0-12.7MM(0-0.5) DIGITAL EXTERNAL MICROMETER MODEL NO: AK9638D

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1. SAFETY WARNING! Ensure Health and Safety, local authority and general workshop practice regulations are adhered to when using tools and

equipment. 8 DO NOT use micrometer if damaged. 9 Maintain micrometer in good and clean condition for best and safest performance. 9 Keep the work area clean, uncluttered and ensure there is adequate lighting. 9 Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes. 9 Keep children and unauthorised persons away from the work area. 8 DO NOT use the micrometer for any purpose other than for which it is designed. 8 DO NOT get micrometer wet or use in damp or wet locations, or areas where there is condensation. Keep micrometer clean and dry using

a dry cotton cloth only. 8 DO NOT dip or submerge the micrometer in any type of liquid. 8 DO NOT expose calliper to bright sunlight or dust. 8 DO NOT dis-assemble micrometer. The micrometer must be checked by qualified service personnel only. 8 DO NOT apply any voltage to the micrometer i.e. with an electric marker pen. 9 The micrometer is a precision instrument, treat with care, avoid using force and do not subject to knocks or shocks. 9 Take particular care not to damage or scratch the scale surface. 9 Use micrometer in reasonably constant temperature conditions of approximately 20C.

2. INTRODUCTION Digital micrometer with spring loaded satin chrome pin. Easy-to-read LCD digital display with auto off feature. Zero display in any position for relative and tolerance readings. Display switchable between Metric and Imperial units.

3. SPECIFICATION

Model No: ................................... AK9638D Accuracy: ..........................0.03mm(0.001) Battery: .........................1 x LR44 (supplied) Graduation: .......................0.01mm(0.0005) Range: ............................ 0-12.7mm(0-0.5)

4. OPERATION WARNING! Ensure that you have read and understood Section 1 safety instructions before commencing.

4.1. Ensure all measuring surfaces are clean and then turn on micrometer by pressing on/off control. Wait at least one second before use. 4.2. If read-out does not show zero when micrometer is in closed position, reset by pressing zero control. 4.3. Select inch or mm units, as required, with the metric/imperial selector. Check that display shows the required units. 4.4. Retract the measuring pin by pressing the red lever above the display. Introduce the object to be measured into the measuring space and allow

the pin to close onto the object so that it is between the end of the pin and the measuring pad. 4.5. Measurements will now be shown directly on the LCD display. 4.6. A new zero may be obtained, at any open position for relative and tolerance readings, by pressing the zero control.

AK9638D Issue 3 (4) 02/07/2020Original Language Version Jack Sealey Limited

Refer to instructions

fig.1

1 Measuring Pad 5 Measuring lever 9 Battery Cover 2 Measuring Space 6 LCD Display 3 Measuring Pin 7 On/Off Control 4 Metric/Imperial Selector 8 Zero Button

5. BATTERY FITTING A flashing display indicates that the battery is exhausted - replace as follows:

5.1. Switch off and then remove battery cover by firmly sliding downwards. When the two tags are exposed, lift off the battery cover as shown in fig.2A.

5.2. Remove exhausted battery and fit replacement with positive side uppermost (fig.2B). 5.3. Refit the battery cover by placing it over the battery in the position shown in fig.2A. Press lightly on the cover and push up to close the

compartment. 5.4. Dispose of old battery in a safe and approved manner. Do not burn. 5.5. If the display fails to alter when the slide is moved, remove the battery - wait at least 30 seconds and then refit the battery.

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk

ENVIRONMENT PROTECTION Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids according to local regulations.

WEEE REGULATIONS Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid waste authority for recycling information.

BATTERY REMOVAL SEE SECTION 5 Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products containing batteries (as defined within these regulations), that they are registered with Valpaks registered compliance scheme. Jack Sealey Ltd Batteries Producer Registration Number (BPRN) is BPRN00705.

Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice. Important: No Liability is accepted for incorrect use of this product. Warr

Manualsnet FAQs

If you want to find out how the AK9638D Sealey works, you can view and download the Sealey AK9638D Micrometer Instruction Manual on the Manualsnet website.

Yes, we have the Instruction Manual for Sealey AK9638D as well as other Sealey manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Instruction Manual should include all the details that are needed to use a Sealey AK9638D. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Sealey AK9638D Micrometer Instruction Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Sealey AK9638D Micrometer Instruction Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Sealey AK9638D Micrometer Instruction Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Sealey AK9638D Micrometer Instruction Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Sealey AK9638D Micrometer Instruction Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.