Samsung FE-N300WX Cooker Installation Guide PDF

1 of 24
1 of 24

Summary of Content for Samsung FE-N300WX Cooker Installation Guide PDF

imagine the possibilities Thank you for purchasing this Samsung product.

Electric Range installation manual

Install_30_Electric_Range_USA_DG68-00108G-10_EN+MES.indb 1 2020-03-12 11:26:30

before you begin ANTI-TIP DEVICE

WARNING: To reduce the risk of tipping the appliance, the appliance must be secured by properly installed anti-tip devices packed with the appliance. a) A child or adult can tip the range and be killed. b) Install the anti-tip device to the structure and/or the range at rear right (or rear left)

of the range bottom. c) Engage the range to the anti-tip device by leveling leg at rear right (or rear left) of

the range bottom. d) Re-engage the anti-tip device if the range is moved. e) See installation instructions for details. f) Failure to do so can result in death or serious burns to children or adults.

ABOUT THIS MANUAL READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY.

Important note to the installer Read all instructions contained in these installation instructions before installing range.

Remove all packing materials from the oven compartments before connecting the electrical supply to the range.

Observe all governing codes and ordinances.

Be sure to leave these instructions with the consumer.

Important note to the consumer Keep these instructions for the local electrical inspectors use.

As when using any appliance generating heat, there are certain safety precautions you should follow.

Be sure your range is installed and grounded properly by a qualified installer or service technician.

Make sure the wall coverings around the range can withstand the heat generated by the range.

To eliminate the need to reach over the surface elements, cabinet storage space above the elements should be avoided.

The range should not be placed on a base.

FOR YOUR SAFETY

WARNING WARNING If the information in this manual is not followed exactly, a fire or electrical shock may result causing property damage, personal injury or death.

WARNING WARNING Before beginning the installation, switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

WARNING WARNING This appliance must be properly grounded.

WARNING

English - 2

Install_30_Electric_Range_USA_DG68-00108G-10_EN+MES.indb 2 2020-03-12 11:26:30

preparing to install the range REMOVE PACKAGING

Remove packaging materials. Failure to remove packaging materials could result in damage to the appliance.

PREPARE TOOLS & PARTS

What tools you will need

Drill Adjustable Wrench Pliers 1/4" Nut Driver

Phillips Screwdriver Flat Screwdriver Pencil Level

Whats included with your range

Template Anti-Tip Bracket Screws (4 ea)

Whats not included

4-Wire Cord or 3-Wire Cord (UL Approved 40 or 50 AMP)

Strain Relief (For Conduit Installation Only)

English - 3

01 B E

FO R

E YO

U B

E G

IN &

P R

E PA

R IN

G TO

IN S

TA LL TH

E R

A N

G E

Install_30_Electric_Range_USA_DG68-00108G-10_EN+MES.indb 3 2020-03-12 11:26:31

CHECKING THE INSTALLATION SITE

Clearances and dimensions To install the range, refer to the following figure.

For installation in CANADA, a Free-standing range is not to be installed closer than 12mm from any adjacent surface.

CAUTION CAUTION This range has been designed to comply with the maximum allowable wood cabinet temperatures of 194 F. Make sure the wall covering, countertops and cabinets around the range can withstand the heat (up to 194 F) generated by the range. If not, discoloration, delamination or melting may occur.

A

B

36" ~ 37"

461/2" ~ 471/2"

2915/16"

19/16"

247/8"

71/2"

241/2"

261/16"

493/8"

287/16"

297/8"

6"

25"

3"

24" 3"

A : Cabinet opening

30" For U.S.A,

30"~31" For CANADA.

B : Acceptable electrical outlet area

Minimum dimensions

IMPORTANT To eliminate the risk of burns or fire caused by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5" beyond the bottom of the cabinets.

* 30"

30"

** 15" * 30" minimum clearance between the top

of the cooking surface and the bottom of an unprotected wood or metal cabinet; or 24" minimum when the bottom of the wood or metal cabinet is protected by not less than 1/4" flame retardant millboard covered with not less than no.28 MSG sheet steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper.

** 15" minimum between the countertop and the adjacent cabinet bottom.

English - 4

Install_30_Electric_Range_USA_DG68-00108G-10_EN+MES.indb 4 2020-03-12 11:26:32

connecting the power STEP 1. MEETING ELECTRICAL CONNECTION REQUIREMENTS

CAUTION CAUTION For personal safety, do not use an extension cord with this appliance. Remove house fuse or open circuit breaker before beginning installation.

This appliance must be supplied with the proper voltage and frequency, and connected to an individual properly grounded branch circuit, protected by a circuit breaker or fuse having amperage as specified on the rating plate. The rating plate is located above the drawer on the oven frame. (Fig. 1 or Fig. 2)

We recommend you have the electrical wiring and hookup of your range connected by a qualified electrician. After installation, have the electrician show you where your main range disconnect is located.

Check with your local utilities for electrical codes which apply in your area. Failure to wire your oven according to governing codes could result in a hazardous condition. If there are no local codes, your range must be wired and fused to meet the requirements of the National Electrical Code, ANSI/NFPA No. 70Latest Edition. You can get a copy by writing:

National Fire Protection Association

Batterymarch Park

Quincy, MA 02269

Effective January 1, 1996, the National Electrical Code requires that new construction (not existing) utilize a 4-conductor connection to an electric range.

When installing an electric range in new construction, follow Steps 2 and 3 for 4-wire connection.

You must use a 3-wire or 4-wire, single-phase A.C. 208Y/120 Volt or 240/120 Volt, 60 hertz electrical system.

If the electrical service provided does not meet the above specifications, have a licensed electrician install an approved outlet.

Use only a 3-conductor or a 4-conductor UL-listed range cord. These cords may be provided with ring terminals on wire and a strain relief device.

A range cord rated at 40 amps with 125/250 minimum volt range is required. A 50 amp range cord is not recommended but if used, it should be marked for use with nominal 138" diameter connection openings. Care should be taken to center the cable and strain relief within the knockout hole to keep the edge from damaging the cable.

Because range terminals are not accessible after range is in position, flexible service conduit or cord must be used.

NOTE If conduit is being used, go to Step 4 on page 9.

ALL NEW BRANCH-CIRCUIT CONSTRUCTIONS, MOBILE HOMES, RECREATIONAL VEHICLES AND INSTALLATIONS WHERE LOCAL CODES DO NOT ALLOW GROUNDING THROUGH NEUTRAL, REQUIRE A 4-CONDUCTOR UL-LISTED RANGE CORD.

(Fig. 1)

(Fig. 2)

English - 5

02 C O

N N

E C

TIN G

TH E

P O

W E

R

Install_30_Electric_Range_USA_DG68-00108G-10_EN+MES.indb 5 2020-03-12 11:26:32

STEP 2. ACCESSING THE POWER CORD CONNECTION Remove the rear access cover and loosen the screw with a screwdriver. The terminal block will then be accessible.

Access cover

Terminal block

Specified power-supply-cord kit rating

Range rating, watts Specified rating of power-supply-cord

kit, amperes

Diameter (inches) of range connection opening

120 / 240 volts 3-wire 120 / 208 volts 3-wire Power cord Conduit

8,750 - 16,500 7,801 - 12,500 40 or 50A 13/8" 11/8"

STEP 3. INSTALLING THE POWER CORD For power cord installations, hook the strain relief over the power cord hole (13/8") located below the rear of the drawer body. Insert the power cord through the strain relief and tighten the device.

Strain relief

Power cord

Conduit connection plate

You must install the power cord with a strain relief.

Attach the strain relief to the 13/8" opening in conduit connection plate.

English - 6

Install_30_Electric_Range_USA_DG68-00108G-10_EN+MES.indb 6 2020-03-12 11:26:33

Installing a 3-wire power cord

WARNING WARNING The neutral or ground wire of the power cord must be connected to the neutral terminal located in the center of the terminal block. The power leads must be connected to the lower left and the lower right terminals of the terminal block.

1. Remove the 3 lower terminal screws from the terminal block.

2. Insert the 3 terminal screws through each power cord terminal ring and into the lower terminals of the terminal block. Be certain that the center wire (white/neutral) is connected to the center lower position of the terminal block.

3. Tighten screws securely into the terminal block. DO NOT remove the ground strap connection.

4. Go to step 5 on page 10 and proceed with the installation.

Ground strap

Live 2

Neutral terminal

Live 1 Black

White

Red

Black White Red

Installing a 4-wire power cord

WARNING WARNING The neutral wire of the supply circuit must be connected to the neutral terminal located in the lower center of the terminal block. The power leads must be connected to the lower left and the lower right terminals of the terminal block. The 4th grounding lead must be connected to the frame of the range with the ground plate and the ground screw.

1. Remove the 3 lower terminal screws from the terminal block. Remove the ground screw and ground plate and retain them.

2. Cut and discard the ground strap. Do not discard any screws.

3. Insert the one ground screw into the power cord ground wire terminal ring, through the ground plate, and into the frame of the range.

4. Insert the 3 terminal screws (removed earlier) through each power cord terminal ring and into the lower terminals of the terminal block. Be certain that the center wire (white/neutral) is connected to the center lower position of the terminal block. Tighten screws securely into the terminal block.

5. Go to step 5 on page 10 and proceed with the installation.

Ground strap

Ground plate

Ground screw

Neutral terminal

Ground wire (Green)

White Black Red

Black White

Red

Live 2

Live 1

CAUTION CAUTION You must check voltage after connecting power cord.

Live 1 - Neutral 120 V Live 2 - Neutral 120 V Live 1 - Live 2 208 V / 240 V

English - 7

02 C O

N N

E C

TIN G

TH E

P O

W E

R

Install_30_Electric_Range_USA_DG68-00108G-10_EN+MES.indb 7 2020-03-12 11:26:33

STEP 4. INSTALLING THE CONDUIT Remove the conduit connection plate from the rear of the drawer body and rotate it as shown below.

The conduit hole (11/8") must be used.

11/8" 13/8"

11/8"13/8"

1. Prepare the conduit cord shown in Figure 1.

2. Install the conduit cord as shown in Figure 2.

Conduit connection plate Strain relief

Ring

Body

Figure 2

1"

31/2"

3/8" 1"

31/2"

3 wire 4 wire

Knockout surface

Figure 1 3/8"

For conduit installations, insert the strain relief (not included) into the conduit hole (11/8"). Then thread the conduit cord through the body of the strain relief and fasten the ring. Reinstall the bracket.

Installing a 3-wire conduit Aluminum building wire may be used but it must be rated for the correct amperage and voltage to make

the connection. Connect wires according to Step 4 depending on the number of wires. Wire used, location and enclosure of splices, etc., must conform to good wiring practices and local codes. 1. Loosen the 3 lower terminal screws from the terminal

block.

2. Insert the center bare wire (white/neutral) tip through the bottom center terminal block opening. On certain models, the wire will need to be inserted through the ground strap opening and then into the bottom center block opening.

3. Insert the two side bare wire tips into the lower left and the lower right terminal block openings.

4. Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.). Do not over-tighten the screws since it could damage the wires.

5. Go to step 5 on page 10 and proceed with the installation.

WhiteBlack Red

Ground strap

Neutral terminal

Wire tips

Red

White

Black

Live 2 Live 1

CAUTION CAUTION You must check voltage after connecting power cord.

Live 1 - Neutral 120 V Live 2 - Neutral 120 V Live 1 - Live 2 208 V / 240 V

English - 8

Install_30_Electric_Range_USA_DG68-00108G-10_EN+MES.indb 8 2020-03-12 11:26:34

Installing a 4-wire conduit Aluminum building wire may be used but it must be rated for the correct amperage and voltage to make

the connection. Connect wires according to this Step 4 depending on the number of wires.

Wire used, location and enclosure of splices, etc., must conform to good wiring practices and local codes. 1. Loosen the 3 lower terminal screws from the terminal block. Remove the ground screw and

ground plate and retain them.

2. Cut and discard the ground strap. Do not discard any screws.

3. Insert the ground bare wire tip between the range frame and the ground plate (removed earlier) and secure it in place with the ground screw (removed earlier).

4. Insert the bare wire (white/neutral) tip through the bottom center of the terminal block opening.

5. Insert the two side bare wire tips into the lower left and the lower right terminal block openings.

6. Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.). Do not over-tighten the screws since it could damage the wires.

7. Go to step 5 and proceed with the installation.

Ground strap

Ground plate

WhiteBlack Red Neutral terminal

Ground wire (Green)

Wire tips White Black

Red

Live 2 Live 1

CAUTION CAUTION You must check voltage after connecting power cord.

Live 1 - Neutral 120 V Live 2 - Neutral 120 V Live 1 - Live 2 208 V / 240 V

STEP 5. REPLACING THE ACCESS COVER Replace the access cover on the range back. To replace the wire cover, insert double projections in the pockets located below the opening and tighten the screw.

English - 9

02 C O

N N

E C

TIN G

TH E

P O

W E

R

Install_30_Electric_Range_USA_DG68-00108G-10_EN+MES.indb 9 2020-03-12 11:26:34

installing the range INSTALLING THE ANTI-TIP DEVICE

WARNING WARNING To reduce the risk of tipping, the appliance must be secured by properly installing the Anti-Tip device packed with the appliance.

Refer to the installation instructions supplied with the bracket.

Unless properly installed, the range could be tipped by stepping or sitting on the door. Injury may result from spilled hot liquids or from the range itself.

Anti-Tip bracket

Screw must enter wood or concrete

*approximately 21/32"(16.5mm)

*NOTE: To install Anti-Tip bracket, release the leveling leg. A minimum clearance of 21/32"(16.5mm) is required between the range bottom and the kitchen floor.

1. Locate the bracket using the template The Anti-Tip bracket is packaged with a template. The instructions include information necessary to complete the installation. Read and follow the instructions on the sheet (template) for range installation.

2. Level the range Level the range by adjusting the leveling legs with a wrench.

Lower range

Raise range

Leveling leg

English - 10

Install_30_Electric_Range_USA_DG68-00108G-10_EN+MES.indb 10 2020-03-12 11:26:34

3. Check your adjustments Use a spirit level to check your adjustments. Place the level diagonally on the oven rack or surface cooktop, and check each direction for level.

1. Check direction 1.

2. Check direction 2.

If the spirit level doesnt show level on the oven rack or surface cooktop, adjust the leveling legs with a wrench.

CAUTION CAUTION For your safety, do not attempt to modify or straighten front legs. Front leveling legs on the range are designed to be slanted to prevent accidental tipping.

Ground

FINALIZING THE INSTALLATION Move range close enough to the opening to plug into the receptacle.

Slide range into position insuring that the rear left(or rear right) leg slides under the Anti-Tip bracket. The range will sit 0" away from the back wall when properly installed.

Carefully tip the range forward to insure that the Anti-Tip bracket engages the back brace and prevents tip-over.

Turn on the electrical power. Check the range for proper operation as described in the user manual.

Anti-Tip bracket

Leveling leg

English - 11

03 IN S

TA LLIN

G TH

E R

A N

G E

Install_30_Electric_Range_USA_DG68-00108G-10_EN+MES.indb 11 2020-03-12 11:26:35

DG68-00108G-10

FOR NE59*33**, NE59*43** SERIES SET THE APPROPRIATE POWER VOLTAGE FOR BEST PERFORMANCE

1. Check input power voltage. (Live 1 Live 2)

2. If the input voltage is 240 V, done. If the input voltage is 208 V, follow the step 3.

3. Press Keep Warm and (Num 0) 3 sec on same time.

4. Display shows 240 and Press (Num 0) to set 208.

5. Press START/SET to confirm.

English - 12

Install_30_Electric_Range_USA_DG68-00108G-10_EN+MES.indb 12 2020-03-12 11:26:35

imagine las posibilidades Gracias por adquirir este producto Samsung.

Estufa elctrica manual de instalacin

Install_30_Electric_Range_USA_DG68-00108G-10_EN+MES.indb 1 2020-03-12 11:26:36

antes de comenzar DISPOSITIVO ANTI INCLINACIN

ADVERTENCIA: Para reducir el riesgo de inclinaciones, el artefacto debe quedar correctamente fijado mediante la instalacin de los dispositivos anti inclinacin que vienen con el equipo. a) Un nio o un adulto podran inclinar la estufa y morir. b) Instale el dispositivo anti inclinacin en la estructura y/o en la parte posterior derecha

(o posterior izquierda) de la base de la estufa. c) Acople la estufa en el dispositivo anti inclinacin nivelando las patas en la parte posterior

derecha (o posterior izquierda) de la base de la estufa. d) Vuelva a acoplar el dispositivo anti inclinacin en caso de mover la estufa. e) Consulte las instrucciones de instalacin para obtener ms informacin. f) No hacerlo puede provocar la muerte o quemaduras serias a nios o adultos.

ACERCA DE ESTE MANUAL LEA ESTAS INSTRUCCIONES EN SU TOTALIDAD Y CUIDADOSAMENTE.

Nota importante para el instalador Lea todas las instrucciones contenidas en este manual antes de instalar la estufa.

Retire de la estufa todos los materiales de empaque de los compartimientos del horno antes de conectar la alimentacin elctrica a la estufa.

Cumpla todos los cdigos y ordenanzas exigidos por las autoridades pertinentes.

Asegrese de dejar estas instrucciones con el usuario final.

Nota importante para el usuario final Guarde estas instrucciones para que puedan ser consultadas por el inspector del servicio elctrico de su localidad.

Como con cualquier electrodomstico que genera calor, existen ciertas precauciones de seguridad que se deben cumplir.

Asegrese de que su electrodomstico sea correctamente instalado y conectado a tierra por un tcnico calificado.

Asegrese de que los revestimientos de las paredes alrededor de la estufa pueden soportar el calor que sta genera.

Para evitar tener que alcanzar objetos por encima de los elementos radiantes de la superficie, se desaconseja la instalacin de gabinetes de almacenamiento en el espacio arriba de tales elementos.

La estufa no debe colocarse sobre una base.

PARA SU SEGURIDAD

ADVERTENCIA ADVERTENCIA Si la informacin de este manual no es seguida con exactitud, se podran producir incendios o descargas elctricas causantes de daos a la propiedad, lesiones personales, o la muerte.

ADVERTENCIA ADVERTENCIA Antes de comenzar la instalacin, corte la alimentacin elctrica desde el panel de servicio y cierre con llave el dispositivo de desconexin para evitar que la corriente elctrica sea conectada accidentalmente. Si resulta imposible cerrar con llave el dispositivo de desconexin del servicio, fije en forma segura sobre el panel de servicio alguna forma muy notoria de advertencia, tal como un cartel o marbete.

ADVERTENCIA ADVERTENCIA Este electrodomstico debe conectarse debidamente a tierra.

ADVERTENCIA

Espaol - 2

Install_30_Electric_Range_USA_DG68-00108G-10_EN+MES.indb 2 2020-03-12 11:26:36

preparacin para instalar la estufa RETIRE EL MATERIAL DE EMPAQUE

Retire el material de empaque. No retirar los materiales de empaque podra causar daos al electrodomstico.

PREPARE LAS HERRAMIENTAS Y LAS PIEZAS

Las herramientas que necesitar.

Taladro Llave ajustable Pinzas Desarmador de caja para tuercas de 1/4"

Desarmador Phillips Desarmador plano Lpiz Nivel

Elementos incluidos con su estufa

Plantilla Mnsula anti inclinacin Tornillos (4 unid.)

Elementos no incluidos con su estufa

Cable de 4 conductores o cable de 3 conductores

(de 40 o 50 AMP, aprobados por United Laboratories, Inc. ("UL"))

Sujetador de cables con amortiguador de esfuerzo

(nicamente para instalacin con conducto)

Espaol - 3

01 AN

TES D E C

O M

EN ZAR Y PREPARAC

I N

PARA IN STALAR LA ESTU

FA

Install_30_Electric_Range_USA_DG68-00108G-10_EN+MES.indb 3 2020-03-12 11:26:36

INSPECCIN DEL SITIO DE INSTALACIN

Distancias, espacios libres y dimensiones Para instalar la estufa, observe la figura a continuacin.

Para instalaciones en CANAD, una estufa de pie no debe instalarse a menos de 12 mm de cualquier superficie adyacente.

PRECAUCIN PRECAUCIN Esta estufa ha sido diseada para cumplir con la temperatura mxima admisible para gabinetes de madera de 194 F. Asegrese de que los revestimientos de paredes, superficies de mesada y gabinetes alrededor de la estufa puedan soportar el calor (hasta 194 F) generado por la estufa. De lo contrario, se podran producir alteraciones de color, deslaminacin o derretimiento.

A

B

36" ~ 37"

461/2" ~ 471/2"

2915/16"

19/16"

247/8"

71/2"

241/2"

261/16"

493/8"

287/16"

297/8"

6"

25"

3"

24" 3"

A: Espacio entre gabinetes

30 pulgadas para los EE. UU.,

30~31 pulgadas para CANAD.

B: rea admisible para toma de corriente

Dimensiones mnimas

IMPORTANTE Para eliminar el riesgo de quemaduras o de incendio provocado por contacto con las unidades sobrecalentadas en superficie, debe evitarse colocar gabinetes de almacenamiento por encima de las unidades de superficie. Si deben instalarse gabinetes de almacenamiento, el riesgo puede reducirse instalando una campana para estufas que se proyecte horizontalmente por lo menos 5" ms all de la parte inferior de los gabinetes.

* 30"

30"

** 15"

* Separacin mnima de 30 pulgadas entre el extremo superior de la superficie de coccin y el extremo inferior de un gabinete de madera o metal no protegido; mnima de 24 pulgadas cuando el extremo inferior del gabinete de madera o metal est protegido por un tablero ignfugo de un mnimo de 1/4" cubierto con una lmina de acero Nro. 28, como mnimo, 0.015" de acero inoxidable, 0.024" de aluminio o 0.020" de cobre.

** 15" como mnimo entre la superficie de la mesada y la parte inferior del gabinete ms cercano.

Espaol - 4

Install_30_Electric_Range_USA_DG68-00108G-10_EN+MES.indb 4 2020-03-12 11:26:37

PASO 1. CUMPLIMIENTO DE LAS EXIGENCIAS DE CONEXIN ELCTRICA

PRECAUCIN PRECAUCIN Para seguridad de las personas, no utilice cables prolongadores con este electrodomstico. Quite el fusible de su casa o corte la electricidad con el disyuntor antes de comenzar la instalacin.

Este electrodomstico debe ser alimentado con el voltaje y la frecuencia correctos, y debe conectarse a un ramal de circuito individual correctamente conectado a tierra y protegido con un disyuntor o fusible cuyo amperaje debe concordar con lo establecido en la placa de especificaciones. La placa de especificaciones se encuentra ubicada arriba del cajn en el marco del horno. (Fig. 1 o Fig. 2)

Le recomendamos que el cableado y la conexin de su estufa sean realizados por un electricista calificado. Luego de la instalacin, solictele al electricista que le muestre dnde se encuentra el principal dispositivo de desconexin de su estufa.

Verifique con su empresa local de servicio elctrico los cdigos elctricos vigentes en su rea. Si el cableado de su horno no se hace de acuerdo con los cdigos en vigencia se podran generar condiciones peligrosas. Si no hay cdigos locales, su estufa debe ser cableada y equipada con fusibles que cumplan los requisitos del National Electrical Code, ANSI/NFPA No. 70Latest Edition. Para obtener una copia, escriba a:

National Fire Protection Association

Batterymarch Park

Quincy, MA 02269

Con vigencia a partir del 1 de enero de 1996, el National Electrical Code (Cdigo Elctrico Nacional) exige que en las construcciones nuevas (no existentes en ese momento) para estufas de cocina se utilicen conexiones de cuatro conductores.

Cuando instale una estufa elctrica en una construccin nueva, siga los Pasos 2 y 3 para conexin de 4 conductores.

Debe usar un sistema elctrico de 3 o 4 conductores, monofsico, CA. 208Y/120 voltios o 240/120 voltios, 60 hertz.

Si el servicio elctrico provisto no cumple con las especificaciones anteriores, haga que un electricista con licencia le instale un tomacorriente aprobado.

Utilice nicamente un cable para estufas de 3 o 4 conductores incluido en las listas de UL. Estos cables pueden venir con terminales de aro y un dispositivo de sujecin con amortiguador de esfuerzo.

Se requiere un cable para estufas apto para 40 amps. con un rango de voltaje mnimo de 125/250 voltios. No se recomienda el uso de cables de 50 amps., pero si se lo utiliza debe estar marcado para uso con aberturas de conexin de 138 pulgadas de dimetro. Se debe prestar cuidado de centrar el cable y el sujetador con amortiguador de esfuerzo dentro del orificio de salida para evitar que el borde dae el cable.

Dado que las terminales no quedan accesibles una vez que la estufa est en posicin, se debe usar conducto o cable flexible.

NOTA Si se utiliza un conducto, vaya al Paso 4 en la pgina 9.

TODAS LAS NUEVAS CONSTRUCCIONES DE CIRCUITOS RAMALES, CASAS RODANTES, VEHCULOS RECREATIVOS E INSTALACIONES DONDE LOS CDIGOS LOCALES NO PERMITEN LA CONEXIN A TIERRA MEDIANTE EL NEUTRO, REQUIEREN UN CABLE PARA ESTUFAS DE 4 CONDUCTORES INCLUIDOS EN LOS LISTADOS DE UL.

cmo conectar la corriente elctrica

(Fig. 1)

(Fig. 2)

Espaol - 5

02 C

O N

E X

I N

A LA

C O

R R

IE N

TE E

L C

TR IC

A

Install_30_Electric_Range_USA_DG68-00108G-10_EN+MES.indb 5 2020-03-12 11:26:37

PASO 2. CMO ACCEDER A LA CONEXIN DEL CABLE DE ALIMENTACIN ELCTRICA Retire la cubierta de acceso de la parte posterior y afloje el tornillo con un desarmador. Habr quedado abierto el acceso al cuerpo de terminales.

Cubierta de acceso

Cuerpo de terminales

Especificaciones del kit de cable para alimentacin elctrica.

Especificacin de estufa, watts Especificaciones del kit de cable para

alimentacin elctrica, en amperes.

Dimetro (en pulgadas) de la abertura para conexin de la estufa

120 / 240 voltios 3-conductores

120 / 208 voltios 3-conductores

Cable de la alimentacin

Conducto

8750-16500 7801-12500 40 o 50 A 13/8" 11/8"

PASO 3. INSTALACIN DEL CABLE DE ALIMENTACIN ELCTRICA Cuando se realicen instalaciones de cables de alimentacin, enganche el sujetador de cables con amortiguador de esfuerzo sobre el orificio del cable de alimentacin (13/8") ubicado debajo de la parte trasera del cuerpo del cajn. Inserte el cable de alimentacin atravesando el sujetador-amortiguador y ajuste el dispositivo.

Sujetador de cable con amortiguador de esfuerzo

Cable de la alimentacin

Placa de conduccin del conducto

El cable de alimentacin se debe instalar con un sujetador-amortiguador.

Fije el sujetador de cables con amortiguador de esfuerzo a la abertura de 13/8" en la placa de conexin del conducto.

Espaol - 6

Install_30_Electric_Range_USA_DG68-00108G-10_EN+MES.indb 6 2020-03-12 11:26:37

Instalacin de un cable de alimentacin de 3 conductores

ADVERTENCIA ADVERTENCIA El conductor neutral o de tierra del cable de alimentacin debe conectarse a la terminal neutra ubicada en el centro del cuerpo de terminales. Los chicotes de cable que portan corriente deben conectarse a las terminales inferior izquierda e inferior derecha del cuerpo de terminales.

1. Retire los tornillos de las tres terminales inferiores del cuerpo de terminales.

2. Introduzca los 3 tornillos terminales a travs de cada aro terminal del cable de alimentacin y dentro de las terminales inferiores del cuerpo de terminales. Asegrese de que el conductor central (blanco/ neutro) sea conectado a la posicin central inferior del cuerpo de terminales.

3. Ajuste los tornillos al cuerpo de terminales en forma segura. NO retire la cinta de conexin a tierra.

4. Vaya al paso 5 en la pgina 10 y contine con la instalacin.

Cinta de conexin a tierra

Fase 2

Terminal neutra

Fase 1 Negro

Blanco

Rojo

Negro Blanco Rojo

Instalacin de un cable de alimentacin de 4 conductores

ADVERTENCIA ADVERTENCIA El conductor neutro del circuito de alimentacin debe conectarse a la terminal neutra ubicada en la parte central inferior del cuerpo de terminales. Los chicotes de cable que portan corriente deben conectarse a las terminales inferior izquierda e inferior derecha del cuerpo de terminales. El cuarto chicote de conexin a tierra debe conectarse al marco de la estufa con la chapa y el tornillo de conexin a tierra.

1. Retire los tornillos de las tres terminales inferiores del cuerpo de terminales. Retire el tornillo y la chapa de conexin a tierra y gurdelos.

2. Corte y descarte la cinta de conexin a tierra. No descarte ningn tornillo. 3. Introduzca el nico tornillo de tierra en la terminal de aro de tierra del cable de alimentacin, tambin a

travs de la chapa de conexin a tierra y dentro del marco de la estufa. 4. Introduzca los 3 tornillos terminales (retirados anteriormente) a travs de cada aro terminal del cable

de alimentacin y dentro de las terminales inferiores del cuerpo de terminales. Asegrese de que el conductor central (blanco/neutro) sea conectado a la posicin central inferior del cuerpo de terminales. Ajuste los tornillos al cuerpo de terminales en forma segura.

5. Vaya al paso 5 en la pgina 10 y contine con la instalacin.

Cinta de conexin a tierra

Chapa de conexin a tierra

Tornillo de conexin a tierra

Terminal neutra

Conductor a tierra (Verde)

Blanco Negro Rojo

Negro Blanco

Rojo

Fase 2

Fase 1

PRECAUCIN PRECAUCIN Debe verificar el voltaje despus de conectar el cable de alimentacin.

Fase 1 - Neutro 120 V Fase 2 - Neutro 120 V Fase 1 - Fase 2 208 V / 240 V

Espaol - 7

02 C

O N

E X

I N

A LA

C O

R R

IE N

TE E

L C

TR IC

A

Install_30_Electric_Range_USA_DG68-00108G-10_EN+MES.indb 7 2020-03-12 11:26:38

PASO 4. INSTALACIN DEL CONDUCTO

Retire la placa de conexin del conducto de la parte trasera del cuerpo del cajn y rtela como se muestra abajo. Se debe utilizar el orificio de conducto (11/8").

11/8" 13/8"

11/8"13/8"

1. Prepare el cable de conducto que se muestra en la Figura 1.

2. Instale el cable de conducto como se muestra en la Figura 2.

Placa de conduccin del conducto

Sujetador de cable con amortiguador de esfuerzo

Aro

Cuerpo

Figura 2

1"

31/2"

3/8" 1"

31/2"

3 conductores 4 conductores

Superficie de salida

Figura 1 3/8"

En el caso de instalaciones de conducto, introduzca el sujetador de cables con amortiguador de esfuerzo (no incluido) en el orificio del conducto (11/8"). Luego pase el cable de conducto a travs del cuerpo del sujetador-amortiguador y ajuste el tornillo. Reinstale la placa.

Instalacin de un conducto de tres conductores Se puede utilizar alambre de construccin de aluminio pero debe estar graduado y aprobado para los amperajes y voltajes correctos

para hacer la conexin. Conecte los conductores de acuerdo con el Paso 4, dependiendo del nmero de conductores. Los conductores utilizados, la ubicacin y el encapsulamiento de uniones, etc. deben cumplir con las buenas prcticas de cableado y

los cdigos locales. 1. Afloje los tornillos de las 3 terminales inferiores del cuerpo de terminales.

2. Introduzca la punta desnuda del conductor central (blanco/neutro) a travs de la abertura en la parte central inferior del cuerpo de terminales. En ciertos modelos, ser necesario introducir el conductor a travs de la abertura de la cinta de conexin a tierra y luego dentro de la abertura en la parte central inferior del cuerpo de terminales.

3. Introduzca las puntas desnudas de los dos conductores laterales en las aberturas inferior izquierda e inferior derecha del cuerpo de terminales.

4. Ajuste los tornillos hasta que los conductores queden firmemente anclados (35 a 50 pulgadas-libras de torque). No ajuste los tornillos en exceso porque esto podra daar los conductores.

5. Vaya al paso 5 en la pgina 10 y contine con la instalacin. BlancoNegro Rojo

Cinta de conexin a tierra

Terminal neutra

Puntas de conductor

Rojo

Blanco

Negro

Fase 2 Fase 1

PRECAUCIN PRECAUCIN Debe verificar el voltaje despus de conectar el cable de alimentacin.

Fase 1 - Neutro 120 V Fase 2 - Neutro 120 V Fase 1 - Fase 2 208 V / 240 V

Espaol - 8

Install_30_Electric_Range_USA_DG68-00108G-10_EN+MES.indb 8 2020-03-12 11:26:38

Instalacin de un conducto de cuatro conductores

Se puede utilizar alambre de construccin de aluminio pero debe estar graduado y aprobado para los amperajes y voltajes correctos para hacer la conexin. Conecte los conductores de acuerdo con este Paso 4, dependiendo del nmero de conductores.

Los conductores utilizados, la ubicacin y el encapsulamiento de uniones, etc. deben cumplir con las buenas prcticas de cableado y los cdigos locales.

1. Afloje los tornillos de las 3 terminales inferiores del cuerpo de terminales. Retire el tornillo y la chapa de conexin a tierra y gurdelos. 2. Corte y descarte la cinta de conexin a tierra. No descarte ningn tornillo. 3. Inserte la punta desnuda del conductor de tierra entre el marco de la estufa y la chapa de conexin a tierra (retirados anteriormente)

y fjelo en su lugar con el tornillo de conexin a tierra. 4. Introduzca la punta desnuda del conductor (blanco/neutro) a travs de la abertura en la parte central inferior del cuerpo de

terminales. 5. Introduzca las puntas desnudas de los dos conductores laterales en las aberturas inferior izquierda e inferior derecha del cuerpo de

terminales. 6. Ajuste los tornillos hasta que los conductores queden firmemente anclados (35 a 50 pulgadas-libras de torque). No ajuste los

tornillos en exceso porque esto podra daar los conductores. 7. Vaya al paso 5 y contine con la instalacin.

Cinta de conexin a tierra

Chapa de conexin a tierra

BlancoNegro Rojo

Terminal neutra

Conductor a tierra (Verde)

Puntas de conductor

Blanco

Negro Rojo

Fase 2 Fase 1

PRECAUCIN PRECAUCIN Debe verificar el voltaje despus de conectar el cable de alimentacin.

Fase 1 - Neutro 120 V Fase 2 - Neutro 120 V Fase 1 - Fase 2 208 V / 240 V

PASO 5. RECOLOCAR LA CUBIERTA DE ACCESO Recoloque la cubierta de acceso en la parte trasera de la estufa. Para recolocar la cubierta de los conductores, inserte las dos pestaas en las cavidades ubicadas debajo de la abertura y ajuste el tornillo.

Espaol - 9

02 C

O N

E X

I N

A LA

C O

R R

IE N

TE E

L C

TR IC

A

Install_30_Electric_Range_USA_DG68-00108G-10_EN+MES.indb 9 2020-03-12 11:26:39

instalacin de la estufa INSTALACIN DEL DISPOSITIVO ANTI INCLINACIN

ADVERTENCIA ADVERTENCIA Para reducir el riesgo de inclinaciones o vuelcos, el electrodomstico debe quedar correctamente asegurado mediante la instalacin del Dispositivo Anti Inclinacin que viene empacado con su electrodomstico.

Remtase a las instrucciones de instalacin incluidas con la mnsula.

Salvo que se encuentre correctamente instalada, la estufa se podra inclinar o volcar si alguna persona pisase la puerta o se sentara sobre ella. Podran ocurrir lesiones causadas por el mismo peso de la estufa o por derrames de lquidos calientes.

Mnsula anti inclinacin

El tornillo debe introducirse en madera o concreto.

*aproximadamente 21/32 pulgadas (16.5 mm)

*NOTA: Para instalar la mnsula Anti Inclinacin libere la pata niveladora. Se requiere una distancia mnima de 21/32 pulgadas (16.5 mm) entre la parte inferior de la estufa y el piso de la cocina.

1. Ubique la mnsula en la posicin adecuada utilizando la plantilla La mnsula anti inclinacin se encuentra empacada junto con una plantilla. Las instrucciones incluyen la informacin necesaria para completar la instalacin. Lea y siga las instrucciones en la hoja (plantilla) para la instalacin de la estufa.

2. Nivelacin de la estufa Nivele la estufa ajustando las patas niveladoras con una llave.

Bajar la estufa

Levantar la estufa

Pata niveladora

Espaol - 10

Install_30_Electric_Range_USA_DG68-00108G-10_EN+MES.indb 10 2020-03-12 11:26:39

3. Controle sus ajustes Utilice un nivel de burbuja de aire para controlar los ajustes. Coloque el nivel en diagonal sobre la parrilla del horno o la superficie de coccin y controle que est nivelado en todas direcciones.

1. Controle en la direccin 1.

2. Controle en la direccin 2.

Si el nivel de burbuja muestra alguna inclinacin en la parrilla o la superficie de coccin, ajuste las patas de nivelacin con una llave.

PRECAUCIN PRECAUCIN Para su seguridad, no trate de modificar ni enderezar las patas delanteras. Las patas de nivelacin delanteras de la estufa estn diseadas en forma inclinada para evitar el vuelco accidental.

Piso

FINALIZACIN DE LA INSTALACIN Mueva la estufa lo suficientemente cerca de su lugar como para enchufar en el tomacorriente.

Deslice la estufa a su posicin, asegurndose de que la pata trasera izquierda (o trasera derecha) se deslice por debajo de la mnsula anti inclinacin. Cuando se encuentre bien instalada, la distancia entre la estufa y la pared de atrs ser de 0".

Con cuidado, incline la estufa hacia adelante para verificar que la mnsula Anti Inclinacin engancha al puntal trasero e imposibilita el vuelco.

Encienda la corriente elctrica. Controle el funcionamiento correcto de la estufa tal como se describe en el manual del usuario.

Mnsula anti inclinacin

Pata niveladora

Espaol - 11

03 IN

S TA

LA C

I N

D E

LA E

S TU

FA

Install_30_Electric_Range_USA_DG68-00108G-10_EN+MES.indb 11 2020-03-12 11:26:40

PARA LAS SERIES NE59*33**, NE59*43** CONFIGURE EL VOLTAJE ADECUADO PARA EL MEJOR DESEMPEO

1. Verifique el voltaje de entrada. (Live 1 Live 2)

2. Si el voltaje de entrada es 240 V, finalice. Si el voltaje de entrada es 208 V, siga el paso 3.

3. Presione Keep Warm (Mantener caliente) y (Nmero 0) simultneamente durante 3 segundos.

4. La pantalla muestra 240 y presione (Nmero 0) para ajustar a 208.

5. Presione START/SET (INICIO/CONFIGURAR) para confirmar.

DG68-00108G-10

Espaol - 12

Install_

Manualsnet FAQs

If you want to find out how the FE-N300WX Samsung works, you can view and download the Samsung FE-N300WX Cooker Installation Guide on the Manualsnet website.

Yes, we have the Installation Guide for Samsung FE-N300WX as well as other Samsung manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Installation Guide should include all the details that are needed to use a Samsung FE-N300WX. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Samsung FE-N300WX Cooker Installation Guide is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Samsung FE-N300WX Cooker Installation Guide consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Samsung FE-N300WX Cooker Installation Guide free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Samsung FE-N300WX Cooker Installation Guide, simply download the document to your computer. Once downloaded, open the PDF file and print the Samsung FE-N300WX Cooker Installation Guide as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.