Sealey SA661 Needle Scaler Instruction Manual PDF

1 of 3
1 of 3

Summary of Content for Sealey SA661 Needle Scaler Instruction Manual PDF

COMPOSITE AIR NEEDLE SCALER MODEL NO: SA661

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

SA661 Issue 4 01/07/20Original Language Version Jack Sealey Limited

1. SAFETY WARNING! Ensure health & safety, local authority, and general workshop practice regulations are adhered to when using this equipment. WARNING! Disconnect from air supply before changing accessories or servicing. 9 Maintain the needle scaler in good condition and replace any damaged or worn parts. Use genuine parts only. Unauthorised parts may be

dangerous and will invalidate the warranty. WARNING! Check correct air pressure is maintained and not exceeded. We recommend 90psi. 9 Keep air hose away from heat, oil and sharp edges. Check air hose for wear before each use and ensure that all connections are secure. 9 Only use needles which are specifically designed for use with a needle scaler. 9 Wear approved safety eye/face shield, ear defenders, and hand protection. 9 Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes. 9 Keep children and non essential persons away from the working area. 8 DO NOT use the needle scaler for a task it is not designed to perform. WARNING! DO NOT use needle scaler if damaged or thought to be faulty. (Contact Sealey service agent). 8 DO NOT use needle scaler unless you have been instructed in its use by a qualified person. 8 DO NOT carry the needle scaler by the air hose, or yank the hose from the air supply. 8 DO NOT operate needle scaler if you are tired or under the influence of alcohol, drugs or intoxicating medication. 8 DO NOT carry needle scaler with your hand on the power trigger in order to avoid unintentional starting. 8 DO NOT direct air from the air hose at yourself or others. 9 When not in use disconnect from air supply and store in a safe, dry, childproof location.

2. INTRODUCTION Suitable for cleaning heavy paint and rust scale from metal surfaces. Composite housing protects user from chill and helps to reduce vibration. Palm control trigger mechanism. Directional, low noise air exhaust can be rotated 360, giving operator added protection. Replacement needle set available.

3. SPECIFICATION Model No .................................................................... SA661 Air Consumption:............................................................ 6cfm Free Speed: ............................................................ 4600bpm Inlet Size: .................................................................1/4BSP Nett Weight: ................................................................. 1.3kg Noise Power/Pressure: ...................................... 92/90dB(A) Operating Pressure: ...................................................... 90psi Stroke .......................................................................... 38mm Vibration/Uncertainty: ........................................ 4.9/2.45m/s Consumable Parts: (Sold Separately) SA51/16 - Replacement Needle Set (12pc)

4. ASSEMBLY 4.1. Screw the scaling head fully onto the body as indicated in (fig.1). 4.2. AIR SUPPLY

WARNING! Ensure the air supply is clean and does not exceed 90psi while operating the needle scaler. Too high an air pressure and unclean air will shorten the product life due to excessive wear, and may be dangerous causing damage and/or personal injury.

4.2.1. Ensure needle scaler trigger is not depressed before connecting to the air supply. 4.2.2. You will require an air pressure of 90psi, and a minimum air flow of 6cfm. 4.2.3. Drain the air tank daily. Water in the air line will damage the needle scaler. 4.2.4. Clean air inlet filter weekly. Recommended hook-up procedure is shown in (fig.2). 4.2.5. Line pressure should be increased to compensate for unusually long air hoses (over 8 metres). The minimum hose diameter should be

1/4 internal diameter and fittings must have compatible dimensions. 4.2.6. Keep hose away from heat, oil and sharp edges. Check hose for wear, and make certain that all connections are secure.

fig.1

Refer to instructions

Wear eye protection

Wear protective gloves

Wear ear protection

Wear protective clothing

Wear a mask

4.3. COUPLINGS Vibration may cause failure if a quick change coupling is connected directly to the needle scaler. To overcome this, connect a leader hose to the needle scaler (Sealey ref: AH2R or AH2R/38). A quick change coupling may then be used to connect the leader hose to the air line recoil hose (fig.2 & fig.3).

5. OPERATION WARNING! Ensure you read, understand and apply Section 1 safety instructions.

5.1. Connect the needle scaler to the air supply as described in Section 3. 5.2. To start the scaler, depress the trigger.

8 DO NOT allow the needle scaler to free run for an extended period of time as this will shorten its life.

6. MAINTENANCE NOTE: Numbers in brackets refer to the parts list and diagram.

WARNING! Disconnect needle scaler from air supply before servicing or performing maintenance. Replace or repair damaged parts.

Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty. Numbers refer to attached Parts List. 6.1. To replace the needles, unscrew the body from the scaling head (refer fig.1). 6.2. Unscrew the Front Cover (23) from the Body (17) and remove the old Needles (19) and Needle Holder (20). Remove the old

needles from the needle holder and replace them with a new set of needles. Reassemble the scaling head in the reverse order of that described above. Screw the reassembled scaling head back onto the pistol body.

6.3. Lubricate the needle scaler daily with a few drops of Sealey air tool oil dripped into the air inlet. 6.4. Clean the needle scaler after use. 6.5. Loss of power or erratic action may be due to the following: 6.6. a) Excessive drain on the air line. Moisture or restriction in the air pipe. Incorrect size or type of hose connectors. To remedy check

the air supply and follow instructions in Section 3. 6.7. b) Grit or gum deposits in the needle scaler may also reduce performance. Flush the needle scaler out with gum solvent oil or an

equal mixture of SAE10 oil and paraffin. Allow to dry before use. 6.8. For a full service contact your local Sealey service agent. 6.9. When not in use, disconnect from air supply, clean needle scaler and store in a safe, dry, childproof location.

WARNING! Risk of Hand Arm Vibration Injury. This tool may cause Hand Arm Vibration Syndrome if its use is not managed adequately. This tool is subject to the vibration testing section of the Machinery Directive 2006/42/EC. This tool is to be operated in accordance with these instructions. Measured vibration emission value (a): 4.9m/s Uncertainty value (k):2.45m/s Please note that the application of the tool to a sole specialist task may produce a different average vibration emission. We recommend that a specific evaluation of the vibration emission is conducted prior to commencing with a specialist task. A health and safety assessment by the user (or employer) will need to be carried out to determine the suitable duration of use for each tool. NB: Stated Vibration Emission values are type-test values and are intended to be typical. Whilst in use, the actual value will vary considerably from and depend on many factors. Such factors include; the operator, the task and the inserted tool or consumable. NB: ensure that the length of leader hoses is sufficient to allow unrestricted use, as this also helps to reduce vibration. The state of maintenance of the tool itself is also an important factor, a poorly maintained tool will also increase the risk of Hand Arm Vibration Syndrome. Health surveillance. We recommend a programme of health surveillance to detect early symptoms of vibration injury so that management procedures can be modified accordingly. Personal protective equipment. We are not aware of any personal protective equipment (PPE) that provides protection against vibration injury that may result from the uncontrolled use of this tool. We recommend a sufficient supply of clothing (including gloves) to enable the operator to remain warm and dry and maintain good blood circulation in fingers etc. Please note that the most effective protection is prevention, please refer to the Correct Use and Maintenance section in these instructions. Guidance relating to the management of hand arm vibration can be found on the HSE website www.hse.gov.uk - Hand-Arm Vibration at Work

Original Language Version Jack Sealey Limited

fig.2 fig.3

SA661 Issue 4 01/07/20

Original Language Version Jack Sealey Limited

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk

ENVIRONMENT PROTECTION Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids according to local regulations.

Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice. Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.

EC DECLARATION OF CONFORMITY

Description and Function:

Model/Type:

Manufacturing Date/Serial Number where applicable:

This declaration of conformity is issued under the sole responsibility of the manufacturer:

Jack Sealey Ltd, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR

Declaration of Conformity in accordance with the above Directive(s)

Technical file compiled by: Jack Sealey Ltd

Being the responsible person appointed by the manufacturer.

Signed

Date

Name

Position

Place: Bury St Edmunds

Air Needle Scaler Composite

SA661 v1

2006/42/EC Machinery Directive

References to harmonised standard(s)

EN ISO 11148-4:2010

EN ISO 15744:2008

26 April 2019

Steve Buckle

Marketing Director

XVII2813

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.u

Manualsnet FAQs

If you want to find out how the SA661 Sealey works, you can view and download the Sealey SA661 Needle Scaler Instruction Manual on the Manualsnet website.

Yes, we have the Instruction Manual for Sealey SA661 as well as other Sealey manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Instruction Manual should include all the details that are needed to use a Sealey SA661. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Sealey SA661 Needle Scaler Instruction Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Sealey SA661 Needle Scaler Instruction Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Sealey SA661 Needle Scaler Instruction Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Sealey SA661 Needle Scaler Instruction Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Sealey SA661 Needle Scaler Instruction Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.