Sealey AK962EV.V2 Vernier Caliper Instruction Manual PDF

1 of 2
1 of 2

Summary of Content for Sealey AK962EV.V2 Vernier Caliper Instruction Manual PDF

Jack Sealey Limited Original Language Version

INSTRUCTIONS FOR:

ELECTRONIC VERNIER CALLIPER

MODEL NO: AK962EV.V2

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions and maintained properly, give you years of trouble free performance.

Refer to Instruction Manual

1. INTRODUCTION Hardened and tempered stainless steel digital calliper with satin finish. Large LCD display with 11mm high figures for ease of reading. Metric and Imperial calibration with conversion between the two. Zero setting control allows for comparative measurement. Supplied in storage case.

2. SPECIFICATION Model No: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AK962EV Range: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-150mm(0-6) Resolution:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.01mm(0.0005) Accuracy <100mm: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.02mm(0.001) Accuracy >100mm: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.03mm(0.001) Battery: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 x LR44 (supplied)

1 Internal Measure 5 LCD Display 9 Battery Cover 2 Metric/Imperial Selector 6 External Measure 10 Depth Measure 3 Locking Screw 7 On/Off Control 11 Step Measure 4 ABS/0 Switch 8 Zero Control

3. OPERATION DO NOT use the calliper if damaged. DO NOT use the calliper for any purpose other than for which it is designed. DO NOT get calliper wet or use in damp or wet locations, or areas where there is condensation. Keep calliper clean and dry using a dry cotton cloth only. DO NOT expose calliper to bright sunlight or dust. DO NOT apply any voltage to the calliper i.e. with an electric marker pen. The calliper is a precision instrument, treat with care, avoid using force and do not subject to knocks or shocks. Take particular care not to damage or scratch the scale surface. Use calliper in reasonably constant temperature conditions of approximately 20C When not in use, turn off and store calliper in a safe, dry, childproof location. 1. Ensure all measuring surfaces are clean and then turn on calliper by pressing on/off control. Wait at least one second before use. 2. Loosen locking screw and close calliper; if read-out does not show zero when in closed position, reset by pressing zero control. 3. Select inch or mm units, as required, with the metric/imperial selector. Check that display shows the required units. 4. Measurements will now be shown directly on the LCD display. 5. A new zero may be obtained, at any open position of the calliper, by pressing the zero control. 6. A second measurement that then also needs to be added to the first one can be obtained by pressing the ABS/0 switch after obtaining the first measurement (display will show INC), then move out the callipers to measure the second one. After noting this, press the ABS/0 switch again and the display will show the total of both measurements.

AK962EV.V2 Issue: 3 - 19/07/16

4. BATTERY FITTING A flashing display indicates that the battery is exhausted - replace as follows: 1. Switch off and then remove battery cover (9) by firmly sliding towards the right. 2. Remove exhausted battery and fit replacement with positive side uppermost (fig.1). Refit battery cover. 3. Dispose of old battery in a safe and approved manner. Do not burn. If the display fails to alter when the slide is moved, remove the battery - wait at least 30 seconds and then refit the battery.

fig.1

01284 757500

01284 703534 sales@sealey.co.uk

Sole UK Distributor, Sealey Group, Kempson Way, Suffolk Business Park, Bury St. Edmunds, Suffolk, IP32 7AR

www.sealey.co.uk

Environmental Protection Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable) into approved containers and dispose of the product and the fluids according to local regulations.

WEEE Regulations Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid waste authority for recycling information.

For battery removal details see section 4.

Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products containing batteries (as defined within these regulations), that they are registered with Valpaks registered compliance scheme. Jack Sealey Ltds Batteries Producer Registration Number (BPRN) is BPRN00705

NOTE: It is our policy to improve products continually and as such we reserve the right to alter data, specifications and component parts without prior notice. IMPORTANT: No liability is accepted for incorrect use of this product. WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

Jack Sealey Limited Original Language Version AK962EV.V

Manualsnet FAQs

If you want to find out how the AK962EV.V2 Sealey works, you can view and download the Sealey AK962EV.V2 Vernier Caliper Instruction Manual on the Manualsnet website.

Yes, we have the Instruction Manual for Sealey AK962EV.V2 as well as other Sealey manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Instruction Manual should include all the details that are needed to use a Sealey AK962EV.V2. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Sealey AK962EV.V2 Vernier Caliper Instruction Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Sealey AK962EV.V2 Vernier Caliper Instruction Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Sealey AK962EV.V2 Vernier Caliper Instruction Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Sealey AK962EV.V2 Vernier Caliper Instruction Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Sealey AK962EV.V2 Vernier Caliper Instruction Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.