INSTRUCTIONS FOR: MIG GAS REGULATORS MODEL NO'S: REG/MM.V2:REG/MMG.V2:REG/MZ.V2

Thank you for purchasing a Sealey Product. Manufactured to a high standard this product will,if used according to these instructions and properly maintained, give you years of trouble free performance.

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

1. SAFETY INSTRUCTIONS

2. INTRODUCTION & SPECIFICATION

Read the following instructions carefully before using the regulator, and keep them for future reference. The instructions provide all the information necessary for correct use of the regulator, to avoid damage and danger. SEALEY will not be responsible for any damage occurring due to incorrect use of the regulator, or to modifications made to it. This gas regulator is a delicate piece of workshop equipment. Failure to observe the following safety points will cause damage to the unit and will invalidate your warranty. Use Regulator only for gas intended. Use to designed pressure. Check for damage and leaks at frequent intervals. DO NOT knock or jolt regulator. DO NOT use a regulator showing any signs of damage. DO NOT allow cylinders to become heated. DO NOT use pressure gauges that are damaged, not smooth in operation or not zeroing. DO NOT overtighten adjusting knob as this will damage diaphragm and void warranty. DO NOT oil the regulator. WARNING! Incorrect use of the regulator can cause serious damage. Users must be trained by specialist engineers. WARNING! The regulator must be treated as a precision instrument. Protect it from accidental knocks, dust, oil and other sources of dirt. WARNING! Do not use the regulator if it is not in perfect working condition WARNING! When you draw gas, the cylinder must be placed upright and protected from falling.

2.1 Sealey Regulators are manufactured from only the highest quality materials and machined almost entirely automatically to fine tolerances. With correct use they will give reliable and trouble-free service. This regulator is only suitable for use with the shielding gases Carbon Dioxide, Argon or a mixture of these two gases (when used with the correct adaptor). Do not use for any other purpose.

MARKING KEY: (stamped on body) 1. K - Pressure reducer class 2. ID - Type of gas, see below

3. Manufacturing Lot 4. P1 - Max. Inlet Pressure 5. P2 - Max. Outlet Pressure

TYPE OF GAS ....... Code letter Acetylene ................................. A Oxygen ....................................O Hydrogen .................................H Compressed air .......................D

LPG .........................................P MPS .........................................Y Natural gas ............................. M CO, Nitrogen, Inert gas ..........N

2.2 SPECIFICATION: REG/MM.V2 REG/MMG.V2 REG/MZ.V2 Mini Refillable/Disposable Cylinder ..... Yes ....................Yes ....... Industrial Gauge ....................................................No ........................1 ................. No Argon/CO Adaptor ................................No ..................... No ................Yes Safe Working Pressure .................. 110bar ...............110bar ...........300bar Max Throughput ............................ 6ltr/min .............. 6ltr/min ........ 10ltr/min

2.3 Markings on body: REG/MM.V2 REG/MMG.V2 REG/MZ.V2 Pressure reducer class..........................K1 ......................K1 ................. K1 Gas Code ................................................N ....................... N ................... N P1 bar (INLET PRESSURE) ............... 110 .................... 110 ................300 P2 bar (OUTLET PRESSURE) ............... 4 ........................4 ....................4

REG/MM.V2, REG/MMG.V2, REG/MZ.V2 Issue No.2(C) 22/01/14Original Language Version

REG/MMG.V2

REG/MZ.V2

REG/MM.V2

Jack Sealey Limited

3. CONNECTION

4. OPERATION

5. STORAGE/MAINTENANCE

The function of the regulator is to reduce and control the pressure of a gas. The regulator reduces the pressure at which the gas is stored, to the pressure needed to use the gas. The regulator has been designed so as to be used only and exclusively with the type of gas and at the pressure which is shown by the markings stamped on the regulator body (refer to the markings key earlier in section 2).

WARNING! To try and use the regulator with types of gasses and pressures other than those indicated can be dangerous and will invalidate your warranty.

3.1 Mini Refillable/Disposable Cylinder. (REG/MM & REG/ MMG) 3.1.1 Check that the regulator is correct both for the type of gas and the pressure in the cylinder to be used. 3.1.2 Turn the pressure adjusting knob clockwiseto ensure that the regulator valve is closed. 3.1.3 Replace the inlet connection seal if it is damaged or lost. 3.1.4 Screw the regulator to the cylinder valve and tighten. DO NOT over-tighten. 3.2 Hose connection. 3.2.1 Attach hose to the outlet connection of the regulator by pushing it in as far as it will go. WARNING! Only use hoses complying with EN 559-ISO3821.

3.3 Connection to Industrial Gas Cylinder. (REG/MZ only) 3.3.1 Before screwing on the regulator, briefly open the cylinder valve, then close it, in order to remove any impurity (only for rechargeable bottles). WARNING! During this operation it is dangerous to stand, or place any parts of your body in front of the cylinder valve. 3.3.2. When using Argon or Argon mixtures, you will need to use the bull nose adaptor. Fit the bull nose adaptor to the cylinder with a spanner. (If you intend to use CO gas the regulator will fit directly onto the cylinder). 3.3.3 Screw the regulator to the bull nose adaptor or directly to the cylinder valve as required and tighten using a suitable spanner. DO NOT over-tighten. 3.4 Hose connection. 3.4.1 Push the gas supply tube onto the gas outlet nozzle on the regulator and retain it with a suitable clip/clamp. WARNING! Only use hoses complying with EN 559-ISO3821.

4.1 Operation with Mini Refillable/Disposable Cylinder. (REG/MM & REG/MMG.) 4.1.1 To increase pressure and flow slowly turn the regulator pressure adjusting knob anticlockwise. 4.1.2 To decrease pressure and flow slowly turn the regulator pressure adjusting knob clockwise. 4.1.3 Using the pressure adjusting knob it is possible to compensate for eventual pressure drop within the cylinder. CAUTION! Outlet pressure must not be regulated higher than the pressure you need to use. 4.2 Closing 4.2.1 Turn the pressure adjusting knob clockwise until it is completely closed. 4.2.2 Release the gas until the regulator gauges (if fitted) indicate "zero". 4.2.3 Remove regulator from cylinder.

5.1 STORAGE. 5.1.1 The regulator must be treated as a precision instrument. 5.1.2 When the regulator is not to be used for long periods, store it in its wrapping or in its box, to prevent contact with dust, oil and other sources of dirt. 5.2 MAINTENANCE. 5.2.1 Do not carry out maintenance or repairs, other than the following: Replacement of inlet seal. Replacement of gauge (if fitted). 5.2.2 Use only original spare parts and accessories. 5.2.3 Do not clean gauge glasses with petrol, solvents or any other kind of detergent. 5.2.4 In case of failure take your regulator back to the supplier. 5.3 Malfunctioning. 5.3.1 In case of malfunction (e.g. leaks in the gauges or in the relief valves) stop use and unscrew the regulator immediately from the bottle. 5.3.2 We suggest that the regulator be returned to the supplier to be checked and repaired. CAUTION! Do not use the regulator if there are the following malfunctions: The inlet seal is damaged or lost. The regulator or any of its parts (gauge, inlet connection, outlet connection) are damaged or dirty, oily etc. There are any leaky connections. The relief valve adjustment has been modified or the valve leaks. 5.4 Relief valve. 5.4.1 REG/MZ is equipped with an excess pressure valve. 5.4.2 In case of malfunctioning, this valve allows the excess gas pressure to escape. CAUTION! Do not modify the calibration of the relief valve. 5.5 Checking the seal 5.5.1 This check must be carried out only in the open air: use either soapy water or a gas leak detector. Do not use flames. 5.5.2 Spray detector on the area to be checked. 5.5.3 The forming of bubbles or foam is a sign of a leak. If a leak is detected remove regulator from service immediately and have it serviced by an authorised dealer.

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice. IMPORTANT: No liability is accepted for incorrect use of this product. WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim. INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534 sales@sealey.co.uk

Sole UK Distributor, Sealey Group, Kempson Way, Suffolk Business Park, Bury St. Edmunds, Suffolk, IP32 7AR

www.sealey.co.uk Web

email

4.3 Operation with Industrial Gas Cylinder. (REG/MZ only) CAUTION! Before opening the cylinder valve, ensure that the regulator is completely closed (turn the pressure adjusting knob anticlockwise). 4.3.1 Slowly open the cylinder valve. 4.3.2 To increase pressure and flow: slowly turn the regulator pressure adjusting knob clockwise. 4.3.3 To decrease pressure and flow: slowly turn the regulator pressure adjusting knob anticlockwise. 4.3.4 Using the pressure adjusting knob it is possible to compensate for eventual pressure drop within the cylinder. 4.4 Closing 4.4.1 Close the cylinder valve. 4.4.2 Release any gas remaining in the supply hose. 4.4.3 Turn the pressure adjusting knob (5) anticlockwise until it is completely closed. 4.4.4

Manualsnet FAQs

If you want to find out how the REG-MZ.V2 Sealey works, you can view and download the Sealey REG-MZ.V2 Regulator Instruction Manual on the Manualsnet website.

Yes, we have the Instruction Manual for Sealey REG-MZ.V2 as well as other Sealey manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Instruction Manual should include all the details that are needed to use a Sealey REG-MZ.V2. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Sealey REG-MZ.V2 Regulator Instruction Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Sealey REG-MZ.V2 Regulator Instruction Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Sealey REG-MZ.V2 Regulator Instruction Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Sealey REG-MZ.V2 Regulator Instruction Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Sealey REG-MZ.V2 Regulator Instruction Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.