instructions for

combustion leak detector model no: Vs0062

thank you for purchasing a sealey product. manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1. saFetY WarninG! ensure that Health & safety, local Authority regulations and general workshop practice regulations are adhered to

when using tools. 8 do not use leak detector if damaged. 9 maintain leak detector to ensure that it is in an adequate condition for safe use and optimum performance. 8 do not attempt to start or move a vehicle whilst in gear. 9 Wear suitable clothing to avoid snagging. 8 do not wear jewellery. tie back long hair. 9 Account for all tools, parts and components being used. 8 do not leave tools in or near the engine. return tools to suitable storage after use. 9 When not in use, store in a safe dry and childproof place.

2. introduction diagnose blown gaskets, cracked blocks and cylinder heads easily and quickly. checks levels of co2 in cooling system and indicates its presence by test fluid colour change. use with cone adaptor or in conjunction with radiator caps from model nos Vs001,Vs0011,Vs0033 and Vs006. for test fluid refill order model no. Vs0061f.

3. contents

storage Bottle rubber Bulb

Acrylic test chamber co2 test liquid Vs0061f cone Adapter

Vs0062 | issue:1 05/05/16Original Language Version Jack sealey limited

refer to instruction

manual

Wear eye protection

Wear protective clothing

Wear protective

Gloves

4. operation 4.1. to carry out test 4.1.1. prepare a container and remove approximately 1/10 of the volume of coolant. (fig.1). 4.1.2. open the radiator cap (make sure the radiator is cool before opening). 4.1.3. Removecaptochamber2,halffillwithblueCO2 test liquid and replace cap. 4.1.4. install the rubber bulb, acrylic chamber and rubber cone adapter one after another. 4.1.5. Installtesterdeviceontoradiatorsfillerneck.(Fig.2) 4.1.6. start engine and pump the rubber bulb continually to draw the steam from radiator and check if test liquid colour changes. (fig.3) 4.1.7. Aftertesting,stopengineandremoveconeadapterfromradiatorsfillerneckcarefully.Refillradiatorandreplacecap. 4.1.8. pour the used test liquid into storage bottles and store each component in the carry case. test liquid can be used 3 to 5 times.

liquid liquid Blue Green/Yellow

4.2. to read colour 4.2.1. test liquid remains Blue (no co2 detected)------------------cylinder head/gasket in good condition. 4.2.2. test liquid turns Green (co2 detected) -----------------------cylinder head/gasket leaking. 4.2.3. test liquid turns Yellow (large amounts co2 detected)---cylinder head/gasket leaking. 4.2.4. note:- the lighting in some work areas may affect the colour of the test liquid.

5. maintenance 5.1. Keep parts of leak detector clean and stored in the case provided. ensure test kit is kept in a secure, dry storage area and out of

the reach of children.

Original Language Version Jack sealey limited Vs0062 | issue:1 05/05/16

Fig.1 Fig.2 Fig.3

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice. important: no liability is accepted for incorrect use of this product. WarrantY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

sole uK distributor, sealey Group.

Kempson Way, suffolk Business park,

Bury st. edmunds, suffolk.

ip32 7Ar

www.sealey.co.uk

sales@sealey.co.uk

01284 757500

01284 703534

Web

environmental protection recycle unwanted materials instead of disposing of them as waste. All

Manualsnet FAQs

If you want to find out how the VS0062 Sealey works, you can view and download the Sealey VS0062 Detector Instruction Manual on the Manualsnet website.

Yes, we have the Instruction Manual for Sealey VS0062 as well as other Sealey manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Instruction Manual should include all the details that are needed to use a Sealey VS0062. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Sealey VS0062 Detector Instruction Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Sealey VS0062 Detector Instruction Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Sealey VS0062 Detector Instruction Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Sealey VS0062 Detector Instruction Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Sealey VS0062 Detector Instruction Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.