0-25MM(0-1) DIGITAL EXTERNAL MICROMETER MODEL NO: AK9635D.V3

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1. SAFETY WARNING! Ensure Health and Safety, local authority and general workshop practice regulations are adhered to when using tools and

equipment. 8 DO NOT use the micrometer if damaged. 9 Maintain the micrometer in good and clean condition for best and safest performance. 9 Keep the work area clean, uncluttered and ensure there is adequate lighting. 9 Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes. 9 Remove ill fitting clothing. Remove ties, watches, rings and other loose jewellery. Contain or tie back long hair. 8 DO NOT use the micrometer for any purpose other than for which it is designed. 8 DO NOT get micrometer wet or use in damp or wet locations, or areas where there is condensation. Keep micrometer clean using a dry

cotton cloth only. 8 DO NOT dip or submerge the micrometer in any type of liquid. 8 DO NOT expose micrometer to bright sunlight or dust. 8 DO NOT dis-assemble micrometer. The device must be checked by qualified service personnel only. 8 DO NOT apply any voltage to the micrometer i.e. with an electric marker pen. 9 The micrometer is a precision instrument, treat with care, avoid using force and do not subject to knocks or shocks. 9 Take particular care not to damage or scratch the scale surface. 9 Use micrometer in reasonably constant temperature conditions of approximately 20C. 9 When not in use, store micrometer in a safe, dry, childproof location. 9 Keep children and unauthorised persons away from the work area.

2. INTRODUCTION Seven button digital micrometer with satin chrome thimble and sleeve. Large, easy-to-read 9mm high LCD read-out. Display switchable between metric and imperial units. Zero display in any position for relative and tolerance readings. Auto power off. Supplied with adjustment wrench and storage case.

3. SPECIFICATION Model no: ........................................................... AK9635D.V3 Range: ................................................................0-25mm (0-1) Graduation: ...............................................0.001mm (0.00005) Battery: ............................................................ LR44 (supplied) Accuracy: .................................................. 0.002mm (0.0001)

4. OPERATION WARNING! Ensure that you have read and understood

Section 1 safety instructions before commencing. 4.1. Ensure all measuring surfaces are clean. 4.2. ORIGIN SETTING. Use this function to preset the origin

value. (Value can be anything from 0-25mm and can be used for calibration purposes). 4.2.1. Press (RESET) and (-) buttons together and hold until SET begins to flash on the LCD. 4.2.2. Press the (+) or (-) button to preset the origin value as

required. Now press (RESET) to confirm the setting. 4.3. ORIGIN RESETTING. Use this function to calibrate the

device using the preset origin value entered in step 4.2. 4.3.1. Ensure the measuring faces of the micrometer are in contact with the object being used to calibrate it and that the measurement is

precisely the distance required (i.e. identical to the preset origin value) and press (RESET). 4.4. To measure an object: open the micrometer by revolving the large barrel, place the object between the measuring surfaces and close the

micrometer using the smaller ratchet barrel (the ratchet is used to prevent over tightening which could other wise result in inaccurate measurement, damage to the micrometer and damage to the object being measured). The reading is taken from the LCD display.

Refer to instructions

1. Metric/Imperial conversion 2. Data hold 3. Relative/absolute measuring 4. Tolerance setting 5. Positive setting 6. Negative setting 7. Reset

AK9635D.V3 Issue: 2 (4) 02/07/2020Original Language Version Jack Sealey Limited

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk

ENVIRONMENT PROTECTION Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids according to local regulations.

Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice. Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.

WEEE REGULATIONS Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid waste authority for recycling information.

BATTERY REMOVAL REFER TO SECTION 5.2 Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products containing batteries (as defined within these regulations), that they are registered with Valpaks registered compliance scheme. Jack Sealey Ltd Batteries Producer Registration Number (BPRN) is BPRN00705.

4.5. METRIC/IMPERIAL CONVERSION. Press the in/mm button (1) to convert the display format from inches to millimetres and visa versa.

4.6. DATA HOLD. This function is used to temporarily hold or fix data on the LCD display for ease of recording. 4.6.1. Once a measurement has been taken, press the HOLD button (2). The letter H will appear at the top of the display and the data

currently shown will become fixed. When the data has been recorded, press the HOLD button again to release the display. 4.7. RELATIVE/ABSOLUTE MEASURING. To use relative measuring e.g. to determine the difference in width of two objects, measure

the first object (as explained in section 3.4), press the R/A button (the letters REL should appear in the LCD) and immediately measure the second object. The LCD will display the difference between the two objects. To revert back to absolute measuring simply press the R/A button once more.

4.8. TOLERANCE SETTING. Use to set a tolerance e.g. for use when measuring a large number of components to check they are within acceptable size limits.

4.8.1. Press the TOL button. TOL up should appear in the LCD. Turn the micrometer to set the upper level. 4.8.2. Press the TOL button again, TOL down should now appear in the LCD. Turn the micrometer once more to set the lower level. Press

the TOL button again to confirm the settings, OK should appear in the LCD. 4.8.3. To wipe the tolerance setting, press the TOL button three times in quick succession.

5. MAINTENANCE 5.1. If the micrometer is not to be used for an extended period of time, remove the battery for storage. NOTE: The LCD will flash continuously if the battery is run down. 5.2. To remove/change the battery: Using the semi circular back of the adjustment wrench provided and unscrew the battery compartment

lid located on the back of the micrometer. Remove/replace battery (anode (+) facing outward) and screw the lid back on. 5.3. After prolonged service, the reading point may become slightly loose and misaligned. This can be corrected using the wrench

provided. Fully close the micrometer. Place the wrench as shown in Fig 2 i.e. with the small protrusion hooking the hole at Point A. Using the wrench, alter the position of the reading point until it is once more aligned with the 0 on the barrel scale.

5.4. The

Manualsnet FAQs

If you want to find out how the AK9635D.V3 Sealey works, you can view and download the Sealey AK9635D.V3 Micrometer Instruction Manual on the Manualsnet website.

Yes, we have the Instruction Manual for Sealey AK9635D.V3 as well as other Sealey manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Instruction Manual should include all the details that are needed to use a Sealey AK9635D.V3. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Sealey AK9635D.V3 Micrometer Instruction Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Sealey AK9635D.V3 Micrometer Instruction Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Sealey AK9635D.V3 Micrometer Instruction Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Sealey AK9635D.V3 Micrometer Instruction Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Sealey AK9635D.V3 Micrometer Instruction Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.