Contents

Roland FR-1X Owner's Manual PDF

1 of 80
1 of 80

Summary of Content for Roland FR-1X Owner's Manual PDF

FR-1x GB.book Page 1 Tuesday, November 8, 2011 11:44 AM

r

Owners Manual

WARNING

To reduce the risk of fire or electric shock, do not expose this device to rain or moisture.

The technology used in the FR-1x is covered by U.S. Patent No. 6.946.594.

IMPORTANT: THE WIRES IN THIS MAINS LEAD ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE.

BLUE: BROWN:

As the colours of the wires in the mains lead of this apparatus may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: The wire which is coloured BLUE must be connected to the terminal which is marked with the letter N or coloured BLACK. The wire which is coloured BROWN must be connected to the terminal which is marked with the letter L or coloured RED. Under no circumstances must either of the above wires be connected to the earth terminal of a three pin plug.

NEUTRAL LIVE

For the U.K.For the UK

For Canada

This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.

NOTICE

AVIS

For the USA

FEDERAL COMMUNICATIONS COMMISSION RADIO FREQUENCY INTERFERENCE STATEMENT

This product complies with the requirements of European Directive EMC 2004/108/EC.

For EU Countries

For EU countries

For the USA

For Canada

DECLARATION OF CONFORMITY Compliance Information Statement

V-Accordion FR-1x Digital Accordion Roland Corporation U.S. 5100 S. Eastern Avenue, Los Angeles, CA 90040-2938 (323) 890-3700

For the USA

FR-1x GB.book Page 2 Tuesday, November 8, 2011 11:44 AM

r

Owners Manual

HS IL

GN E

HS IL

GN E

HS IL

GN E

HS IL

GN E

Introduction

Thank you and congratulations on your choice of the Roland FR-1x V-Accordion. To ensure that you obtain the maximum enjoyment and take full advantage of the FR-1xs functionality, please read this owners manual carefully.

About this manual

You should first read the chapter Before you start playing (p. 15) of the owners manual. It explains how to connect the AC adaptor or install batteries and turn on the power. This Owners Manual explains everything, from the FR-1xs basic operations to more advanced functions.

Conventions in this manual

In order to explain the operations as clearly as possible, this manual uses the following conventions: Text enclosed in square brackets [ ] indicates the name of a button or knob. Example: the [USER PROGRAM] button. Lines that begin with are cautionary statements that you must read. The numbers of pages that you can turn to for additional, related information are given like this: (p. **).

The explanations in this manual include illustrations that depict what should typically be shown by the display. Note, however, that your unit may incorporate a newer, enhanced version of the system (e.g., include newer sounds), so what you actually see in the display may not always match what appears in the manual.

Before using this instrument, carefully read Using the unit safely (p. 7) and Important notes (p. 9). Those sections provide information concerning the proper operation of the FR-1x. Additionally, in order to feel assured that you have gained a good grasp of every feature provided by your new unit, the manual should be read in its entirety. The manual should be saved and kept on hand as a convenient reference.

NOTE

Copyright 2011 ROLAND. All rights reserved. No part of this publication may be reproduced in any form without the written permission of Roland Corporation. Roland is either a registered trademark or a trademark of Roland Corporation in the United States and/or other countries.

FR-1x GB.book Page 3 Tuesday, November 8, 2011 11:44 AM

4

FR-1x

V-Accordion

FR-1x GB.book Page 4 Tuesday, November 8, 2011 11:44 AM

r

1. Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

2. Important notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

3. A first look at your FR-1x . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 The sections of your FR-1x . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Bellows resistance regulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

4. Panel descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Treble control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Bass control panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Battery compartment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Connection panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

5. Before you start playing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Getting ready to play . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Installing and removing batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Connecting the FR-1x to an amplifier, mixer, etc.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Attaching the straps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Securing the adapter and/or MIDI cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Switching the power on and off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Using headphones. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 How to read the display. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

6. Listening to the demo songs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23

7. Using Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 Selecting Sets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

8. Selecting and playing sounds. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 Treble section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Bass and chord section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Playing drum/percussion sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Playing only bass notes with your left hand (Free Bass mode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

9. Using the FR-1xs audio player . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 Copying audio files to a USB memory. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Playing back audio files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Selecting audio files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Adjusting the playback level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

10. Highlighting some practical functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 Using the metronome . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Changing the key of the keyboard (transpose) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Adjusting the balance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Musette Detune. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Switching off the internal speakers (Speaker Mode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

11. Saving your settings (User Program) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 Saving the current settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Recalling a User Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Editing a User Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

12. Data management via the FR-1xs USB port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 Saving User Program memories to USB memory (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Loading User Program memories from USB memory (optional). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Loading User Set memories from USB memory (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Loading new sounds from a USB memory (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

13. Other settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43 Important remark about saving your settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Selecting the desired parameter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 PARAM LIST parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

Contents

V-Accordion

r

FR-1x GB.book Page 5 Tuesday, November 8, 2011 11:44 AM

14. Connecting to MIDI devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Connecting an external MIDI device to the FR-1x . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Communication via the USB COMPUTER port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 MIDI parameter list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Selecting the desired MIDI parameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 MIDI parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

15. Restoring the factory defaults. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Loading all factory settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Restoring the User Sets to their factory defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

16. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

17. Error messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68

18. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

19. Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Ways in which the FR-1x displays alphabetic characters of file names . . . . . . . . . . . . . . . . . . . . . . 71 MIDI implementation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 MIDI Implementation Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74

20. Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

21. Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76

5

Features

6

FR-1x V-Accordion

FR-1x GB.book Page 6 Tuesday, November 8, 2011 11:44 AM

r 1. Features

Stand-alone electronic instrument Though the FR-1x is a fully electronic instrument, you do not need to connect it to an amplifier in order to produce sounds. Its onboard amplification system is powerful enough for small venues, restaurants, etc. The FR-1x can also be powered using 8 commercially available rechargeable Ni-MH batteries, so that you dont need to connect it to a wall outlet.

PBM (Physical Behavior Modeling) The FR-1x V-Accordion is based on Rolands sound gen- eration technology called PBM (Physical Behavior Modeling) whose sonic result is very close to the sound of traditional accordions.

Super realistic accordion simulations All sounds the FR-1x produces were obtained by sam- pling popular traditional acoustic accordions. This V-Accordion allows you to switch from an Italian jazz accordion to German folk, French musette or a his- toric bandoneon sound without changing your tech- nique. Different tuning systems are also available.

Orchestral sounds Orchestral sounds can be used in combination with tra- ditional accordion sounds complete with full bellows articulation, and two keyboard modes (Solo and Dual).

Tonewheel organ sounds The FR-1x allows you to play amazing organ sounds with a slow/fast rotary effect in almost the same way as an organ player using the treble section.

Drum sounds You can also use the FR-1x to play simple drum parts with your left hand (bass and chord sections).

Sound expansion The FR-1x provides two internal memories that allow you to add new sounds.

Sophisticated bellows response Faster response and higher sensitivity and precision plus detection of bellows opening/closing with new bellows pressure sensing circuitry. A bellows resistance regulator knob allows you to adjust the bellows inertia to your preference.

USB-based audio player The FR-1x contains an audio player function that allows you to play back mp3 and WAV files directly from a connected USB memory.

Save your settings to a USB memory You can save your settings by connecting an optional USB memory to the FR-1xs USB port.

The digital advantage The V-Accordion includes all functions and sounds of a traditional accordion, thus conveying a truly natural feel and sound. Yet it also provides the advantages only an electronic musical instrument can give you: reduced overall weight; possibility to choose among a wide variety of sounds; various selectable Free Bass modes (Minor 3rd, Bayan,

North Europe, Finnish); tuning stability over time and wear resistance of all

mechanical parts; you can sound in a different key than the one you are

playing in (transpose function); you can play with headphones, i.e. without disturbing

your neighbors or family.

MIDI connection The FR-1x allows you to control external MIDI-compat- ible instruments. The Treble keyboard and chord/bass buttons are velocity-sensitive, while the bellows con- troller provides more articulation possibilities than any other MIDI keyboard, MIDI wind instrument, etc., you may know.

Using the unit safely

V-Accordion

r

FR-1x GB.book Page 7 Tuesday, November 8, 2011 11:44 AM

Using the unit safely

Do not open (or modify in any way) the unit or its AC adaptor.

................................................................................................................................... Do not attempt to repair the unit, or replace parts within

it (except when this manual provides specific instructions directing you to do so). Refer all servicing to your retailer, the nearest Roland Service Center, or an authorized Roland dis- tributor, as listed on the Information page.

................................................................................................................................... Never install the unit in any of the following locations.

Subject to temperature extremes (e.g., direct sunlight in an enclosed vehicle, near a heating duct, on top of heat-generating equipment); or are

Damp (e.g., baths, washrooms, on wet floors); or are

Exposed to steam or smoke; or are

Subject to salt exposure; or are

Humid; or are

Exposed to rain; or are

Dusty or sandy; or are

Subject to high levels of vibration and shakiness. ...................................................................................................................................

Make sure you always have the FR-1x placed so it is level and sure to remain stable. Never place it on stands that could wobble, or on inclined surfaces.

................................................................................................................................... Be sure to use only the AC adaptor supplied with the

unit. Also, make sure the line voltage at the installation matches the input voltage specified on the AC adaptor's body. Other AC adaptors may use a different polarity, or be designed for a different voltage, so their use could result in dam- age, malfunction, or electric shock.

................................................................................................................................... Use only the attached power-supply cord.

Also, the supplied power cord must not be used with any other device.

................................................................................................................................... Do not excessively twist or bend the power cord, or place

heavy objects on it. Doing so can damage the cord, pro- ducing severed elements and short circuits. Damaged cords are fire and shock hazards!

...................................................................................................................................

The FR-1x, either alone or in combination with an ampli- fier and headphones or speakers, may be capable of pro- ducing sound levels that could cause permanent hearing loss. Do not operate for a long period of time at a high volume level, or at a level that is uncomfortable. If you experience any hearing loss or ringing in the ears, you should immediately stop using the unit, and consult an audiologist.

.................................................................................................................................... Do not place containers containing liquid (e.g., flower

vases) on this product. Never allow foreign objects (e.g., flammable objects, coins, wires) or liquids (e.g., water or juice) to enter this product. Doing so may cause short cir- cuits, faulty operation, or other malfunctions.

.................................................................................................................................... Immediately turn the power off, remove the AC adaptor

from the outlet, and request servicing by your retailer, the nearest Roland Service Center, or an authorized Roland distributor, as listed on the Information page when:

The AC adaptor, the power-supply cord, or the plug has been damaged; or

If smoke or unusual odor occurs

Objects have fallen into, or liquid has been spilled onto the unit; or

The unit has been exposed to rain (or otherwise has become wet); or

The unit does not appear to operate normally or exhibits a marked change in performance.

.................................................................................................................................... In households with small children, an adult should pro-

vide supervision until the child is capable of following all the rules essential for the safe operation of the FR-1x.

.................................................................................................................................... Protect the FR-1x from strong impact.

(Do not drop it!)

....................................................................................................................................

Used for instructions intended to alert the user to the risk of injury or material damage should the unit be used improperly.

* Material damage refers to damage or other adverse effects caused with respect to the home and all its furnishings, as well to domestic animals or pets.

Used for instructions intended to alert the user to the risk of death or severe injury should the unit be used improperly.

The symbol alerts the user to things that must be carried out. The specific thing that must be done is indicated by the design contained within the circle. In the case of the symbol at left, it means that the power- cord plug must be unplugged from the outlet.

The symbol alerts the user to important instructions or warnings.The specific meaning of the symbol is determined by the design contained within the triangle. In the case of the symbol at left, it is used for general cautions, warnings, or alerts to danger.

The symbol alerts the user to items that must never be carried out (are forbidden). The specific thing that must not be done is indicated by the design contained within the circle. In the case of the symbol at left, it means that the unit must never be disassembled.

7

Features

8

FR-1x V-Accordion

FR-1x_1_GB.fm Page 8 Tuesday, November 8, 2011 2:56 PM

r

Do not force the FR-1xs power-supply cord to share an outlet with an unreasonable number of other devices. Be especially careful when using extension cordsthe total power used by all devices you have connected to the extension cord's outlet must never exceed the power rating (watts/amperes) for the extension cord. Excessive loads can cause the insulation on the cord to heat up and eventually melt through.

................................................................................................................................... Before using the FR-1x in a foreign country, consult with

your retailer, the nearest Roland Service Center, or an authorized Roland distributor, as listed on the Informa- tion page.

................................................................................................................................... Batteries must never be recharged, heated, taken apart,

or thrown into fire or water.

................................................................................................................................... Never expose batteries to excessive heat such as sun-

shine, fire or the like.

................................................................................................................................... Incorrect handling of batteries, rechargeable batteries, or

a battery charger can cause leakage, overheating, fire, or explosion. Before use, you must read and strictly observe all of the precautions that accompany the batteries, rechargeable batteries, or battery charger. When using rechargeable batteries and a charger, use only the combination of rechargeable batteries and charger specified by the battery manufacturer.

The unit and the AC adaptor should be located so its location or position does not interfere with their proper ventilation.

................................................................................................................................... Always grasp only the plug on the AC adaptor cord when

plugging into, or unplugging from, an outlet or this unit.

................................................................................................................................... At regular intervals, you should unplug the AC adaptor

and clean it by using a dry cloth to wipe all dust and other accumulations away from its prongs. Also, discon- nect the power plug from the power outlet whenever the unit is to remain unused for an extended period of time. Any accumulation of dust between the power plug and the power outlet can result in poor insulation and lead to fire.

................................................................................................................................... Try to prevent cords and cables from becoming entan-

gled. Also, all cords and cables should be placed so they are out of the reach of children.

................................................................................................................................... Never climb on top of, or place heavy objects on the unit.

................................................................................................................................... Never handle the AC adaptor or its plugs with wet hands

when plugging into, or unplugging from, an outlet or this unit.

................................................................................................................................... Before moving the unit, disconnect the AC adaptor and

all cords coming from external devices.

...................................................................................................................................

Before cleaning the unit, turn off the power and unplug the AC adaptor from the outlet (see p. 15).

.................................................................................................................................... Whenever you suspect the possibility of lightning in your

area, disconnect the AC adaptor from the outlet.

.................................................................................................................................... If used improperly, batteries may explode or leak and

cause damage or injury. In the interest of safety, please read and observe the following precautions.

Carefully follow the installation instructions for bat- teries, and make sure you observe the correct polarity.

Avoid using new batteries together with used ones. In addition, avoid mixing different types of batteries.

Remove the batteries whenever the unit is to remain unused for an extended period of time.

If a battery has leaked, use a soft piece of cloth or paper towel to wipe all remnants of the discharge from the battery com- partment. Then install new batteries. To avoid inflammation of the skin, make sure that none of the battery discharge gets onto your hands or skin. Exercise the utmost caution so that none of the discharge gets near your eyes. Immediately rinse the affected area with running water if any of the discharge has entered the eyes.

Never keep batteries together with metallic objects such as ball- point pens, necklaces, hairpins, etc.

.................................................................................................................................... Used batteries must be disposed of in compliance with

whatever regulations for their safe disposal that may be observed in the region in which you live.

.................................................................................................................................... Keep the included button caps in a safe place out of chil-

dren's reach, so there is no chance of them being swal- lowed accidentally.

.................................................................................................................................... Batteries may reach a high temperature: please be care-

ful to avoid burning yourself.

....................................................................................................................................

Important notes

V-Accordion

FR-1x GB.book Page 9 Tuesday, November 8, 2011 11:44 AM

2. Important notes

In addition to the items listed under Using the unit safely on p. 7, please read and observe the following:

Power supply Do not connect this unit to same electrical outlet that is being

used by an electrical appliance that is controlled by an inverter (such as a refrigerator, washing machine, microwave oven, or air conditioner), or that contains a motor. Depending on the way in which the electrical appliance is used, power supply noise may cause this unit to malfunction or may produce audible noise. If it is not practical to use a separate electrical outlet, connect a power supply noise filter between this unit and the electrical outlet.

The AC adaptor will begin to generate heat after long hours of consecutive use. This is normal, and is not a cause for concern.

Before connecting this unit to other devices, turn off the power to all units. This will help prevent malfunctions and/or damage to speakers or other devices.

When installing or replacing batteries, always turn off the power on this unit and disconnect any other devices you may have con- nected. This way, you can prevent malfunctions and/or damage to speakers or other devices.

Placement Using the unit near power amplifiers (or other equipment contain-

ing large power transformers) may induce hum. To alleviate the problem, change the orientation of this unit; or move it farther away from the source of interference.

This device may interfere with radio and television reception. Do not use this device in the vicinity of such receivers.

Noise may be produced if wireless communications devices, such as cell phones, are operated in the vicinity of this unit. Such noise could occur when receiving or initiating a call, or while conversing. Should you experience such problems, you should relocate such wireless devices so they are at a greater distance from this unit, or switch them off.

Do not expose the unit to direct sunlight, place it near devices that radiate heat, leave it inside an enclosed vehicle, or otherwise sub- ject it to temperature extremes. Excessive heat can deform or dis- color the unit.

When moved from one location to another where the temperature and/or humidity is very different, water droplets (condensation) may form inside the unit. Damage or malfunction may result if you attempt to use the unit in this condition. Therefore, before using the unit, you must allow it to stand for several hours, until the condensation has completely evaporated.

Do not allow objects to remain on top of the keyboard. This can be the cause of malfunction, such as keys ceasing to produce sound.

Depending on the material and temperature of the surface on which you place the unit, its rubber feet may discolor or mar the surface. You can place a piece of felt or cloth under the rubber feet to pre- vent this from happening. If you do so, please make sure that the unit will not slip or move accidentally.

Do not put anything that contains water (e.g., flower vases) on this unit. Also, avoid the use of insecticides, perfumes, alcohol, nail pol- ish, spray cans, etc., near the unit. Swiftly wipe away any liquid that spills on the unit using a dry, soft cloth.

Maintenance For everyday cleaning wipe the FR-1x with a soft, dry cloth or one

that has been slightly dampened with water. To remove stubborn dirt, use a mild, non-abrasive detergent. Afterwards, be sure to wipe the instrument thoroughly with a soft, dry cloth.

Never use benzine, thinner, alcohol or solvents of any kind, to avoid the possibility of discoloration and/or deformation.

Repairs and data Please be aware that all data contained in the units memory may

be lost when the unit is sent for repairs. Important data should always be backed up to a USB memory, or written down on paper (when possible). During repairs, due care is taken to avoid the loss of data. However, in certain cases (such as when circuitry related to memory itself is out of order), we regret that it may not be pos- sible to restore the data, and Roland Corporation assumes no lia- bility concerning such loss of data.

Precautions for batteries (not supplied) The temperature range for use of the batteries depends on the

battery type being used. Please see the documentation that came with the batteries.

Do not use or store batteries at high temperature, such as in strong direct sunlight, in cars during hot weather or directly in front of heaters. This may cause battery fluid leakage, impaired performance and shorten the batteries service life.

Do not splash fresh or saltwater on a battery or allow the termi- nals to become damp. This may cause heat generation and forma- tion of rust on the battery and its terminals.

Keep the batteries out of reach of babies or small children.

Do no strike or drop the batteries. Strong impact can cause leak- age of battery fluid, heat generation, bursting or fire.

Do not alter or remove protective mechanisms or other parts. Never disassemble the batteries.

Additional precautions Please be aware that the contents of memory can be irretrievably

lost as a result of a malfunction, or the improper operation of the unit. To protect yourself against the risk of loosing important data, we recommend that you periodically save a backup copy of impor- tant data you have stored inside the unit to a USB memory.

Unfortunately, it may be impossible to restore the contents of data that was stored on a USB memory once it has been lost. Roland Corporation assumes no liability concerning such loss of data.

Use a reasonable amount of care when using the unit's buttons, sliders, or other controls; and when using its jacks and connectors. Rough handling can lead to malfunctions.

Never strike or apply strong pressure to the display.

When connecting/disconnecting all cables, grasp the connector itselfnever pull on the cable. This way you will avoid causing shorts, or damage to the cable's internal elements.

To avoid disturbing your neighbors, try to keep the unit's volume at reasonable levels. You may prefer to use headphones, so you do not need to be concerned about those around you (especially when it is late at night).

When you need to transport the unit, package it in the box (including padding) that it came in, if possible. Otherwise, you will need to use equivalent packaging materials.

Some connection cables contain resistors. Do not use cables that incorporate resistors for connecting to this unit. The use of such cables can cause the sound level to be extremely low, or impossible to hear. For information on cable specifications, contact the man- ufacturer of the cable.

To prevent the inadvertent disruption of power to your unit (should the plug be pulled out accidentally), and to avoid applying undue stress to the jack, secure the power cord using the supplied attachment strip. See p. 20 for details.

9

Important notes

1

FR-1x V-Accordion

FR-1x GB.book Page 10 Tuesday, November 8, 2011 11:44 AM

r Storage devices that can be connected to the FR-1xs USB port The FR-1x allows you to connect commercially available USB

memories. You can purchase such devices at a computer store, a digital camera dealer, etc.

Use USB memory sold by Roland (M-UF series). We cannot guaran- tee operation if any other USB memory is used.

Before using external USB memories When connecting a USB memory, carefully insert it all the way

into the FR-1xs USB port.

Do not touch the pins of the FR-1xs USB port or allow them to become dirty.

Never insert or remove a USB memory while this units power is on. Doing so may corrupt the units data or the data on the USB memory.

USB memories are constructed using precision components; han- dle the storage devices carefully, paying particular note to the fol- lowing.

To prevent damage from static electrical charges, discharge any static electricity that might be present in your body before han- dling a USB memory.

Do not touch the terminals with your fingers or any metal object.

Do not bend or drop a USB memory, or subject it to strong impact.

Do not leave a USB memory in direct sunlight or in locations such as a closed-up automobile.

Do not allow a USB memory to become wet.

Do not disassemble or modify your external USB memory.

When connecting a USB memory, position it horizontally with the FR-1xs USB port and insert it without using excessive force. The USB port may be damaged if you use excessive force when insert- ing a USB memory.

Do not insert anything other than a USB memory (e.g., wire, coins, other types of device) into the USB port. Doing so will damage the FR-1xs USB port.

Never connect your USB memory to the FR-1x via a USB hub.

Notice MPEG Layer-3 audio compression technology is licensed from

Fraunhofer IIS Corporation and THOMSON Multimedia Corpora- tion.

Roland and V-Accordion are either registered trademarks or trade- marks of Roland Corporation in the United States and/or other countries.

MMP (Moore Microprocessor Portfolio) refers to a patent portfolio concerned with microprocessor architecture, which was developed by Technology Properties Limited (TPL). Roland has licensed this technology from the TPL Group.

Company and product names appearing in this document are trademarks or registered trademarks of their respective owners.

0

A rst look at your FR-1x V-Accordion r

FR-1x GB.book Page 11 Tuesday, November 8, 2011 11:44 AM

3. A first look at your FR-1x

Let us first take a look at how the FR-1x is organized and how it is operated.

The sections of your FR-1x Lets briefly look at the various sections of your instrument, as that will help you understand how your V-Accordion works.

Treble section (right-hand manual) This section is normally used for playing the melody. The FR-1xs treble section is velocity sensitive.

Bass and chord section This section is normally used to play the accompani- ment. There are two general categories: one is called Stradella, and the other Free Bass. The FR-1x allows you to use either type. The Stradella system, also called the standard bass system uses the first 2 (or 3) button rows to play bass notes. The remaining button rows are used to play chords. If you select the Free Bass system, all buttons are used to play single bass notes. The FR-1xs bass and chord section is velocity sensi- tive.

Bellows The bellows is an important part of the accordion. The movement of the bellows indeed lends expres- sion and dynamics to the sound. Several techniques are available, one of which is called bellows shake (rapid opening and closing movements). The bellows inertia can be set with the resistance regulator and air button.

Bellows resistance regulator Your FR-1x is equipped with a bellows resistance regu- lator and an air button located next to one of the bel- lows clips.

The air button allows you to release remaining air from the bellows without producing sound. Press the wheel and rotate it clockwise to select a

stronger inertia. Press the wheel and rotate it counterclockwise to

select a lighter inertia. Press the air button to purge the remaining air from

the bellows after closing it.

Treble section

Bass and chord section

Bellows

Bellows resistance regulator. Press and turn to select the bellows resistance.

Air button. Press to purge remaining air after playing.

11

Panel descriptions

1

FR-1x V-Accordion

A

J

K

L

M

FR-1x GB.book Page 12 Tuesday, November 8, 2011 11:44 AM

r 4. Panel descriptions

Treble control panel

A USB MEMORY port The FR-1xs USB port allows you to connect an optional USB memory. It can be used to save and load User Programs as well as to load User Sets and new sounds.

NOTE

Use USB memory sold by Roland (M-UF series). We cannot guarantee operation if any other USB memory is used.

B ORCHESTRAL BASS button This button activates the orchestral section for the bass buttons, allowing you to play the bass notes using an orchestral sound instead of an accordion sound.

C ORCHESTRAL CHORD/FREE BASS button This button activates the orchestral section for the chord buttons, allowing you to play chords using an orchestral sound instead of an accordion sound. When the FREE BASS section is active, this button activates the orchestral section for the Free Bass sec- tion.

D LEFT HAND FREE BASS button Press this button if you want to use all buttons in the left hand to play bass notes (in which case no chords are available). Press and hold this button to check the state of the batteries you installed.

E LEFT HAND DRUMS button Allows you to add drum/percussion sounds to the bass and chord section.

F SET register This register is used to recall one of 16 Sets from one of the 4 Set families: press the [SET] register and one of the 4 treble registers. The [SET] register has additional functions:

To edit function and MIDI parameters: press and hold [SET].

To change octaves: press [SET] and [1/OCT] or [2/ OCT+].

To activate the metronome: press [SET] and then tre- ble register [3/(METRON)].

To alternate between Dual and Solo modes: press [SET] and then treble register [4/(DUAL/SOLO)].

G Treble registers The treble section contains 4 registers that allow you to select accordion, orchestral and organ sounds, Sets and User Programs.

NOTE

By pressing and holding any register, you can switch off the treble or Treble Orchestra and Organ sections. Press another register to switch it back on.

H USER PROGRAM/ENTER button This button is used to recall one of the 8 User Pro- gram memories: first press [USER PROGRAM] and then one of the treble registers. See page 38. It is also used to confirm settings and commands.

I PLAYER buttons These buttons are used to operate the FR-1xs built-in USB player. [] allows you to return to the beginning of the current song. [] is used to start and pause playback of the selected song.

D E F H IG

B C

2

Bass control panel V-Accordion

FR-1x GB.book Page 13 Tuesday, November 8, 2011 11:44 AM

J RIGHT HAND ORCHESTRA button This button activates the orchestral section for the right hand (treble). Press it together with the [ORGAN] button to select the FR-1xs demo function.

K RIGHT HAND ORGAN button This button activates the organ section for the right hand (treble). Press it together with the [ORCHESTRA] button to select the FR-1xs demo function.

L POWER button Press this button to switch the V-Accordion on (the button lights) and off (button dark).

NOTE

If you need to turn off the power completely (when using the supplied AC adaptor), first turn off the [POWER] button, then disconnect the AC adaptors plug from the wall outlet.

NOTE

With the factory settings, the FR-1xs power will automati- cally be switched off 10 minutes after you stop playing or operating the FR-1x. If the units power has been turned off automatically, you can use the [Power] switch to turn the unit back on again. If you dont want the power to turn off automatically, change the Auto Off setting to Off as described on page 55.

M VOLUME knob This knob allows you to set the V-Accordions overall volume.

Bass control panel

N Bass registers These registers allow you to select the desired bass sound.

NOTE

By pressing and holding any register, you can switch off the Bass/Chord (or Free Bass) section. Press another register to switch it back on.

O Bass and chord buttons These 72 buttons are used to play bass notes and chords (they are velocity-sensitive). They also allow you to play drum sounds.

P Bellows resistance regulator and air button This wheel allows you to specify the bellows inertia (the force needed to push and pull it). See page 11. By pressing it you can purge the air that still remains in the bellows after playing.

Q Display The display keeps you informed about the FR-1xs status and helps you locate the functions you may wish to set.

N

O P

Q

13

Panel descriptions

1

FR-1x V-Accordion

FR-1x GB.book Page 14 Tuesday, November 8, 2011 11:44 AM

r Battery compartment

Connection panel

S DC IN socket This is where you need to connect the supplied power adapter (PSB-1U). Note that you can also purchase 8 rechargeable AA-type Ni-MH batteries and use the FR-1x without the adapter.

T MIDI OUT socket This socket can be used to transmit MIDI data.

U USB COMPUTER port This port can be connected to one of your computers USB ports (see p. 63). Please use a commercially available USB cable.

V OUTPUT L/MONO (TREBLE) & R/MONO (BASS) sockets These sockets can be connected to an amplifier, a mixing console or a commercially available wireless system. If you use both connectors, the FR-1xs out- put is stereo. In that case the signals of the Treble section are transmitted to the L/MONO socket, while the R/MONO socket transmits the bass (and chord) signal. If you only use one jack (connected to the L or R socket), the FR-1xs output is mono.

NOTE

On the FR-1x, connecting jacks to these sockets does not mute the internal speakers.

NOTE

Using these sockets and switching off the FR-1xs speakers (see Speaker Mode on p. 55) allows you to save battery power.

W PHONES socket This is where you can connect stereo headphones (Roland RH-series).

NOTE

Connecting a pair of headphones mutes the internal speak- ers.

R

R Battery compartment This is where you install 8 commercially available rechargeable AA-type Ni-MH batteries (see p. 16).

TS U V W

4

Before you start playing V-Accordion

FR-1x GB.book Page 15 Tuesday, November 8, 2011 11:44 AM

5. Before you start playing

Getting ready to play The FR-1x is an electronic instrument that requires some form of electrical power. This chapter explains how to power your FR-1x using the supplied adaptor or 8 commercially available rechargeable batteries (AA- type Ni-MH). In addition, you will learn how to connect your FR-1x to an external amplification system.

Connecting the AC adaptor NOTE

To prevent malfunction and/or damage to speakers or other devices, always turn down the volume, and turn off the power on all devices before making any connections.

1. Turn the [VOLUME] knob all the way towards the small dot to minimize the vol- ume.

2. Connect the included power cord to the AC adapter. The indicator will light once you plug the AC adapter into a wall outlet.

Place the AC adaptor so the side with the indicator (see illustration) faces upwards and the side with tex- tual information faces downwards.

NOTE

Depending on your region, the included power cord may differ from the one shown above.

NOTE

Be sure to use only the AC adaptor supplied with the unit (PSB-1U). Also, make sure the line voltage at the installa- tion matches the input voltage specified on the AC adap- tors body. Other AC adaptors may use a different polarity, or be designed for a different voltage, so their use could result in damage, malfunction, or electric shock.

3. Connect the AC adaptor to the FR-1xs DC IN jack.

4. Plug the power cord into a power outlet. Now that the FR-1x is connected to a wall outlet, you can continue with the section Switching the power on and off on p. 21. To use the FR-1x with batteries, see Installing and removing batteries on p. 16.

NOTE

If the FR-1x is to remain unused for an extended period of time, unplug the adaptor.

NOTE

To prevent the inadvertent disruption of power to your unit (should the plug be pulled out accidentally), and to avoid applying undue stress to the AC adaptor jack, anchor the power cord. See Securing the adapter and/or MIDI cable on p. 20.To the FR-1xs DC IN connector

AC adaptor Power cord

To a AC outlet

Indicator

To a wall outlet

15

Before you start playing

1

FR-1x V-Accordion

FR-1x GB.book Page 16 Tuesday, November 8, 2011 11:44 AM

r Installing and removing batteries The FR-1x has a compartment into which you can install 8 commercially available AA-type Ni-MH batter- ies (which are rechargeable). You can therefore play your instrument without connecting the supplied adaptor.

1. Switch off the FR-1x.

2. Remove the cover from the FR-1xs battery compartment by pressing the two tabs and lifting the cover.

3. Insert 8 rechargeable AA-type Ni-MH bat- teries into the compartment (4 on either side), taking care to orient them in accor- dance with the + and indications.

4. Close the FR-1xs battery compartment.

NOTE

Though it is perfectly possible to use rechargeable batter- ies, be aware that they cannot be recharged simply by leav- ing them in the FR-1xs compartment and connecting the adapter. You will need an external charging unit.

NOTE

When replacing batteries, be sure to insert them correctly (ensure correct polarity).

NOTE

Remove the batteries whenever the FR-1x is to remain unused for an extended period of time.

Battery charge indication If, while using batteries, the bAt message appears in the display, the remaining battery power is low. Replace the batteries at your earliest convenience. A flashing bAt message means that you need to replace the batteries right away (or use the supplied adaptor). The FR-1x also allows you to check the remaining battery charge at any time:

1. Press and hold the [FREE BASS] (BATTERY) button.

The FR-1xs display now shows the battery status.

ooo means that the charge is still at the maximum level, oo refers to a medium level, and o to a low charge level. If the o starts flashing, you need to replace or recharge the batteries. If the message AdP is displayed, the FR-1x is powered by the sup- plied adaptor.

NOTE

The battery charge indication is only an approximation.

Battery duration New or fully charged batteries should last about 8 hours (for 2000mAh Ni-MH batteries) during contin- uous operation while the internal speakers are off (see Speaker Mode on p. 55), or 5 hours while the speakers are on.

NOTE

Actual battery life varies according to usage conditions, the quality of the batteries and the number of charging cycles.

NOTE

While the adaptor is connected to the DC IN socket with- out being connected to a wall outlet, the FR-1x cannot be switched on, regardless of whether or not it contains bat- teries.

Note about rechargeable batteries Certain batteries can be recharged several times before they need to be replaced with new ones. Note that it is normal for the batteries to last increasingly shorter as time goes by. At the end of their life cycle, they may only last one hour, for example. But that is a gradual process.

NOTE

Though it is perfectly possible to use rechargeable batter- ies, be aware that they cannot be recharged simply by leav- ing them in the FR-1xs compartment and connecting the adapter. You will need an external charging unit.

NOTE

We recommend using rechargeable AA-type Ni-MH batter- ies.

ooo

6

Energy saving function V-Accordion r

FR-1x GB.book Page 17 Tuesday, November 8, 2011 11:44 AM

Energy saving function Connecting the FR-1x to an amplifier, mixer, etc. The FR-1x is equipped with an internal speaker system and thus does not need to be connected to an amplifier at all. There may be times, however when using an external amplification system is more convenient.

NOTE

If you are using optional batteries and need to connect the FR-1x to a PA system or mixer, we recommend using a com- mercially available wireless system to avoid having to use excessively long signal cables.

NOTE

To prevent malfunction and/or damage to speakers or other devices, always turn down the volume, and turn off the power on all devices before making any connections.

1. Turn the [VOLUME] knob all the way towards the small dot to minimize the vol- ume.

2. Switch off all devices.

3. Connect the FR-1xs OUTPUT jacks to the inputs of your external device.

Please choose unbalanced (mono) cables with 1/4 jacks at one end (for the FR-1x). The connectors at the other end need to match the input sockets of the device to which you are connecting the FR-1x.

NOTE

If you use a commercially available wireless transmitter, the FR-1xs output signals may distort. In that case, change the FR-1xs output level (see Output Level Attenuation on p. 55).

NOTE

If your amplifier is monaural, you only need to connect the L/MONO (or R/MONO) socket.

NOTE

This unit has an Auto Off function, which auto- matically switches off the power after a certain amount of time has passed without any buttons being operated. One minute before the FR-1x shuts down automati- cally, the display starts counting down the seconds. If you want to keep using the FR-1x at this stage, press any button or register. You can also disable the Auto Off function. For more about the Auto Off function, refer to Auto Off on p. 55.

OUTPUT L/MONO (Treble) + R/MONO (Bass)

INPUT L + R

Use either a long signal cable (10m or more) or an optional wireless system (recommended).

17

Before you start playing

1

FR-1x V-Accordion

FR-1x GB.book Page 18 Tuesday, November 8, 2011 11:44 AM

r

After connecting any cable to the FR-1x, be sure to never place it on the side when not using it.

Always stand the V-Accordion on its rubber feet (and in the corresponding direction) to avoid damaging the plugs.

Always handle and move the FR-1x with care and pay special attention to the cable slack to avoid damaging or bending the cables.

If you place the FR-1x on your lap, ensure that the audio and adapter cables run between your legs (not sideways) to avoid damaging or bending the cables.

Attaching the straps Proceed as follows to attach the straps to your FR-1x:

1. Unpack the straps. The FR-1x comes with two straps, each with two ends: the upper end is fitted with a Velcro strip and the clip, the lower end is not. See the illustration below:

2. Put the FR-1x on a stable surface as shown in the illustration below.

3. Slide the upper end (with the Velcro strip) of one strap through the left holder ring (see the illustration).

4. Attach the straps upper part to the Velcro layer below it.

Important remark

Left holder ring

8

Bass strap V-Accordion r

FR-1x GB.book Page 19 Tuesday, November 8, 2011 11:44 AM

5. Close the security clip to ensure that the strap cannot come loose.

6. Repeat steps (3)~(5) for the other strap. The upper strap ends should look as follows:

7. Slide the lower end of one strap through the right holder ring as shown.

8. Slide the strap end through the upper eyelet of its plastic buckle (see the illustration).

9. Turn the strap end around and insert it into the lower eyelet, then pull it tight.

NOTE

You may want to adjust the length first to suit your prefer- ence.

10. Slide the plastic clip over the loose and long lower strap ends to secure the strap.

11. Repeat steps (7)~(9) for the other lower strap end.

Bass strap The FR-1xs bass strap (used to move the bellows in and out) is made of fabric and fitted with a Velcro strip that allows you to adjust its slack.

19

Before you start playing

2

FR-1x V-Accordion

FR-1x GB.book Page 20 Tuesday, November 8, 2011 11:44 AM

r Securing the adapter and/or MIDI cable Proceed as follows to ensure that the adapter cable or a MIDI cable doesnt come loose while you are play- ing.

Your FR-1x comes with an adapter and an attachment strip that allows you to secure the adapter cable and optional MIDI as well as audio cables to the right strap.

1. Prepare the adapter cable and the attach- ment strip as follows:

Be sure to attach the strip before the ferrite core on the adapter cable. If you like, you can also add the MIDI cable and audio cables to this assembly.

2. Secure the attachment strip as shown in the illustration, making sure that the ferrite core cannot slide out of the loop.

3. Hold the adapter cable close to the right strap and wind the attachment strip around it as shown.

The strip is fitted with a Velcro layer that holds it in place.

4. Keep winding the attachment strip around the strap until your assembly looks as fol- lows:

5. Reverse these steps to remove and discon- nect the adapter and/or MIDI and audio cables when you want to stop playing.

Ferrite core

0

Switching the power on and off V-Accordion

FR-1x GB.book Page 21 Tuesday, November 8, 2011 11:44 AM

Switching the power on and off NOTE

Once the connections have been completed, turn on power to your various devices in the order specified. By turning on devices in the wrong order, you risk causing malfunction and/ or damage to speakers and other devices.

NOTE

Always make sure the volume is turned down before switch- ing on the power. Even with the volume all the way down, you may still hear some sound when the FR-1x is switched on, but this is normal and does not indicate a malfunction.

Turning on the power 1. Turn the [VOLUME] knob all the way

towards the small dot to minimize the vol- ume. If you connected the FR-1x to an amplifier, etc., set its volume to the minimum value as well.

2. To switch the FR-1x on, press the [POWER] button. The [POWER] button lights.

NOTE

This unit is equipped with a protection circuit. A brief inter- val (a few seconds) after power up is required before the unit will operate normally.

3. Turn the [VOLUME] knob clockwise to set the volume to an appropriate level.

4. Adjust the volume of the receiving audio device (if connected).

Turning off the power 1. Turn the [VOLUME] knob all the way

towards the small dot to minimize the vol- ume. If you connected the FR-1x to an amplifier, etc., set its volume to the minimum value as well.

2. Press the FR-1xs [POWER] button (its indi- cator goes dark).

Using headphones The FR-1x has one jack for plugging in headphones. This allows you to play without having to worry about bothering others around you, even at night.

1. Plug the headphones into the [PHONES] jack located on the FR-1xs connection panel.

NOTE

Use stereo headphones. Please use only Roland head- phones. Headphones from other manufacturers may be unable to provide sufficient volume.

NOTE

The FR-1xs speakers are switched off when you connect headphones. In that case, the SPEAKER OFF indicator lights. See also How to read the display on p. 22.

2. Use the FR-1xs [VOLUME] knob to adjust the headphone volume.

NOTE This unit has a function that automatically switches off the power after a certain amount of time has passed without any buttons being operated. You can disable this function. See Auto Off on p. 55.

21

Before you start playing

2

FR-1x V-Accordion

FR-1x GB.book Page 22 Tuesday, November 8, 2011 11:44 AM

r Cautions when using headphones To prevent damage to the cords internal conductors,

avoid rough handling. When using headphones, mainly try to handle either the plug or the headset.

Your headphones may be damaged if the volume of a device is already turned up when you plug them in. Minimize the volume before you plug in the head- phones.

Excessive input will not only damage your hearing, but may also strain the headphones. Please enjoy music at an appropriate volume.

How to read the display The FR-1xs display keeps you informed about the FR-1xs status and helps you locate functions you may wish to set. The display can show up to three alphanu- meric characters, either with or without a dot. The main page contains the following information:

A dot to the right of a digit has the following meaning:

In addition to the above, the display also shows infor- mation that refers to the selected function. Messages (information) are displayed only temporarily. There are also two indicators below the display that serve the following purposes:

Digit Explanation

First Refers to the bass register you are currently using.

Second The digit in the middle refers to the Chord/Free Bass register you are currently using.

Third Refers to the treble register you are currently using.

Status Explanation

Dark You are using an accordion sound.

Lit You are using an orchestral sound.

Flashes You are using an organ sound. (Only in the Tre- ble section.)

Indicator Explanation

USER PRG Lights when you select User Program mode (see p. 37).

SPEAKER OFF Lights when the internal speakers are off. This state can be selected using a PARAMETER function (see Speaker Mode on p. 55) or simply by connecting a jack to the PHONES socket.

423.

2

Listening to the demo songs V-Accordion r

FR-1x GB.book Page 23 Tuesday, November 8, 2011 11:44 AM

6. Listening to the demo songs

The FR-1x contains several demo songs. Here is how to play back those demo songs and fully appreciate the sounds con- tained in the FR-1x.

1. Switch on the FR-1x. See Switching the power on and off on p. 21.

2. Simultaneously press the [ORCHESTRA] and [ORGAN] buttons until the display looks as follows:

Playback starts automatically with the first demo song (there are 8 demo songs in all). At the end of the first song, the FR-1x starts playing songs 2, 3 etc.

You can also directly jump to the song youre inter- ested in:

3. Use treble registers [1] and [2] (VALUE ) to select the demo song you want to listen to.

4. Use the [VOLUME] knob to change the vol- ume if it is too loud or too soft.

5. Press [ORCHESTRA] and [ORGAN] again to leave demo song mode.

NOTE

During demo song playback, the FR-1xs keyboards cannot be used.

NOTE

No data for the music that is played back will be output from the MIDI OUT socket or USB COMPUTER port.

The following demo songs are available:

NOTE

All rights reserved. Unauthorized use of this material for purposes other than private, personal enjoyment is a violation of applicable laws.

d01

No. Song title Performed by

1 Forro de Janeiro Ludovic Beier

2 Tango Dancers Ludovic Beier

3 Sax on the Phone Ludovic Beier

4 Sotto i ponti della Senna Ludovic Beier

5 Funky Night Ludovic Beier

6 Passionate Red Rose Sergio Scappini

7 Carnival in Venice (traditional) Sergio Scappini

8 Sonata in C Maj. by D. Scarlatti Sergio Scappini

23

Using Sets

2

FR-1x V-Accordion

FR-1x GB.book Page 24 Tuesday, November 8, 2011 11:44 AM

r 7. Using Sets

The FR-1x is a virtual accordion. It recreates the sounds of various accordion instruments and can even generate orchestral sounds (like trumpet, flute, etc.), organ and drum sounds.

Recalling a Set is similar to switching to a different accordion.

The FR-1x contains 16 Sets divided over 4 families. All Set families have been programmed at the factory (CLASSIC, JAZZ, WORLD and USER, see the leg- ends above the treble registers). The USER family can be used to load User Sets from an optional USB mem- ory. Each Set family comprises 4 Sets (see below). Recalling a Set immediately changes the settings of the sections presented on p. 26 and configures the treble and bass registers.

Selecting Sets To select the desired Set, proceed as follows:

1. Press the [SET] register.

The number of the selected Set flashes in the display. The first digit from the left refers to the Set family, the second to the Set memory within that family. If, after pressing [SET] once, you do not press a treble register, the display returns to the main page after a while. In that case, press [SET] again and proceed with step 2.

NOTE

If you hold down [SET] for more than 2 seconds without pressing another register, the FR-1x switches to PARAME- TER mode. In that case, press [SET] again to leave that mode, then repeat step (1).

2. Press one of the treble registers [1]~[4] to select the Set family.

Set selection is handled in the following way: If the Set family you select is the same as the one you

have been using so far, the FR-1x selects the next Set within that family. Example: Pressing [1] CLASSIC while the display shows 11 selects Set memory 12 (still within the CLASSIC family).

Treble register

[1] CLASSIC [2] JAZZ

11 Concerto 12 Classic 13 Bajan 14 I Scala

21 Jazz 22 FJazz 23 Bandoneon 24 Studio

Treble register

[3] WORLD [4] USER

31 I Folk 32 F Folk 33 D Folk 34 SP Folk

U1 Alpine U2 Cajun U3 Tex Mex U4 Scottish

Treble 1~14

Bass & Chord 1~7

Orchestra 1~16

Orch. Bass 1~7

Orch. Chord 1~7

Orch FB 1~7

Free Bass 1~7

User Set 16

Set 3 Set 2 Set 1

GLOBAL Metronome

Reverb Chorus Level Touch

::

Organ 1~4

Most of these set- tings can be saved.

11

12

4

Selecting Sets V-Accordion r

FR-1x GB.book Page 25 Tuesday, November 8, 2011 11:44 AM

To go from Set 11 to Set 14, you therefore need to press register [1] three times after pressing [SET].

If you select a different Set family, the FR-1x switches to the newly selected Set family and recalls the last memory you selected within that family.

NOTE

For the User Set memories, the display shows a U. There are four User Sets.

NOTE

While the USER PRG indicator below the display lights, it is impossible to select Sets. In order to select a Set, you will have to press the [USER PROGRAM] button to leave User Program mode.

25

Selecting and playing sounds

2

FR-1x V-Accordion

FR-1x GB.book Page 26 Tuesday, November 8, 2011 11:44 AM

r 8. Selecting and playing sounds

Treble section The treble section can be played using the 26-key piano keyboard or the 62 treble buttons. The sound it produces is deter- mined by the treble register [1]~ [4] you pressed last. This section can be used to play accordion, orchestral and organ sounds.

Selecting sounds for the right hand This section explains how to select accordion, orchestral and organ sounds for the treble section (right hand). On p. 27, you will learn how to combine accordion notes with an orchestral or organ sound. Sounds are selected using treble registers [1]~[4]. To select an orchestral or organ sound, you first need to press the [ORCHESTRA] or [ORGAN] button, and then a treble register.

1. Switch on the FR-1x. See Switching the power on and off on p. 21.

2. If you wish to select a treble accordion reg- ister, skip to step 4.

NOTE

After switching on the FR-1x, the treble registers select accordion sounds.

3. Press the [ORCHESTRA] or [ORGAN] button to activate the orchestral or organ section.

(If you press [ORCHESTRA] or [ORGAN] again at this stage, the treble registers once again allow you to select accordion sounds.)

The number of the last sound you selected for that group (orchestra or organ) is indicated by the right- most digit in the display.

In some cases, the display shows a dot to the right of the treble register number. Here is what that means:

4. Press one of the treble registers ([1]~[4]) to select the desired sound. The rightmost digit in the display changes and indi- cates the number of the sound you have just selected.

5. Play a few notes to audition the sound (accordion, orchestral or organ). Do not forget to move the bellows in order to hear the notes you are playing. If you did not select the correct sound family, return to step 3.

Additional information about the accordion section The FR-1x allows you to select among 14 accordion sounds (even though there are only 4 treble registers). Pressing register [1], [2] or [3] repeatedly selects one of the four available sounds (a~d, see the table below). Register [4] provides access to two sounds (a and b). The following accordion sounds are available:

Example: To go from sound 1a to sound 1c, you need to press treble register [1] twice.

Dot status Explanation

Dark You are using an accordion sound.

Lit You are using an orchestral sound.

Flashes You are using an organ sound.

Treble registers

1 2 3 4

a Bassoon Master Clarinet Piccolo

b Bandon Organ Musette Oboe

c Cello Accord Celeste

d Harmon Violin Tremolo

223.

6

Additional information about the orchestral section V-Accordion

FR-1x GB.book Page 27 Tuesday, November 8, 2011 11:44 AM

When you select Set 32, F Folk, the footages change as follows:

Additional information about the orchestral section The [ORCHESTRA] button allows you to use treble regis- ters [1]~[4] to select from among 16 different orches- tral sounds:

Each time you press a treble register [1]~[4], you select the next sound (always starting from a the first time the register is pressed). Example: To go from sound 2a to sound 2d, you need to press treble register [2] three times.

NOTE

The dynamics of sounds marked with an asterisk (*) can only be controlled by bellows movements. Those sounds are not velocity sensitive. The dynamics of sounds marked with a double asterisk (**) can be controlled by bellows move- ments and playing velocity. For the other sounds, see also Orchestra Bass/Chord Touch on p. 48.

Additional information about the organ sounds and the Rotary effect (organ section) The FR-1x allows you to recall 4 organ sounds with tre- ble registers [1]~[4]. Pressing the register of the selected organ sound again allows you to switch between the slow (SLo) and fast (FSt) speeds of the Rotary effect. The display briefly shows which one is selected.

The FR-1x contains the following organ sounds:

NOTE

The organ sounds can only be controlled with bellows movements.

Switching off the treble section 1. To switch off the treble section, press and

hold any single register ([1]~[4]) for a while. The section in question must be assigned to the reg- isters. See above for how to decide which section can be muted.

2. To switch the treble section back on, briefly press any of its registers.

NOTE

This only switches off the section that is currently selected. Remember that the treble section can control both an accordion and an orchestral or organ sound. While in Orchestra mode, you thus only switch off (or activate) the orchestral/organ section. And while in accordion mode, you only switch off the treble accordion section.

NOTE

Even if you switch off the treble section, it still transmits MIDI messages.

SOLO and DUAL The orchestral or organ sound assigned to the treble section can be played in isolation or together with the treble accordion sound.

1. Select an orchestral or organ sound. See Selecting sounds for the right hand on p. 26.

2. Hold down the [SET] register and press tre- ble register [4] (DUAL/SOLO) to alternate between DUAL and SOLO modes.

NOTE

If you hold down [SET] for more than 2 seconds without pressing another register, the FR-1x switches to PARAME- TER mode. In that case, press [SET] again to leave that mode, then repeat step (1) above.

Treble registers (F Folk set)

1 ENSEMBLE 2 BRASS

a Basson Tsigane

b JazzA Concerto

c ArnoldX 4 Voix

d JazzX! Violon

3 WIND 4 PIANO/GUITAR

a SW Valse Piccolo

b Star 10 Mr Gus

c Pro 8M

d SOS Musette

Treble registers (ORCHESTRA)

1 ENSEMBLE 2 BRASS 3 WIND 4 PIANO/ GUITAR

a Strings* Twin Trump* Flute 1* Ac Piano

b Jazz Scat 1** Trombone* Tenor Sax 2* Ac Guitar

c Jazz Doos* French Horn* Clarinet 1* Mandolin

d Str &Choir* Brass* Oboe* HarpsStr

Treble registers (ORGAN)

1 2 3 4

Jazz Latin HousPerc Theatre

PIANO/GUITAR

27

Selecting and playing sounds

28

r

FR-1x V-Accordion

FR-1x_1_GB.fm Page 28 Tuesday, November 8, 2011 12:04 PM

In SOLO mode, the treble keyboard only plays the selected accordion, orchestral or organ sound. DUAL mode means that the orchestral or organ sound is added to the treble accordion sound.

NOTE

You can change the volume level of the orchestral or organ sound to create the desired mix between the treble accor- dion and the organ or orchestral sound. See Orchestra Level on p. 46 or Organ Level on p. 46.

Transposing the treble section in octave steps There may be times when you need to play higher or lower notes than the piano or button keyboard allows. Unlike an acoustic accordion, the FR-1x allows you to transpose the piano or button keyboard one octave up or down. An additional advantage of this functionality is that you can play the selected orchestral or organ sound in a different octave in DUAL mode (see SOLO and DUAL).

1. To transpose one octave down, hold down the [SET] register and press treble register [1] (OCT).

NOTE

If you hold down [SET] for more than 2 seconds without pressing another register, the FR-1x switches to PARAME- TER mode. In that case, press [SET] again to leave that mode, then repeat step (1).

2. To transpose one octave up, hold down the [SET] register and press treble register [2] (OCT+). The display briefly confirms your setting:

NOTE

The transposition function does not apply to Bass-to-Treble mode (see Bass to Treble on p. 53).

Bass and chord section The Bass section can be played via the Stradella but- tons.

The buttons in this section allow you to play both bass notes and chords. The real bass notes are assigned to the two highlighted rows. The remaining buttons are used to play chords. The FR-1x is supplied with several reference caps (con- cave and with lines) to help you locate the bass and chord buttons without looking at them. At the factory, three caps are installed on the buttons in the following illustration. Feel free to remove them and to slide them over other buttons if that feels more comfortable.

Here is what the caps look like:

The overall sound the bass and chord section produces is determined by the register you pressed last. The bass and chord section can be used to play accordion or orchestral sounds.

Selecting accordion sounds for the left hand Here is how to select an accordion sound for the bass and chord section (left hand). Accordion sounds for the left hand can be selected using the 3 registers shown below.

NOTE

The numbers shown in the illustrations above and below do not appear on the registers themselves. They have been added for your reference.

Sol dVA

SOLO mode DUAL mode

UP Dn

One octave up One octave down

---

No octave transposition

Chord buttons*

(*) This can be changed to 3 bass and 3 chord rows. See Bass & Chord Mode on p. 53.

F3

C#3

C#M

C#m

C#7

C#dim Abdim Ebdim Bbdim Fdim Cdim Gdim Ddim Adim Edim Bdim F#dim

Ab7 Eb7 Bb7 F7 C7 G7 D7 A7 E7 B7 F#7

Abm Ebm Bbm Fm Cm Gm Dm Am Em Bm F#m

AbM EbM BbM FM CM GM DM AM EM BM F#M

Ab3 Eb3 Bb3 F3 C3 G3 D3 A3 E3 B3 F#3

C3 G3 D3 A3 E3 B3 F#3 C#3 Ab3 Eb3 Bb3

Bsss buttons

Slide up to remove

Slide over button

Reference cap

[3] [2] [1]

Selecting orchestral sounds for the left hand

V-Accordion

FR-1x_1_GB.fm Page 29 Tuesday, November 8, 2011 12:02 PM

1. Switch on the FR-1x. See Switching the power on and off on p. 21.

NOTE

After switching on the FR-1x, the bass registers select accordion sounds.

2. Press one of the 3 bass registers (1~3) to select the desired sound. The display shows the number of the selected sound in the BASS and CHORD/FREE BS columns. This choice always applies to both the bass and the chord rows. The following accordion sounds can be selected for the bass and chord buttons:

Note that registers 1 and 2 allow you to select two sounds, while register 3 provides access to three sounds. You may therefore have to press the register in question repeatedly.

Selecting orchestral sounds for the left hand Here is how to select an orchestral sound for the left hand. While the bass and chord accordion sections always use the same accordion sound, orchestral sounds can be assigned to only the bass buttons, only the chord buttons, or both (in which case you can select different orchestral sounds for the bass and chord rows).

1. Switch on the FR-1x. See Switching the power on and off on p. 21.

2. Do one of the following: To select an orchestral sound for the bass rows,

press the ORCHESTRAL [BASS] button.

NOTE

If you prefer to assign an accordion sound to the bass rows (bass section) at this stage, again press the [BASS] button.

To select an orchestral sound for the chord rows, press the ORCHESTRAL [CHORD/FREE BASS] button.

The last sound you selected for the section in ques- tion is recalled and its number is displayed in the BASS (left) or CHORD/FREE BS (middle) column of the display. If you select an orchestral sound, the digit in ques- tion is displayed with a dot to its right:

NOTE

If you prefer to assign an accordion sound to the chord rows (chord section) at this stage, again press the [CHORD/ FREE BASS] button.

3. Press one of the 3 bass registers to select the desired sound. The display shows the number of the selected orches- tral sound in the BASS or CHORD/FREE BS column (see the examples above). The following sounds can be selected for the bass or chord buttons:

Bass & chord registers

1 2 3

a 8/4/2 16/8/8-4/4/2 16/2

b 8-4 16/8/8-4 4

c 2

Orchestral bass sounds [BASS]

1 2 3

a Acoustic Bowed* Tuba Mix

b Fingered Jazz Pedal VTW* Tuba*

c Fretless

Orchestral chord sounds [CHORD/FREE BASS]

1 2 3

a St. Strings* Jazz VTW* Steel Gtr

b Jazz Doos* R&B VTW* Ac Guitar

c Ac Piano

443 423.

The bass and chord buttons use an accordion sound (no dots).

The bass buttons use an accordion sound (no dot). The chord buttons

use an orchestral sound (dot).

[3] [2] [1]

29

Selecting and playing sounds

3

FR-1x V-Accordion

FR-1x GB.book Page 30 Tuesday, November 8, 2011 11:44 AM

r Note that registers 1 and 2 allow you to select two sounds, while register 3 provides access to three sounds. You may therefore have to press the register in question repeatedly.

NOTE

The dynamics of sounds marked with an asterisk (*) can only be controlled by bellows movements. Those sounds are not velocity sensitive. For the other sounds, see also Orchestra Bass/Chord Touch on p. 48.

NOTE

You can change the volume level of the orchestral bass or chord sound if it is too loud or too soft with respect to the other available sections. See Orchestra Bass Level, Orches- tra Chord Level, Orchestra Free Bass Level on p. 46.

Switching off the bass and/or chord section 1. To switch off a left-hand section you do not

want to hear, press and hold any of the three bass registers for a while. The section in question must be assigned to the asso- ciated registers. See the previous pages for how to decide which section can be muted.

NOTE

Even if you switch off the bass or chord section, it still transmits MIDI messages.

2. To switch a muted section back on, briefly press any of the associated registers.

Playing drum/percussion sounds The FR-1x allows you to play drum and percussion sounds with bass and chord buttons and to trigger the bass and chord sections simultaneously.

NOTE

This function is not available in Free Bass or Orchestra Free Bass mode.

1. To add drum/percussion sounds to the bass and chord section (or to remove them again), press the [DRUMS] button.

The display shows the number of the last Drum Set you selected (d-x, where x represents a number) or doF if you switched off the drum/percussion function.

2. Start playing in the left-hand section to hear the drum and percussion sounds. Those sounds are added to the accordion or orches- tral notes you play.

NOTE

See page 46 for how to select another Drum Set.

NOTE

The drum/percussion sounds also remain active while an orchestral sound is selected in Bass-to-Treble mode.

d-1

dof

0

Playing only bass notes with your left hand (Free Bass mode)

V-Accordion

FR-1x_1_GB.fm Page 31 Tuesday, November 8, 2011 2:56 PM

Playing only bass notes with your left hand (Free Bass mode) In Free Bass mode, all buttons of the left-hand key- boardincluding the chord buttonsplay bass notes.

1. To select (or leave) Free Bass mode, press the [FREE BASS] button.

The digit in the middle starts flashing to indicate that Free Bass mode has been activated:

If it does not flash, you are not/no longer in Free Bass mode.

NOTE

See page 52 for the assignment of the bass buttons to the available Free Bass notes.

2. Use the three bass registers to select another registration (if necessary).

Note that registers 1 and 2 allow you to select two sounds, while register 3 provides access to three sounds. You may therefore have to press the register in question repeatedly.

3. Press the [FREE BASS] button again to return to normal bass mode.

Selecting orchestral sounds in Free Bass mode 1. To select (or leave) Free Bass mode, press

the [FREE BASS] button.

2. Press the ORCHESTRAL [CHORD/FREE BASS] button.

The flashing digit in the middle now shows the num- ber of the last orchestral Free Bass sound you selected, along with a dot.

The dot means that you are in orchestral Free Bass mode. The number itself flashes to signal that the Free Bass section is active.

3. Press one of the three bass registers to select the desired sound. In this mode, the following sounds are available:

NOTE

The dynamics of sounds marked with an asterisk (*) can only be controlled by bellows movements. Those sounds are not velocity sensitive. For the other sounds, see also Orchestra Bass/Chord Touch on p. 48.

Note that registers 1 and 2 allow you to select two sounds, while register 3 provides access to three sounds. You may therefore have to press the register in question repeatedly.

4. To return to the accordion section, press the [CHORD/FREE BASS] button again.

NOTE

You can change the volume level of the orchestral Free Bass sound if it is too loud or too soft with respect to the other available sections. See Orchestra Bass Level, Orches- tra Chord Level, Orchestra Free Bass Level on p. 46.

Free Bass sounds

1 2 3

a Low Low + High High

b Low + High Low

Low Low + High

High Low + High

c Low High

662 Flashes

Orchestral Free Bass sounds [CHORD/FREE BASS]

1 2 3

a Strings* Jazz VTW* Ac Guitar

b Jazz Doos* Clarinet* Ac Piano

c Oboe*

662 Flashes and a dot appears

31

Using the FR-1xs audio player

3

FR-1x V-Accordion

FR-1x GB.book Page 32 Tuesday, November 8, 2011 11:44 AM

r 9. Using the FR-1xs audio player

The FR-1x can play back audio files in the mp3 and WAV formats directly from a USB memory you connect to its USB MEMORY port. See below for a description of the supported file types.

Copying audio files to a USB memory Before being able to play back audio (mp3 or WAV) on the FR-1x, you must first copy them from your com- puters hard disk to a USB memory that can be con- nected to the FR-1x.

Be aware that the FR-1x can only play back files located in the USB memorys root directory (i.e. on the same level as any folders the USB memory may contain). Never copy audio files to a folder if you wish to be able to play them back on the FR-1x.

About audio files Audio files in the following formats can be played back:

WAV format

16-bit linear

Sampling frequency: 44.1kHz

Stereo/mono

mp3 files:

MPEG-1 Audio Layer 3

Sampling frequency: 44.1kHz

Bit rate: 32/40/48/56/64/80/96/112/128/160/192/224/256/ 320kbps, VBR (variable bit rate)

Tip for naming audio files The FR-1x only displays the first three characters of the audio file names. If the USB memory contains several files whose first three characters are the same, we rec- ommend renaming those files on your computer by adding a number to their names. Here is an example: if the USB memory contains a file named Amazing Grace.wav and another one called Amazing.mp3, consider renaming them as follows to be able to distinguish between them: 1Amazing Grace.wav 2Amazing.mp3

Playing back audio files 1. Insert an optional USB memory into the

FR-1xs USB MEMORY port.

The USB memory can only be connected in one direc- tion. Insert the USB memory without applying exces- sive force.

NOTE

Carefully insert the USB memory all the way inuntil it is firmly in place.

NOTE

Use a USB memory sold by Roland (M-UF-series). We can- not guarantee operation if any other USB memory is used.

The FR-1x automatically loads the first audio file in alphabetical order that it detects in the USB mem- orys root folder.

2. Press the PLAYER [] button to start play- back.

X X

Copy your audio les to the root level.

2

Selecting audio les V-Accordion r

FR-1x GB.book Page 33 Tuesday, November 8, 2011 11:44 AM

Playback of the first audio file in alphabetical order in the root folder starts. The display briefly shows the first three characters of the audio files name as well as three dots that flash from left to right:

(In the example above, the display shows the first three characters of a file called Amazing Grace.wav.) The FR-1x only displays the first three characters of the audio file names. See Tip for naming audio files on p. 32 for how to ensure that you can tell the files apart. See page 71 for how the FR-1x displays the charac- ters of the selected file name.

3. If you are using the audio file as your accompaniment, start playing on the FR-1x as you normally would.

4. To pause playback of the audio file, press the [] button again. Playback of the selected audio file stops and the three dots flash simultaneously for a moment (after which the display returns to the main page):

5. To return to the beginning of the current song, press the PLAYER [] button.

NOTE

Press the PLAYER buttons [] and [] simultaneously to view the name of the currently selected audio file.

Selecting audio files As stated above, the FR-1x automatically selects the first audio file it detects on the USB memory you insert. To select a different file, proceed as follows:

1. Press and hold the [SET] register to enter PARAMETER mode. The display shows the name of the last parameter you selected.

2. If Parameter mode is not yet selected, press treble register [3] or [4] (PARAM LIST) until the display looks as follows:

NOTE

Instead of performing steps (1) and (2) above, you can also press and hold the [] button to jump to the first param- eter of Parameter mode (AUd).

ama

The scrolling dots (alternate ashing from left to right) mean that playback is running.

. . .

ama

If playback is stopped, the three dots ash simultaneously.

. . .

PIANO/GUITARWIND AUd

33

Using the FR-1xs audio player

3

FR-1x V-Accordion

FR-1x GB.book Page 34 Tuesday, November 8, 2011 11:44 AM

r 3. Use register [1] ( VALUE) or [2]

(VALUE ) to select the desired audio file.

(In the example above, the display shows the first three characters of a file called Scarborough.mp3.) The display shows the first three characters of the file name you selected. If you select another audio file while playback of the previously selected file is still running, the audio player stops. See page 71 for how the FR-1x displays the characters of the selected file name. To check whether you have selected the correct audio file, start playback ([]).

NOTE

The audio files are displayed based on the following sorting order: numbers, capital letters, small letters.

NOTE

You can only select audio files in the USB memorys root directory. Audio files inside folders are not detected.

4. Press the [SET] register to leave the FR-1xs PARAMETER mode.

Adjusting the playback level 1. Press and hold the [SET] register to enter

PARAMETER mode. The display shows the name of the last parameter you selected.

2. Use treble register [3] or [4] (PARAM LIST) to select the following parameter:

NOTE

Pressing registers [3] and [4] (PARAM LIST) simultaneously alternates between AUd (first parameter of the PARAME- TER group) and ESq (first parameter of the MIDI group). This may come in handy to close in on the parameter you need.

3. Use register [1] ( VALUE) or [2] (VALUE ) to set the playback level.

The setting range is: Off, 1~10. If you select Off, the audio file will be inaudible.

4. Press the [SET] register to leave the FR-1xs PARAMETER mode.

sCa

PIANO/GUITARWIND AUL

8

4

Highlighting some practical functions

V-Accordion

r

FR-1x_1_GB.fm Page 35 Tuesday, November 8, 2011 2:57 PM

10. Highlighting some practical functions

This chapter discusses functions like the metronome, the transposition function, Musette detuning and the speaker switch function.

Using the metronome Your FR-1x contains a metronome that may come in handy when you are practising new pieces, or during your accordion classes.

1. To start or stop the metronome, hold down the [SET] register and press register [3] (METRONOME). The display now briefly shows Str (start) or StP (stop) to indicate the status of the metronome.

NOTE

See Metronome Time Sign on p. 47 and Metronome Tempo on p. 47 as well as Metronome Level on p. 47 for how to set the metronomes time signature, tempo and level.

NOTE

If you hold down [SET] for more than 2 seconds without pressing another register, the FR-1x switches to PARAME- TER mode. In that case, press [SET] again to leave PARAME- TER mode, then continue with step 1.

NOTE

If the metronome does not start counting, check the Met- ronome Function setting on p. 47. It must be set to 1.

Changing the key of the keyboard (transpose) The Transpose function lets you play a song in a differ- ent key. If youre accompanying a singer, you can use the Transpose function to shift the pitch to a key thats comfortable for the singer while you continue playing in the same familiar key (fingering). The transposition interval can be set in semitones. See Transpose on p. 45 for how to set the transposition interval and page 44 for how to select the parameter.

Adjusting the balance The FR-1x provides a parameter that allows you to set the balance between the treble and bass & chord sec- tions. See Treble/Bass&Chord Balance on p. 45 for details and page 44 for how to select the parameter.

Musette Detune An accordions 8 treble register may consist of 2 or even 3 reeds that are usually tuned apart to provide a richer sound (accordionists call it the musette effect). One reed is tuned slightly above, the other slightly below the correct pitch (and the third, if available, is tuned properly). The FR-1x allows you to choose from among 15 differ- ent detune settings. These are called 1 (Dry), 2 (Classic), 3 (F-Folk), 4 (American L), 5 (American_H), 6 (North Eur), 7 (German L), 8 (D-Folk L), 9 (Italian L), 10 (German H), 11 (Alpine), 12 (Italian H), 13 (D-Folk H), 14 (French), 15 (Scottish). See Musette Detune on p. 45 for how to select the desired Musette detuning and page 44 for how to select the parameter.

NOTE

Musette Detune only affects registers that use the 8 reed.

PIANO/GUITAR

Str

35

Highlighting some practical functions

3

FR-1x V-Accordion

FR-1x_1_GB.fm Page 36 Tuesday, November 8, 2011 2:57 PM

r Switching off the internal speakers (Speaker Mode) When the FR-1x is connected to an external amplifica- tion system, it may be convenient to switch off its internal speakers. Doing so has the additional benefit that your batteries will last longer. See Speaker Mode on p. 55 for how to switch off the speakers and page 44 for how to select the parameter. The SPEAKER OFF indicator below the display lights when the speakers are off. It also lights when you con- nect headphones to the PHONES jack, because doing so switches off the speakers.

oFF

6

Saving your settings (User Program) V-Accordion

FR-1x GB.book Page 37 Tuesday, November 8, 2011 11:44 AM

11. Saving your settings (User Program)

Your FR-1x contains 8 User Program memories where you can store the settings listed below. Working with those mem- ories has the advantage that you can recall frequently used settings at the press of a button. The User Program settings also include the address of the last Set you selected.

The following settings are saved to the User Programs:

Saving the current settings Here is how to save the current settings.

1. Press and hold the [USER PROGRAM] button to select write mode.

The display now shows a flashing U message.

The USER PRG indicator below the display lights to indicate that the FR-1x is now in User Program mode.

NOTE

If you made a mistake and do not want to save your set- tings, press the [USER PROGRAM] button to leave this function.

Set Number of the current Set

Treble section

Register

Octave setting

Bass-to-Treble mode

Treble valve noise

Orchestra

Register

Octave setting

Level

Organ

Register

Octave setting

Level

Bass & Chord section

Register

Bass button noise

Bass reed growl

Orchestral Bass

On/Off

Register

Level

Orchestral Chord

On/Off

Register

Level

Orchestral Free Bass

On/Off

Register

Level

Drum mode

On/Off

Drum Set number

Level

Free Bass

On/Off

Register

Free Bass button noise

Free Bass reed growl

Other parameters

Reverb Type

Chorus Type

Reverb Level

Chorus Level

Balance

MIDI parameters

Treble Octave Tx

Bass/Free Bass Octave TX

Chord Octave TX

Orchestra/Organ Octave TX

Orchestra Bass Octave TX

Orchestra Chord Octave TX

Orchestra Free Bass Octave TX

U--

Lights

37

Saving your settings (User Program)

3

FR-1x V-Accordion

FR-1x GB.book Page 38 Tuesday, November 8, 2011 11:44 AM

r 2. Press the treble register ([1]~[4]) that is

assigned to the User Program memory where you want to save your settings.

Each treble register provides access to two User Pro- gram memories (for a total of eight). To select the A memory, press the register in question once. Press it twice to select the B memory. The to the right of U changes to the number of the selected User Program.

3. Press the [SET] register to save your settings in the User Program memory you selected in step 2 above.

4. Press the [USER PROGRAM] button again to leave this mode. The USER PRG indicator below the display goes dark to indicate that the FR-1x is no longer in User Pro- gram mode. At this point, the FR-1x returns to the settings you were using before selecting User Pro- gram mode, and the display once again shows the main page.

Recalling a User Program Proceed as follows to recall a User Program you saved earlier:

1. Press the [USER PROGRAM] button.

The display now shows a U message.

The USER PRG indicator below the display lights to indicate that the FR-1x is now in User Program mode.

2. Press the treble register ([1]~[4]) that is assigned to the User Program whose set- tings you want to use.

Each treble register provides access to two User Pro- gram memories (for a total of eight). To select the A memory, press the register in question once. Press it twice to select the B memory. The to the right of U changes to the number of the selected User Program.

3. Start playing with the new settings. If necessary, you can select a different User Program (see step 2 above).

4. Press the [USER PROGRAM] button again to leave this mode. The USER PRG indicator below the display goes dark to indicate that the FR-1x is no longer in User Pro- gram mode. At this point, the FR-1x returns to the settings you were using before selecting User Pro- gram mode, and the display once again shows the main page.

NOTE

While the USER PRG indicator below the display lights, it is impossible to select Sets. In order to select a Set, you will have to press the [USER PROGRAM] button to leave User Program mode.

Editing a User Program You can also edit existing User Programs.

1. Recall the User Program you want to edit. See Recalling a User Program.

2. Press and hold the [USER PROGRAM] button to select User Program Edit mode. The USER PRG indicator flashes. The display shows the main page where the numbers of the selected registers are displayed.

3. Change the settings you want to correct.

4. Press and hold the [USER PROGRAM] button to enter write mode.

U--

Lights

8

Saving your settings (User Program) V-Accordion

FR-1x GB.book Page 39 Tuesday, November 8, 2011 11:44 AM

The display now shows a flashing Uxx message (the xx refers to the User Program you have been editing thus far).

5. Do one of the following: To replace (overwrite) the settings of the User Pro-

gram you have been editing, press the [SET] register. To save the new version to a different User Program

memory, press the assigned treble register (once or twice), then press [SET].

Your settings are saved to the selected User Program memory.

6. Press the [USER PROGRAM] button again to leave this mode. The USER PRG indicator below the display goes dark to indicate that the FR-1x is no longer in User Pro- gram mode. At this point, the FR-1x returns to the settings you were using before selecting User Pro- gram mode, and the display once again shows the main page.

NOTE

While the USER PRG indicator below the display flashes, you can select another Set.

U1A

Flashes

39

Data management via the FR-1xs USB port

4

FR-1x V-Accordion

FR-1x GB.book Page 40 Tuesday, November 8, 2011 11:44 AM

r 12. Data management via the FR-1xs USB port

The FR-1x allows you to save and import User Program settings to/from an optional USB memory connected to its USB port. You can also import Sets and new sounds copied to your USB memory using your PC. The Sets and sounds are stored internally.

Saving User Program memories to USB memory (optional) Here is how to archive the contents of the FR-1xs 8 internal User Program memories (file extension .UP1) to an optional USB memory.

NOTE

Be sure to connect your USB memory before proceeding.

1. Insert an optional USB memory into the FR-1xs USB MEMORY port.

The USB memory can only be connected in one direc- tion. Insert the USB memory without applying exces- sive force.

NOTE

Use a USB memory sold by Roland (M-UF-series). We can- not guarantee operation if any other USB memory is used.

2. Press and hold down the [SET] register. The display shows the name of the last parameter you selected.

3. Use treble register [3] or [4] (PARAM LIST) to select SAv (Save).

4. Use treble register [1] or [2] (VALUE) to see the number of the file where the data will be saved. The display shows the name of the first empty file on the USB memory.

NOTE

If the USB memory doesnt yet contain any User Program files, the display shows 000, which represents the file name of the data you are about to save.

NOTE

The FR-1x uses numbers as file names to save your User Programs to USB memory. It cannot display the file num- bers that already are in the USB memory.

5. Press the [USER PROGRAM] (ENTER) button to save the data. The display shows Urt (Write), then don (Done), after which the FR-1x returns to the main page.

Loading User Program memories from USB memory (optional) The function discussed here allows you to load the set- tings of 8 User Programs from a USB memory to the FR-1xs internal memory.

1. Insert an optional USB memory into the FR-1xs USB MEMORY port.

2. Press and hold down the [SET] register. The display shows the name of the last parameter you selected.

3. Use treble register [3] or [4] (PARAM LIST) to select UPG (User Program).

PIANO/GUITARWIND SAv PIANO/GUITARWIND UPG

0

Loading User Set memories from USB memory (optional) V-Accordion

FR-1x GB.book Page 41 Tuesday, November 8, 2011 11:44 AM

4. Use treble registers [1] and [2] (VALUE) to select the file number of the User Programs you want to load. If the USB memory doesnt contain any User Program files, the display shows --- instead of a number.

5. Press the [USER PROGRAM] (ENTER) button to load the selected User Programs. The display shows Lod (Load), then don (Done), after which the FR-1x returns to the main page.

Loading User Set memories from USB memory (optional) The FR-1x allows you to copy individual Sets from a USB memory to the four internal USER Set locations. The Set files (with the extension .ST3) must first be copied to a USB memorys root directory before loading them into the FR-1xs USER area.

1. Insert an optional USB memory into the FR-1xs USB MEMORY port.

2. Press and hold down the [SET] register. The display shows the name of the last parameter you selected.

3. Use treble register [3] or [4] (PARAM LIST) to select USt (User Set).

4. Use treble registers [1] and [2] (VALUE) to select the file number of the Set you want to load. If the USB memory doesnt contain any Set files, the display will show --- instead of a number.

5. Press the [USER PROGRAM] (ENTER) button to confirm your selection. The FR-1x suggests USER memory 1 as target for the Set file.

6. Use treble registers [1] and [2] (VALUE) to select the desired target memory (1~4).

7. Press the [USER PROGRAM] (ENTER) button to load the selected Set.

The display shows Lod (Load), then don (Done) to indicate that the file was loaded successfully. Next, the FR-1x returns to the main page. See Selecting Sets on p. 24 for how to recall the settings of the desired User Set.

NOTE

See Restoring the User Sets to their factory defaults on p. 64 if you want to recover the FR-1xs original User Sets at a later stage.

PIANO/GUITARWIND Ust

41

Data management via the FR-1xs USB port

4

FR-1x V-Accordion

FR-1x GB.book Page 42 Tuesday, November 8, 2011 11:44 AM

r Loading new sounds from a USB memory (optional) The FR-1x allows you to add new sounds to the internal sounds. The new sounds (files with the .Bl3 extension) must be copied to a USB memorys root directory, after which you can load them with the FR-1x. Loading means that they will be copied to a permanent internal memory area. There are two such memory areas (1 and 2).

1. Insert an optional USB memory into the FR-1xs USB MEMORY port.

2. Press and hold down the [SET] register. The display shows the name of the last parameter you selected.

3. Use treble register [3] or [4] (PARAM LIST) to select Snd (Sound).

4. Use treble registers [1] and [2] (VALUE) to select the number of the sound file you want to load from the connected USB mem- ory. If the USB memory doesnt contain any sound files, the display will show --- instead of a number.

5. Press the [USER PROGRAM] (ENTER) button to confirm your selection. The FR-1x suggests memory area 1 as target for the selected file.

6. Use treble registers [1] and [2] (VALUE) to select the desired target memory area (1 or 2).

7. Press the [USER PROGRAM] (ENTER) button to load the selected sound set. The display shows Lod (Load) to indicate that the data are being loaded (this may take 1.5 minutes). Next, the don (Done) message appears to signal that the file was loaded successfully.

NOTE

The new sounds can only be used if you also load the asso- ciated User Sets and select one of those.

PIANO/GUITARWIND Snd

2

Other settings V-Accordion

FR-1x GB.book Page 43 Tuesday, November 8, 2011 11:44 AM

13. Other settings

The FR-1x has a mode that allows you to make various settings and perform certain operations. Below please find a list of the parameters you can set in this mode.

Display indication Full name Setting range Default See page

AUd Audio file name (file name, 3 characters) p. 33 *3

AUL Audio Level Off, 1~10 8 p. 34

bal Treble/Bass&Chord Balance b64~b1,Cen, t1~t63 t15 p. 45

dEt Musette Detune Off, 0~15 (variable) p. 45

tUn Master Tune 15.7~40.0~64.3 40.0 p. 45 *1

trp Transpose 6~0~5 0 p. 45 *1

drs Drum Set 1~8 1 p. 46

drl Drum Level Low, Med, Hi, 40~Std~+40 Std p. 46

o l Orchestra Level 40~Std~+40 Std p. 46

ogl Organ Level 40~Std~+40 Std p. 46

obl Orchestra Bass Level 40~Std~+40 Std p. 46

oCL Orchestra Chord Level 40~Std~+40 Std p. 46

ofL Orchestra Free Bass Level 40~Std~+40 Std p. 46

trn Treble Valve Noise Off, 40~Std~+40 Std p. 46

bbn Bass Button Noise Off, 40~Std~+40 Std p. 46

brg Bass Reed Growl Off, 40~Std~+40 Std p. 46

fbn Free Bass Button Noise Off, 40~Std~+40 Std p. 47

Frg Free Bass Reed Growl Off, 40~Std~+40 Std p. 47

MtP Metronome Tempo 20~250 120 p. 47

mts Metronome Time Sign 1~8 1 p. 47

m l Metronome Level OFF, 1~127 100 p. 47

mfn Metronome Function 1, 2 1 p. 47

rEv Reverb Type 1~8 2 p. 47

r l Reverb Level 0~127 64 p. 48

Chr Chorus Type 1~8 2 p. 48

C l Chorus Level 0~127 64 p. 48

o t Orchestra Touch 1~10 6 p. 48

obt Orchestra Bass/Chord Touch 1~10 8 p. 48

blC Bellows Curve 1~8 6 p. 49

StE Stereo Width -63~1, Nat, Ful Nat p. 49

trm Treble Mode 1~6 1 p. 49 *2, *4

fbm Free Bass Mode 1~5 1 p. 51 *4

bCm Bass & Chord Mode 1~7 1 p. 53 *4

btt Bass to Treble Off, On Off p. 53

fns Function Switch Off, On Off p. 53

Aof Auto Off Off, 1~3 1 p. 55

sp Speaker Mode Off, On On p. 55 *1

oLA Output Level Attenuation 12, 6, Off Off p. 55

USt User Set load 000~999 p. 41 *3

UrC User Set recover 1~4 1 p. 64 *3

43

Other settings

4

FR-1x V-Accordion

FR-1x GB.book Page 44 Tuesday, November 8, 2011 11:44 AM

r

NOTE

The FR-1xs PARAMETERS environment also contains MIDI parameters. For the sake of clarity, the following sec- tion only discusses parameters that are not related to MIDI. See MIDI parameters on p. 59 for the available MIDI parameters.

Important remark about saving your settings The FR-1xs internal memory remembers your settings while the FR-1x is switched on. While editing, there is no absolute need to save your settings. Be aware, however, that all changes are lost when the FR-1x is switched off. This includes situations where the FR-1x is switched off by the Auto Off function. Remember to save all settings as soon as you are sure that you want to keep them.

Selecting the desired parameter 1. Press and hold the [SET] register to enter

PARAMETER mode. The display shows the name of the last parameter you selected (AUd in our example).

2. Use treble register [3] or [4] (PARAM LIST) to select the desired parameter.

(Here, we selected the Orchestra Chord Level parameter.)

NOTE

Pressing registers [3] and [4] (PARAM LIST) simultaneously alternates between AUd (first parameter of the PARAME- TER group) and ESq (first parameter of the MIDI group). This may come in handy to close in on the parameter you need.

3. Use treble register [1] ( VALUE) or [2] (VALUE ) to set the desired value.

To return to the last setting you saved for this parameter, press registers [1] and [2] simultaneously.

4. If you want to use this change only tempo- rarily, press the [SET] register to leave this mode. Otherwise, proceed to save your changes:

UPG User Program load 000~999 p. 40 *3

Snd Sound Set load 000~999 p. 42 *3

SAv User Program save 000~999 p. 41 *3

The trn, fbn and bCm parameters are not reset when you load the factory defaults.

*1 Reset when you switch off the FR-1x *2 Only on the FR-1x button type *3 These are functions. *4 This parameter is not reset when you load the factory defaults.

Display indication Full name Setting range Default See page

AUd

PIANO/GUITARWIND oCL

40

4

Saving your changes V-Accordion

FR-1x GB.book Page 45 Tuesday, November 8, 2011 11:44 AM

Saving your changes 1. Press and hold the [SET] register until the

display looks as follows:

2. Press register [2] (VALUE ) to save your settings. The display now looks as follows:

If you dont want to save your changes, press [1] ( VALUE). The display briefly shows the no mes- sage.

3. Press the [USER PROGRAM] (ENTER) button to confirm your intention. The settings are stored internally and the display briefly shows the y.E.S. message (the three dots flash), then don when the settings are stored. Next, the display returns to the master page.

PARAM LIST parameters Audio file name This parameter allows you to select the audio file you want to play back. See Selecting audio files on p. 33.

NOTE

You can only select audio files in the USB memorys root directory. Audio files inside folders are not detected.

Audio Level This parameter allows you to set the vol- ume level of the selected audio file. See Adjusting the playback level on p. 34.

Treble/Bass&Chord Balance This parameter allows you to adjust the volume balance between the bass/chord and treble sections. Any setting with a b means that the bass & chord section is louder than the treble section (t).

Musette Detune This parameter allows you to choose the detuning preset. See Musette Detune on p. 35 for details. You can select one of the following detuning presets:

The deafult setting is 2. If the oFF message is dis- played, the selected register cannot be detuned.

NOTE

Musette Detune only affects registers that use more than one 8 reed.

Master Tune This parameter allows you to change the FR-1xs overall tuning, which may be necessary when you play with acoustic instruments that cannot be tuned easily. The factory default is 440.0Hz.

NOTE

The display only shows the last three digits. The setting 464.3 is therefore displayed as 64.3.

Transpose This parameter allows you to transpose all sections of the FR-1x. See Changing the key of the keyboard (transpose) on p. 35.

Value (file name, 3 characters)

Default setting:

Value Off, 1~10

Default setting: 8

Urt

YES

AUd

AUl

Value b64~b1,Cen, t1~t63

Default setting: t15

Value Setting Value Setting

0 No detune 8 D-Folk L

1 Dry 9 Italian L

2 Classic 10 German H

3 F-Folk 11 Alpine

4 American L 12 Italian H

5 American_H 13 D-Folk H

6 North Eur 14 French

7 German L 15 Scottish

Value 15.7~64.3 (415.7~464.3Hz)

Default setting: 40.0 (440.0Hz)

Value 6~0~+5

Default setting: 0

bal

det

tUn

trP

45

Other settings

4

FR-1x V-Accordion

FR-1x GB.book Page 46 Tuesday, November 8, 2011 11:44 AM

r Drum Set This parameter allows you to select the type of drum/percussion instruments you wish to play simultaneously with the bass and chord section. See also Playing drum/per- cussion sounds on p. 30.

Drum Level This parameter allows you to set the audio level of the drum sounds.

Select Lo (low), Med (medium) or Hi (high) to use a preset level value. If you select a value, it is added to, or subtracted from, the standard value (Std).

Orchestra Level This parameter allows you to set the level of the orchestral sounds. It can be useful to create the desired mix (vol- ume balance) with the treble accordion sounds.

This is a relative parameter, which means that its value is added to, or subtracted from, the standard value (Std).

Organ Level This parameter allows you to set the level of the organ sounds. It can be use- ful to create the desired mix (volume balance) with the treble accordion sounds.

This is a relative parameter, which means that its value is added to, or subtracted from, the standard value (Std).

Orchestra Bass Level, Orchestra Chord Level, Orchestra Free Bass Level These parameters allow you to set the audio level of the Orchestra Bass, Orchestra Chord and Orchestra Free Bass sections.

Treble Valve Noise You will probably agree that electronic sounds must not only reproduce the basic timbre of an existing sound, but also the original instruments behavior and typical noises in order to be perceived as authentic. In the case of a guitar that would be the sliding noise of the fingers. An accordion, on the other hand, produces mechanical valve noises that cannot be suppressed on an acoustic instrument. Use this parameter to specify how prominent the noise produced by the simulated treble valves should be.

Bass Button Noise The bass section of almost all accordion instruments can be played via buttons. Such buttons produce a typical noise when pressed. Use this parameter to specify how prominent that but- ton noise should be.

Bass Reed Growl This parameter allows you to simulate the typical noise a bass reed makes just before it stops vibrating altogether (a kind of musical flatulence if you will). Each instru- ment of the accordion family produces its own typical growl. Use this parameter to specify how prominent that growl should be.

Value 1~8

Default setting: 1

Set Type Set Type

1 Folk1 5 Latin1

2 Folk2 6 Latin2

3 Jazz 7 V-Dance

4 March Band 8 Ethnic

Value Lo, Med, Hi, 40~Std~+40

Default setting: Std

Value 40~Std~+40

Default setting: Std

Value 40~Std~+40

Default setting: Std

drs

drl

o L

oGL

Value 40~Std~+40

Default setting: Std

Value Off, 40~Std~+40

Default setting: Std

Value Off, 40~Std~+40

Default setting: Std

Value Off, 40~Std~+40

Default setting: Std

obL

oCL

oFL

trn

bbn

brg

6

Orchestra Level V-Accordion

FR-1x GB.book Page 47 Tuesday, November 8, 2011 11:44 AM

Free Bass Button Noise The bass section of almost all accordion instruments can be played via buttons. Such buttons produce a typical noise when pressed. Use this parameter to specify how prominent that but- ton noise should be in Free Bass mode.

Free Bass Reed Growl This parameter allows you to simulate the typical noise a bass reed makes just before it stops vibrating altogether (a kind of musical flatulence if you will). Each instru- ment of the accordion family produces its own typical growl. Use this parameter to specify how prominent that growl should be in Free Bass mode.

Metronome Tempo This parameter allows you to set the metronome tempo. See page 35 for how to activate the metronome.

Metronome Time Sign This parameter allows you to set the metronomes time signature. See page 35 for how to activate the metro- nome.

Here is what the displayed values correspond to:

Metronome Level This parameter allows you to change the metronomes level when it is too loud or too soft. See page 35 for how to activate the metronome.

Metronome Function This parameter allows you to choose the function to combine when you hold down the [SET] register and press treble register [3] (METRONOME). See Using the metronome on p. 35.

The available options are:

Metronome Select this setting to take advantage of the internal metronome.

MIDI Start/Stop This option means that the register combination acts as a MIDI remote control that starts and stops play- back of an external sequencer or arranger module.

Reverb Type This effect creates the impression that you are playing in a concert hall, a church or a room. It adds depth to the sound. This is where you can specify what kind of effect the Reverb processor should generate.

This parameter is a Macro function that recalls suit- able preset values for all reverb parameters (which have been preset at the factory). The available options are:

Value Off, 40~Std~+40

Default setting: Std

Value Off, 40~Std~+40

Default setting: Std

Value 20~250

Default setting: 120

Value 1~8

Default setting: 1

Value Time signature Value Time signature

1 1/4 5 5/4

2 2/4 6 6/4

3 3/4 7 6/8

4 4/4 8 9/8

Value Off, 1~127

Default setting: 100

Fbn

Frg

mtp

mts

m l

Value 1, 2

Default setting: 1

Value Setting

1 Metronome

2 MIDI Start/Stop

Value 1~8

Default setting: 2

Value Type Meaning

1 2 3

Room1 Room2 Room3

These reverbs simulate the rever- beration of a room. They provide a well-defined spacious reverbera- tion.

4 5

Hall1 Hall2

These reverbs simulate the rever- beration of a concert hall with a deeper reverberation than the Room Reverbs.

6 Plate This effect type simulates a plate reverb (a studio device using a metal plate to simulate natural Reverb).

7 Delay This is a conventional delay that produces echo effects.

8 PanningDly This is a special delay in which the delayed sounds move left and right. It is effective when you are listen- ing in stereo.

mfn

rEv

47

Other settings

4

FR-1x V-Accordion

FR-1x GB.book Page 48 Tuesday, November 8, 2011 11:44 AM

r Reverb Level This parameter allows you to set the level of the reverb effect with respect to the unprocessed signal. Set it to 0 if you dont want to use the reverb effect.

Chorus Type Chorus broadens the spatial image of the sound, adding richness. You can choose from 8 types of chorus. This parameter is a Macro function that recalls suitable preset values for all Chorus parameters (which have been preset at the factory).

The available options are:

Chorus Level This parameter allows you to set the level of the chorus effect with respect to the unprocessed signal. Set it to 0 if you dont want to use the chorus effect.

Orchestra Touch This parameter allows you to specify the velocity sensitivity of the treble keys/ buttons when they are used to play orchestral percussive sounds.

The available options are:

Fixed Low, Fixed Medium, Fixed High These three fixed curves use the same velocity value, no matter how hard or lightly you press the keys. Low means that a low value is used, Med repre- sents a medium value and High a high value.

Low, Medium, High The Low curve means that even relatively light presses already allow you to play loud notes. The High curve represents the most responsive velocity curve. It requires a considerable amount of strength for fortissimo notes, but it also provides more expres- sive options. The Med curve is in the middle.

Fixed L+Bellows, Fixed M+Bellows Fixed H+Bellows These curves mean that the orchestral sound uses fixed velocity values but can also be controlled by bellows movements.

Bellows Bellows means that the Orchestra sections expres- sion is controlled by the bellows movements not the velocity values generated by the keys.

NOTE

By selecting a Fixed option for Bellows Curve on p. 49, you effectively switch off the bellows sensor. This also means that any setting that includes Bellows no longer works, because the FR-1x no longer listens to the bellows movements.

Orchestra Bass/Chord Touch This parameter allows you to specify the velocity sensitivity (curve) of the bass and chord buttons, which are used to play orchestral percussive sounds.

The available options are: Fixed Low, Fixed Medium, Fixed High, Low, Medium, High, Fixed L + Bellows, Fixed M + Bellows, Fixed H+ Bellows, Bellows. See Orchestra Touch on p. 48 for details about these set- tings.

NOTE

By selecting a Fixed option for Bellows Curve on p. 49, you effectively switch off the bellows sensor. This also means that any setting that includes Bellows no longer works, because the FR-1x no longer listens to the bellows movements.

Value 0~127

Default setting: 64

Value 1~8

Default setting: 7

Value Type Meaning

1 2 3 4

Chorus 1 Chorus 2 Chorus 3 Chorus 4

These are conventional Chorus effects that add spaciousness and depth to the sound.

5 FBack Chr This is a Chorus with a Flanger-like effect and a soft sound.

6 Flanger This is an effect that sounds some- what like a jet airplane taking off or landing.

7 Short Delay This is a delay with a short Delay time.

8 ShortDly FB This is a short delay with many repeats.

Value 0~127

Default setting: 64

Value 1~10

Default setting: 6

r L

Chr

C L

o t

Value Setting Value Setting

1 Fixed Low 6 High

2 Fixed Medium 7 Fixed L + Bellows

3 Fixed High 8 Fixed M + Bellows

4 Low 9 Fixed H + Bellows

5 Medium 10 Bellows

Value 1~10

Default setting: 8

obt

8

Orchestra Level V-Accordion

FR-1x GB.book Page 49 Tuesday, November 8, 2011 11:44 AM

Bellows Curve This parameter allows you to specify how the FR-1x should respond to the bellows movements. Use it to adapt the FR-1xs expressive potential to your playing style.

The available options are:

Fixed Low, Fixed Medium, Fixed High These three fixed curves always use the same expres- sion value, no matter how hard or lightly you push/ pull the bellows (no dynamic control). Low means that a low value is used, Med represents a medium value and High a high value.

X Light, Light Light means that you do not need to push/pull hard to achieve a meaningful effect. The X-Light requires even less strength (the X stands for extra).

Standard The Standard curve refers to a normal response.

Heavy and X Heavy Heavy provides a greater variety of nuances. X-Heavy is even more detailed.

Stereo Width Much care has been taken to provide a natural stereo image for the accordion sounds. If you think the stereo image is too wide for comfort (or if you prefer to set the Pan controls on your mixing console differently), you can use this parameter to reduce the stereo image.

Ful (full) represents the widest stereo image. Nat (natural) means that the original stereo image is used. 63 corresponds to an extremely narrow stereo image. All other values represent slight (or increasingly drastic) reductions of the stereo width.

Treble Mode (only on the button type) Like for the accordion instrument itself, there are different varieties of chromatic instruments, with different treble button layouts.

The available options are:

Since your FR-1x is an electronic musical instrument, changing the note assignments to the buttons is a mat- ter of selecting the preset that best suits your playing style. Youll probably only change this setting once. But its nice to know that it exists in case you let a fellow accordion player from another country play your FR-1x. Please look at the illustrations on pages 50 and 51 to identify the setting you need. Pay attention to the note names (all Cs appear on a grey background) and look at how they are arranged, then make your selection. The numbers next to the letters refer to the octave. The numbers below the note names represent the corre- sponding MIDI note numbers. You may have noticed that the treble buttons are col- ored white (for notes without alteration) and black (notes with alteration, i.e. #/b). This coloring doesnt change when you select another system. The FR-1x is supplied with additional white and black buttons. You can use these additional buttons to adapt the black and white treble buttons to reflect the selected treble mode. To do this, first remove the button you wish to replace by turning it counterclockwise, then install the new button and screw it clockwise.

NOTE

This parameter is not reset when you load the factory defaults (page 64).

Value 1~8

Default setting: 6

Value Setting Value Setting

1 Fixed Low 5 Light

2 Fixed Medium 6 Standard

3 Fixed High 7 Heavy

4 X Light 8 X Heavy

Value 63~1, Nat, Ful

Default setting: Nat

blC

StE

Value 1~6

Default setting: 1

Value Setting Value Setting

1 C-Griff Europe 4 B-Griff Fin

2 C-Griff 2 5 D-Griff 1

3 B-Griff Bajan 6 D-Griff 2

trM

49

Other settings

5

FR-1x V-Accordion

FR-1x GB.book Page 50 Tuesday, November 8, 2011 11:44 AM

r

C-Griff Europe C-Griff 2 B-Griff Bajan

F#5

Eb6

G#5

Bb5

C#6

F#6

G5 A5

A5 B5

B5 D6

E6 F6 F6

Eb6D6

C6 C6

G#5

F#6 G#6

G6 A6

G#6

C#4 D4

Eb4 E4D4

Bb3 B3

C4 C#4B3

G3 G#3

A3 Bb3G#3

E4 F4

F#4 G4F4

C#5 D5

Eb5 E5D5

Bb4 B4

C5 C#5B4

G4 G#4

A4 Bb4G#4

E5 F5

F#5 G5F5

C#6 D6

Eb6 E6D6

Bb5 B5

C6 C#6B5

G5 G#5

A5 Bb5G#5

E6 F6

F#6 G6F6 G6 G#6

A3

G3 F#3

G#3 G3 Bb3 A3

C4 B3 Bb3 C#4 C4

Eb4 D4 C#4

E4 Eb4

F#4 F4 E4 G4 F#4

A4 G#4 G4

Bb4 A4

C5 B4 Bb4

C5 Eb5 D5 C#5

E5 Eb5

F#5 F5 E5

A5 G5

Bb5 A5

C#5

G5 F#5

G#5

C6 B5 Bb5 C6

Eb6 D6 C#6 E6 Eb6

F#6 F6 E6

C#6

G6 F#6

Eb4

G#3

Bb3

C#4

F#4

A3 A3 B3

B3 D4

E4 F4 F4

Eb4D4

C4 C4

F#4

Eb5

G#4

Bb4

C#5

F#5

G4 A4

A4 B4

B4 D5

E5 F5 F5

Eb5D5

C5 C5

G#4

Treble Mode (1/2)

0

Orchestra Level V-Accordion

FR-1x GB.book Page 51 Tuesday, November 8, 2011 11:44 AM

Free Bass Mode This parameter allows you to choose the note system used in Free Bass mode. We already mentioned that there are a vast number of accordion varieties. The same is true of Free Bass systems.

The available options are:

Your FR-1x contains the 5 most popular modes (see the illustration on page 52). Be aware that the system you select here is only used when you activate the FR-1xs Free Bass mode. It is of no consequence for regular Bass mode.

NOTE

The FR-1x is supplied with several reference caps designed to help you locate the bass buttons without looking at them. See also page 28.

NOTE

This parameter is not reset when you load the factory defaults (page 64).

Treble Mode (2/2)

B-Griff Fin D-Griff 1 D-Griff 2

D4 C#4

Eb4 D4E4

B3 Bb3

C4 B3C#4

G#3 G3

A3 G#3Bb3

C4 B3

C#4 C4D4 Eb4 D4

A3 G#3 A3 Bb3

Bb3 A3B3

F#3 F3

G3 F#3G#3

F#3

G#3 A3G3

G3

Eb5 D5

E5 Eb5F5

C6 B5

C#6 C6D6

A5 G#5

Bb5 A5B5

F#5 F5

G5 F#5G#5

Eb6 D6

E6 Eb6F6 F#6 F6

E4 Eb4F4

C5 B4

C#5 C5D5

A4 G#4

C4 C#4

Bb4 A4B4

F#4 F4

G4 F#4G#4

D4 Eb4C#4

B3 C4Bb3

Eb4 E4

F4 F#4E4

A4 Bb4

F#4 G4

G#4 A4G4

C5 C#5 D5 Eb5C#5

B4 C5Bb4

Eb5 E5

F5 F#5E5

A5 Bb5

F#5 G5

G#5 A5G5

C6 C#6 D6 Eb6C#6

B5 C6Bb5

Eb6 E6

F6 F#6E6 F#6 G6

F4 E4

F#4 F4G4

D5 C#5

Eb5 D5E5

B4 Bb4

C5 B4C#5

G#4 G4

A4 G#4Bb4

F5 E5

F#5 F5G5

D6 C#6

Eb6 D6E6

B5 Bb5

C6 B5C#6

G#5 G5

A5 G#5Bb5

F6 E6

F#6 F6G6 G#6 G6

Value 1~5

Default setting: 1

Value Setting Value Setting

1 Minor 3rd 4 N. Europe

2 Bajan 5 Finnish

3 Fifth

fbm

51

Other settings

5

FR-1x V-Accordion

FR-1x GB.book Page 52 Tuesday, November 8, 2011 11:44 AM

r

N. Europe

Finnish

F2 C3 G2 D3 A2 E2 B2 F#2 C#3 Ab2 Eb2 Bb2

C#3 Ab2 Eb2 Bb2 F2 C3 G2 D3 A2 E2 B2 F#2

F2 C3 G2 D3 A2 E2 B2 F#2 C#3 Ab2 Eb2 Bb2

C#3 Ab2 Eb2 Bb2 F2 C3 G2 D3 A2 E2 B2 F#2

F2 C3 G2 D3 A2 E2 B2 F#2 C#3 Ab2 Eb2 Bb2

C#3 Ab2 Eb2 Bb2 F2 C3 G2 D3 A2 E2 B2 F#2

F6 D6 B5 Ab5 F5 D5 B4 Ab4 F4 D4 B3 Ab3

E6 C#6 Bb5 G5 E5 C#5 Bb4 G4 E4 C#4 Bb3 G3

Eb6 C6 A5 F#5 Eb5 C5 A4 F#4 Eb4 C4 A3 F#3

D6 B5 Ab5 F5 D5 B4 Ab4 F4 D4 B3 Ab3 F3

F2

B4

C3 G2 D3 A2 E2 B2 F#2 C#3 Ab2 Eb2 Bb2

C#3 Ab2 Eb2 Bb2 F2 C3 G2 D3 A2 E2 B2 F#2

Free Bass Mode

(C3= note number 48)

NOTE

The note names on the bass buttons correspond to the MIDI note numbers. The note range of the Bass part is 1 octave.

NOTE

The actual sound range depends on the type of reed and footage.

2

Orchestra Level V-Accordion

FR-1x GB.book Page 53 Tuesday, November 8, 2011 11:44 AM

Bass & Chord Mode This parameter allows you to specify the number of button rows available for playing bass notes. The default is 2 bass rows and 4 chord rows.

The available options are:

2 Bass Rows Using this selection, you have 2 bass rows and 4 chord rows available (default).

3 Bass Rows A-7th, 3 Bass Rows A-5dim 3 Bass Rows B-7th, 3 Bass Rows B-5dim With this selection you gain 12 bass buttons (an entire row), but you lose the dim chords. The A-7th and B-7th options mean that the 6th chord row plays seventh chords (7) that dont con- tain the fifth. In the case of a C7 chord, you therefore hear C-E-Bb (but not the G). A-7th and B-7th differ in the arrangement of the bass notes (see the illustration on page 54). The A-5dim and B-5dim options mean that sev- enth chords dont contain the root note. A C7 chord is therefore sounded with the notes E-G-Bb (but not the C). A-5dim and B-5dim differ in the arrange- ment of the bass notes (see the illustration on page 54).

3 Bass Rows Bx-7th This option reverses the B-7th settings (from right to left), so that the C3 note shifts from 6th to 9th position.

3 Bass Rows Belgium This option simulates a straight Belgian bass & chord keyboard. See the illustration on p. 54 for the note assignments.

NOTE

The FR-1x is supplied with several reference caps designed to help you locate the bass and chord buttons without looking at them. See also page 28.

NOTE

This parameter is not reset when you load the factory defaults (page 64).

Bass to Treble When this function is switched on, the FR-1x can be used like a bassoon accor- dion. In this mode, the bass part is played with the right hand. The bass and chord buttons are inactive (a real bassoon accordion doesnt have bass/chord buttons and can only be played with one hand).

Function Switch This parameter allows you to use the bass buttons closest to the FR-1x logo to select or control the desired functions. When this parameter is set to On, the buttons in question can no longer be used to play notes or chords.

The buttons have the following factory default settings.

Value 1~7

Default setting: 1

Value Setting Value Setting

1 2 Bass Rows 5 3 Bass Rows B-5dim

2 3 Bass Row A-7th 6 3 Bass Rows Bx-7th

3 3 Bass Rows A-5dim 7 3 Bass Rows Belgium

4 3 Bass Rows B-7th

bCM

Value Off, On

Default setting: Off

Value Off, On

Default setting: Off

Bass button Function Bass button Function

1 Pitch Down 4 Brake Off

2 Pitch Up 5 Brake On

3 Modulation 6 Rotary Slow/ Fast

btt

fns

[1] [6]

53

Other settings

5

FR-1x V-Accordion

FR-1x GB.book Page 54 Tuesday, November 8, 2011 11:44 AM

r

A3D3G3

D3G3

[1] 2 Bass Rows

[2] & [3] 3 Bass Rows A

[4] & [5] 3 Bass Rows B

[6] 3 Bass Rows Bx 7th

[7] 3 Bass Rows Belgium

B3 E3 A3 D3 G3 C3 F3 Bb3 Eb3 Ab3 C#3 F#3

C3 F3 Bb3 Eb3 Ab3 C#3 F#3 B3 E3 A3 D3 G3

Ab3 C#3 F#3 B3 E3 A3 D3 G3 C3 F3 Bb3 Eb3

AbM C#M F#M BM EM AM DM GM CM FM BbM EbM

Abm C#m F#m Bm Em Am Dm Gm Cm Fm Bbm Ebm

Ab7 C#7 F#7 B7 E7 A7 D7 G7 C7 F7 Bb7 Eb7

E3 A3 D3 G3 C3 F3 Bb3 Eb3 Ab3 C#3 F#3 B3

F3Bb3 Eb3 Ab3 C#3 F#3 B3 E3 A3 D3 G3 C3

C#3F#3 B3 E3 A3 D3 G3 C3 F3 Bb3 Eb3 Ab3

C#MF#M BM EM AM DM GM CM FM BbM EbM AbM

C#mF#m Bm Em Am Dm Gm Cm Fm Bbm Ebm Abm

C#7B7 E7 A7 D7 G7 C7 F7 Bb7 Eb7 Ab7 F#7

Bass & Chord Mode

7th= 1-3-7; 5dim= 3-5-7

7th= 1-3-7; 5dim= 3-5-7

7th= 1-3-7

7th= 1-3-7

4

Orchestra Level V-Accordion

FR-1x GB.book Page 55 Tuesday, November 8, 2011 11:44 AM

Auto Off This parameter allows you to specify how long the FR-1x should wait before switching itself off while you are not using it.

The available options are:

WARNING: Be aware that any unsaved changes are lost when the FR-1x is switched off by this function. Be sure to save all important settings as soon as you can (page 45).

Speaker Mode When you use the FR-1x for live perfor- mances and therefore connect it to an external amplification system, it may be convenient to switch off the FR-1xs internal speakers, because doing so preserves battery power. See also Switching off the internal speakers (Speaker Mode) on p. 36.

The Off setting means that the internal speakers are off. The On setting means that the internal speakers are active.

Output Level Attenuation The FR-1x has a level attenuation func- tion that allows you to adapt its output level to the audio device you wish to connect it to. The attenuation value is expressed in dB.

NOTE

This parameter has no effect on the FR-1xs internal speakers.

Other functions The following functions are covered in the chapter Data management via the FR-1xs USB port on p. 40.

User Set load This function allows you to load Sets from a USB memory to one of the four internal User memories. See Loading User Set memories from USB memory (optional) on p. 41.

User Set recover This function allows you to recover the factory settings of the desired User Set memory. This function only loads one set at a time. See also page 64.

User Program load This function allows you to load 10 User Program settings from a USB memory (provided you have already saved User Programs to that USB memory). See also Loading User Program memories from USB memory (optional) on p. 40.

Sound Set load This function allows you to add new sounds to the FR-1x original sounds. See Loading new sounds from a USB memory (optional) on p. 42 for details.

User Program save This function allows you to save the contents of the User Program memo- ries to a USB memory (optional) con- nected to the USB port. See Saving User Program memories to USB memory (optional) on p. 40.

Value Off, 1~3

Default setting: 1

Setting Meaning Setting Meaning

Off Disabled 2 15 minutes

1 10 minutes 3 20 minutes

Value Off, On

Default setting: On

Value 12, 6, Off

Default setting: Off

AoF

SP

oLA

Ust

UrC

Upg

Snd

SAv

55

Connecting to MIDI devices

5

FR-1x V-Accordion

FR-1x GB.book Page 56 Tuesday, November 8, 2011 11:44 AM

r 14. Connecting to MIDI devices

By connecting an external MIDI device and exchanging performance data, you can control one device from another. For instance, you can output sound from other instruments, switch sounds or transmit MIDI data from the FR-1x that cause an external sound module to play.

Whats MIDI? MIDI, short for Musical Instrument Digital Interface, was developed as a universal standard for exchange of performance data with external devices. This con- nector can be used to connect the FR-1x to an exter- nal device for even greater versatility.

Connecting an external MIDI device to the FR-1x The FR-1x has one MIDI socket that can be used to transmit MIDI data.

1. Turn the volume all the way down on the FR-1x and the MIDI device you are about to connect.

2. Use a MIDI cable (commercially available) to connect the FR-1xs MIDI OUT socket to the MIDI IN socket of an external device. Connection to transmit MIDI data to an external device:

NOTE

MIDI reception is only possible via the USB COMPUTER port.

3. Adjust the volume level on the FR-1x and the connected device.

4. Set the MIDI channel on the FR-1x and the external device if necessary. The FR-1xs sections transmit on the following MIDI channels (default):

NOTE

See the external devices owners manual for how to set its MIDI channel.

External MIDI device: MIDI IN

Part TX/RX Channel

Treble 1

Bass/Free Bass 2

Chord 3

Orchestra/Organ (Treble) 4

Orchestra Bass 5

Orchestra Chord 6

Orchestra Free Bass 7

Drum Set (note messages) 10*

[*] This channel number cannot be changed.

Basic channel (for selecting Sets) 13

6

Communication via the USB COMPUTER port V-Accordion r

FR-1x GB.book Page 57 Tuesday, November 8, 2011 11:44 AM

Communication via the USB COMPUTER port If you use a USB cable (commercially available) to con- nect the FR-1xs USB COMPUTER port to a USB port of your computer, youll be able to do the following. By transferring MIDI data between the FR-1x and your sequencer software, youll be able to enjoy a wide range of possibilities for music production and editing.

1. Use a standard USB cable (AB-type con- nectors, commercially available) to connect the FR-1x to your computer as shown below.

2. Select the USB driver you want to use (see p. 63).

3. Refer to the Roland website for system requirements. Roland website: http://www.roland.com/

If the computer doesnt see the FR-1x Normally, you dont need to install a driver in order to connect the FR-1x to your computer. However, if some problem occurs, or if the performance is poor, using the Roland original driver may solve the prob- lem. For details on downloading and installing the Roland original driver, refer to the Roland website: http://www.roland.com/ Specify the USB driver you want to use, and then install the driver. For details, refer to page 63.

Caution To avoid the risk of malfunction and/or damage to

external speakers, always turn the volume all the way down and switch off the power on all devices before you make any connections.

Only MIDI data can be transmitted and received via USB. Audio data cannot be transmitted or received.

Switch on the power to the FR-1x before you start up the MIDI application on your computer. Never turn the FR-1xs power on/off while your MIDI application is running.

USB cable

USB connector

Computer

USB COMPUTER port

57

Connecting to MIDI devices

5

FR-1x V-Accordion

FR-1x GB.book Page 58 Tuesday, November 8, 2011 11:44 AM

r MIDI parameter list The parameters shown below are in fact the continuation of the parameters listed on page 45

Display indication Full name Setting range Default See page

ESq External Sequencer No, Yes No p. 59*

trb Treble TX/RX channel 1~16, Off 1 p. 60

tro Treble Octave Tx 3~0~3 0 p. 60

bfr Bass/Free Bass TX/RX Channel 1~16, Off 2 p. 60

bfo Bass/Free Bass Octave TX 3~0~3 0 p. 60

Chd Chord TX/RX Channel 1~16, Off 3 p. 60

Cho Chord Octave TX 3~0~3 0 p. 61

orC Orchestra/Organ TX/RX Channel 1~16, Off 4 p. 61

oro Orchestra/Organ Octave TX 3~0~3 0 p. 61

obs Orchestra Bass TX/RX Channel 1~16, Off 5 p. 61

obo Orchestra Bass Octave TX 3~0~3 0 p. 61

oCh Orchestra Chord TX/RX Channel 1~16, Off 6 p. 61

oCo Orchestra Chord Octave TX 3~0~3 0 p. 61

ofb Orchestra Free Bass TX/RX Channel 1~16, Off 7 p. 61

ofo Orchestra Free Bass Octave TX 3~0~3 0 p. 61

bCh Basic Channel TX/RX 1~16, Off 13 p. 61

PCh Program Change TX Off, On On p. 62

bEA Bellows Expression TX ALL Off, On Off p. 62

be1 Bellows Expression TX TREBLE Off, On Off p. 62

bE2 Bellows Expression TX BASS/CHORD/ FREE BASS

Off, On Off p. 62

bE3 Bellows Expression TX ORCHESTRA/ ORGAN

Off, On Off p. 62

bE4 Bellows Expression TX ORCHESTRA BASS Off, On Off p. 62

bE5 Bellows Expression TX ORCHESTRA CHORD

Off, On Off p. 62

bE6 Bellows Expression TX ORCHESTRA FREE BASS

Off, On Off p. 62

vel Velocity TX On, 1~127 On p. 62

bre Bellows TX Resolution 1~4 2 p. 63

Ufd USB function driver Gen, Ven Gen p. 63

*: Reset when you switch off the FR-1x.

8

Selecting the desired MIDI parameter V-Accordion

FR-1x GB.book Page 59 Tuesday, November 8, 2011 11:44 AM

Selecting the desired MIDI parameter

1. Press and hold the [SET] register to enter PARAMETER mode. The display shows the name of the last parameter you selected (AUd in our example).

2. Use treble register [3] or [4] (PARAM LIST) to select the desired parameter.

(Here, we selected the Chord TX/RX Channel param- eter.)

NOTE

Pressing registers [3] and [4] (PARAM LIST) simultaneously alternates between AUd (first parameter of the PARAME- TER group) and ESq (first parameter of the MIDI group). This may come in handy to close in on the parameter you need.

3. Use register [1] ( VALUE) or [2] (VALUE ) to set the desired MIDI channel.

To return to the last setting you saved for this parameter, press registers [1] and [2] simultaneously.

4. If you need to change another MIDI parame- ter, repeat steps 2 and 3.

5. If you want to use this change only tempo- rarily, press the [SET] register to leave this mode. Otherwise, proceed to save your changes:

Saving your changes 1. Press and hold the [SET] register until the

display looks as follows:

2. Press register [2] (VALUE ) to save your settings. The display now looks as follows:

If you dont want to save your changes, press [1] ( VALUE). The display briefly shows the no mes- sage.

3. Press the [USER PROGRAM] (ENTER) button to confirm your intention. The settings are stored internally and the display briefly shows the y.E.S. message (the three dots flash), then don when the settings are stored. Next, the display returns to the master page.

MIDI parameters External Sequencer This parameter is used to establish the FR-1xs MIDI communication when its USB COMPUTER port is connected to a computer..

No Select this setting if you want to play on the FR-1xs keyboards and transmit the MIDI data generated by your playing to an external device. In this case, the FR-1x does not receive MIDI data.

AUd

PIANO/GUITARWIND Chd

3

Value No, Yes

Default setting: No

Urt

yes

ESq

59

Connecting to MIDI devices

6

FR-1x V-Accordion

FR-1x_2_GB.fm Page 60 Wednesday, January 4, 2012 12:00 PM

r Yes

Select this setting if you want to receive MIDI data generated by an external device. If you select YES here, the FR-1xs sound source can no longer be played via its keyboards (Local Off). If you connect the FR-1xs USB COMPUTER port to a USB port of your computer and set the DAW/ sequencer software to Soft Thru, the notes you play on the keyboards will be transmitted to the FR-1xs sound source via the computer.

NOTE

See Communication via the USB COMPUTER port on p. 57 for the required connection.

Treble TX/RX channel This parameter allows you to define the MIDI channel for the Treble (accordion) section. The assignment set here applies both to the transmission (TX) and reception (RX) of MIDI data.

1~16 Specifies the treble accordions MIDI channel.

Off Select Off if the treble section should neither receive nor transmit MIDI data.

NOTE

Though it is perfectly possible to assign the same MIDI chan- nel to several sections, the result is usually disappointing and may lead to a lot of confusion.

Treble Octave Tx This parameter allows you to transpose the Note-on messages transmitted by the treble section up to three octaves up or down.

This can be used for songs where an accordion register of the treble section (for example) should be doubled by a piccolo flute played by an external module whose notes would be far too low if they were used as is. As stated above, each MIDI note has a unique number. This parameter allows you to add (or subtract) 12 (1 octave), 24 (2 octaves) or 36 (3 octaves) to (from) the note numbers generated by your playing.

Bass/Free Bass TX/RX Channel This parameter allows you to define the MIDI channel for the bass buttons or Free Bass (accordion) part, depending on which mode is currently active.

The assignment set here applies both to the transmis- sion (TX) and reception (RX) of MIDI data.

1~16 Specifies the bass or Free Bass accordions MIDI chan- nel.

Off Select this setting if the bass or Free Bass section should neither receive nor transmit MIDI data.

Bass/Free Bass Octave TX This parameter allows you to transpose the Note-on messages transmitted by the bass buttons or Free Bass section up to three octaves up or down.

Chord TX/RX Channel This parameter allows you to define the MIDI channel for the chord buttons when they are used to play the selected accordion register.

1~16 Specifies the chord parts MIDI channel.

Value 1~16, Off

Default setting: 1

USB connection

Data transmit- ted by the FR-1x

Soft Thru on

Data passed on by the computer to the FR-1xs sound source

trb

Value 3~0~3

Default setting: 0

Value 1~16, Off

Default setting: 2

Value 3~0~3

Default setting: 0

Value 1~16, Off

Default setting: 3

tro

bFr

bFo

Chd

0

MIDI parameters

V-Accordion

FR-1x_2_GB.fm Page 61 Wednesday, January 4, 2012 12:00 PM

Off Select this setting if the chord part should neither receive nor transmit MIDI data.

Chord Octave TX This parameter allows you to transpose the Note-on messages transmitted by the chord buttons up to three octaves up or down.

Orchestra/Organ TX/RX Channel This parameter allows you to set the MIDI channel for the orchestral/organ part.

1~16 Specifies the orchestral/organ parts MIDI channel.

Off Select this setting if the treble orchestral/organ part should neither receive nor transmit MIDI data.

Orchestra/Organ Octave TX This parameter allows you to transpose the Note-on messages transmitted by the Orchestra section.

Orchestra Bass TX/RX Channel This parameter allows you to define the MIDI channel for the ORCH BASS part.

1~16 Specifies the orchestral bass parts MIDI channel.

Off Select this setting if the orchestral bass part should neither receive nor transmit MIDI data.

Orchestra Bass Octave TX This parameter allows you to transpose the Note-on messages transmitted by the orchestral bass part.

Orchestra Chord TX/RX Channel This parameter allows you to define the MIDI channel for the orchestral chord part.

1~16 Specifies the orchestral chord parts MIDI channel.

Off Select this setting if the orchestral chord part should neither receive nor transmit MIDI data.

Orchestra Chord Octave TX This parameter allows you to transpose the Note-on messages transmitted by the orchestral chord part.

Orchestra Free Bass TX/RX Channel This parameter allows you to define the MIDI channel for the orchestral Free Bass part.

1~16 Specifies the orchestral Free Bass parts MIDI channel.

Off Select this setting if the orchestral Free Bass part should neither receive nor transmit MIDI data.

Orchestra Free Bass Octave TX This parameter allows you to transpose the Note-on messages transmitted by the orchestral Free Bass part.

Basic Channel TX/RX This parameter allows you to set the basic MIDI channel. The Basic Channel can be used for selecting Sets from an external MIDI device (using pro- gram change numbers). Please see MIDI implementa- tion on p. 72 for the program change numbers of the Sets.

The assignment set here applies both to the transmis- sion (TX) and reception (RX) of MIDI data.

Value 3~0~3

Default setting: 0

Value 1~16, Off

Default setting: 4

Value 3~0~3

Default setting: 0

Value 1~16, Off

Default setting: 5

Value 3~0~3

Default setting: 0

Cho

orC

oro

obs

obo

Value 1~16, Off

Default setting: 6

Value 3~0~3

Default setting: 0

Value 1~16, Off

Default setting: 7

Value 3~0~3

Default setting: 0

Value 1~16, Off

Default setting: 13

oCh

oCo

ofb

ofo

bCh

61

Connecting to MIDI devices

6

FR-1x V-Accordion

FR-1x_2_GB.fm Page 62 Wednesday, January 4, 2012 12:00 PM

r 1~16

Specifies the Basic Channel number.

Off Select this setting if no MIDI data should be trans- mitted/received on the Basic Channel.

Program Change TX The FR-1x transmits program changes when you select Sets and registers (on the MIDI channel assigned to the section for which you are selecting a different register). This is the first of a series of MIDI filters, i.e. parameters that allow you to specify whether or not the given MIDI type should be transmitted.

Off Select this setting if you dont want the FR-1x to transmit program change messages.

On Select this setting if the FR-1x should transmit pro- gram change messages.

Bellows Expression TX Filters You probably noticed that the strength/speed with which the bellows is pressed or pulled influences the sound which corresponds to an acoustic accordions response. This effect can be translated into a MIDI mes- sage most external instruments understand. The MIDI standard provides a message (control change) for remotely controlling the volume of an external instrument: CC11. It is chiefly used for expres- sion purposes (similar to the way in which a guitarist or organ player uses a volume pedal). The FR-1x can filter expression messages for the follow- ing sections:

Bellows Expression TX ALL This function allows you to set all fil- ters (bE1~bE6) to Off or On. It acts like a master switch.

Bellows Expression TX TREBLE Filters (suppresses) expression mes- sages for the treble accordion chan- nel.

Bellows Expression TX BASS/ CHORD/FREE BASS Filters (suppresses) expression mes- sages for the bass/chord/free bass accordion channel.

Bellows Expression TX ORCHESTRA/ ORGAN Filters (suppresses) expression mes- sages for the treble orchestra/organ channel.

Bellows Expression TX ORCHESTRA BASS Filters (suppresses) expression mes- sages for the orchestral bass channel.

Bellows Expression TX ORCHESTRA CHORD Filters (suppresses) expression mes- sages for the orchestral chord channel.

Bellows Expression TX ORCHESTRA FREE BASS Filters (suppresses) expression mes- sages for the orchestral free bass channel.

Off Select this setting if you dont want the selected sec- tion to transmit expression messages.

On Select this setting if the selected section should transmit expression messages.

Velocity TX Your FR-1x is velocity sensitive. That is a very learned term for the fact that the volume and brightness of the notes you play on the treble or bass keyboard depend on how hard (or fast) you press the buttons. Velocity informa- tion is transmitted via MIDI. This parameter allows you to specify whether you want to transmit fixed or dynamic velocity values (i.e. the values translating how hard/fast you press a key or but- ton).

On Select this setting if you want to transmit MIDI velocity values proportional to the key pressure.

1~127 Specifies the fixed velocity value to be transmitted for all notes.

NOTE

Fixed velocity values can be useful for playing organ sounds on an external module.

Value Off, On

Default setting: On

PCh

bEA

bE1

bE2

bE3

Value Off, On

Default setting: Off

Value On, 1~127

Default setting: On

bE4

bE5

bE6

vEL

2

MIDI parameters V-Accordion

FR-1x GB.book Page 63 Tuesday, November 8, 2011 11:44 AM

Bellows TX Resolution This parameter allows you to specify how many data the FR-1xs bellows may transmit for expression purposes.

1: Represents the highest bellows resolution (double- byte resolution).

2: Represents a high bellows resolution.

3: Represents the normal bellows resolution.

4: Represents the lowest (coarsest) bellows resolu- tion.

NOTE

If the external sequencer you work with displays a MIDI buffer overflow message, select a lower resolution. If your sequencer accepts the complete data amount, use the 4 setting, because it will lead to even more nuances being captured.

USB Function driver The FR-1xs USB COMPUTER port can be connected to a USB port on your com- puter. Doing so allows you to transmit MIDI data to the computer (which can be recorded using sequencer software) and to receive MIDI data from the computer. Normally, you dont need to install a driver in order to connect the FR-1x to your computer. However, if some problem occurs, or if the performance is poor, using the Roland original driver may solve the problem. To do so, first specify the USB driver you want to use (see below), and then install the driver on your com- puter. .

NOTE

For details on downloading and installing the Roland original driver, refer to the Roland website: http://www.roland.com/

Gen (generic) Choose this if you want to use the standard USB driver that was included with your computer. Nor- mally, you should use this mode.

Ven (vendor) Choose this if you want to use a USB driver down- loaded from the Roland website (www.roland.com).

Caution To avoid the risk of malfunction and/or damage to

external speakers, always turn the volume all the way down and switch off the power on all devices before you make any connections.

Only MIDI data can be transmitted and received via USB. Audio data cannot be transmitted or received.

Switch on the power to the FR-1x before you start up the MIDI application on your computer. Never turn the FR-1xs power on/off while your MIDI application is running.

Value 1~4

Default setting: 2

Value Gen, Ven

Default setting: Gen

brE

Ufd

63

Restoring the factory defaults

6

FR-1x V-Accordion

FR-1x GB.book Page 64 Tuesday, November 8, 2011 11:44 AM

r 15. Restoring the factory defaults

You can reset the FR-1x to its factory settings, which means that your own Global settings are replaced by the settings the FR-1x contained when you first got it. You may wish to archive your settings before initializing the FR-1x (see Sav- ing User Program memories to USB memory (optional) on p. 40).

Loading all factory settings 1. Switch on the FR-1x while holding down the

treble registers [3] and [4].

The display changes to:

When all settings have been initialized, the display briefly shows the following message:

2. Switch off the FR-1x, then switch it back on again. The FR-1x now again sounds and behaves like when you first bought it.

Restoring the User Sets to their factory defaults This function allows you to restore the factory settings of one of the four User Set memories (see also page 24).

1. Press and hold down the [SET] register.

The display shows the name of the last parameter you selected.

2. Use treble register [3] or [4] (PARAM LIST) to select UrC.

FCt

don

PIANO/GUITARWIND UrC

4

Restoring the User Sets to their factory defaults V-Accordion

FR-1x GB.book Page 65 Tuesday, November 8, 2011 11:44 AM

3. Use treble register [1] ( VALUE) or [2] (VALUE ) to select a User Set memory (U1~U4).

NOTE

If you change your mind about restoring a factory Set, press the [SET] register to abort the operation.

4. Press the [USER PROGRAM] (ENTER) button to confirm your selection.

The display shows rCu (recovering), then don (Done), after which the FR-1x returns to the main page.

U 1

65

Troubleshooting

6

FR-1x V-Accordion

FR-1x_2_GB.fm Page 66 Wednesday, January 4, 2012 12:01 PM

r 16. Troubleshooting

This section provides an overview of points to check and actions to take when the FR-1x does not function as you expect. Feel free to contact your Roland dealer if your issue remains unsolved after reading through this section.

No sound Did you turn the [VOL] knob all the way to the

small dot? Set it to a higher value.

Did you select an extreme Treble/Bass&Chord Balance value? Choosing b63 (or t63) means that you wont hear the treble (or bass & chord) section. See p. 45.

Are you moving the bellows while triggering accordion sounds? The treble and bass/free bass sections only produce sound if you move the bellows while playing notes (like on an acoustic accordion).

No sound is heard when an external amplifier is connected Did you switch on the connected amplifier?

Please check this.

Did you connect the audio cables to the correct sockets? If so, check the cables for possible damage.

No sound when you play on the treble keyboard You may have muted the treble section. See Switch- ing off the treble section on p. 27 for how to acti- vate it again.

No sound when you play on the bass keyboard You may have muted the bass/chord section. See Switching off the bass and/or chord section on p. 30 for how to activate it again.

No sound and the display shows --- Did you set the External Sequencer parameter

to YES? In that case, the FR-1x only responds to MIDI mes- sages received via its USB COMPUTER portnot the notes you play on its keyboards. Set the parameter to no (page 59).

No power Did you disconnect the adapter?

Connect the supplied adapter, or install optional bat- teries.

Did the FR-1x go off after several seconds? The Auto Off function may be active. Set it to Off (page 55).

The FR-1x does not respond to your playing Did you set the External Sequencer parameter

to YES? In that case, the FR-1x only responds to MIDI mes- sages received via its USB COMPUTER portnot the notes you play on its keyboards. Set the parameter to no (page 59).

Are you moving the bellows while triggering accordion sounds? The treble and bass/free bass sections only produce sound if you move the bellows while playing notes (like on an acoustic accordion).

Issues related to the bass buttons Why do the bass buttons only provide three

chord rows? Because you set the Bass & Chord Mode parameter to 2, 3, 4 or 5 (page 53). Set it to 1.

Why cant I play diminished chords using the bass buttons? Because you set the Bass & Chord Mode parameter to 2, 3, 4 or 5 (page 53). Set it to 1.

In Free Bass mode, the bass buttons play the wrong notes. You may have changed the Free Bass Mode setting. Be sure to select the system that best suits your play- ing style (page 51).

MIDI-related issues What MIDI channels does the FR-1x use by

default? See the table on page 56.

The FR-1x does not change sounds when my sequencer transmits program change numbers. The program change number is probably outside the range of the FR-1xs registers (see Program change messages on p. 72). Such excess program numbers are ignored by the FR-1x.

The FR-1x does not receive the MIDI messages I recorded for it. Thats because the External Sequencer parameter is currently set to no. Set it to YES (page 59).

The external sequencer keeps displaying a MIDI Buffer Overflow message The bellows sends too many data at once (its data are transmitted on five channels simultaneously). Select a different setting (2 or 1). This leads to a coarser resolution, and maybe to audible steps, but at least, your sequencer will be able to record the data. See Bellows TX Resolution on p. 63.

6

Troubleshooting V-Accordion

FR-1x GB.book Page 67 Tuesday, November 8, 2011 11:44 AM

Other issues Cant read the/write to USB memory

Are you using a USB memory made by another man- ufacturer than Roland? Use a USB memory sold by Roland (M-UF-series).

The bellows exhibits an erratic behavior If the bellows doesnt work as expected, causing notes to sound even while it is not moved, its sensors may need resetting. To do so, close the bellows, switch off the FR-1x, then press and hold the ORCHESTRAL [BASS] and [CHORD/ FREE BASS] buttons while switching the FR-1x back on. After a few seconds, the display shows the don message (Done) and then returns to the main page. If this operation doesnt solve the problem, contact your Roland dealer.

67

Error messages

6

FR-1x V-Accordion

FR-1x GB.book Page 68 Tuesday, November 8, 2011 11:44 AM

r 17. Error messages

The FR-1x may display one of the following messages to signal that it has detected an error. In that case, please read the following and take the appropriate action.

Message Meaning Action

E01 The FR-1x already contains these sounds The sound set you wanted to load already resides in the FR-1xs internal memory. See Loading new sounds from a USB memory (optional) on p. 42.

E02 Missing sound The User Set (1~4) you recalled requires a sound that the FR-1x no longer contains.

E03 File format error The file you want to load appears to be corrupt.

E04 USB read/write error

1) The USB memory is full. Use a different USB memory or delete files you no longer need. 2) You removed the USB memory while the FR-1x was accessing it. Connect it to the FR-1xs USB port. 3) The USB memory you connected is not properly formatted or not compatible. 4) The data could not be written to the USB memory or the file you selected cannot be read.

E05 Write protected The USB memory you connected is write protected. See the manual that came with the storage device for how to disable its protection.

E06 Invalid mp3 or WAV file The FR-1x doesnt recognize the selected audio file. See About audio files on p. 32 for the supported file types.

E07 Internal error The last operation failed. Please perform it again. If the error persists, please contact your Roland dealer or Roland distrib- utor (see Information on page 75).

8

Specications

V-Accordion

r

FR-1x_2_GB.fm Page 69 Wednesday, January 4, 2012 11:57 AM

18. Specifications

Keyboards

Bellows New sensor for the detection of bellows pressure (high-res- olution pressure sensor) Bellows resistance regulator: wheel with fine adjustment

Sound source Max polyphony: 128 voices Wave ROM: 64MB of waveforms (8+8MB expansion sounds) Tones: 16 accordion Sets (4 User Sets), each including: 14 treble registers, 7 bass registers, 7 free bass registers, 7 Orchestra Bass registers, 7 Orchestra Chord registers, 7 Orchestra Free Bass registers, 16 orchestral sounds, 4 organ sounds with slow/fast Rotary effect Treble reed footages: 7 Bass reed footages: 5 Chord reed footages: 3 Free bass reed footages: 2

PBM (Physical Behavior Modeling) Noises: stopping-reed growl, closing valve noise, left but- ton noise Individual reed simulation: Hysteresis Threshold, Expression Curve, Pressure-Variant Filter, Pressure-Variant Pitch Devi- ation Reed sound wave switching: by bellows acceleration, by note repetition speed Bellows opening/closing sound change: by bellows open- ing/closing detection

Musette tuning Micro tuning presets: 16 (Off, Dry, Classic, F-Folk, American L/H, North Europe, German L/H, D-Folk L/H, Alpine, Italian L/ H, French, Scottish)

Effects Reverb: 8 types, Chorus: 8 types, Rotary (Slow/Fast) for organ sounds

Panel controls Knobs: VOL Registers and buttons: SET register, 4 treble registers, 3 bass registers, ORCHESTRA and ORGAN buttons, USER PROGRAM button, ORCHESTRAL BASS and CHORD/ FREE BASS buttons, FREE BASS button, [] and [] but- tons, DRUM button, POWER button

Audio player Plays back mp3 and WAV files on a USB memory

Operation modes ORCHESTRA/ORGAN modes: Solo, Dual Bass & Chord modes: 2 Bass Rows, 3 Bass Rows A-7th, 3 Bass Rows A-5dim, 3 Bass Rows B-7th, 3 Bass Rows B- 5dim, 3 Bass Rows Bx-7th, 3 Bs Row Belgium Free Bass modes: Minor 3rd, Bajan, Fifth, N. Europe, Finnish Bass-to-Treble mode: On/off Bass & Chord with drum/percussion sounds: On/off Octave: Down, 0, Up (for Treble and Organ/Orchestra) 8 User Program memories

Display 7 segments, 3 character (LED)

Rated power output 2 x 7 W RMS

Speakers 2 x 9 cm

Power supply AC adaptor (PSB-1U) Batteries (AA-type rechargeable Ni-MH x 8), not included

Current draw 1800 mA

Expected battery life under continuous use (using Ni-MH 2000mAh batteries):

* Actual battery life varies according to usage conditions, the quality of the batteries and the number of charging cycles. Be sure to only use rechargeable Ni-MH batteries.

Connectors OUTPUT jacks (L/Mono, R/Mono): 1/4 phone type PHONES jack: stereo 1/4 phone type MIDI connector (OUT) USB COMPUTER connector: type B

Piano-type Right hand: 26 keys, velocity sensitive Left hand: 72 velocity-sensitive bass buttons Modes: Standard, Free Bass, Orch.Bass, Orch.Chord, Orch. Free Bass

Button-type Right hand: 62 buttons, velocity

sensitive Treble modes: C Griff Europe, C Griff 2, B Griff Bajan, B Griff Fin, D Griff 1, D Griff 2 Left hand: 72 velocity-sensitive bass buttons Modes: Standard, Free Bass, Orch.Bass, Orch.Chord, Orch. Free Bass

WAV files 16-bit linear Sampling frequency: 44.1 kHz Stereo/mono

mp3 files MPEG-1 Audio Layer 3 Sampling frequency: 44.1 kHz Bit rate: 32/40/48/56/64/80/96/112/128/ 160/192/224/256/320 kbps, VBR (variable bit rate)

Speakers on 5* hours

Speakers off 8* hours

69

Specications

7

FR-1x V-Accordion

FR-1x_2_GB.fm Page 70 Wednesday, December 7, 2011 12:16 PM

r USB MEMORY connector: type A DC IN connector (use Roland PSB-1U AC adaptor only)

Dimensions FR-1x piano type: 405 (H) x 365 (W) x 195 (D) mm 16 (H) x 14-3/8 (W) x 7-11/16 (D) inches

FR-1x button type: 380 (H) x 365 (W) x 195 (D) mm 15 (H) x 14-3/8 (W) x 7-11/16 (D) inches

Weight FR-1x piano type: 6.5 kg, 14 lbs 6 oz FR-1x button type: 6.4 kg, 14 lbs 2 oz

Supplied accessories PSB-1U AC adaptor Power cord (for connecting the AC adaptor) Owners Manual Reference caps for the bass buttons Reference caps for the treble buttons (only for FR-1x button type) Straps Strip for securing the adapter, MIDI and/or audio cables

Options Accordion soft bag USB flash memory (M-UF-series) AMC-3 audio/MIDI cable AAP-1 music rest and throne

NOTE

In the interest of product improvement, the specifications and/or appearance of this unit are subject to change with- out prior notice.

0

Appendix V-Accordion r

FR-1x GB.book Page 71 Tuesday, November 8, 2011 11:44 AM

19. Appendix

Ways in which the FR-1x displays alphabetic characters of file names Character A B C D E F G H I J K L M

Display a b C d e f g h i j k l m

Character N O P Q R S T U V W X Y Z

Display n o p q r s t u v w x y z

71

Appendix

7

FR-1x V-Accordion

FR-1x GB.book Page 72 Tuesday, November 8, 2011 11:44 AM

r MIDI implementation

1. Received data Channel Voice Messages Note off

Note on

Control Change The value specified by a Control Change message is not reset by a Program

Change, etc.

Bank Select (Controller number 0, 32)

Only for Free Bass.

Expression (Controller number 11)

This adjusts the volume of a Part. It can be used independently from Volume (CC07) messages. Expression messages are used for musical expression within a performance, e.g., expression pedal movements, crescendo and decrescendo.

Program Change

System Realtime Messages Active Sensing

When Active Sensing is received, the FR-1x starts monitoring the intervals of all further messages. While monitoring, if the interval between messages exceeds 420 ms, the same processing will be carried out as when All Sounds Off, All Notes Off and Reset All Controllers are received, and message interval monitoring will be halted.

2. Transmitted data Channel Voice Messages Note off

Note on

Control Change Bank Select (Controller number 0, 32)

Modulation number (Controller number 01)

Volume (Controller number 7)

Volume messages are used to adjust the level of the Orchestra, Organ and Drum parts.

Pan (Controller number 10)

The stereo position can be adjusted in 127 steps.

Expression (Controller number 11)

This adjusts the volume of a Part. Expression messages are used for musical ex- pression within a performance, e.g., expression pedal movements, crescendo and decrescendo.

Program Change

Pitch Bend Change

Effect 1 (Reverb Send level; Controller number 91)

This message adjusts the Reverb Send level of all parts.

Effect 3 (Chorus Send level; Controller number 91)

This message adjusts the Chorus Send level of all parts.

System Realtime Messages Active Sensing

Start

Stop

3. Program change messages

Status 2nd byte 3rd byte 8nH kkH vvH

n = MIDI channel number: 0H~FH (Ch.1~16) kk = note number: 00H~7FH (0~127) vv = note off velocity: 00H~7FH (0~127)

Status 2nd byte 3rd byte 9nH kkH vvH

n = MIDI channel number: 0H~FH (Ch.1~16) kk = note number: 00H~7FH (0~127) vv = note on velocity: 01H~7FH (1~127)

Status 2nd byte 3rd byte BnH 00H mmH BnH 20H llH

n = MIDI channel number: 0H~FH (Ch.1~16) mm = Bank number MSB: 00H~7FH ll = Bank number LSB: 00H~7FH

Status 2nd byte 3rd byte BnH 0BH vvH

n = MIDI channel number: 0H~FH (Ch.1~16) vv = Expression: 00H~7FH (0~127)

Status 2nd byte CnH ppH

n = MIDI channel number: 0H~FH (Ch.1~16) pp = Program number: See 3. Program change messages.

For the Sets, see SET RX on p. 73

Status FEH

Status 2nd byte 3rd byte 8nH kkH vvH

n = MIDI channel number: 0H~FH (Ch.1~16) kk = note number: 00H~7FH (0~127) vv = note off velocity: 00H~7FH (0~127)

Status 2nd byte 3rd byte 9nH kkH vvH

n = MIDI channel number: 0H~FH (Ch.1~16) kk = note number: 00H~7FH (0~127) vv = note on velocity: 01H~7FH (1~127)

Status 2nd byte 3rd byte BnH 00H mmH BnH 20H llH

n = MIDI channel number: 0H~FH (Ch.1~16) mm = Bank number MSB: 00H~7FH ll = Bank number LSB: 00H~7FH

Status 2nd byte 3rd byte BnH 01H vvH

n = MIDI channel number: 0H~FH (Ch.1~16) vv = Modulation depth: 00H~7FH (0~127)

Status 2nd byte 3rd byte BnH 07H vvH

n = MIDI channel number: 0H~FH (Ch.1~16) vv = Volume: 00H~7FH (0~127)

Status 2nd byte 3rd byte BnH 0AH vvH

n = MIDI channel number: 0H~FH (Ch.1~16) vv = Pan: 00H~40H~7FH (0~127) (leftcenterright);

Initial value: 40H (center)

Status 2nd byte 3rd byte BnH 0BH vvH

n = MIDI channel number: 0H~FH (Ch.1~16) vv = Expression: 00H~7FH (0~127)

Status 2nd byte CnH ppH

n = MIDI channel number: 0H~FH (Ch.1~16) pp = Program number: 00H~7FH: program no. 1~128

Status 2nd byte 3rd byte EnH llH mmH

n = MIDI channel number: 0H~FH (Ch.1~16) mm, ll= Pitch Bend value 00 00H~40 00H~7F 7FH (8192~0~+8191)

Status 2nd byte 3rd byte BnH 5BH vvH

n = MIDI channel number: 0H~FH (Ch.1~16) vv = Reverb Send level: 00H~7FH (0~127)

Status 2nd byte 3rd byte BnH 5DH vvH

n = MIDI channel number: 0H~FH (Ch.1~16) vv = Reverb Send level: 00H~7FH (0~127)

Status FEH Transmitted about every 250ms.

Status FAH This message is transmitted when the [METRONOME] switch is

pressed after assigning the 2 option to the MFn parameter.

Status FCH This message is transmitted when the [METRONOME] switch is

pressed after assigning the 2 option to the MFn parameter.

CC00 CC32 Program Change

Register Name

TREBLE REGISTER TX/RX 0 0 1 1a Bassoon 0 0 2 1b Bandon 0 0 3 1c Cello 0 0 4 1d Harmon 0 0 8 2a Master 0 0 5 2b Organ 0 0 6 2c Accord 0 0 7 2d Violin

2

MIDI implementation V-Accordion r

FR-1x GB.book Page 73 Tuesday, November 8, 2011 11:44 AM

CC00 CC32 Program Change

Register Name

0 0 12 3a Clarinet 0 0 9 3b Musette 0 0 10 3c Celeste 0 0 11 3d Tremolo 0 0 14 4a Piccolo 0 0 13 4b Oboe

ORCHESTRA (Treble) TX/RX 0 0 1 1a Strings 0 0 2 1b JazzScat1 0 0 3 1c JazzDoos 0 0 4 1d Str&Choir 0 0 5 2a Twin Trump 0 0 6 2b Trombone 0 0 7 2c French Horn 0 0 8 2d Brass 0 0 9 3a Flute1 0 0 10 3b Tenor Sax2 0 0 11 3c Clarinet 0 0 12 3d Oboe 0 0 13 4a Ac. Piano 0 0 14 4b Ac. Guitar 0 0 15 4c Mandolin 0 0 16 4d HarpsStr

ORGAN (Treble) TX/RX (slow rotary efect) 0 0 27 1 Full 0 0 28 2 Jazz 0 0 29 3 R&B 0 0 30 4 Perc.

ORGAN (Treble) TX/RX (fast rotary effect) 0 0 37 1 Full Fast 0 0 38 2 Jazz Fast 0 0 39 3 R&B Fast 0 0 40 4 Perc. Fast

BASS AND CHORD REGISTER TX/RX 0 0 5 1a 8'/4'/2' 0 0 3 1b 8-4' 0 0 4 2a 16'/8'/8-4'/4'/2' 0 0 6 2b 16'/8'/8-4' 0 0 7 3a 16'/2' 0 0 2 3b 4' 0 0 1 3c 2'

FREE BASS REGISTER TX/RX 0 1 1 1a Low 0 1 4 1b Low +High Low 0 1 3 2a Low + High 0 1 5 2b Low Low + High 0 1 2 3a High 0 1 6 3b High Low +

High 0 1 7 3c Low High

ORCHESTRA BASS TX/RX 0 0 1 1a Acoustic 0 0 2 1b Fingered 0 0 3 2a Bowed 0 0 4 2b JazzPedalVTW 0 0 5 3a Tuba Mix 0 0 6 3b Tuba 0 0 7 3c Fretless

ORCHESTRA CHORD TX/RX 0 0 1 1a St. Strings 0 0 2 1b Jazz Doos 0 0 3 2a Jazz VTW 0 0 4 2b R&B VTW 0 0 5 3a Steel Gtr 0 0 6 3b Ac. Guitar 0 0 7 3c Ac. Piano

ORCHESTRA FREE BASS TX/RX 0 0 1 1a Strings 0 0 2 1b Jazz Doos 0 0 3 2a Jazz VTW 0 0 4 2b Clarinet 0 0 5 3a Ac. Guitar 0 0 6 3b Ac. Piano 0 0 7 3c Oboe

CC00 CC32 Program Change

Register Name

SET RX 1 CLASSIC

0 0 1 11 Concerto 0 0 2 12 Classic 0 0 3 13 Bajan 0 0 4 14 I Scala

2 JAZZ 0 0 5 21 Jazz 0 0 6 22 FJazz 0 0 7 23 Bandoneon 0 0 8 24 Studio

3 WORLD 0 0 9 31 I Folk 0 0 10 32 F Folk 0 0 11 33 D Folk 0 0 12 34 SP Folk

4 USER 0 0 13 U1 Alpine 0 0 14 U2 Cajun 0 0 15 U3 Tex Mex 0 0 16 U3 Scottish

73

Appendix

7

FR-1x V-Accordion

FR-1x GB.book Page 74 Tuesday, November 8, 2011 11:44 AM

r MIDI Implementation Chart [V-Accordion] Date: July 2011 Model: FR-1x Version: 1.00

Function... Transmitted Recognized Remarks

Basic Channel

Default Changed

1~16 1~16, Off

1~16 1~16, Off

7 Parts: 1= Treble, 2= Bass/Free Bass, 3= Chord, 4= Orchestra, 5= Orchestra Bass, 6= Orchestra Chord, 7= Orchestra Free Bass, 10 Drum Set (note messages) 1 Logical part: 13= Basic MIDI Channel for SET change

Mode Default Message Altered

Mode 3 ***** *****

Mode 3 *****

Note Number True Voice

0~127 *1 *****

0~127 0~127

Velocity Note ON Note OFF

O O

O O

After Touch

Keys Chs

X X

X X

Pitch Bend O X

Control Change

0,32 1 7

10 11 64 91 93

O *1 O O O O X O O

O X X X O X X X

Bank Select Modulation Volume Panpot Expression Hold 1 Reverb Send Chorus Send

Program Change True #

O *1 0~39

O 0~39

Program Number 1~40 transmitted See the table under Program change messages on p. 72. See SET RX on p. 73. for the Sets

System Exclusive X X

System Common

Song Position Pointer Song Sel Tune

X X X

X X X

System Real Time

Clock Commands

X O *2

X X

Aux Messages

All Sounds Off Reset All Controllers Local On/Off All Notes Off Active Sense Reset

X X X O O X

X X X X O X

Notes *1 O X is selectable *2 Transmit Start (FA) and Stop (FC)

Mode 1: OMNI ON, POLY Mode 3: OMNI OFF, POLY

Mode 2: OMNI ON, MONO Mode 4: OMNI OFF, MONO

O: Yes X: No

4

Information V-Accordion

FR-1x GB.book Page 75 Tuesday, November 8, 2011 11:44 AM

20. Information

75

Index |

7

FR-1x V-Accordion

FR-1x GB.book Page 76 Tuesday, November 8, 2011 11:44 AM

r 21. Index

A Accompaniment . . . . . . . . . . . . . . . . . . . .32 Adaptor . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Alpine . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 American. . . . . . . . . . . . . . . . . . . . . . . . . . .35 APO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 AUd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 Audio files . . . . . . . . . . . . . . . . . . . . . . 32, 45 Audio Level . . . . . . . . . . . . . . . . . . . . . . . . .45 AUL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 Auto Off . . . . . . . . . . . . . . . . . . . . . . . . . . .55

B B Griff . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 Basic Channel. . . . . . . . . . . . . . . . . . . . . . .61 Bass

& Chord Mode. . . . . . . . . . . . . . . . . . . . .53 Button Noise . . . . . . . . . . . . . . . . . . . . . .46 Panel functions . . . . . . . . . . . . . . . . . . . .13 Reed Growl . . . . . . . . . . . . . . . . . . . . . . .46 Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 Using. . . . . . . . . . . . . . . . . . . . . . . . . . . . .28

Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Installing . . . . . . . . . . . . . . . . . . . . . . . . .16

bbn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 bCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 bcM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 Bellows

Curve . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 Expression TX. . . . . . . . . . . . . . . . . . . . . .62 Resistance regulator . . . . . . . . . . . . . . .11 TX Resolution . . . . . . . . . . . . . . . . . . . . .63

bES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62 bFo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 bFr. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 bLC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 brE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63 brG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 brg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 btl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 Button layout. . . . . . . . . . . . . . . . . . . . . . .49 Button Noise . . . . . . . . . . . . . . . . . . . 46, 47

C C Griff . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 Chd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 Cho . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 Chord. . . . . . . . . . . . . . . . . . . . . . . . . . 28, 56

TX/RX Channel. . . . . . . . . . . . . . . . . . . . .60 Chorus . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 CHr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 Classic . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 Connections . . . . . . . . . . . . . . . . . . . . . . . .17 Curve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49

D D Griff . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 DC IN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 Demo songs . . . . . . . . . . . . . . . . . . . . . . . .23

det . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 Detune. . . . . . . . . . . . . . . . . . . . . . . . . 35, 45 D-Folk . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 dn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 dof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 Driver . . . . . . . . . . . . . . . . . . . . . . . . . . 57, 63 drl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 drs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 Drum Level . . . . . . . . . . . . . . . . . . . . . . . . .46 Drum Set . . . . . . . . . . . . . . . . . . . . . . . . . . .46 Dry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 Dynamics. . . . . . . . . . . . . . . . . . . . . . . . . . .48

E Editing . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43 Effect . . . . . . . . . . . . . . . . . . . . . . . . . . 47, 48

Rotary . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 Energy saving . . . . . . . . . . . . . . . . . . . . . . .55 ESq . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59 External Sequencer . . . . . . . . . . . . . . . . . .59

F Factory Setup . . . . . . . . . . . . . . . . . . . . . . .64 FbM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51 Fbn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 F-Folk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 Fin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 Flanger. . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 Fns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 Free Bass . . . . . . . . . . . . . . . . . . . . . . . . . . .31

Button Noise . . . . . . . . . . . . . . . . . . . . . .47 Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . .51 Panel functions . . . . . . . . . . . . . . . . . . . .13 Reed Growl . . . . . . . . . . . . . . . . . . . . . . .47

French . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 FrG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 Fty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64 FUL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 Functon Switch . . . . . . . . . . . . . . . . . . . . .53

G German . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 Growl . . . . . . . . . . . . . . . . . . . . . . . . . . 46, 47

H Hall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 Headphones . . . . . . . . . . . . . . . . . . . . 14, 21

I Initialize. . . . . . . . . . . . . . . . . . . . . . . . . . . .64 Italian. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35

L Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46

M Master Tune . . . . . . . . . . . . . . . . . . . . . . . .45 Memories . . . . . . . . . . . . . . . . . . . . . . . . . .37 Memorize . . . . . . . . . . . . . . . . . . . . . . . . . .37

Metronome Function . . . . . . . . . . . . . . . . . . . . . . . . . .47 Tempo . . . . . . . . . . . . . . . . . . . . . . . . . . . .47

MFn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 MIDI

Channels. . . . . . . . . . . . . . . . . . . . . . 56, 60 Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . .62 Implementation . . . . . . . . . . . . . . . . . . .72 List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59 USB . . . . . . . . . . . . . . . . . . . . . . . . . . 57, 63

Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 mp3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 Mtp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 MtS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 Mts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 Musette Detune . . . . . . . . . . . . . . . . . 35, 45

N North Eur . . . . . . . . . . . . . . . . . . . . . . . . . .35

O o t. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 obs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 obt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 Octave

Bass/Free Bass . . . . . . . . . . . . . . . . . . . . .60 Chord . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 Orchestra . . . . . . . . . . . . . . . . . . . . . . . . .61 Orchestra Bass . . . . . . . . . . . . . . . . . . . . .61 Orchestra Chord . . . . . . . . . . . . . . . . . . .61 Orchestra Free Bass . . . . . . . . . . . . . . . .61 Treble . . . . . . . . . . . . . . . . . . . . . . . . . . . .60

orC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 Orchestra. . . . . . . . . . . . . . . . . . . . . . . . . . .27

Bass TX/RX Channel . . . . . . . . . . . . . . . .61 Chord TX/RX Channel . . . . . . . . . . . . . . .61 Free Bass TX/RX Channel . . . . . . . . . . . .61 Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 TX/RX Channel . . . . . . . . . . . . . . . . . . . . .61 Velocity . . . . . . . . . . . . . . . . . . . . . . . . . . .48 Volume . . . . . . . . . . . . . . . . . . . . . . . . . . .46

Organ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46

oro. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 Output Level Attenuation. . . . . . . . . . . . .55

P Pan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49

Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 Panel functions . . . . . . . . . . . . . . . . . . . . .12 PCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62 Percussion . . . . . . . . . . . . . . . . . . . . . . . . . .46 PHONES . . . . . . . . . . . . . . . . . . . . . . . . 14, 21 Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 Playback. . . . . . . . . . . . . . . . . . . . . . . . . . . .32 Program Change TX. . . . . . . . . . . . . . . . . .62

R Recover . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 Reed Growl . . . . . . . . . . . . . . . . . . . . . 46, 47

6

V-Accordion r

FR-1x GB.book Page 77 Tuesday, November 8, 2011 11:44 AM

Register Bass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Treble . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Registration memories . . . . . . . . . . . . . . .37 Resetting. . . . . . . . . . . . . . . . . . . . . . . . . . .64 rEv . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 Reverb . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 Right hand . . . . . . . . . . . . . . . . . . . . . . . . .26 Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 Rotary . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27

S SAU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 Save . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 Scottish . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24

Program change . . . . . . . . . . . . . . . . . . .61 Speaker Mode. . . . . . . . . . . . . . . . . . . . . . .55 Specifications . . . . . . . . . . . . . . . . . . . . . . .69 StE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 Stereo Width . . . . . . . . . . . . . . . . . . . . . . .49 Straps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Switching on/off . . . . . . . . . . . . . . . . . . . .21

T Time Signature . . . . . . . . . . . . . . . . . . . . . .47 Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 Transpose . . . . . . . . . . . . . . . . . . . . . . . . . .45 trb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 Treble . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 Panel functions . . . . . . . . . . . . . . . . . . . .12 Using. . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 Valve Noise . . . . . . . . . . . . . . . . . . . . . . .46

Treble/Bass&Chord Balance . . . . . . . . . . .45 trM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 trn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 tro. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 trP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 tUn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45

U Ufd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63 UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 USB . . . . . . . . . . . . . . . . . . . . . . . . . . . 40, 57

Driver . . . . . . . . . . . . . . . . . . . . . . . . 57, 63 MIDI . . . . . . . . . . . . . . . . . . . . . . . . . 57, 63

User Program . . . . . . . . . . . . . . . . . . . . . . .37 User Set . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 Ust . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41

V Valve noise . . . . . . . . . . . . . . . . . . . . . . . . .46 vEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62 Velocity . . . . . . . . . . . . . . . . . . . . . . . . . . . .48

TX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62 Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . .46

Headphones. . . . . . . . . . . . . . . . . . . . . . .21 Orchestra . . . . . . . . . . . . . . . . . . . . . . . . .46

W WAV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 Write . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37

77

78

r FR-1x V-Accordion

MEMO

FR-1x GB.book Page 78 Tuesday, November 8, 2011 11:44 AM

* 5 1 0 0 0 4 2 6 8 1 - 0 2 *

For EU Countries

For China

<

Manualsnet FAQs

If you want to find out how the FR-1X Roland works, you can view and download the Roland FR-1X Owner's Manual on the Manualsnet website.

Yes, we have the Owner's Manual for Roland FR-1X as well as other Roland manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Owner's Manual should include all the details that are needed to use a Roland FR-1X. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Roland FR-1X Owner's Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Roland FR-1X Owner's Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Roland FR-1X Owner's Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Roland FR-1X Owner's Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Roland FR-1X Owner's Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.