Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1. SAFETY

WARNING! Ensure Health & Safety, local authority and general workshop practice regulations are adhered to when using this equipment. 9 Familiarise yourself with product application and limitations, as well as the specific hazards peculiar to the pump. WARNING! Disconnect the hydraulic pump from the apparatus before servicing or performing any maintenance. 9 maintain pump in good order. Replace/repair with genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty. 9 Use qualified person to lubricate and maintain the hydraulic pump. DO NOT use brake fluid to top up hydraulic unit. Use Sealey hydraulic oil

only. 9 Keep the pump and treadle clean for best and safest performance. WARNING! Ensure you know how much load you are pushing. Never exceed the maximum pushing capacity. 9 The kit accessories may be used with other popular makes of kit. 9 We recommend the use of BS approved safety impact goggles and heavy duty gloves when working with this pump. Both are available from

your authorised Sealey stockist. 9 maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes. 9 If working on an off centre load, pump with care. If you feel undue resistance, stop and re-adjust the set-up. 9 Ensure any hydraulic hoses are not bent or kinked but laid out correctly. Avoid damage to hoses (e.g. crushing/cutting). 9 Keep non-essential persons away from the operating area. Be aware of the locations of other persons assisting you. 8 DO NOT operate the pump if any parts are damaged or missing as this may cause failure and/or personal injury. WARNING! DO NOT use for any purpose other than for which it is designed. 9 When not in use, place dust cap in end of hydraulic hose or cylinder and store in a safe, dry, childproof location.

2. INTRODUCTION Suitable for use with SuperSnap hydraulic ram as supplied with model no. DZRE92/C Body Straightener and all body kits. Supplied without air hose. (Also available with hose - Order model No. RE83/840/CWH.S

3. SPECIFICATION model no. .......................... RE83/840.V2/RE83/840/CWH.V2 max. air input ......................................................... 90-120psi Oil capacity .................................................................. 450cc Oil pressure ..............................................................10000psi

4. OPERATION 4.1. SETTING UP 4.1.1. Remove pipe plug from hydraulic adaptor and connect a hose (model RE83/840.V2 only) 4.1.2. Remove the shipping plug from the air inlet port and insert a 1/4NPTquickreleasecoupler(Ifnotfitted). 4.1.3. Connect an air supply to the quick release air hose coupler and connect the hydraulic hose to the ram or device coupler. 4.1.4. To operate the pump for ram/device extension/actuation, depress the treadle at the air inlet valve end. 4.1.5. To retract the ram/device to the original start position, depress treadle end marked RELEASE. Retraction will stop with load held, when pressure on treadle is removed. For fullest retraction continue to depress.

Refer to instruction

manual

Wear eye protection

Wear protective gloves

Original Language Version Jack Sealey Limited

Only fully trained and qualified persons should use this equipment. These instructions are not a substitute for user receiving full supervised training by a qualified person. It is important the user understands the applications, limitations and potential hazards of the product.

mODEL: RE83/840.V2

mODEL: RE83/840/CWH.V2

RE83/840.V2, RE83/840/CWH.V2 | Issue:3 (H,F) 25/06/19

Original Language Version Jack Sealey Limited

4.2. OPERATING REQUIREMENTS 4.2.1. For maximum performance and rated hydraulic pressure, air pressure should be 100psi minimum. 4.2.2. Toensurebestperformancetheairsupplyequipmentshouldincludeanairfilter,regulatorandlubricator.Aminimum requirementisanairfilterwiththeaircompressortankdrainedofwatereverydayandasmallquantityoflubricatingoilintotheair inlet each week. 4.2.3. Hydraulic output pressure can be controlled by regulating the air pressure. To determine the maximum hydraulic pressure multiply the

regulated air pressure reading by 100.

5. MAINTENANCE 5.1. RELEASE VALVE ADjUSTMENT 5.1.1. Attach an air supply to the pump. 5.1.2. With a hex key loosen socket headed cap screw (Fig.2.) in treadle pivot boss two or three full turns. 5.1.3. With a screwdriver turn anti-clockwise the slotted head release valve (Fig.2. and Fig.3.) two full turns. 5.1.4. Lift the treadle at the air inlet end and depress the air valve button (Fig.1.) with your thumb. 5.1.5. Actuate the pump to build up pressure in the hose by depressing the treadle on to thumb and depressed air valve. 5.1.6. Using a screwdriver turn the slotted head release valve clockwise gently until resistance of the valve seat is felt. Excessive tightening

will cause loss of pressure in hose. 5.1.7. Continuing to depress the air valve button with your thumb to obtain operating clearance between the treadle air valve and the release

valve, tighten socket headed cap screw with a hex key through treadle pivot boss. 5.1.8. Release valve should now be correctly set.

IMPORTANT: NO RESPONSIBILITY IS ACCEPTED FOR INCORRECT USE. Hydraulic products are only repaired by local service agents. We have service/repair agents in all parts of the UK. DO NOT RETURN PRODUCT TO US. Please telephone us on 01284 757500 to obtain the address and phone number of your local agent. If product is under guarantee please contact your dealer. De-commissioning Product Should the product become completely unserviceable and require disposal, draw off the oil into an approved container and dispose of the product and the oil according to local regulations.

.

RE83/840.V2, RE83/840/CWH.V2 | Issue:3 (H,F) 25/06/19

Oilfillerplug(onunderside)

Release valve

Air valve button

Socket head cap screw

fig.1

fig.2

fig.3

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk

ENVIRONMENT PROTECTION Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids according to local regulations.

Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice. Please note that other versions of this product are available

Manualsnet FAQs

If you want to find out how the RE83-840.V2 Sealey works, you can view and download the Sealey RE83-840.V2 Hydraulic Pump Instruction Manual on the Manualsnet website.

Yes, we have the Instruction Manual for Sealey RE83-840.V2 as well as other Sealey manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Instruction Manual should include all the details that are needed to use a Sealey RE83-840.V2. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Sealey RE83-840.V2 Hydraulic Pump Instruction Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Sealey RE83-840.V2 Hydraulic Pump Instruction Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Sealey RE83-840.V2 Hydraulic Pump Instruction Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Sealey RE83-840.V2 Hydraulic Pump Instruction Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Sealey RE83-840.V2 Hydraulic Pump Instruction Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.