5. OPERATION 5.1. Coupling 5.1.1. . Ensure the air valve is in the off position before connecting to the air supply. 5.1.2. An air pressure of no more than 8bar (115psi) and an air volume of 10cfm will be required.
WARNING! Ensure the air supply does not exceed 8bar (115psi). Too high a pressure will shorten the product life and may be dangerous, causing damage and/or personal injury.
5.1.3. Drain the air supply tank daily. Water in the air line will damage the gun. 5.1.4. Clean the air inlet filter screen weekly. 5.1.5. For recommended hook-up, see fig.1. 5.1.6. Line pressure should be increased to compensate for unusually long air hoses (over 8 meters). The minimum hose diameter should
be 1/4 internal diameter and fittings must have compatible dimensions. 5.1.7. Keep hoses away from heat, oil and sharp edges. Check hoses for wear, and make certain that all connections are secure.
WARNING! Ensure you read, understand and apply the safety instructions in Section 1 and follow the manufacturers instructions on the underseal/wax container. 5.2. Preparing the gun for use. 5.2.1. Pour the underseal/wax into the SG16.V4 canister, screwthecanisterontothegun,(fig.2.A). 5.2.2. Attachnozzle(fig.2.C)tothegun.Ensurethatthe nozzleisnotscrewedtoofarintothegunasthiswillaffecttheefficiencyofthedelivery.Tightenthenozzlelocknut. 5.2.3. Ensure the air supply is regulated to no more than 8bar (115psi) and then attach the air hose to the gun. 5.2.4. Adjusttheaircontrolvalvetoachievethedesiredflowofmaterialbeingapplied. 5.2.5. Aim the nozzle of the gun into a safe area and depress the gun trigger to check for correct operation. It may be necessary to adjust
the position of the nozzle in the gun to achieve the most effective delivery. 5.3. Using the injection probe 5.3.1. TheSG16.V4issuppliedwithaninjectionprobe(fig.2.D)for use with wax.Theflexibleinjectionprobeenableswaxtobesprayed
into cavities, between panels and inside doors etc. 5.3.2. Theinjectionprobe(fig.2.D)isinterchangeablewiththenozzle(fig.2.C)onthegun.Removethelocknutfromthenozzleandattach
ittotheinjectionprobe.Ensurethattheinjectionprobeisnotscrewedtoofarintothegunasthiswillaffecttheefficiencyofthe delivery.Tightenthelocknuttoholdtheinjectionprobeinpositionandattachthecanister(fig.2.A)tothegun.
5.3.3. Ensure the air supply is regulated to no more than 8bar (115psi) and then attach the air hose to the gun. 5.3.4. Adjusttheaircontrolvalvetoachievethedesiredflowofmaterialbeingapplied. 5.3.5. Aim the injection probe into a safe area and depress the gun trigger to check for correct operation. It may be necessary to adjust the
position of the injection probe in the gun to achieve the most effective delivery.
6. MAINTENANCE WARNING! Ensure the gun is disconnected from the air supply before attempting any maintenance. It is very important to keep the
gun and components clean to ensure free passage for the underseal/wax. 6.1. After use clean all items thoroughly, especially the probe, with a suitable cleaning agent and allow to dry before storage.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice. IMPORTANT: No liability is accepted for incorrect use of this product. WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
Sole UK Distributor, Sealey Group.
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk.
IP32 7AR
www.sealey.co.uk
sales@sealey.co.uk
01284 757500
01284 703534
Web
fig.1 fig.2
Environmental Protection Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted,
taken to a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable)
<