75L PUMP AWAY MOBILE OIL DRAINER MODEL NO: AK450DX

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1. SAFETY

WARNING! Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this equipment.

WARNING! DO NOT pollute the environment by allowing uncontrolled discharge of waste oil. Replace damaged parts. Use genuine parts only. Non authorised parts may be dangerous and will invalidate the warranty.

9 Keep the drainer clean and in good condition for best and safest performance. 9 Wear appropriate protective clothing. 9 Use drainer in an appropriate working area for its function. Keep area clean and tidy and free from unrelated materials and ensure 9 there is adequate lighting. 9 Ensure the floor is not slippery and wear non slip shoes. 9 Keep children and unauthorised persons away from the working area. 9 Dispose of waste liquids in accordance with local authority regulations. WARNING! DO NOT allow uncontrolled discharge of fluids thus polluting the environment. 8 DO NOT position drainer in such a way that it will cause potential hazards when moving, holding for draining or storing.

IMPORTANT: AK450DX must be used in conjunction with a wall mounted air pump, model no: AK450DP in order to discharge waste oil (not supplied with this unit).

2. INTRODUCTION 75L Reservoir and telescopic funnel fitted with grid filter. Fitted with female dry-fit coupling for connection to Model No. AK450DP Pump-Away Station. Includes full drum indicator.

3. SPECIFICATION Model No ............................................................... AK450DX Capacity ........................................................................... 75L Collection bowl capacity ................................................... 18L Gravity discharge ............................................................... no Gravity feed ..................................................................... yes Max. height to pan ................................................... 1620mm Min. height to pan ...................................................... 890mm Oil discharge pressure (bar) .........................................0.5bar Pump discharge ................................................................. no Temperature range .......................................................<55C

4. ASSEMBLY 4.1. Unscrew the complete axle assembly from the transportation position. Use the nuts, bolts, and washers that are provided to fit the axle

assembly and position the castor wheels as illustrated in the parts diagram. 4.2. Screw the drainage tube (item 3) into the collection bowl (item 2). 4.3. Introduce the drainage tube through the height adjustment adaptor into the reservoir and tighten the scalloped hand wheel (item 4). 4.4. Place the filter into the collection bowl (item 2).

5. OPERATION 5.1. COLLECTION OF WASTE OIL 5.1.1. If unit has been used to drain a previous vehicle, check the oil level indicator float to ensure there is sufficient remaining capacity left before you use the unit. 5.1.2. Place the unit under the raised vehicle and adjust the collection bowl to the desired height and tighten the scalloped hand wheel of the adjustable height adaptor. 5.2. EVACUATION OF WASTE OIL FROM UNIT

WARNING! Ensure all waste is disposed of in accordance with local regulations. 5.2.1. Take the discharge hose of wall mounted pump unit AK450DP and connect the female coupling to the male coupling of the pan unit

and evacuate waste accordingly. 5.2.2.

Refer to instruction

manual

Wear eye protection

Wear protective

gloves

Original Language Version Jack Sealey Limited AK450DX | Issue:4 (3) 20/07/20

Original Language Version Jack Sealey Limited

6. MAINTENANCE 6.1. Keep the collection bowl and unit clean and ensure there are no blockages in the evacuation outlets. 6.2. Oil wheels if necessary 6.3. When not in use store the unit in a safe, dry, childproof area.

6.4. 6.5.

.

AK450DX | Issue:4 (3) 20/07/20

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk

ENVIRONMENT PROTECTION Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely unserviceable and requires disposal,

Manualsnet FAQs

If you want to find out how the AK450DX Sealey works, you can view and download the Sealey AK450DX Drainer Instruction Manual on the Manualsnet website.

Yes, we have the Instruction Manual for Sealey AK450DX as well as other Sealey manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Instruction Manual should include all the details that are needed to use a Sealey AK450DX. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Sealey AK450DX Drainer Instruction Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Sealey AK450DX Drainer Instruction Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Sealey AK450DX Drainer Instruction Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Sealey AK450DX Drainer Instruction Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Sealey AK450DX Drainer Instruction Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.