Sealey 9361 Filter Cartridge Instruction Manual PDF

1 of 3
1 of 3

Summary of Content for Sealey 9361 Filter Cartridge Instruction Manual PDF

WORKSAFE HALF MASK RESPIRATORS AND FILTER CARTRIDGES MODEL NOS: 9360, 9360/61, 9360/62, 9360/63, 9360/66

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1. SAFETY WARNING! Ensure all Health and Safety, local authority, and general workshop practice regulations are strictly adhered to when

using this product. IMPORTANT! NOT FOR USE WITH TOXIC PAINTS SUCH AS ISOCYANATE. WARNING! DO NOT use in an oxygen deficient atmosphere (below 19% by volume). WARNING! DO NOT use in an oxygen enriched atmosphere (above 25% by volume). 9 Respirator selection must be undertaken by a competent person who is aware of the intended conditions of use. Only fit the

respirator under the supervision of a competent person. 9 If in doubt as to suitability of the equipment for the work to be undertaken, consult your supplier. 9 Before use, check that the mask is clean and in good condition. If you detect deterioration of valve diaphragms, or other rubber

components, replace immediately. 9 Check that the correct cartridge is fitted to suit the hazard and that all components are correctly assembled and in a clean condition. 9 Change the main filter cartridge frequently. The effective life of a main filter should be determined by a competent person who is

aware of the conditions of use. 9 Ensure you use recommended parts only, unauthorised parts may be dangerous and will invalidate any warranty. 9 Only when worn correctly fitted will the mask provide the prescribed degree of protection. 9 Ensure the face-piece fits comfortably on the face. WARNING! Mask may not fit correctly if facial hair passes under the face-seal. 9 Upon leaving the contaminated area, remove excess contamination from clothes before removing the respirator. 9 After each working period, the respirator must be cleaned and prepared for the next period of use. 8 DO NOT use detergents, thinners, solvents or petroleum-based disinfectant to clean the respirator. Clean the unit with warm soapy

water only. 8 DO NOT allow water to get into the main filter. 9 Care must be taken to ensure the rubber seal on the inside of the filter holder is not damaged. 9 Ensure you keep records of respirator maintenance. 9 When not in use, store the cleaned respirator in a sealed plastic bag in a clean, dry atmosphere out of direct sunlight and out of the

reach of children. Keep unit away from chemicals, abrasive substances and such that it cannot be damaged by physical contact with hard surfaces/items.

2. INTRODUCTION Lightweight and dermatologically friendly made from soft thermoplastic elastomer. Built-in exhalation vent makes breathing out easy and comfortable without letting harmful materials in. Threaded cartridges makes connecting filters easy and efficient. Adjustable straps in order to optimize comfort and support. S

3. SPECIFICATION MODEL NO: 9360......(Half Mask - No Cartridges) MODEL NO: 9360/61 (Half Mask with A1P2R Filter Cartridges) MODEL NO: 9360/62 (Half Mask with P3R Filter Cartridges) MODEL NO: 9360/63 (Half Mask with ABEK1 P2R Filter Cartridges) MODEL NO: 9360/66 (Half Mask with A2P3R Filter Cartridges) FILTER OPTIONS:

9360, 9360/61, 9360/62, 9360/63, 9360/66 Issue 1 06/09/21Original Language Version Jack Sealey Limited

Refer to instructions

Humidity to be less that 80%

Store between -5oC and 50oC

FILTER PART NUMBER

RATING PROTECTION MAXIMUM USER LEVELS

Qty.

9361 A1 P2R Organic Vapour and Particulate Pre-Filter

1000 ppm or 10 x OEL whichever is lower

2

9362 P3R Particle Filter 30 x OEL 2

9363 ABEK1 P2R OV/IO/AG/AM and Particulate Pre-filter

1000 ppm or 10 x OEL whichever is lower

2

9366 A2 P3R Organic Vapour and Particulate

5000 ppm or 30 x OEL whichever is lower

2

SPARES: 9364: Pre-filter for 9361 & 9363 (Pack of 10). 9365: Pre-filter fixing ring for 9361 & 9363 (Pack of 2).

4. OPERATION 4.1. CHANGING THE FILTER NOTE: If you unscrew and remove either of the filters and put them back on, check the seal has not been damaged. 4.2. DURING USE. 4.2.1. In the interest of safety, change the filter frequently. 4.2.2. The effective life of the filter should be determined by a

competent person who is aware of the conditions of use. 4.2.3. Upon leaving the contaminated area, remove excess

contamination from clothes before removing the respirator. 4.3. ASSEMBLY AND FITTING 4.3.1. Screw filter body into the face-mask housing (fig.2). 4.3.2. Fit Pre-filter (9361 / 9363) and Pre-filter fixing Ring (9365) to filter body (fig.3). 4.3.3. Place head straps over the back of the head and above the ears (fig.4). 4.3.4. Fasten the elastic strap on the back of the neck (fig.5). 4.3.5. Pull the ends of the elastic strap evenly until the face mask fits tightly against the users face (fig.6). 4.3.6. When not in use, store the unit in accordance with instructions section 5.3 (fig.7).

5. MAINTENANCE NOTE: All components have a shelf life of 5 years from date of purchase. 5.1. The lifetime of a filter depends on many factors including the work rate, the airflow and the concentration of the contaminant in the

atmosphere. A gas filter should be changed immediately when chemical breakthrough of a contaminant is detected by smell, taste or any other means. A dust filter should be changed when breathing becomes impaired. The exterior of the filter can be cleaned with the use of a damp cloth. Solvents must not be used and care should be taken to ensure no water enters the filter. Cleaning of the filter does not extend its life.

5.2. CLEANING THE RESPIRATOR. After each work period (shift, or working day, etc.) the respirator must be cleaned and prepared for the next period of use. When the filter is being replaced it is a good opportunity to disassemble the respirator and thoroughly clean it. No special tools are required to remove any of the components from the face-piece. 5.2.1. The outer surfaces of the respirator may be cleaned using a cloth dampened with warm soapy water, then dried using a dry cloth. 5.2.2. DO NOT ALLOW WATER TO GET INTO THE FILTER. 5.2.3. Clean the respirator components using warm soapy water.

8 DO NOT USE DETERGENTS, THINNERS, SOLVENTS OR PETROLEUM-BASED DISINFECTANTS. TAKE GREAT CARE NOT TO DAMAGE THE RUBBER SEAL ON THE INSIDE OF THE FILTER HOLDER WHILST CLEANING.

5.2.4. Inhalation and exhalation valves must be cleaned carefully. DO NOT stretch or distort the valves as this may cause incorrect sealing. Wipe the inside surface of the mask using a mild antiseptic solution, and dry with a clean cloth.

IF ANY DETERIORATION OF COMPONENTS IS VISIBLE, REPLACE IMMEDIATELY. 5.2.5. Rinse in clean, cool water, shake off any surplus water, wipe with a clean dry cloth and allow to dry naturally. 5.2.6. Once the components are clean and dry, re-assemble the respirator in correct order. 5.2.7. Fit the correct new filter (see Section 3).

fig.2 fig.3 fig.4

fig.5 fig.6 fig.7

fig.1

Original Language Version Jack Sealey Limited 9360, 9360/61, 9360/62, 9360/63, 9360/66 Issue 1 06/09/21

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk

ENVIRONMENT PROTECTION Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids according to local regulations.

Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice. Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.

5.3. STORAGE 5.3.1. When not in use or during transportation, this filter should be stored in a sealed container such that it is out of direct sunlight, away

from chemicals, abrasive substances and cannot be damaged by physical contact with hard surfaces/items. 5.3.2. Filters should be stored in a dry, cool environment away from direct sunlight and contamination. NOTE: Humidity value of storage area to be less than 80%. NOTE: Storage area temperature to be between -5oC to 50oC. 5.4. MATERIALS

Part Material Face Seal Thermoplastic Elastomer (TPE) / Silicon

Head Harness Polyethylene

Head Strap Polyester / Cotton / Polyisoprene

Inhalation Valve Silicon Rubber

Exhalation Valve Silicon Rubber

Original Language Version Jack Sea

Manualsnet FAQs

If you want to find out how the 9361 Sealey works, you can view and download the Sealey 9361 Filter Cartridge Instruction Manual on the Manualsnet website.

Yes, we have the Instruction Manual for Sealey 9361 as well as other Sealey manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Instruction Manual should include all the details that are needed to use a Sealey 9361. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Sealey 9361 Filter Cartridge Instruction Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Sealey 9361 Filter Cartridge Instruction Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Sealey 9361 Filter Cartridge Instruction Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Sealey 9361 Filter Cartridge Instruction Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Sealey 9361 Filter Cartridge Instruction Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.