Sealey SDH30 .V3 Dehumidifier Instruction Manual PDF

1 of 5
1 of 5

Summary of Content for Sealey SDH30 .V3 Dehumidifier Instruction Manual PDF

30L INDUSTRIAL DEHUMIDIFIER MODEL NO: SDH30.V3

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1. SAFETY 1.1. ELECTRICAL SAFETY

WARNING! It is the users responsibility to check the following: Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and all electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical products. You may obtain an RCD by contacting your local Sealey dealer. If the unit is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable Appliance Test) tested. Electrical safety information, it is important that the following information is read and understood.

1.1.1. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. 1.1.2. Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure. 1.1.3. IMPORTANT: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the

correct fuse - see fuse rating in these instructions. 8 DO NOT pull or carry the appliance by the power cable. 8 DO NOT pull the plug from the socket by the cable. 8 DO NOT use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or

replaced immediately by a qualified electrician. 1.1.4. This product is fitted with a BS1363/A 13 Amp 3 pin plug. If the cable or plug is damaged during use, switch the electricity supply and remove from use. Ensure that repairs are carried out by a qualified electrician. Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.

a) Connect the GREEN/YELLOW earth wire to the earth terminal E. b) Connect the BROWN live wire to the live terminal L. c) Connect the BLUE neutral wire to the neutral terminal N.

Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. Sealey recommend that repairs are carried out by a qualified electrician. 1.2. GENERAL SAFETY

9 Check that the dehumidifier is in sound condition and good working order. Take immediate action to repair or replace damaged parts. 9 Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty. 8 DO NOT stand or place any object less than 10cm from the front or rear of the unit. 8 DO NOT obstruct the air intakes or outlets of the dehumidifier. 8 DO NOT place any object into the outlets - the unit has a fan running at high speed, contact with this will cause injury. 8 DO NOT operate the dehumidifier when you are tired or under the influence of alcohol, drugs or intoxicating medication. 8 DO NOT switch the dehumidifier off by disconnecting it from the mains. ALWAYS switch to the OFF position first. 8 DO NOT remove the float lever from the water collection tank. 8 DO NOT connect or disconnect the plug from the mains with wet hands. 9 Always discard the water from the collection tank, DO NOT use it for any other purpose. 9 Place the dehumidifier on a level and stable surface. 8 DO NOT use the dehumidifier at ambient temperatures below 5C. 8 DO NOT use the dehumidifier outside. 9 When using continuous draining, make sure that the drain hose is positioned correctly. 9 Ensure that heating appliances are not exposed to the flow of air from the dehumidifier. 9 Before attempting to move the dehumidifier, empty the contents of the collection tank. 9 Switch off and disconnect it from the mains before attempting any cleaning or other maintenance work. 9 Ensure that the dehumidifier is correctly turned off when not in use, and stored in a safe, dry area, out of reach of children.

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience or knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

Original Language Version Jack Sealey Limited

Refer to instructions

Do not cover Indoor use only Caution: Risk of fire

Recommended fuse rating

13 Amp

SDH30.V3 Issue 2 (2) 16/05/22

2. INTRODUCTION Powerful dehumidification capacity, extracts up to 30 litres of water per day. Removes excess moisture from air, preventing build-up of mildew and mould. Features auto-defrost function, which activates if the room temperature falls too low. The unit has a 24hr timer function for delay starting and auto-shut-off. Washable air filter. Refrigerant is environmentally friendly R290. May be connected to a drain hose for continuous operation. Mounted on castors for manoeuvrability.

3. SPECIFICATION Model No.:............................................................ SDH30.V3 CO2 Equivalent: .......................................................... 0.0006t Condensate Tank: .............................. 7L (with Auto Shut-Off) Dehumidifying Capacity: ..................... 30L/day(300CRH80%) Electrical Plug Type: ................................................3-Pin BS Freezing Pressure(Max): ............................................2.5MPa Global Warming Potential (Rating) ....................................... 3 IP Rating: ........................................................................IP22 Maximum Airflow: .....................................................300m3/hr Power: ................. 420W (270C RH60%) 500W(300C RH80%) Refrigerant: ........................................................R290/0.12kg Steaming Pressure (Max): .........................................1.0MPa Supply: ...........................................................................230V Working space: ....................................................... 50-120m

Working Temperature: ................................................. 5-350C

4. ASSEMBLY 4.1. With unit tipped forward, fix axle (fig.1) to underside of unit with the four screws provided. 4.2. Slide wheels onto the axle and fix in place using the plain washer and locking nut provided. 4.3. Remove the screws from the handle hinge point, rotate the handle to the upright position and re-fit the screws to fix it in place. NOTE: Once upright, DO NOT use the unit for at least 2 hours. 4.4. WATER TANK USAGE 4.5. You may use the water tank in two ways. 4.5.1. DIRECT USE. When the water tank is full, the machine automatically shuts down and enters the standby state, the LED displays

the Full Water signal and the dehumidifier will alarm. When the water tank is emptied and put in place again, the dehumidifier can continue its performance.

4.6. CONTINUOUS DRAINING 4.6.1. If there is a place suitable for draining, continuous draining can be carried out. The continuous operation enables the dehumidfying

operation to continue uninterrupted. 4.6.2. Turn off the dehumidifier, disconnect the power plug and remove the water collection tank. 4.6.3. Remove the plug from the bottom right hand side of the tank (fig.2) and attach a suitable length hose. 4.6.4. It should have an inner diameter of 5/8 and secure with a hose clip. 4.6.5. Thread the hose through the hole in the bottom right hand side of the base of the unit, insert the tank ensuring the hose is not kinked. 4.6.6. Continue to use the dehumidifier as normal. NOTE: When using continuous drainage, the drainage pipe shall not be set higher than the water tank.

Original Language Version Jack Sealey Limited

fig.1

fig.2

Locknut & washer

SDH30.V3 Issue 2 (2) 16/05/22

Original Language Version Jack Sealey Limited

5. OPERATION

NOTE: Efficiency of the dehumidifier is influenced by the air outside the room. For operating efficiency, try to avoid opening and closing the windows and doors. For best performance, operate the dehumidifier within the usable operating temperature. 5.1. OPERATION 5.1.1. Plug the unit in to the mains socket, a beep will be heard when inserting the plug. 5.1.2. Press the ON/OFF switch and the operation light will illuminate, the humidity display will light to display the previous set humidity.

The initial setting for humidity is 60%, after 3 seconds the display will show the current humidity. 5.1.3. Press the humidity up or down buttons to adjust to the desired humidity required. If the required humidity is 3% below the current humidity the unit will start automatically, if the set humidity is 3% more than the current humidity the dehumidifier will automatically stop. 5.1.4. When setting the humidity to less than 30%, the unit will run continuously and the display will read CO. 5.1.5. To shut the dehumidifier down press the ON/OFF switch. NOTE: If the humidity setting is greater than the current humidity the unit will not run.

WARNING! The fan motor and compressor must run for at least 3 minutes while dehumidifying. 8 DO NOT start the dehumidifier immediately after shutting down, allow 3 minutes before restarting.

5.2. TIMER FUNCTION 5.2.1. To set Timer for power ON mode, with the unit in power OFF state, press the Timer button (fig.3.6). The Timer ON LED (fig.3.1) will

flicker and the current set time will be displayed. Use the Increase/ Decrease buttons (fig.1.10, fig.1.11) to set the required value to between 0 and 24 hours. After 10 seconds the selected value is set and the Timer ON led will flicker. 5.2.2. To set the Timer for power OFF mode, with the unit in power ON state, press the Timer button (fig.3.6). The Timer OFF LED (fig.3.1)

will flicker and the current set time will be displayed. Use the Increase/ Decrease buttons (fig.3.10, fig.3.11) to set the required value to between 0 and 24 hours. After 10 seconds the selected value is set and the Timer OFF led will flicker.

5.3. DEFROSTING 5.3.1. The defrosting device works automatically at an interval of approximately every 30 minutes for a duration of approximately 5 minutes

when the coil temperature is tested to be <= minus 1oC. The dehumidifying function will stop during the defrosting operation. DO NOT disconnect the plug or turn off the unit during the defrosting operation. The defrosting led light (fig.3.7) will light up. NOTE: This dehumidifier does not have a cooling function, it produces heat during the operation and room temperature will rise by 1C to 4C. The temperature gets higher while it is operated in a closet, or similar. Furthermore, room temperature will rise because doors and windows are closed and heat is produced from other appliances in the room and from sun radiation. 5.4. EMPTYING THE WATER COLLECTION TANK 5.4.1. During the dehumidifying operation, water is collected in the water collection tank. When the tank is full of water, the dehumidifier stops operating automatically and the warning buzzer beeps twice. The unit will not restart until water collection tank has been emptied. 5.4.2. Open the door and remove water collection tank from the dehumidifier by pulling it gently outwards by holding the sides of the tank. 5.4.3. Hold the tank by the handle and carry it carefully to an emptying point. 5.4.4. Remove the plug at the bottom of the tank and slowly empty the water out of the tank. 5.4.5. Replace the drain plug and refit the tank in the dehumidifier, making sure it is properly back in place as the unit will not restart if it is

not fitted correctly.

ITEM OPERATION

1 Timer Indicator

2 Temperature Indicator

3 Dehumidification Indicator

4 Humidity Indicator

5 ON/OFF Control

6 Time Set Control

7 Defrosting Indicator

8 Air Speed Indicator

9 Water Full Indicator

10 Increase Control

11 Decrease Control

1 2 3 4 5 6

7 8 9 10 11

BUTTON OPERATION INSTRUCTIONS ON/OFF (fig.1.5) Changes between Switch on and Switch off.

+ (fig.1.10) Adjust different set values in different states; 1. Increases the humidity value set (RH10% to 95%) 2. Increases the timing (hour) set (00 to 24)

- (fig.1.11) Adjust different set values in different states; 1. Decreases the humidity value set (RH10% to 95%) 2. Decreases the timing(hour) set (00 to 24)

Timer (fig.1.6) Short press the button to launch a cycle to off. Set on/off Timer and Exit

fig.3

SDH30.V3 Issue 2 (2) 16/05/22

Original Language Version Jack Sealey Limited

5.5. CONTINUOUS DRAINING 5.5.1. If there is a place suitable for draining, continuous draining can be carried out. The continuous operation enables the dehumidfying

operation to continue uninterrupted. See Section 4.6.

6. MAINTENANCE 6.1. CLEANING THE AIR FILTER 6.1.1. The dehumidifying capacity is lowered when the air cleaning filter becomes clogged. 6.1.2. Open the front door of the unit. 6.1.3. Lift up the filter element from the bottom and lift out of the holder. 6.1.4. To dislodge the dust from the filter, use a vacuum cleaner or tap it lightly. 6.1.5. If the filter is very dirty, wash it carefully in water with a neutral detergent, then rinse well with clean water and leave until dry. 6.1.6. To refit the air filter locate the top of the element into the locating bracket at the top of the door and then locate the lower section into

the lower bracket. 6.1.7. Close the door of the dehumidifier. 6.2. STORAGE 6.2.1. Unplug the unit, bundle the power cord, and hang the bundled cord at the back of the unit. 6.2.2. Remove the water collection tank and empty the water out of it. Remove the tank cover and wash the inside of the tank with clean

water. The tank may be scratched if it is scrubbed strongly with a brush. DO NOT remove the float lever from the tank. Wipe off the water on the outside of the tank with a cloth. Refit the tank cover onto the tank and replace the tank in position.

6.2.3. Clean the air filter (see 6.1). 6.2.4. When the unit is to be stored for a long time, wipe the dehumidifier over with a dry soft cloth. To remove dirt, wipe over with a very slightly dampened cloth (never use a wet cloth for cleaning the controls). To avoid deformation or cracking, do not use benzine, thinner or liquid cleaners. 6.2.5. When storing, place in a safe, dry, childproof location. Stand the unit upright and avoid exposure to direct sunlight.

7. TROUBLE SHOOTING

Faults Cause Analysis Solutions

Fails to turn on

Shown as no power

No power to the wall socket. Check the power supply.

Check the plug plugged in properly.

Plug the power supply in the socket.

Check the fuse is not blown. Replace the fuse.

Power Transformer is broken. Replace the transformer.

Shown as power on

Environmental humidity lower than the set value.

Set again according to the demand.

If the water tank is installed correctly.

Place the water tank in right position.

If the entire machine is defrosting. Wait for the completion of defrosting cycle.

Unfavourable dehumidifying effect

If the air inlet/outlet is obstructed. Remove the obstacle.

If the door and window are open. Close the door and window.

If the indoor temperature is too low. Dont run the dehumidifier.

Heavy noise If the ground is firm and flat. Resettle the dehumidifier.

Dehumidifier is stood precariously. Resettle the dehumidifier.

Water leakage Dehumidifier stood on an incline. Move dehumidifier to a level surface.

Drain pipe/outlet obstructed. Dismantle the front plate to eliminate blockages.

E1 Coil sensor fault Turn to timing for defrosting, to cancel system fault function.

E2/E3 Fault of humidity & temperature sensor. Replace the humidity & temperature sensor.

EE Refrigerant leakage. Attempt shut down and restart, if no change seek help from professionals if the EE signal remains.

SDH30.V3 Issue 2 (2) 16/05/22

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk

ENVIRONMENT PROTECTION Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids according to local regulations.

WEEE REGULATIONS Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid waste authority for recycling information.

Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call our technical team on technical@sealey.co.uk or 01284 757505. Important: No Li

Manualsnet FAQs

If you want to find out how the SDH30 .V3 Sealey works, you can view and download the Sealey SDH30 .V3 Dehumidifier Instruction Manual on the Manualsnet website.

Yes, we have the Instruction Manual for Sealey SDH30 .V3 as well as other Sealey manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Instruction Manual should include all the details that are needed to use a Sealey SDH30 .V3. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Sealey SDH30 .V3 Dehumidifier Instruction Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Sealey SDH30 .V3 Dehumidifier Instruction Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Sealey SDH30 .V3 Dehumidifier Instruction Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Sealey SDH30 .V3 Dehumidifier Instruction Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Sealey SDH30 .V3 Dehumidifier Instruction Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.