVIRONMENTAL CONDITIONS

Electrode Diameter (mm) ......Welding Current (Amp) 1.6 ................................25min ............... 50max 2.0 ................................40min ............... 80max 2.5 ................................60min ............... 110max 3.2 ................................80min ............... 160max 4.0 ................................105min ............. 185max 5.0 ................................130min ............. 220max

WARNING! If you have no welding experience, we recommend you seek supervised training from an expert source. 6.1. Introduction. Your welder features a single phase transformer with a drooping characteristic suitable for welding with an alternating current using stick electrodes with diameters from 1.5mm to the highest electrode diameter as shown on the chart below (See fig.7). 6.2. Current regulation. The intensity of the welding current can be adjusted continuously by means of a manually operated magnetic shunt. See fig.4.6. The value of the current (I) may be read in amps on the graduated scale on the top panel of the welder (See fig.3). 6.3. Thermostatic Protection. 6.3.1. Temperature Control Indicator Light. See Fig. 4.2. When the machine is overheating, it cuts off the power and the indicator light comes on. When the temperature has dropped to the recovery temperature, the machine can automatically restart and the indicator light will go off. 6.3.2 Temperature Protection Indicator Light. See Fig. 4.3. If the Temperature Controller fails, the protector will cut off the power and the indicator light comes on. Temperature protection can not resume automatically. If needed, please follow the methods below for recovery operations: 1. Turn off the machine's power. 2. Open the cover of the machine. 3. When the temperature protector pops up on the red contacts, such as in the picture right, it means the machine has cut off. 4. Press the red contacts on the thermal protection this means the machine is now in a normal state. As you use larger welding rods you may experience a temporary current shut off. The larger the welding rod, the greater the current required, consequently, the hotter the machine will become and the quicker it will cut out. 6.4. Setting up the welder. 6.4.1 Ensure the machine is turned off from the mains power supply. See fig.4.1. 6.4.2 Insert the quick connector for the work clamp lead into the socket marked with the work clamp symbol. See fig.4.5. Rotate the connector fully through 180 to ensure a secure connection. Attach the work clamp to a point on the workpiece that has been cleanly ground to provide good contact. Attach it as close as possible to the joint to be made. 6.4.3. Insert the quick connector for the electrode holder lead into the socket marked with the electrode holder symbol. Rotate the connector fully through 180 to ensure a secure connection. See fig.4.4. 6.4.4 Select the diameter of electrode to be used in relation to the type of joint to be made. Consideration should be given to the fact that higher current values should be used for flat welding, whereas for vertical or over head welding lower current values are required. Insert the electrode into the electrode holder. Ensure there is a good connection. Ensure welding surfaces are kept clean and free from grease, or oil. 6.4.5 Establish the welding current required in relation to the diameter of electrode you are using by making reference to the table below (fig.7.) 6.4.6 Set the current required in amps using the control wheel on the front panel. See fig.4.6. Turn the control clockwise to increase the current, and anti-clockwise to decrease the current. The current set can be read from the graduated scale on the top panel of the machine. See Fig.3. 6.5. Commencing welding. It is advisable to practice on scrap metal first especially where potentially difficult welds are to be undertaken. WARNING! Remember to wear a full face welding mask, gauntlets and protective clothing, and ensure you have read, understood and apply safety instructions. Wear goggles whilst chipping slag. 6.5.1 DO NOT switch on the power supply until you are fully ready to start welding. 6.5.3 Place the face mask in front of your face. 6.5.4 To strike the arc, tap the electrode lightly on the workpiece as if striking a match. DO NOT hit the electrode on the workpiece as this may damage the stick. 6.5.5 As soon as the arc is struck maintain a steady gap between the end of the electrode and the workpiece equal to the diameter of the electrode in use (See fig.5). Try to maintain this gap continuously through out the duration of the weld. The electrode should also be held at an angle of 20 to 30 from the vertical. (See fig.6). 6.5.6 At the end of the weld bead, move the tip of the electrode backwards in order to fill the weld crater. Quickly lift the electrode from the weld pool to extinguish the arc. Refer to fig.8 for a welding fault analysis. 6.5.7 If the electrode sticks, you may be holding it too close to the workpiece. Pull sharply to the left, and then to the right to free the electrode. 6.5.8 After welding, chip off the slag with the chipping hammer provided. Always wear goggles. 6.5.9 Disconnect welder from the mains power supply before resetting the electrode holder. WARNING! Use pliers to remove the hot consumed electrodes or to move the hot welded pieces.

fig.5

fig.6

fig.7 fig.8

5.1. Temperature. When welding, the temperature should not be below -10C or above 40C. During storage or transit the temperature should not fall below -25C or rise above 55C. 5.1.1 Humidity. The relative humidity should be no greater than 50% at 40C or 90% at 20C. 5.1.2 Altitude. The welder can be used up to 1000 Metres only.

6. OPERATION

Original Language Version 180XT.V2 Issue: 1 - 08/08/14 Jack Sealey Limited

8.1. THIS EQUIPMENT IS IN CONFORMITY WITH THE EUROPEAN STANDARD ON THE ELECTROMAGNETIC COMPATIBILITY OF ARC WELDING EQUIPMENT AND SIMILAR PROCESSES (e.g. ARC AND PLASMA CUTTING) 8.2. Protection against interference. (E.M.C.) The emission limits in this standard may not, however, provide full protection against interference to radio and television reception when the equipment is used closer than 30m to the receiving antenna. In special cases, when highly susceptible apparatus is being used in close proximity, additional mitigation measures may have to be employed in order to reduce the electromagnetic emissions. At the same time there could occur some potential difficulties in having electromagnetic compatibility in a non-industrial environment (e.g. in residential areas). Therefore it is most important that the equipment is used and installed according to the following instructions. 8.3. Installation and use. The user is responsible for installing and using the equipment according to these instructions. If electromagnetic disturbances are detected, then it shall be the responsibility of the user of the equipment to resolve the situation with the technical assistance of the supplier. In some cases this remedial action may be as simple as earthing the circuit (see Note). In other cases it could involve constructing an electromagnetic screen, enclosing the welding power source and the work, complete with associated input filters. In all cases the electromagnetic disturbances shall be reduced to the point where they are no longer troublesome. Note: The welding/cutting circuit may or may not be earthed for safety reasons. Changing the earthing arrangements should only be authorised by a person who is competent to assess whether the changes will increase the risk of injury, e.g. by allowing parallel welding/cutting circuit return paths which may damage the earth circuits of other equipment. Further guidance is given in IEC 974-13 Arc Welding Equipment - Installation and Use. 8.4. Assessment of area. Before installing the equipment the user shall make an assessment of potential electromechanical problems in the surrounding area. The size of the surrounding area to be considered will depend on the structure of the building and other activities that are taking place. The surrounding area may extend beyond the boundaries of the premises. The following shall be taken into account : a) Other supply cables, control cables, signalling and telephone cables, above, below and adjacent to the welding equipment. b) Radio and television transmitters and receivers. c) Computer and other control equipment. d) Safety critical equipment, e.g. security monitoring of industrial equipment. e) The health of people in the vicinity, e.g. persons fitted with a pacemaker or hearing aid. f) Equipment used for calibration or measurement. g) The immunity of other equipment in the environment. The user shall ensure that other equipment being used in the environment is compatible. This may require additional protective measures. h) The time of day that welding and other activities are to be carried out. 8.5. Mains supply. The equipment should be connected to the mains supply according to these instructions. If interference occurs, it may be necessary to take additional precautions such as filtering of the mains supply. Consideration should also be given to shielding the supply cable of permanently installed equipment in metallic conduit or equivalent. This shielding should be connected to the power source so that good electrical contact is maintained between the conduit and the welding power source enclosure. 8.6. Maintenance of the equipment. The equipment should be routinely maintained according to these instructions. All access and service covers should be closed and properly fastened when the welding equipment is in operation. The welding equipment should not be modified in any way except for those changes and adjustments covered in these instructions. In particular, the spark gaps of any arc striking and stabilising devices should be adjusted and maintained according to the instructions. 8.7. Cables. The welding/cutting cables should be kept as short as possible and should be positioned close together, running at or close to the floor level. 8.8. Equipotential bonding. Bonding of all metallic components in the welding/cutting installation and adjacent to it should be considered. However, metallic components bonded to the workpiece will increase the risk that the operator could receive a shock by touching these metallic components and the electrode at the same time. The operator should be insulated from all such bonded metallic components. 8.9. Earthing of the workpiece. It is important that the workpiece is separately bonded to earth in addition to the welder/cutter return cable. Where the workpiece is not bonded to earth for electrical safety reasons or because of its size and position, e.g. ships hull or building steelwork, a connection bonding the workpiece to earth may reduce emissions in some, but not all instances. Care should be taken to prevent the earthing of the workpiece increasing the risk of injury to others or damage to other electrical equipment. Where necessary, the connection of the workpiece to earth should be made by a direct connection to the workpiece, but in some countries where direct connection is not permitted, the bonding should be achieved by a suitable capacitance, selected according to national regulations. 8.10. Screening and shielding. Selective screening and shielding of other cables and equipment in the surrounding area may alleviate problems of interference. Screening of the entire welding/cutting installation may be considered for special applications.

8. ELECTROMAGNETIC COMPATIBILITY

WARNING! Ensure the welder is disconnected from the electrical mains power supply before attempting any service or maintenance tasks outlined below. 7.1. Keep the welder clean and dry at all times. Use a dry cloth to clean the unit. 7.2. Keep all electrodes clean and ensure all cables are in good condition. 7.3. Inspect the welder regularly, with a frequency depending on use and the dustiness of the environment. Remove dust deposits from the transformer using a jet of dry compressed air, (Max 10bar). 7.4. At the same time make sure that the electrical connections are tight and check the wiring for damage to the insulation. 7.5. If necessary use a very thin layer of high temperature grease, to lubricate the moving parts of the regulators (threaded shaft, sliding surfaces, shunts etc.). 7.6. After these light maintenance operations ensure that the welder covers are replaced and that all fastening screws are fully tightened . 7.7. Use an authorised service agent for any other maintenance or service requirements. WARNING! Never perform welding operations with the covers removed.

7. MAINTENANCE

Original Language Version 180XT.V2 Issue:1 - 08/08/14 Jack Sealey Limited

9.1. Machine frequently cuts out: (A)The welder is being overworked causing the thermostatic control to activate. (B) May also be due to a sticking electrode causing the machine to cut out for up to ten minutes. Cut out will automatically reset when welder has cooled. 9.2. Difficulty in striking an arc: a). The electrode is damp. Heat it up to 60 - 70 before using. b). Wrong type of electrode.

PROBLEM CAUSE SOLUTION Arc becomes unsteady or is difficult to strike

1. Input voltage too low 1. Ensure that the power supply is of the required specification for the welder.

2. Use of a thinner, non standard Welding cable resulting in too much resistance.

2. Use the correct cable as supplied with the machine.

3. Welding cable quick connector not properly tightened resulting in excessive resistance.

3 Ensure that cable quick connector is fully inserted and turned through 180.

4. Regulation screw and nut worn out. 4. Replace worn parts.

5. Faulty power switch 5. Replace power switch.

Welder overheats and cuts out 1. Welder overloaded 1. Wait for welder to cool down, then operate it within the requirements of the duty cycle.

2.Cooling fan broken 2. Repair or replace the cooling fan

Arc will not strike or is difficult to strike after the welder is switched on

1. No input voltage from power source 1. Check power source wiring, switch and fuse

2. Partial winding short circuit 2. Return welder to supplier for repair

Cooling fan not working 1. Faulty start up capacitor 1. Replace capacitor

2. Motor burned out 2. Replace motor

3. Faulty wiring 3. Check wiring

For all other problems refer to your local supplier

Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, email sales@sealey.co.uk or phone 01284 757500.

9. TROUBLESHOOTING

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice. IMPORTANT: No liability is accepted for incorrect use of this product. WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim. INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534 sales@sealey.co.uk

Sole UK Distributor, Sealey Group, Kempson Way, Suffolk Business Park, Bury St. Edmunds, Suffolk, IP32 7AR

www.sealey.co.uk

Environmental Protection

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.

When the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable) into approved containers and dispose of the product and the fluids according to local regulations.

WEEE Regulations Dispose of this product at the end of its working life in compliance with the EU Directive on

Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Cont

Manualsnet FAQs

If you want to find out how the 180XT.V2 Sealey works, you can view and download the Sealey 180XT.V2 Welder Instruction Manual on the Manualsnet website.

Yes, we have the Instruction Manual for Sealey 180XT.V2 as well as other Sealey manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Instruction Manual should include all the details that are needed to use a Sealey 180XT.V2. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Sealey 180XT.V2 Welder Instruction Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Sealey 180XT.V2 Welder Instruction Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Sealey 180XT.V2 Welder Instruction Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Sealey 180XT.V2 Welder Instruction Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Sealey 180XT.V2 Welder Instruction Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.