Introduction:

The MZ-100 is a 4 channel audio amplifier capable of delivering up to 25W RMS per channel. The Digital Signal Processor (DSP) constantly monitors the output signal and optimizes it for maximum fidelity. The onboard microcontroller communicates with external control panels and poly-planar source units to make a complete networked audio solution. The compact, water resistant design allows for flexible mounting possibilities, and makes it simple to expand the audio system capabilities on any vessel or land based application

Uses:

To add additional loudspeakers to a current audio system

To provide amplification for a separate audio zone

As a stand-alone system amplifier for any audio source

Features:

Custom Equalization for optimized sound

Digital Signal Optimization eliminates distortion and maximizes output

Waterproof, corrosion resistant enclosure

Connect up to 4 loudspeakers and 2 subwoofers

Supports Intercom feature

Supports wireless and wired remote control

Expandable for multi-zone use

Includes optional rotary volume knob

PO Box 409 Hanover, MD 21076 Tel (410) 761-4000 www.polyplanar.com

- 2 -

Controls, Input and Output Cables:

The switches and gain settings are located behind a watertight plug, which also lights up when the amplifier is on. Be sure to replace the plug when finished with adjustments

1) Input A Level. This rotary control selects the input sensitivity of the amplifiers RCA input (#4). Often referred to as Gain Control

2) Pilot Lamp: (Green) Illuminates when MZ100 is operating.

3) Equalization: These DIP switches are used to set one of eight different equalization settings as shown on page 5.

4) Input A: Stereo RCA audio input for connecting other audio devices

5) Volume Control: Plug for the waterproof remote volume control. When installed, this control will turn off the MZ100 Amp when turned all the way down.

6) Audio System Connection: This plug is used for hooking the MZ-100 to an extended poly-planar audio network using an RT20 System Router.

7) Control Panel Connection: This plug is used for hooking the MZ-100 to poly-planardisplays andcontrol panels.

Figure 6 Amplifier Switch and Gain settings

Left Panel View

PO Box 409 Hanover, MD 21076 Tel (410) 761-4000 www.polyplanar.com

- 3 -

Power and Speaker Connections: (Refer to diagram on page 4)

7) POWER The Black and Red wires should be connected directly to the 12 Volt battery, power supply or main fuse block using heavy gauge wire (AWG #14 or larger).

BLUE REMOTE WIRE turns on the amplifier. For stand alone or as a local booster amp, connect this to the remote wire of your receiver, an on/off toggle switch or Accessory circuit. As a Zone amplifier with an RD-44 or volume knob, connect this to 12V (Red wire).

8) SUBWOOFER CONNECTIONS: The Violet and Green wires connect to the subwoofers. (if used)

9) SPEAKER CONNECTIONS: The White and Gray Speaker wires connect to stereo pairs of loudspeakers. Make sure the EQ switches are set for the speakers you are using.

Minimum impedance per channel = 2 ohms

Pay close attention to polarity (black stripe = negative).

Unused speaker connectors should NOT be twisted together or grounded. Insulate the contacts and tie them off safely.

Right Panel View

Controls, Inputs & Outputs

(Continued)

PO Box 409 Hanover, MD 21076 Tel (410) 761-4000 www.polyplanar.com

- 4 -

Wire Color Description Red Battery (+), 12Vdc

Black Battery ( - ), Ground

Blue Remote Turn On, 12Vdc = ON White Left Channel (+)

White/Black Left Channel ( - )

Gray Right Channel (+)

Gray/Black Right Channel ( - )

Green Sub 1 Channel (+)

Green/Black Sub 1 Channel ( - )

Violet Sub 1 Channel (+)

Violet/Black Sub 1 Channel ( - )

Battery - Battery +

Speaker Outputs

PO Box 409 Hanover, MD 21076 Tel (410) 761-4000 www.polyplanar.com

- 5 -

Equalization Configurations: The EQ switches (See below) can be set in various configurations in order to accommodate the normal frequency variations found in speakers and installation acoustics. The MZ100 DSP Amp has the unique ability to accomplish this across the full audio spectrum. The chart below shows settings for the broad range of Poly Planar Speakers in Marine and Spa applications. Adding a Subwoofer will further enhance your audio experience.

Make sure the EQ switches are set for the speakers you are using.

When using other brands, use the settings based on similar sized applications.

Optimized for: MA3030, MA7500,MA800, MA9060 box speakers

MA3013,MA5104 or other small panel speakers in conjunction with MS55 or MS250 Subwoofer.

EQ 2

Optimized for: Platinum Series MA6500, MA6600 MA6800,

MA6900 or other similar speakers. Using a subwoofer is optional

EQ 3

Optimized for: Premium Series MA5106, MA5107, MA5950 or similar sized panel mount. Using a subwoofer optional.

EQ 4

Optimized for: Performance series MA4055, MA4056, MA4600

or other similar panel mount speaker. A subwoofer is recommended.

EQ 5 Optimized for: SPA applications using Flip-up or Popup speakers containing 3 drivers. Using a subwoofer is optional

EQ 6 Optimized for: SPA applications using MA7020 Popup speakers and MS-55 subwoofer

EQ 7 Optimized for: SPA applications using SP200 Popup speakers and MS-55 subwoofer

EQ 8 Optimized for: SPA applications using SB100 speakers and

MS-55 subwoofer.

EQ 1

PO Box 409 Hanover, MD 21076 Tel (410) 761-4000 www.polyplanar.com

- 6 -

Connecting the MZ-100 Input (Fixed Gain):

For operation without the optional external volume control, connect the amplifier inputs to the VARIABLE LINE OUT of your receiver using shielded RCA patch cables. In this case the amplifier volume will be determined by the volume setting of the source component.

Connecting the MZ-100 Input (Variable Gain):

For operation with the external volume control, connect the amplifier inputs to the PRE-AMP LINE OUT of your receiver using shielded RCA patch cables. The Pre-amp line output should be a fixed level output that is independent of the volume setting of the receiver.

To VARIABLE line output of receiver, TV, or other audio source.

Figure 4 - Input connections without Volume control

Figure 5 - Input connections with Volume control

Volume

Control

NOTE: The BLUE remote wire should be switched or

connected to an

accessory circuit

NOTE: The BLUE remote wire should be tied to 12V (Red wire). The amp can be turned off by turning the volume knob all the

way down.

PO Box 409 Hanover, MD 21076 Tel (410) 761-4000 www.polyplanar.com

- 7 -

Poly-Planar

Bass 0

Poly-Planar

Treb 0

Poly-Planar

Space 0

Poly-Planar

Vol 15

Poly-Planar

LoudON

Poly-Planar

LimON

Poly-Planar

EQ ON 2

Rotate VOLUME control to set the AUDIO parameters

Connecting the MZ-100 to an RD-44 control panel:

The MZ-100 can be controlled by the RD-44 control panel. Using an extension cable (not shown) the panel can be up to 60 feet away from the amplifier. Plug the RD-44 or its extension cable into the CONTROL PANEL plug on the MZ-100. Be sure to tighten the waterproof connectors.

Controls and Screens when Connected to an RD-44 control panel Screen Button Description

Power On start-up screen Volume is displayed 0 min 31 max Push 1 time to adjust Bass ( -9 min to + 9 max, 0 = flat ) Push 2 times to adjust Treble ( -9 min to + 9 max, 0 = flat ) Push 3 times to adjust Stereo Spatial Enhancement 0 = normal, 1 = wide, 2 = widest Push 4 times to set Loudness ON/OFF Enhances bass at low volumes Push 5 times to set Limiter ON/OFF ON prevents distortion at high volume Push 6 times to set Equalizer ON/OFF ON enables the equalizer selected by the switches shown on page 5.

IMPORTANT NOTE: The BLUE remote wire should

be tied to 12V (Red wire).

PO Box 409 Hanover, MD 21076 Tel (410) 761-4000 www.polyplanar.com

- 8 -

87.5 Stereo

FM1 P1 Vol 15

Local Input

Vol 15

Connecting the MZ-100 to a multi-zone audio system:

The MZ-100 is designed to be used in a multi-zone audio system. When combined with the MRD-70 CD/MP3 radio, RD-44 control panel and the RT-20 router, up to 4 independent zones can share sources and have communication through the RD-44s intercom.

Additional Controls and Screens when Connected to a Poly-Planar audio network. Screen Button Description

Chooses between the local RCA jack input on the amp or

a network source such as Poly-Planar CD/MP3 players, XM sources etc.

IMPORTANT NOTE: The BLUE remote wire should

be tied to 12V (Red wire).

PO Box 409 Hanover, MD 21076 Tel (410) 761-4000 www.polyplanar.com

- 9 -

Example of a 4 zone audio system.

PO Box 409 Hanover, MD 21076 Tel (410) 761-4000 www.polyplanar.com

- 10 -

Specifications:

Speaker Impedance 2 8 ohm Output Power (2 ohm load) 25 W RMS per channel (4 ohm load) 15 W RMS per channel Frequency Response . 20 Hz 20 kHz Operating Voltage .. 13.8V (10V 16V) DC Idle Current (no signal) 10 mA Maximum current draw (full power) .. 7 A Remote wire current 4 mA Dimensions (approx. w/h/d) .. 105mm X 40mm X 180mm 4.15 X 1.5 X 4.75 inches Weight .. 15 oz (.425 Kg)

Volume Control mounting template Note: Horizontal center of part is 5/16 inch (8mm) to the left of the mounting hole center.

2-1/16 in (52mm)

1-7/16 in (36mm) Drill = 7/8 in (22mm)

2-1/16 in (52mm)

5/16 in (8 mm)

Center line of part

PO Box 409 Hanover, MD 21076 Tel (410) 761-4000 www.polyplanar.com

- 11 -

Troubleshooting:

No Audio, Green LED Off 1. Make sure the Blue remote wired is switched to 12 volts. 2. Make sure the inline fuse is not blown. (Red wire) 3. Check that power wires are getting 12 volts from battery.

No Audio, Green LED On

1. Check that speaker outputs are not shorted to ground. 2. Make sure speakers are connected

Distorted Audio / Audio Cycles on & Off

1. Make sure speaker wires are not shorted together. 2. Power voltage too low or too high. 3. Input signal level too high. Turn down. 4. Power wire gauge too small. Use at least 14AWG wire.

Low Bass Output

Speakers are wired out of phase. Check polarity of wires to the speakers.

Amplifier Keeps Blowing Fuse

1. Battery + and reversed at power leads. 2. Incorrect or shorted wiring. 3. Too many speakers or shorted speaker voice coil.

Whining Noise from Speakers

1. Bad ground connection. Confirm that the black wire returns to battery ground with at least a 14AWG wire.

2. Do not share grounds or power connections with other power electronic equipment such as motors, pumps, and VHF radios.

3. Be careful to route all amplifier wires away from other high current equipment wires.

4. Add a noise filter or ground-loop isolator if all else fails. WARRANTY Poly-Planar marine audio systems are warranted to be free of defects in materials and workmanship for a period of two years. Warranty is subject to proper installation and operation within published specifications. Poly-Planar will repair or replace, at its discretion, any unit returned prepaid to its factory and determined to be defective. Poly- Planar Inc. is not liable for consequential damages.

12

107mm 4.21 in

156mm 6.14 in

78.5mm 3.1 in

78.5mm 3.1 in

168.5mm 6.63 in

Dr

Manualsnet FAQs

If you want to find out how the MZ-100 Poly-Planar works, you can view and download the Poly-Planar MZ-100 Amplifier Owner's Manual on the Manualsnet website.

Yes, we have the Owner's Manual for Poly-Planar MZ-100 as well as other Poly-Planar manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Owner's Manual should include all the details that are needed to use a Poly-Planar MZ-100. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Poly-Planar MZ-100 Amplifier Owner's Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Poly-Planar MZ-100 Amplifier Owner's Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Poly-Planar MZ-100 Amplifier Owner's Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Poly-Planar MZ-100 Amplifier Owner's Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Poly-Planar MZ-100 Amplifier Owner's Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.