C1534M (1/06)

I N S T A L L A T I O N / O P E R A T I O N

VMX200 Software

Contents Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

VMX210 Workstation Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

System Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Add Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

The Device Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Add A Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Draw the Wire Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Edit the Device Configuration Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Save and Cancel Changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Close the Device Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Backup the Device Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Configure Users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Add a User . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Delete A User . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Edit a User . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Copy a User . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 User Environment Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Configure Site Maps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 The Site Map Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Additional Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Configure Presets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Configure Sequences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Configure Macros . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Configure Scheduled Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Configure Camera Auxiliary Points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Configure Input/Output Points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Configure FTP Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Configure the Capture Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Configure the Video Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

Start VMX210 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Log In as a New User . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Navigate Between Site Maps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

Operating the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Select a Camera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Camera Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Video Window Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 View An External Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Operate a Preset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Operate Sequences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Operate Macros . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Alarm Point Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Operate a VCR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Image Capture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Operate Auxiliaries and Output Points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Advanced Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

2 C1534M (1/06)

Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 The VMX200 Site Map Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

Site Map Menu Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Site Map Zoom Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Site Map Status Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

The VMX210 Device Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Device Configuration Window Menu Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Device Configuration Window Tool Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

Reference Information for Adding Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Add A Camera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Add a Switcher . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Add an External Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Add a VCR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Add a Digital Input/output Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

Software Installation and Registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 VMX210 Software Reinstall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Software Registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Feature Upgrade Registration - For Future Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 CCTV Device Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Emergency Backup and Restore Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

C1534M (1/06) 3

List of Illustrations 1 Log-In Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2 Sample VMX210 Monitor Displays on a Single-Monitor System (left) and a Dual-Monitor System (right) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 3 VMX200 Device Configuration Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 4 Sample Add Device Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 5 Sample Device Details Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 6 Looping and Daisy-Chain Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 7 Mirror Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 8 Device Configuration Diagram Icon Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 9 Device Inventory Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

10 Find Device Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 11 Save Configuration Message Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 12 Users Dialog Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 13 User Properties Dialog Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 14 User Options Dialog Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 15 Startup Options Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 16 Alarm Options Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 17 Site Map Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 18 Maps Dialog Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 19 Open Site Map Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 20 Default Icon Colors Device Drop-down Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 21 Color Selection Palette . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 22 Editing Tool Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 23 Place Camera Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 24 Camera Icon on Site Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 25 Zoom Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 26 Resize Buttons on Editing Tool Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 27 Link Action Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 28 Sample Map Site Link Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 29 Sample Device Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 30 Preset Save/Edit Dialog Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 31 Sequences Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 32 Blank Sequence Editor Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 33 Sequence Event Details Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 34 Sequence Editor Window Edit Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 35 Macros Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 36 Macro Editor Dialog Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 37 Snapshot Macro Name Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 38 Scheduled Events Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 39 Edit Schedule Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 40 Which Days Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 41 Sunrise/Sunset Setup Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 42 Auxiliaries Dialog Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 43 Edit Point Properties Dialog Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 44 Sample Input/Output Points Dialog Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 45 CM9760-ALM (left) and CM9760-REL (right) Point Properties Dialog Boxes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 46 FTP Sites Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 47 Proxy Details Dialog Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 48 FTP Host Details Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 49 Image Capture Configuration Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 50 Log-In Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 51 Log-In Command on the File Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 52 Sample Map Site Link Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 53 Back Icon. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 54 Automation Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 55 Monitor Icon on Site Map Tool Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 56 External Monitor Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 57 Select Sequence Dialog Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 58 Macros Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 59 Alarm Viewer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

4 C1534M (1/06)

60 Capture Viewer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 61 VCR Icon on Site Map Tool Bar. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 62 VCRs Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 63 VCR Control Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 64 VCR Advanced Properties Dialog Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 65 Right-Click Pop-up Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 66 Capture Viewer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 67 Capture Viewer Folder List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 68 Filter Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 69 Filter By Date and Time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 70 Select a Sequence of Images . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 71 Maintenance Macro Set to Delete Captures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 72 Frame Capture Viewer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 73 Digital Output Control Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 74 Sample Camera Advanced Properties Dialog Boxes: General Tab (left) and Advanced Tab (right). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 75 External Device Advanced Properties. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 76 Advanced Properties Menu Option for CM6800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 77 Site Map Menu Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 78 Site Map Zoom Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 79 Site Map Status Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 80 Device Configuration Window Menu Bar. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 81 Device Configuration Window Tool Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 82 Backup Databases Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

C1534M (1/06) 5

6 C1534M (1/06)

List of Tables A User Permissions Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 B Sequence Editor Dialog Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 C Macro Editor Dialog Box Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 D Scheduled Events Schedule Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 E Keyboard Camera Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 F Capture Viewer Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 G Output Control Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 H Site Map Menu Bar Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 I Device Configuration Window Menu Bar Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 J Device Configuration Window Tool Bar Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

Description Pelcos Video Management System (VMX210) is an advanced, PC-based CCTV control system that offers the ability to integrate a variety of video surveillance equipment into a single, easy-to-use system. The VMX210 provides video and surveillance applications with a high level of functionality and user-friendly operation.

The VMX210 workstation is designed in the following configurations:

Dual-monitor, single video system with a Video-for-Windows VGA card

Dual-monitor system with quad video display

VMX210s strengths lie in its ability to control virtually any number and combination of devices with point and click simplicity. Both local and remote CCTV cameras, monitors, switchers, VCRs, and alarm input devices are easily added to the system and controlled with seamless integration.

VMX210 WORKSTATION SPECIFICATIONS Intel Pentium III processor, 800 MHz or faster

128 MB of memory or greater

Matrox Millennium video capture/display card

AGP slot to accept video capture/display card

100BaseT Ethernet port

40 GB hard drive

CD-RW drive

3.5-inch disk drive

Standard PC keyboard

Microsoft Windows 2000

PS/2 Microsoft IntelliMouse

C1534M (1/06) 7

Getting Started To use the VMX210, you must complete the following steps:

Connect the hardware; refer to the VMX210 Video Management System Installation/Operation Manual.

Configure your system; instructions are provided in the following pages.

The VMX210 workstation is shipped with the VMX200 software factory-installed. Refer to the Software Installation and Registration section in the Appendix for instructions on reinstalling the software.

1. Click the Windows Start button.

2. Choose Programs > VMX200 > VMX200. If you installed the program in a folder other than VMX200, choose that folder from the Start > Programs menu.

3. The VMX200 splash screen appears. In about five seconds the Log-in dialog box appears. If a message box appears, prompting you to type in a Base License, refer to the Software Installation and Registration section in the Appendix for instructions.

Figure 1. Log-In Dialog Box

4. Enter the administrator user name and password (both are case sensitive):

User Name: administrator Password: 2899100

The administrators user name and preferences cannot be changed. Pelco recommends that the administrator change the administrator password to maintain security. To protect the administrators ability to manage other user accounts, only the following settings can be changed for the administrators user name:

Password

Priority level

Start-up macro

To modify user settings, refer to Configure Users in the System Configuration section.

5. Click OK. The VMX200 video window(s) and the site map window appear on the system monitor(s).

Figure 2. Sample VMX210 Monitor Displays on a Single-Monitor System (left) and a Dual-Monitor System (right)

8 C1534M (1/06)

System Configuration Complete the following tasks to configure your system:

Add devices: Use the Device Configuration window to add and track CCTV equipment connected to the system. You can add any of the fol- lowing devices: Cameras Switchers and Genex multiplexers External Monitors

VMX210 can support multiple external monitors connected to any of the output ports on an external switcher or connected to an avail- able output port on the VMX210 workstation.

VCRs Input/Output Devices - alarm or relay interface units

VMX210 uses digital input/output devices for handling inputs from alarms or sending on/off signals to external relay devices.

Configure users: Enter user names, passwords, and preferences.

Configure site maps: Import and edit site maps of the facility.

ADD DEVICES To add new devices to the system, complete the following tasks:

Add each device in the Device Configuration window. Instructions are provided in the following pages.

Draw the device wiring connections in the Device Configuration diagram. Refer to the Draw the Wire Connections section for instructions.

Place the icons listed below on system site maps, as necessary. Refer to the Configure Site Maps section for instructions. Cameras Alarm points Macros External monitors VCRs

THE DEVICE CONFIGURATION WINDOW

The Device Configuration window is a graphical representation of the systems design, which allows the administrator to control how data from video sources is routed through and to various components of the system. Select Configure > Devices from the site map menu bar. The Device Configuration window appears.

Figure 3. VMX200 Device Configuration Window

C1534M (1/06) 9

The VMX200 Device Configuration window contains the following components:

The menu bar

The tool bar

The device configuration diagram

The device configuration diagram includes the following components:

Port nodes on each device; these are represented by color-coded tabs Wires between each device; these are also color-coded Switch paths Device icon labels

Port nodes and device wires are designated by color. The Node Legend provides an on-screen lengend to the node and wire color coding, and is useful for keeping track of connections when diagramming larger systems. Click View > Node Legend to hide the Node Legend box (or to display the box when it is hidden from view).

Refer to the Appendix for a description of the Device Configuration window menu bar and tool bar.

There are three ways to perform operations on the configuration window:

Select an option from the menu bar.

Click the right mouse button on the diagram, and then select an option from the pop-up menu.

Click a tool bar icon.

ADD A DEVICE

1. Select Configure > Devices. The Device Configuration window appears.

2. Click the appropriate add device icon (for example, the camera icon) on the tool bar. The applicable add device dialog box appears.

Alternate Step 2 From the menu bar select Edit > Add, and then select the appropriate device (for example, Edit > Add > Camera).

OR

Right-click the device configuration diagram, select Add from the right mouse pop-up menu, and then select the appropriate device (for example Add > Camera).

OR

To add a device without adding an icon to the diagram, use the Device Inventory. Refer to the Device Inventory section.

Figure 4. Sample Add Device Dialog Box

3. Complete the fields in each dialog box, and then click Next until a dialog box with the message Device configuration complete appears.

The dialog boxes contain instructions for completing the entry fields. However, if you need assistance, field definitions are provided in the Appendix; refer to the Reference Information for Adding Devices section.

NOTE: To install a new device driver, click Have Disk on the Make and Model dialog box; refer to the CCTV Device Drivers section in the Appendix.

10 C1534M (1/06)

4. Click Finish.

5. The device icon appears in the center of the configuration diagram. Drag the icon to an appropriate position in the window, and draw connections to other pieces of equipment to reflect the physical system wiring.

Refer to the Draw the Wire Connections section for instructions on drawing the device connections.

NOTE: The Device Configuration window does not include a function for saving your work. To save changes you must exit the Device Configuration window and click Yes in the Save Configuration dialog box. Refer to the Close the Device Configuration Window section. Also refer to the Emergency Backup and Restore Procedures in the Appendix for information on safeguarding your work.

Additional Steps for Adding an External Monitor

VMX210 can support an unlimited number of external display monitors. These monitors must be physically connected to available outputs of switchers connected to the system. Once they are installed and properly connected on the system configuration diagram, they must also be added to the site map. Refer to Configure External Device Windows in the Configure Site Maps section for instructions.

Additional Steps for Adding an Input/Output Device

Relay Interface Units To be able to access and use a relay interface unit you must do either or both of the following:

Configure a macro event to set the output point to true or false; refer to Configure Macros in the Additional Configuration section.

Call the relay unit manually from the Output Control dialog box; refer to Digital Output Point Controls in the Operation section.

Alarm Interface Units Animated icons for specific alarm points can be placed on appropriate site maps. These icons indicate when activity has occurred at the point, and provide easy access to the Alarm Viewer. Refer to Add a Map Icon in the Configure Site Maps section.

In addition, you can configure an alarm input point to launch a macro. Refer to Configure Input/Output Points in the Additional Configuration section for instructions on launching a macro based on an input alarm or reset.

Edit Device Properties You can change device settings by completing the following steps from the Device Configuration window:

1. Double-click the appropriate device icon. The appropriate device details dialog box appears.

Alternate Step 1 Right-click the appropriate device icon, and then select Properties from the pop-up menu.

OR

Click the device, and then select Edit > Properties from the menu bar.

Figure 5. Sample Device Details Dialog Box

2. Edit the device properties as necessary. If the device has more than one page of properties, click the appropriate tab. For example, to edit a VCRs address, click the Make/Model tab.

3. Click OK.

C1534M (1/06) 11

DRAW THE WIRE CONNECTIONS

1. Move the mouse to the appropriate tab on the first device. The mouse pointer changes to a crosshair icon.

2. Click the tab. This anchors the wire line to the device.

3. Move the mouse to the appropriate tab on the connecting device. The mouse pointer changes to a crosshair icon again.

4. Click the tab to complete the connection.

5. Repeat for each device. When every device has been added, save the diagram changes by exiting the Device Configuration window. Refer to the Close the Device Configuration Window section.

Drawing Tips

The mouse pointer remains a crosshair icon when you move to a compatible connection tab. If you point to an incompatible connection tab the mouse pointer returns to an arrow and you cannot click the incompatible connection tab. To change the direction of a line from vertical or horizontal or from horizontal to vertical, click the mouse at each change of direction.

NOTE: Press the ESC key to delete a wire before completing the connection.

Drawing Camera Connections Draw a connection between each camera and an external switcher or one of the VMX210 workstations internal switcher card terminals. If the camera is controlled through a serial connection, draw a wire from the cameras control tab to one of the serial control (COM port) tabs on the PC icon.

Drawing Switcher Connections External switchers may be stacked to multiply the number of cameras that can be added to the system. To do this, connect the output terminals from one switcher into the input terminals of another.

Drawing External Monitor Connections Draw a connection between each external monitor and an external switcher or one of the VMX210 workstations internal switcher card terminals (VMX210-SYS-Q only).

Drawing VCR Connections Draw connections from the VCR icons video input tab and video output tab to the appropriate switcher tabs. Note that a proper routing path from the video source must be available.

Drawing Digital Input Device Connections Draw a connection from the digital input device icon to one of the serial control (COM port) tabs on the PC icon.

Looping Inputs Video output nodes support the creation of multiple connections to video inputs on other devices. Click the mouse on the video output node and draw the connections to other input nodes one at a time. This feature can be used to simulate looping inputs.

12 C1534M (1/06)

Daisy-Chaining Serial Communications VMX210 supports daisy-chain serial configuration of addressable devices by permitting two connections to each of the communication ports on cameras, switchers, multiplexers, recorders, and other serial equipment. Device addressing must be carefully observed when designing chained devices.

Figure 6. Looping and Daisy-Chain Connections

EDIT THE DEVICE CONFIGURATION DIAGRAM

Select Elements on the Diagram Do one of the following:

Click the desired icon.

Click and drag a box around multiple icons.

Select multiple icons by holding the Ctrl key while clicking each desired icon.

Move Icons 1. Click the icon.

2. Drag the icon to a new location on the diagram. The wire line remains connected to the icon but may be poorly positioned after moving a device icon. To adjust the wire line:

a. Click the wire line. The selected wire is highlighted blue.

b. Click any of the lines anchor points, and then drag to a new location.

3. Optional: Use the keyboard arrow keys (left, right, up, down) to move the icon one grid space.

Copy Icons 1. Click the icon.

2. Select Edit > Copy from the Menu Bar.

3. Select Edit > Paste to place a duplicate icon.

The device properties are copied from the original device. The new device is named Copy of .

Alternate Step 3 Select Edit > Paste Many to place more than one duplicate icon. Specify the number of duplicate icons.

4. Drag the new icon(s) to an appropriate location.

5. Draw wire connections to other system equipment as described in the Draw the Wire Connections section.

6. If necessary, change the name and device properties, as described in the Edit the Device Configuration Diagram section.

C1534M (1/06) 13

Change Icon Orientation

1. Click the device icon, and then select Edit > Mirror from the menu bar.

Alternate Step 1 Right-click the device icon, and then select Mirror.

Figure 7. Mirror Option

2. From the Mirror submenu, select the desired orientation:

Horizontally: This option reverses the icon left-to-right. Vertically: This option flips the icon top-to-bottom.

Delete a Device Deleting a device from the device configuration diagram also removes the device wire lines and the device settings specified when the device was added to the system.

1. Click the device icon.

2. Press the Delete key. The device is deleted from the diagram and the Device Inventory.

This action cannot be reversed. If you delete a device icon by mistake, you can either

revert to the last saved version of the configuration drawing,

OR

close the current configuration drawing without saving any changes, and then open it again.

NOTE: However, that you will lose any other changes made during the current editing session.

Adjust Wire Lines 1. Click the desired wire line. The line appears bright blue and displays anchor points at each change in direction of the line.

2. Click an anchor point, and then drag it to the desired location to change the wire line.

Delete Wire Lines 1. Click the desired wire line. The line appears bright blue.

2. Press the Delete key.

3. Redraw the wire as desired.

14 C1534M (1/06)

Device Icon Labels Icon labels are provided for each device installed in the system.

Figure 8. Device Configuration Diagram Icon Label

Move a Label 1. Click the label.

2. Drag it to a new position.

Change Label Orientation 1. Right-click a label to turn it 90 degrees counterclockwise.

2. Right-click again until the label is at the desired orientation.

Edit a Label A device label reflects the name selected when the device is added to the system. To change the device label, change the device name in

the device Properties, as described in the Changing Device Settings section.

View/Hide Labels Select View > Labels from the menu bar; in the submenu, click the desired device type to view or hide all labels for that device type. The check mark beside the item indicates that the label is visible.

Device Inventory To define devices without adding them to the current configuration diagram, use the Device Inventory. The Device Inventory provides a means of saving the specific installation details of any device within the system without adding it to the device configuration diagram.

Opening the Device Inventory 1. Select Edit > Device Inventory > Open from the Device Configuration window menu bar.

Alternate Step 1 Right-click the device configuration diagram, and then select Device Inventory > Open.

2. The Device Inventory window appears.

Figure 9. Device Inventory Window

The Device Inventory includes all devices shown on the device configuration diagram, plus any devices that have been added directly to the inventory without including them on the diagram. The column on the right side of the Device Inventory window, labeled In Use, indicates whether the device is included in the device configuration diagram (Yes or No).

C1534M (1/06) 15

Adding Devices to the Device Inventory 1. In the Device Inventory window, click New. The Select Device dialog box appears.

2. Select the device type from the drop-down box. Note that you cannot add input/output devices to the Device Inventory.

3. Click OK. The applicable add device dialog box appears.

4. Add the device, as described in the Adding Devices to the Device Inventory section.

5. When you have finished, the device appears on the list of devices in the Device Inventory window.

NOTE: Deleting a device in the device inventory also deletes the device from the device configuration diagram; refer to Delete a Device in the preceding section.

Move Devices to the Device Inventory When a device is moved to the Device Inventory from the device configuration diagram, all connections to other devices are removed and must be redrawn if the device is moved back to the diagram.

You can move a device to the Device Inventory in either of the following ways:

1. Click the device icon.

2. Select Edit > Device Inventory > Move Selected To from the Device Configuration window menu bar.

3. The device icon disappears from the device configuration diagram.

OR

1. Open the Device Inventory window.

2. Drag the device icon from the device configuration diagram to the Device Inventory window. The device appears on the list of devices in the Device Inventory window and the In Use designation changes to No.

Adding a Device to the Device Configuration Diagram from the Device Inventory 1. Click the device in the list of devices in the Device Inventory window.

2. Drag the device to the device configuration diagram. The icon appears on the diagram and the In Use designation in the Device Inventory window changes to Yes.

3. Draw the wire connections, as described in the Draw the Wire Connections section.

Additional Device Inventory Features The following additional features are available on the Device Inventory window:

Print: This option opens a standard Windows print dialog box, allowing you to print the contents of the inventory list.

Filter: This option opens the Device Filter dialog box, allowing you to filter the list of devices visible in the Device Inventory window accord- ing to the device type(s) selected.

Find Device: This option opens the Inventory Find Device dialog box, allowing you to find specific devices in the inventory based on both a device-type filter, and optional name, location, and description field keywords.

16 C1534M (1/06)

Find Device Utility The Find Device utility assists with the management of large and complicated system diagrams. This feature locates a specific device and centers the configuration diagram on that device.

1. Select Edit > Find Device from the Device Configuration window menu bar. The Find Device dialog box appears.

Alternate Step 1 Right-click the configuration diagram, and then select Find Device from the pop-up menu.

Figure 10. Find Device Dialog Box

2. Select a device type from the drop-down box.

3. A corresponding list of installed components appears. Click the name of the device you want to find.

4. Click Locate. The configuration diagram repositions to center on the specified device.

Print the Device Configuration Diagram A printed copy of the configuration diagram can be helpful during installation and for system record keeping.

1. From the Device Configuration window, select File > Print. A standard Windows print dialog box appears.

2. Select the appropriate print options.

3. Click OK. The configuration diagram prints on the specified printer.

NOTE: To use the print function, you must have a printer connected to the VMX210 workstation parallel port. Refer to the Windows 2000 documentation for printer installation instructions.

SAVE AND CANCEL CHANGES

Save Changes When you exit the Device Configuration window, the Save Configuration message box prompts you to save changes. Refer to the Close the Device Configuration Window section.

As the system saves your changes, it will report any conflicts or errors in the wiring diagram, and errors must be corrected before the changes can be saved. Due to inherent design flexibility, many errors are outside the scope of the softwares diagnostic tests. Careful planning and documentation is recommended in order to avoid problems and speed system integration time.

Cancel Changes\Revert To cancel the changes you have made in the Device Configuration window, you can reload the previously saved configuration diagram.

1. Select File > Revert from the menu bar.

Alternate Step 1 Click the Revert icon on the tool bar.

2. Click Yes in the Revert to last saved configuration? message box. The previously saved configuration diagram appears.

C1534M (1/06) 17

CLOSE THE DEVICE CONFIGURATION WINDOW

1. Select File > Close to exit the Device Configuration window.

If you have made any changes to the device configuration, the Save Configuration message box appears.

Figure 11. Save Configuration Message Box

Click Yes to save the changes and rebuild routing information, and then exit to the site map window. Click No to cancel the changes and exit to the site map window. Click Cancel to remain in the Device Configuration window.

If you have not made any changes to the device configuration, the Save Configuration message box does not appear.

2. The Device Configuration window closes and the site map window appears.

BACKUP THE DEVICE CONFIGURATION

Pelco strongly recommends that you make a backup copy of the device configuration, in the unlikely event of a serious system failure. Refer to the Emergency Backup and Restore Procedures section in the Appendix for information.

CONFIGURE USERS NOTE: The administrator user name and preferences cannot be changed.

Each user must log in to the system with a user name and password. The system administrator assigns a user name by creating a user profile, and then configures it with the appropriate level of access to system configuration tools.

ADD A USER

1. Select Configure > Users from the site map menu bar. The Users dialog box appears.

Figure 12. Users Dialog Box

18 C1534M (1/06)

2. Click New. The User Properties dialog box appears

.

Figure 13. User Properties Dialog Box

3. Complete the following fields as appropriate for the specific user:

Username: The username is case sensitive and can be a maximum of 64 characters.

Full Name: Enter the users proper name.

Password: The password is case sensitive and can be a maximum of 64 characters. The user can change the password at any time.

Confirm Password: Re-type the password entered in the password field. If the two entries differ, an error message appears.

User Priority: This option is not used at this time.

Permissions: Select the check boxes beside the user permissions appropriate for the new user. For a complete description of the available permissions, refer to the User Permissions Table.

4. Click OK.

User Permissions Each User ID can be configured with specific user permissions, allowing the user access to specific functionality in the software.

Table A. User Permissions Table

Can Add/Remove Users The user can create, edit, and delete user accounts. Pelco recommends that this capability be restricted to system administrators only.

Can Alter Device Configurations/ Manage Databases

The user can add, edit, and delete equipment and wiring on the device configuration diagram. The user can also access advanced switcher properties. Most users should not have access to this capability.

Can Configure FTP Sites The user can add and edit proxy and FTP server settings.

Can Define Automation Functions The user can access the automation functions, which include the sequence, macro, and schedule editors, digital output control (if a digital device is installed), and the camera following feature.

Can Configure/Edit Maps The user can edit the site map images, including importing new images.

Can Configure Digital I/O Devices The user can edit alarm input points and relay output points.

Can Configure Auxiliary Points The user can edit camera auxiliary point names and logic settings.

Can Configure Overlay/Capture Cards The user can select the capture file format and set the compression level for JPG captures.

Can Configure VCR/Ext. Monitor Windows The user can alter the configuration of VCRs and monitors within their drag and drop windows.

C1534M (1/06) 19

DELETE A USER

1. In the Users dialog box select the desired user name from the list of users.

2. Click Delete.

3. Click OK.

EDIT A USER

1. In the Users dialog box select the desired user name from the list of users.

2. Click Edit. The Edit User Properties dialog box appears.

3. Change the users properties as necessary.

4. Click OK.

COPY A USER

The copy utility allows an administrator to create standard user accounts quickly.

1. In the Users dialog box select the user name of a typical user from the list of users.

2. Click Copy. The Edit User Properties dialog box appears.

3. Change the user name (the default is Copy of ) and other properties as necessary.

4. Click OK.

USER ENVIRONMENT OPTIONS

The following options can be configured either by the system administrator or by the user. Each option setting is saved with the user profile and remains active each time the user logs onto the system.

Change General Options 1. Select Edit > Options from the site map menu bar. The Options dialog box appears.

Figure 14. User Options Dialog Box

2. Select the following options as appropriate:

Hotlinks: Select Always Visible to make the hot link regions on site maps visible. Select Only Visible When Editing Map to make the hot link regions on site maps visible only when the map is being edited.

Video Minimize: Select this option to make all VMX200 video windows minimize on the Windows desktop whenever the Site Map window is minimized.

3. Click OK.

20 C1534M (1/06)

Change Start-Up Options 1. Select Edit > Options from the site map menu bar. The Options dialog box appears.

2. Click on the Startup tab. The start-up options appear.

Figure 15. Startup Options Tab

3. Select the following options as appropriate:

Startup Map: Select the map to be loaded when the user logs in. If you have not yet imported site map images, the only option available is the Default Map. Refer to Import a Site Map Image in the Configure Site Maps section.

Startup Macro: Select the desired start-up macro to be run when the user logs in, immediately after the AutoRun macro. This setting is specific for each user and can be executed or disabled on the login dialog box.

The AutoRun macro initializes the VMX200 video windows and will call up the system settings that were valid when the software was last exited.

The users start-up macro might be a specific set of cameras displayed on specific monitors, or it might be designed to run a quick tour of facilities.

NOTE: You must create system macros before you can select a start-up macro for the user. Refer to Configure Macros in the Additional Configuration section for more information on macros.

4. Click OK.

Change Alarm Options 1. Select Edit > Options from the site map menu bar. The Options dialog box appears.

2. Click on the Alarms tab. The Alarms option appears.

Figure 16. Alarm Options Tab

3. 3. Click the Alarm Viewer check box to make the alarm viewer pop-up automatically each time a new alarm point is activated.

OR

Leave the Alarm Viewer check box unchecked if the user will rely on a periodic manual scan of the alarm viewer as a check for new alarm events.

4. Click OK.

C1534M (1/06) 21

CONFIGURE SITE MAPS Site maps are at the heart of the VMX200 user environment. Maps provide the system operator with a graphical representation of the camera installations, eliminating the need to remember camera and monitor selection codes. VMX200 provides tools to place, move, and delete installed equipment, and to create links to other site maps.

THE SITE MAP WINDOW

The site map window contains the following elements:

Menu bar

Tool bar

Site map image

Status bar

Refer to the Appendix for a detailed description of the menu bar, tool bar, and status bar.

Figure 17. Site Map Window

Work with Site Map Images Graphics created in software packages such as Adobe Photoshop or AutoCAD can be imported into the VMX200, and then used as a graphical representation of system camera positions.

Site Map Image Formats Before using such site map images, they must first be imported into VMX200 in one of the following image formats:

Bitmap (.bmp)

JPEG (.jpg)

Windows meta file (.wmf)

Extended meta file (.emf).

Pelco recommends the following image format parameters:

Use meta file formats (.wmf and .emf) if possible. These are vector graphic formats and are recommended because they provide the advan- tage of being scalable without losing detail.

Size your maps to 1016 x 673 pixels and 16-bit color when you are creating them. This will allow you to optimize your workspace and pre- vent having to resize the map each time it is loaded.

With bitmap formats (.bmp and .jpg) use a resolution of 72 dpi (dots per inch). This resolution provides an optimal file size for display and memory.

22 C1534M (1/06)

Open the Site Maps Dialog Box

Select Configure > Maps. The Maps dialog box appears, displaying a list of all maps imported into VMX200 and a thumbnail preview of the selected map. Or, right-click the map image, and then select Maps from the pop-up menu.

Figure 18. Maps Dialog Box

The Maps dialog box displays the following information:

The resolution (in pixels) and size (in inches) of the site map diagram on the monitor (Viewport Size)

The resolution and size of the selected map

The filename of the selected map

Import a Site Map Image Save or copy images to the Site Maps directory within the VMX200 directory on the workstation hard drive. If necessary, you can save map images to another folder, but the system refers to the Site Maps directory first when installing a new map. Use Windows Explorer to assist you in finding the appropriate directory.

1. In the Maps dialog box, click New. The Open Site Map dialog box appears.

Figure 19. Open Site Map Dialog Box

2. If necessary, navigate though system folders until the list of map image files appears. By default, VMX200 site map images are located in the Program Files\CamControlSvr\sitemaps folder.

C1534M (1/06) 23

3. Click the desired map image file, and then click Open.

The map image appears in the list of VMX200 maps and can be loaded by

clicking Open from the Maps dialog box,

OR

creating a link from another map; refer to Create a Link to Another Site Map Image.

4. Click Cancel to close the Maps dialog box.

Delete a Map Image 1. In the Maps dialog box, click the desired map file.

2. Click Delete. The Confirm Map Delete dialog box appears.

3. Click OK.

NOTE: This delete operation cannot be reversed. However, the file is only removed from the VMX210 system, not from the computers hard drive. If you delete a file accidentally, you must import it into VMX200 again. Refer to Import a Site Map Image.

Rename a Map Image This action changes the name assigned to the map within VMX200, but does not change the image file name.

1. In the Maps dialog box, click the desired map file.

2. Click Rename. The Map Rename dialog box appears.

3. Type the new name, and then click OK.

Create a Default Map Image Each user can specify the specific start-up map to be displayed when the user logs into the system. Refer to the User Environment Options section for more information.

Open a Map Image 1. In the Maps dialog box, click the desired map file.

2. 2. Click Open. The selected map image appears on the main map window.

3. 3. Click Close.

Change Map Icon Default Colors VMX200 provides an option to modify the default color for each device-type icon used in a site map.

1. In the Maps dialog box, click the desired map file.

2. In the Default Icon Colors section of the Maps dialog box, select the desired device-type icon from the device drop-down box.

Figure 20. Default Icon Colors Device Drop-down Box

24 C1534M (1/06)

3. Click Edit. The color selection palette appears, showing both the default color for the selected icon along with the new setting.

Figure 21. Color Selection Palette

4. Select a new color for the device icon.

5. Click OK. The new default color will be applied each time a new icon of that device-type is added to the selected map.

6. Repeat for each map that requires a change in default icon colors. To change the color of a specific icon while editing an individual map, refer to Change a Map Icon Color in the Edit Site Maps section.

Edit Site Maps Site Map images can be edited to include items such as camera, alarm, or macro icons, and links to associated maps. To enter the site map editing mode:

1. Select > Edit > Site Map.

Alternate Step 1 Right-click the map image, and then select Edit Map from the pop-up menu.

2. The editing tool bar appears.

Figure 22. Editing Tool Bar

To exit the edit mode, click the X in the top right corner of the editing tool bar.

Add a Map Icon 1. Click the camera, alarm, or macro button on the editing tool bar. The mouse pointer changes to the selected icon.

NOTE: To add a macro or an alarm to the map, you must have previously defined the macro or alarm within the VMX210 system. Refer to Configure Macros and Configure Input/Output Points in the Additional Configuration section for more information.

C1534M (1/06) 25

2. Click the map in the desired icon location. The appropriate Place Icon dialog box appears, displaying a list of the cameras, alarms, or macros available.

Figure 23. Place Camera Dialog Box

3. Click the desired camera, alarm, or macro from the list, and then click OK. The icon appears on the map.

Figure 24. Camera Icon on Site Map

Change a Map Icon Color 1. Right-click the camera, alarm, or macro icon that you wish to change, and then select Edit Icon Color from the pop-up menu.

2. The color selection palette appears. Click a color to replace the default color for the selected icon. To return to the default icon color, click the Default Color field.

3. Click OK.

Move a Map Icon 1. Click the pointer tool on the editing tool bar.

2. Click the desired icon.

3. Drag the icon to a new location.

Alternate Step 3 Use the keyboard arrow keys to move the icon to the new location.

Delete Map Icons 1. Click the pointer tool on the editing tool bar.

2. Right-click the desired icon, and then select Delete from the pop-up menu.

3. The selected icon is removed from the site map. Deleting an icon removes the icon from the site map, but it will not delete the device from the system. To remove a device from the system, refer to Delete a Device in the System Configuration section.

Zoom a Map Image Use the Zoom In, Zoom Out, Zoom 1 to 1, and Zoom to Page icons on the site map window to increase or decrease the size of the currently active map image. To use the Zoom In icon, click Zoom In, and then click the site map. Release the mouse button or drag a box around the section of the map that you want to enlarge.

Figure 25. Zoom Icons

26 C1534M (1/06)

Resize a Map Icon Use the + and - buttons on the editing tool bar to increase and decrease the size of the icons placed on the currently active map image. The size of the map icons remains constant relative to the map image when using the map zoom functions. It is recommended that icons be sized for the map at the zoom level used most often.

Figure 26. Resize Buttons on Editing Tool Bar

Create a Link to Another Site Map Image You can link related maps, allowing for cameras to be easily located and managed. Pelco recommends that you document a site maps hierarchy on paper prior to working in the VMX210 system in order to avoid creating incorrect, unnecessary, or confusing links. Since a defined area may be invisible to the user except for a change in the mouse cursor, you may want to add a link graphic to desired areas of the images before importing them into VMX200.

1. Click the hyperlink button on the editing tool bar.

2. Position the mouse crosshairs at a desired starting point on the site map image, and then click several points around the perimeter of the area you wish to define as a link. Continue clicking perimeter points until you have created the link area.

3. Once the link area is defined, right-click inside it. The Link Action dialog box appears.

Figure 27. Link Action Dialog Box

4. Click Load Map and then select the desired map file from the Maps drop-down box.

5. Click OK.

Once you close the editing tool bar, the lines around the link areas disappear. As you move the mouse over a linked area, the mouse pointer changes to a finger pointer to indicate a linked area. The name of the destination map for a link area appears in the bottom of the map window.

Figure 28. Sample Map Site Link Area

Delete Links to Other Site Map Images 1. Click one of the link areas lines. The blue boundary lines change to pink.

2. Press the Del key on the keyboard.

NOTE: This action cannot be reversed. If you delete a link by accident, you must redraw it.

Configure External Device Windows All installed external monitors, VCRs, and DVRs, are represented on the site map window by the appropriate icons on the site map tool bar. Refer to the Operation section for more information on using these icons.

C1534M (1/06) 27

Add a Device to the Drag and Drop Areas 1. Select Configure > External Monitors Window (or any other device type that appears on the Configure menu).

Alternate Step 1 Right-click the desired device on the tool bar, and then select Configure from the pop-up menu. The specified device window appears.

Figure 29. Sample Device Window

2. Click the add device icon in the device window tool bar. The cursor changes to represent the device-type.

3. Move to the desired area of the window and click to add the device icon. A select dialog box appears that displays all the installed devices that have yet to be placed in the window.

4. Select a device, and then click OK. More than one device can be selected by holding down the Shift or Ctrl keys.

NOTE: You can arrange devices in the window to represent their physical arrangement in your system console, racks, or monitor wall.

Edit the Drag and Drop Icons 1. From the device window, select Configure > Edit layout from the menu bar.

2. Click Edit to display the Edit submenu, which contains the following options:

Edit Submenu Option Sub-option Function Icon Alignment Centers Align the icons vertically.

Middles Align the icons horizontally.

Icon Spacing Increase horizontally Increase the horizontal space between icons. Make equal horizontally Space the icons at an equal distance horizontally. Decrease horizontally Decrease the horizontal space between icons. Make equal vertically Space the icons at an equal distance vertically. Increase vertically Increase the vertical space between icons. Decrease vertically Decrease the vertical space between icons. Snap to Grid Align all icons to a fixed grid.

NOTE: To use the Icon Alignment and Icon Spacing options, the Snap to Grid option must be turned off.

ADDITIONAL CONFIGURATION

CONFIGURE PRESETS

Many cameras have the capability to store frequently used camera positions as presets. These positions can be defined and named within the VMX210 system for use manually and as elements of more complex automation features.

Create a Preset 1. Drag and drop the desired camera into one of the VMX200 video windows to view its output.

2. Pan, tilt, and zoom the camera to the desired view, and then right-click the video image. The video control pop-up menu appears.

add device icon

28 C1534M (1/06)

3. Select Save > Edit Preset to view the list of presets available for that camera. If the Save/Edit Preset menu item is not available, then the camera does not have any preset capability.

Figure 30. Preset Save/Edit Dialog Box

4. Select one of the presets named Unassigned, and then click Save.

Alternate Step 4 Double-click one of the presets named Unassigned.

5. Type a preset name, and then click OK to return to the Preset Save/Edit dialog box.

Edit a Preset 1. Right-click the desired cameras video display, and then select Save/Edit Preset from the pop-up menu.

2. Click Rename.

3. Type the new preset name, and then click OK. Renaming a preset does not save the position.

Unassign a Preset Because a preset is a characteristic of the camera, it cannot be deleted. You can, however, unassign the preset setting by selecting the preset and clicking the Unassign button. You can also reassign a preset by selecting an existing preset instead of an unassigned one when saving and naming a new preset.

CONFIGURE SEQUENCES

Sequences combine preset camera moves, image captures, and time elements into a single script that can be triggered manually or included in macro automated events.

Open the Sequences Dialog Box 1. Select Automation > Sequences > Edit from the site map window menu bar.

Alternate Step 1 Right-click the site map window, and then select Sequences > Edit from the pop-up menu.

C1534M (1/06) 29

2. The Sequences dialog box appears, with a list of sequences. From this dialog box, you can create, delete, edit, and rename any sequences.

Figure 31. Sequences Dialog Box

Create a Sequence 1. From the Sequences dialog box click New.

2. Type a name in the Sequence name dialog box.

3. Click OK. The Sequence Editor window appears.

Figure 32. Blank Sequence Editor Window

4. Each line in the editor is a separate event to be executed sequentially. Drag and drop the appropriate camera for the first action from the site map to the Sequence Editor window. VMX200 creates a new line in the sequence and opens a series of Event Details dialog boxes.

Figure 33. Sequence Event Details Dialog Box

30 C1534M (1/06)

5. Complete the necessary fields in each dialog box, and then click Next. Refer to Table B for instructions on completing each dialog box.

Table B. Sequence Editor Dialog Boxes

6. For each event in the sequence, drag a camera to the sequence editor window and complete the dialog boxes. When finished, select File > Save, and then select File > Close.

Alternate Save And Close Steps a. Click the X in the top right corner to close the Sequence Editor window.

b. Click Yes in the Save Changes message box.

Edit a Sequence 1. From the Sequences dialog box, select a sequence from the list, and then click Edit. The Sequence Editor window appears.

Alternate Step 1 Double-click the desired sequence.

2. Select an event in the sequence, and then click Edit on the Sequence Editor Menu Bar or right-click a sequence event. The Edit menu appears.

Edit the event using any of the edit options listed below.

Figure 34. Sequence Editor Window Edit Menu

Change the Order of Sequence Events To change the order of an event within the sequence, select the desired event line, and then select Move Up or Move Down.

Camera Action Specify the required camera actions. Note that the camera must be viewed in order to capture an image.

Total Event Time Specify the total time allocated for the event before the system processes the next event. Allow enough time to include any Move to Preset and Capture options.

Wait for Capture Time If the image capture option was selected in the first dialog box, specify the amount of time the system is to wait before capturing an image.

This value should allow the camera time to finish a preset function prior to capturing an image. The pan and tilt speed of the selected camera must be considered in setting this value; a degrees-per-second value may be provided in the appropriate camera user manual.

Select Preset This dialog box appears if Move to Preset was selected in the first dialog box. Select the preset the camera will be sent to. If you are using a PelcoNet device, enter the amount of time to delay the preset switch (this allows time for the PelcoNet device to switch over the network).

FTP Setting If you select Capture in the first dialog box, you can send an image capture file to an Internet file server, using File Transfer Protocol (FTP). To use FTP, you must first configure FTP settings. Refer to the Configure FTP Settings section.

To send a file, complete the following steps:

a Click Yes, and then select the FTP server from the drop-down box.

b If you enter a name in the Upload Filename field, VMX200 assigns the specified filename to the capture file, and each capture overwrites previous captures with the same name on the FTP server. VMX200 adds an appropriate file-type extension.

If you leave the Upload Filename field blank, VMX200 assigns a sequential filename to the file, similar to the filenames assigned to alarm-based captures.

Finish Click Finish to complete the sequence event, or click Back to edit any of the previous steps.

C1534M (1/06) 31

Cut and Paste a Sequence Event To cut and paste an event line to a new position, select the event, and then select Copy or Cut. Click the event line that is to follow the copied event, and then select Paste Insert.

Delete a Sequence Event If you copy an event, you must delete the original event to avoid duplication. Click the original event, and then select Delete.

Edit Sequence Properties a. Select an event, and then click Properties. The Event Details dialog box appears.

OR Double-click the event.

b. Edit the properties as necessary.

3. When finished, save the changes and close the Sequence Editor window.

Rename a Sequence 1. From the Sequences dialog box, select a sequence from the list, and then click Rename.

2. Type a new name, and then click OK.

Delete a Sequence 1. From the Sequences dialog box, select a sequence from the list, and then click Delete.

2. Click OK to confirm the deletion. Note that the delete action cannot be reversed.

CONFIGURE MACROS

Macros provide a means of specifying a combination of system events, which can include the following devices or actions:

Camera switch

Sequence

Image capture (as an event in a sequence)

Monitors

Recording devices

Macros can be triggered either manually or in response to an alarm event.

For example, in response to a door alarm, the system can trigger a macro that executes the following commands:

Three cameras move to presets that focus on the area indicated by the door alarm.

The system displays these images on three specified monitors.

Start a sequence with image capture.

Direct a VCR to start recording one of the cameras.

Open the Macros Dialog Box 1. Select Automation > Macros from the site map window menu bar.

Alternate Step 1 Right-click the site map window, and then select Macros from the pop-up menu.

32 C1534M (1/06)

2. The Macros dialog box appears with a list of macros. From this dialog box, you can create, delete, edit, rename, and run any macro.

Figure 35. Macros Dialog Box

Create a Macro 1. From the Macros dialog box, click New.

2. Type a macro name in the Macro Name dialog box.

3. Click OK. The Macro Editor dialog box appears.

Figure 36. Macro Editor Dialog Box

Edit a Macro 1. From the Macros dialog box, select a macro, and then click Edit. The Macro Editor dialog box appears.

2. Use the Macro Editor tools to adjust existing commands or add new commands, as necessary. Refer to Table C for a description of each Macro Editor tool.

C1534M (1/06) 33

Table C. Macro Editor Dialog Box Icons

Rename a Macro 1. From the Macros dialog box, select the desired macro, and then click Rename.

2. Type the new name, and then click OK. All references to this macro will be updated to reflect the new name.

Run a Macro

Run a Macro Manually Run a macro manually in either of the following ways:

Place a macro icon onto the appropriate facility map image. Double-click the icon to execute the macro. Refer to Add a Map Icon in the Configure Site Maps section for more information on placing macro icons onto maps.

From the Macros dialog box, select the desired macro, and then select Run. This method is primarily used to test a macro for proper execu- tion after creating it.

Configure an Automated Macro You can configure the VMX210 to launch an automated macro in either of the following ways:

Link a macro to an alarm input point, so that a specific action can be executed automatically in response to an alarm. Refer to Configure Input/Output Points in this section for instructions.

Schedule a macro to run at a specific time through the Scheduler utility. Refer to Scheduled Events in the following section.

Icon Icon Name Function

Cut

Use these functions to cut, copy, and paste macro actions into a different order.Copy

Paste

Delete Delete a specific macro command.

Properties You can edit an individual command line in the macro with this function. Select a macro command line, and then click Properties.

View Camera Insert a macro command to switch the output of a specific camera to a specific monitor. In the View Camera dialog box, select the camera (Video Sources) and monitor (Video Destinations), and, if desired, select a Preset.

Run/Stop Sequence

Insert a macro command to run a sequence on a specific monitor. In the Run Sequence dialog box, select the sequence, monitor (Video Destinations), and the sequence action. A sequence must be created prior to creating a macro so that it appears on the list of sequences in the dialog box.

Load Profile Insert a macro command to load a particular camera profile to the appropriate camera. Refer to the Advanced Camera Controls section for information on creating camera profiles from the advanced camera properties sheets.

VCR Control Insert a macro command to execute an action on one of the system VCRs. If you select Record, the specified VCR will begin to record the source currently routed to it. To specify the video source routed to the specified VCR, include a View Camera command as an earlier step in the macro, with the VCR as the Video Destination.

Output Point Control

Insert a macro command to set any of the systems relay output points to True or False. Select the desired device and any one of the devices corresponding points.

Run External Application

Insert a macro command to start any external application stored on the workstation. Enter the desired application, command line arguments to locate and run the application, and the desired method for displaying the program window on the desktop.

Comm Port Output

Insert a macro command to send control data to any serial device that is not otherwise supported by VMX200. Select the desired COM port, and then enter the serial data string to be sent.

Load Site Map

Insert a macro command to load and display the specified site map.

Maintenance Insert a macro command to clean the alarm log and manual image capture files. You can eliminate alarm log entries based on acknowledged status or age. Note that all images associated with a particular log entry will be deleted along with it. Manual image captures may be deleted based only on a specified age basis.

34 C1534M (1/06)

Delete a Macro 1. From the Macros dialog box, select a macro from the list, and then click Delete.

2. Click OK to confirm the deletion. Note that the delete action cannot be reversed.

Duplicate a Macro Click Duplicate to save a copy of the macro with another name. This is useful for saving multiple copies of the same basic macro, each of which can be edited later for its specific purpose.

Create a Snapshot Macro The macros snapshot feature provides a means of recording current settings as a new macro. This might include displaying specific cameras on specific monitors, running sequences, and playing or recording VCRs.

Configure the system as desired. Once the system is displaying and performing the desired functions, complete the following procedure:

1. Open the Macros dialog box.

2. Click Snapshot. The Macro Name dialog box appears.

Figure 37. Snapshot Macro Name Dialog Box

3. Enter the macro name, and then click OK. If necessary, you can edit the snapshot macro; refer to Edit a Macro.

CONFIGURE SCHEDULED EVENTS

VMX200 provides a utility for scheduling macros to execute at specific times.

Open the Scheduled Events Dialog Box Select Automation > Scheduler from the menu bar. The Scheduled Events dialog box appears, displaying a list of all scheduled events.

Figure 38. Scheduled Events Dialog Box

C1534M (1/06) 35

Create a New Scheduled Event 1. From the Scheduled Events dialog box, click New. The Name dialog box appears.

2. Type the event name, and then click OK. The Edit Schedule dialog box appears.

Figure 39. Edit Schedule Dialog Box

36 C1534M (1/06)

3. Specify the event interval in the Run section and the Start At setting in the Start At section. Table D describes the schedule options:

Table D. Scheduled Events Schedule Options

4. In the Macro section of the Edit Schedule dialog box, select a macro from the drop-down box of available macros.

5. Click OK to return to the Scheduled Events dialog box.

6. Click Close to return to the site map window.

Run schedule Start At options

Monthly Specify the time of day and day of the month.

Hourly Specify how many minutes past the hour.

Weekly Specify the time of day and day of the week.

By Minutes Specify the interval in minutes.

Daily 1. Click Which Days, and then specify the appropriate days in the Which Days dialog box.

Figure 40. Which Days Dialog Box

2. Click OK to return to the Edit Schedule dialog box. 3. Specify the time of day the event is to run.

Sun Rise/Set 1. Click Setup to open the Sunrise/Sunset Setup dialog box, and then specify the appropriate settings:

Figure 41. Sunrise/Sunset Setup Dialog Box

Time: Select Sunrise or Sunset. Plus/Minus: Specify how many minutes before or after the event should run. Latitude/Longitude: Specify the latitude and longitude of the workstation site (needed for calculating the

exact time that sunrise and sunset will occur during the year).

By Seconds Specify the interval in seconds.

Once Specify the time of day and calendar date.

C1534M (1/06) 37

Edit a Scheduled Event 1. From the Scheduled Events dialog box, select the desired event, and then click Edit. The Edit Schedule dialog box appears.

2. Change the schedule options as necessary, and then click OK.

Rename an Event 1. From the Scheduled Events dialog box, select the desired event, and then click Rename.

2. Type a new event name, and then click OK.

Delete an Event 1. From the Scheduled Events dialog box, select the desired event, and then click Delete.

2. Click OK to confirm the deletion. Note that the delete action cannot be reversed.

Suspend or Resume an Event In the Scheduled Events dialog box, the Status column displays the current status of each event. When an event is Running, you can click Suspend to stop the event. When an event is Suspended, you can click Resume to restart the event.

CONFIGURE CAMERA AUXILIARY POINTS

Configure camera auxiliary points by completing the following steps from the site map window:

1. Select Configure > Auxiliary Points from the menu bar. The Auxiliaries dialog box appears.

Alternate Step 1 Right-click the appropriate camera icon, and then select Edit Auxiliary Points from the pop-up menu.

Figure 42. Auxiliaries Dialog Box

2. Select a camera from the Cameras drop-down box.

3. In the list of auxiliary points double-click one of the points listed. The Edit Point Properties dialog box appears.

Figure 43. Edit Point Properties Dialog Box

4. Edit the information in the following fields as necessary:

Point Name: Enter up to 64 characters. The point name is used to describe the point in the auxiliary control menus.

38 C1534M (1/06)

Point Logic: The point logic tells the system if the auxiliary point is normally open (NO) or normally closed (NC). This is used as the basis for sending appropriate control signals to the camera.

Momentary: Check this box to set the auxiliary point for momentary control.

5. Click OK to close the Edit Point Properties dialog box.

6. Click OK to close the Auxiliaries dialog box.

Refer to Operate Camera Auxiliaries in the Operation section for more information on controlling camera auxiliaries.

CONFIGURE INPUT/OUTPUT POINTS

VMX200 supports contact closure alarms and relay outputs from external units such as the CM9760-ALM and CM9760-REL. (VMX200 does not support camera alarms or video loss alarms.)

Configure the alarm input points and relay output points by completing the following steps from the site map window:

1. Select Configure > Input/Output Points from the menu bar. The Digital I/O Devices dialog box appears.

2. Select the device from the list of system devices, and then click OK. The Input/Output Points dialog box for the specific device appears.

Figure 44. Sample Input/Output Points Dialog Box

NOTE: The input/output point number used in VMX200 refers to the physical alarm input or relay contact number on the rear panel of the interface unit. VMX200 does not use the GPI numbers associated with relay contacts on the relay interface unit, or the alarm group numbers associated with the alarm inputs on the alarm interface unit.

C1534M (1/06) 39

3. In the list of specific input or output points, double-click one of the points listed. The Point Properties dialog box appears. The specific fields contained in the dialog box depend on whether you are editing points for an alarm interface unit (CM9760-ALM) or a relay interface unit (CM9760-REL).

Figure 45. CM9760-ALM (left) and CM9760-REL (right) Point Properties Dialog Boxes

4. Enter a Point Name (up to 64 characters) and then edit the information in the dialog box as necessary:

Alarm Interface Unit Alarm Actions: Specify what actions are required when the input point changes from its normal state.

To note the event in the alarm log, select Log This Message, and then enter an appropriate alarm log message.

To trigger a macro, select Run This Macro, and then select the desired macro from the drop-down box. To capture an image with the alarm, you must first configure a sequence to include the necessary image captures, and then configure a macro to run the sequence.

Refer to Configure Sequences and Configure Macros for more information.

Automatically Rearm: If you select this option, you also must specify a time delay value.

Relay Interface Unit Start-up Setting: For relay output points, click Enabled, and then select the start-up setting.

Point setting Description Last known value Start up with the output point in the same logic state (True or False) that was in effect when the system

was shut down.

True At startup, reset the output point to a true logic state.

False At startup, set the output point to a false logic state.

Note that the logic determines if True means On or Off. Example: for an output that turns a motor off when the output is true, set the point to True, and label the point Turn Motor Off.

NOTES: Alarm and relay contact settings (such as normally open/normally closed) are configured through the DIP switches on the alarm or relay

interface unit. These settings are duplicated in the configuration when you add the device (refer to the Reference Information for Adding Devices section in the Appendix).

The definition of True in depends on the DIP switch setting. For example, if you configure Alarm Group 1-16 in an alarm interface unit as normally open, then True equals open for alarm point 1 through point 16.

5. Click OK to close the Point Properties dialog box, and then click OK to close the Input/Output Points dialog box.

40 C1534M (1/06)

CONFIGURE FTP SETTINGS

If you configure a sequence to send an image capture file to an Internet file server, you must configure the FTP (File Transfer Protocol) server and network proxy server information.

Configure Network Proxies 1. Select Configure > FTP Sites from the site map window. The FTP Sites dialog box appears.

Figure 46. FTP Sites Dialog Box

2. Click Edit Proxies, and then click New. The Proxy Details dialog box appears.

Figure 47. Proxy Details Dialog Box

3. Complete the following fields according to your network design. Consult your network administrator for information on specific settings.

Name: Enter the name given to the proxy server.

Address: Enter the IP address or FTP address of the proxy server.

Port: Enter the appropriate port.

Logon Name: Enter the proxy servers login name.

Password: Enter the proxy servers login password.

Type: Select the appropriate proxy server logon type.

4. Click OK and then click Close.

C1534M (1/06) 41

Configure the FTP Server 1. From the FTP Sites dialog box, click New. The FTP Host Details dialog box appears.

Figure 48. FTP Host Details Dialog Box

2. Complete the following fields according to your network design. Consult your network administrator for information on specific settings.

Name: Enter the name given to the destination server.

Host: Enter the IP address or FTP address of the destination server.

Port: Enter the appropriate port.

Logon Name: Enter the destination servers logon name.

Password: Enter the destination servers logon password.

Confirm Password: Re-enter the destination servers logon password.

Upload Directory: Enter the specific target directory on the destination server (this entry is optional).

Connect Type: Select the appropriate connection type.

Proxy (Firewall): Specify any Proxy Server or firewall needed for Internet access.

3. Click OK.

42 C1534M (1/06)

CONFIGURE THE CAPTURE CARD

The capture card in the VMX210 workstation is configured to capture JPEG images.

If you need to change the capture card settings, complete the following steps:

1. Select Configure > Capture Card from the site map window. The Image Capture Configuration dialog box appears.

Figure 49. Image Capture Configuration Dialog Box

2. Select an appropriate file format (BMP or JPEG) according to the capability of the capture card.

If you select JPEG, set the Image Quality level. The higher the level, the better the quality. (A low setting equals higher compression levels, resulting in a smaller file size, but also a degradation of image quality.) The exact file size will depend on the image content.

3. Click OK.

CONFIGURE THE VIDEO FORMAT

VMX210 workstations are configured for NTSC at the factory. To change the video format complete the steps described below for the appropriate system:

VMX210 Quad Workstations (VMX210-SYS-Q) 1. Select Configure > Video Card Driver from the site map window. The Video Drivers dialog box appears.

2. Click Advanced. The Signal Type dialog box appears.

3. Select the appropriate format, and then click OK.

4. Click OK to close the Video Drivers dialog box.

VMX210 Single Video Workstations (VMX210-SYS-1) 1. Right-click in the video window, and then select Adjust Video from the pop-up menu. The Adjust Video dialog box appears.

2. Click Source. The Video Source dialog box appears.

3. Select the appropriate format, and then click OK.

4. Click OK to close the Adjust Video dialog box.

C1534M (1/06) 43

Operation VMX200 uses a simple drag and drop technique, taking advantage of the simplicity of a computer mouse. System functions are represented graphically by buttons or icons, or are featured in the menu system.

GETTING STARTED

START VMX210

1. Click the Windows Start button.

2. Choose Programs > VMX200 > VMX200.

If you installed the program in a folder other than VMX200, choose that folder from the Start > Programs menu.

3. The VMX200 splash screen appears. In about five seconds the Log-in dialog box appears.

Figure 50. Log-In Dialog Box

4. Enter your user name and password (both are case sensitive). Each user has a specific user profile and user preferences.

5. If desired, check or uncheck the Execute Startup Macro box. If this field is checked, the system will execute the users start-up macro immediately following the execution of the AutoRun Macro that initializes the VMX200 video windows.

Each users start-up macro is defined by the user in his user options. Refer to Change Start-Up Options in the Configure Users section.

6. Click OK. Once you log in, the VMX200 video window(s) and the site map window appear on the system monitor(s).

LOG IN AS A NEW USER

Each time a new user begins using the system, the user must first log in to the system in order to activate his specific user preferences.

1. Select File > Log in as a New User. The Log-in dialog box appears.

Figure 51. Log-In Command on the File Menu

2. Enter your user name and password, and then check or uncheck the Execute Startup Macro box.

3. Click OK. This will end the current session and open a new session for the new user.

44 C1534M (1/06)

NAVIGATE BETWEEN SITE MAPS

1. Move the mouse cursor over the site map. When you reach an area defined as a link, the cursor pointer changes to a hand. The destination map image file name is displayed in the status bar.

Figure 52. Sample Map Site Link Area

2. Double-click the mouse inside the link area. The new image map appears.

3. To return to the previously viewed map, click the Back icon that appears on the site map tool bar after you have used a link.

Figure 53. Back Icon

ALTERNATE STEP 3 Press the Esc key on the keyboard.

You can also change the active site map by opening a map image from the Maps dialog box. Refer to Open a Map Image in the Configure Site Maps section.

For information on creating links between facility image maps, refer to Create a Link to Another Site Map Image in the Configure Site Maps section.

OPERATING THE SYSTEM

SELECT A CAMERA

1. Click a camera icon on the facility map image, and then drag it to one of the VMX200 video windows.

2. Release the mouse button. Video from the selected camera is routed to the specified VMX200 video window.

Next/Previous 1. Click in a VMX200 video window to select it.

2. Press the F4 key to advance to the next camera installed on the switcher currently being viewed. The sequence of installed cameras is based on the system configuration, as programmed in the device configuration window.

OR

Press the F3 key to move to the previous camera installed on the switcher currently being viewed.

NOTE: If your system has more than one switcher, the Next and Previous commands cannot advance between switchers. Only the cameras on the switcher currently being viewed can be called with the Next and Previous commands.

C1534M (1/06) 45

Camera Following The Camera Following feature provides an easy way to follow an object across an area covered by multiple cameras, such as a person moving through a building, or a vehicle traveling along a roadway.

NOTE: An operator can also track objects through macros and/or using Next and Previous to step cameras along a route. However, the Camera Following functionality switches a group of cameras in one step, and does not require operators to remember macro numbers or camera numbers.

1. Click Automation on the site map window menu bar. If Automation does not appear on the menu bar, the user profile does not have permission to access this feature. If necessary, ask an administrator to turn it on.

2. A check mark next to Camera Following indicates that the feature is turned on. If necessary, click Camera Following to turn the feature on.

Figure 54. Automation Menu

3. Double-click a VMX200 video window. The Camera Following functionality varies, depending on the type of system:

Single video system Video from the associated camera(s) displays on the specified external monitor(s). If a site map has been associated with the camera, the new site map image appears in the site map window.

Quad system Video from the selected camera is routed to the first VMX200 video window. Video from the associated camera(s) is routed to the specified VMX200 video window(s). Video from associated camera(s) may also display on external monitor(s), depending on the configuration. If a site map has been associated with the camera, the new site map image appears in the site map window.

4. You can continue loading associated camera views by double-clicking any of the VMX200 video windows, or you can drag a camera icon from the site map image to display a different camera view. If necessary, Select Automation > Camera Following to remove the check mark and turn off the Camera Following feature.

CAMERA CONTROL

Once video has been routed to one of the VMX200 video windows, you can control the camera directly on the video image with the mouse. You can also control certain camera functions with the keyboard. Refer to Table E.

NOTE: The camera control functionality described here applies to the video on the VMX200 video windows only, not to any external monitors you may have connected to the VMX210 system.

Pan and Tilt Control Click and hold the left mouse button while the crosshair pointer is inside the selected VMX200 video window. The camera will follow the mouses movement.

The pan and tilt functions are under variable speed control. The further the mouse pointer is from the center of the VMX200 video window, the faster the pan and tilt movement.

You can also control pan and tilt functions with the arrow keys or the numeric keypad on the VMX200 keyboard. Refer to Table E for a description of keyboard control functions.

Zoom and Focus Control

Use the mouse wheel to zoom and focus the lens.

Zoom: While inside the selected VMX200 video window, roll the mouse wheel forward to zoom in and backwards to zoom out.

Focus: To focus, hold the Shift key while rolling the mouse wheel. If the camera features auto focus, the manual focus action will revert back to auto focus following any subsequent mouse movement.

46 C1534M (1/06)

Mouse wheel rolls are queued to allow a camera to be zoomed (or focused) in or out without having to continuously roll the wheel. If the wheel is rolled forward several times in quick succession, the user must roll the wheel backward one step in order to stop the zoom (or focus).

You can also control zoom and focus functions with the numeric keypad on the VMX200 keyboard. Refer to Table E for a description of keyboard control functions.

Iris Control When using a camera offering iris control, press the Alt key and roll the mouse wheel to adjust the iris setting on the camera. Cameras supporting auto iris will revert to their auto settings following any subsequent mouse movement.

Table E. Keyboard Camera Control

VIDEO WINDOW ADJUSTMENT

Quad Systems

You can adjust each VMX200 video window to fit the video source image exactly within the video window borders. To make adjustments, right- click the desired window and select Adjust Video from the pop-up menu. The Adjust Video dialog box appears. Adjust the following parameters for the selected window as necessary:

Left Change the left edge position; this value must be in multiples of 16.

Right Change the upper edge position; this value must be in multiples of two.

Horizontal offset Offset the video window left or right by increments of one from the position specified in the Left field.

Width Set the total width of the video window; this value must be in multiples of 16.

Height Set the total height of the video window, by increments of one.

Vertical offset Offset the video window up or down by increments of one from the position specified in the Top field.

You can also adjust the Contrast, Brightness, Saturation, and Hue as necessary.

NOTE: There always will be a black strip approximately 1 mm wide on the left side of the image. This is normal and does not affect the images being displayed or captured.

Single Video Systems The display card included with the single video workstations provides specific settings and video display controls. Right-click in the VMX200 video window, and then select Adjust Video from the pop-up menu. The Video Adjustment window displays the controls offered by the display card manufacturer. Refer to the Video-for-Windows card user manual for instructions on configuration settings.

VIEW AN EXTERNAL MONITOR

You can route camera output and other video sources to an external display monitor using the methods described below. PTZ control of cameras displayed on external monitors is limited to the keyboard functions described in Table E. To control PTZ function on these cameras with the VMX210 workstation mouse, display the same camera in a VMX200 video window and control the camera there.

Function Key(s) Description

Control/Display Monitor Selection Tab Press the Tab key to select the next control/display window in sequence

Camera Pan and Tilt Numeric Keypad Press the 2 (down) or 8 (up) key to tilt the selected camera. Press the 4 (left) or 6 (right) key to pan the selected camera. Press the 1 (left and down), 3 (right and down), 7 (left and up), or 9 (up and right) key for a pan and tilt combination.

Arrow Keys Press the up or down arrow to tilt the selected camera. Press the left or right arrow to pan the selected camera.

Camera Zoom and Focus Numeric Keypad Press the + key to zoom in. Press the - key to zoom out. Hold the Shift key, and then press the + or key to control the focus.

C1534M (1/06) 47

Route Video to an External Monitor 1. Drag a camera icon to the monitor icon on the site map tool bar.

Figure 55. Monitor Icon on Site Map Tool Bar

2. The External Monitors window appears.

3. Position the camera icon on the desired monitor and release the mouse button. The monitor will switch to video from the specified camera, and the External Monitors window closes.

Alternate Method 1. Double-click the monitor icon on the site map menu bar. The External Monitors window appears.

Figure 56. External Monitor Window

2. Drag a camera icon from the site map image to the External Monitors window.

3. Position the camera icon on the desired monitor and release the mouse button.

OPERATE A PRESET

Call a Preset 1. Right-click inside one of the PC video windows, and then select Go to Preset from the pop-up menu.

2. Select the desired preset position from the Preset submenu.

3. The camera moves to the preset position.

Call a Preset on an External Monitor 1. From the External Monitor window, right-click the desired external monitor icon, and then select the desired preset from the pop-up menu.

2. The camera moves to the preset position.

48 C1534M (1/06)

OPERATE SEQUENCES

Run a Sequence 1. Right-click inside one of the PC video windows, and then select Run Sequence from the pop-up menu. The Select Sequence dialog box

appears.

Figure 57. Select Sequence Dialog Box

2. Select the desired sequence, and then click OK.

Stop a Sequence Click inside one of the PC video windows to stop a sequence.

OR

Select Automation > Sequences > Stop All from the site map menu bar to stop all running sequences.

Run a Sequence on an External Monitor 1. From the External Monitors window, right-click the desired external monitor icon, and then select the desired sequence from the pop-up

menu.

2. The sequence will run until you right-click the external monitor icon and then select Stop Sequence or Pause Sequence from the popup menu.

OPERATE MACROS

Run a Macro Double-click any macro icon on any site map to run a macro manually.

OR

1. Select Automation > Macros from the site map window menu bar.

OR

Right-click the site map, and then select Macros from the pop-up menu.

C1534M (1/06) 49

The Macros dialog box appears.

Figure 58. Macros Dialog Box

2. Select the desired macro from the macro list, and then click Run.

3. Click Close to return to the site map window.

ALARM POINT EVENTS

VMX200 can respond to alarm input devices by logging events and executing specified macro automation events. For information on integrating alarm devices into VMX200, refer to Configure Input/Output Points in the Additional Configuration section.

View Alarm Events

Alarm events can be configured to generate an entry in the Alarm Viewer. These entries can be monitored in either of the following ways:

A user can open the Alarm Viewer manually when necessary, in either of the following ways. Select View > Alarms from the site map menu bar. Double-click an alarm point icon on the site map. An icon begins flashing when an event has occurred at the corresponding alarm point.

The icon continues to flash until the user acknowledges the event.

A user can choose to have the Alarm Viewer pop up whenever an alarm is set or reset. Refer to User Environment Options in the Configure Users section for information on this setting.

Figure 59. Alarm Viewer

The Alarm Viewer displays alarm events in reverse chronological order, with the most recent event at the top of the list. Each time a new alarm event occurs for a particular input device point, older events at the same device point are moved to a nested position under this newest event.

NOTE: The alarm point number used in VMX200 refers to the physical alarm input number on the rear panel of the alarm interface unit. VMX200 does not use the alarm group numbers associated with the alarm inputs on the alarm interface unit.

50 C1534M (1/06)

Alarm-Based Image Captures

To capture an image with an alarm, you must first configure a sequence to include the necessary image capture, and then configure a macro to run the sequence. Refer to Configure Sequences and Configure Macros in the Additional Configuration section for more information.

A camera icon next to an alarm event indicates that the system captured images associated with the alarm event. To view these image captures:

1. Select the event.

2. Click the View Images icon on the tool bar. The Capture Viewer appears.

Figure 60. Capture Viewer

The Capture Viewer displays a thumbnail picture of each image. Tool bar icons allow the user to filter images by date and time, and by camera, and to navigate between screens of captures, selecting and deleting images. Refer to the Image Capture section.

Acknowledge an Alarm In the Alarm Viewer, click the check box beside each event you wish to acknowledge. The check can be removed by clicking the check box again.

OR

Select the event you wish to acknowledge, and then click the Acknowledge icon on the Alarm Viewer tool bar.

Delete a Log Item Select the desired event, and then click the Delete icon in the Alarm Viewer tool bar.

NOTE: Deleting alarm events will remove the selected event(s) and all associated images. This action cannot be reversed. Pelco recommends saving a backup copy of any important image captures on external media, such as a CD.

Print the Alarm Log Click Print. The alarm log prints as it is currently displayed.

Manage Alarm Image Capture Files Alarm-related image capture files are stored within the system separately from manual image captures, but they can be managed in the same way. Refer to the Image Capture section for information on managing alarm-based image files.

C1534M (1/06) 51

OPERATE A VCR

Route Video to a VCR 1. Drag a camera icon to the VCR icon on the site map menu bar.

Figure 61. VCR Icon on Site Map Tool Bar

2. The VCRs window appears.

Alternate Steps 1 and 2 1. Double-click the VCR icon on the site map menu bar. The VCRs window appears.

2. Drag a camera icon from the site map image to the VCRs window.

3. Position the camera icon on the desired VCR and release the mouse button. The Route Image pop-up menu appears.

4. Select whether to route the video to the VCR and start recording, or just route the video. The VCRs window closes.

Figure 62. VCRs Window

Viewing Video That Is Being Recorded From the VCRs window, click the desired VCR icon and drag it to an appropriate VMX200 video window. The video that is being routed to the VCR is displayed on the VMX200 video window, along with the VCR control tool bar.

OR

Drag and drop the same camera that is routed to the VCR into a VMX200 video window. This allows the camera to be viewed and controlled through the VMX200 video window while it is being recorded on the VCR. This is useful in smaller systems when it is easy to remember which camera is being recorded.

VCR Control 1. Drag a VCR icon from the VCRs window to any of the VMX200 video windows.

2. Use the VCR control icons to control the selected VCR.

3. To change the camera routed to the VCR, click a new camera icon, and then drag it to the VCR icon.

Figure 63. VCR Control Icons

PTZ control of the camera viewed through the VCR is limited to the keyboard functions described in Table E. To control PTZ function on these cameras with the VMX210 workstation mouse, display the same camera in a separate VMX200 video window and control the camera there.

52 C1534M (1/06)

Alternate Method 1. In the VCRs window, select the desired VCR icon. The icon turns bright blue.

2. Use the VCR control icons to control the selected VCR. This option is used mainly for controlling a VCR when it is not being viewed.

Tape-To-Tape VCR Recording Each VCR can be treated as a video source as well as a destination. To record the contents of one VCR onto another, you must route the source VCR to the destination VCR.

1. In the VCRs window, drag one VCR icon (the source VCR) onto another VCR icon (the destination VCR).

2. Display each VCR in a VMX200 video window.

3. Press the Play icon for the source VCR.

4. Press the Record icon for the destination VCR.

Advanced Controls Each VCR has its own set of special controls for setting recording speed, time and date stamps, etc. To use these advanced controls:

1. From the VCRs window right-click the desired VCR icon, and then select Advanced Properties from the pop-up menu.

Alternate Step 1 If you are displaying the VCR video in one of the VMX200 video windows, right-click the window, and then select Advanced Properties from the pop-up menu.

2. The Advanced Properties dialog box appears. Refer to the appropriate TLR3000 Series VCR Installation/Operation Manual.

Figure 64. VCR Advanced Properties Dialog Box

C1534M (1/06) 53

IMAGE CAPTURE

The format of the image file created depends on the settings selected when the system administrator configured the capture card. Refer to Configure the Capture Card in the System Configuration section.

Image Capture Methods You can capture an image using any of the following methods:

Manual capture

Hot-key capture

Incorporate a capture command into an automated event

Manual Capture Right-click the desired VMX200 video window, and then select Capture from the pop-up menu to capture the frame.

Figure 65. Right-Click Pop-up Menu

Hot-Key Image Capture Use the following function keys on the keyboard to capture images in the VMX200 video windows:

Function Key VMX200 Video Window Number F5 1 F6 2 (quad system only) F7 3 (quad system only) F8 4 (quad system only)

Automated Capture Events You can include a command to capture an image in both sequence and macro events. Specify a capture command when designing an appropriate sequence event. Any macro that includes this sequence also will execute the capture. Refer to Configure Sequences in the Additional Configuration section for more information.

54 C1534M (1/06)

Open the Capture Viewer All captured images can be viewed, sorted, printed, and deleted through the Capture Viewer.

1. Select View > Captures from the site map window.

2. The Capture Viewer appears.

Figure 66. Capture Viewer

3. The Capture Viewer displays images captured from all system cameras. To view images from a specific camera, click the appropriate folder in the folder list.

Figure 67. Capture Viewer Folder List

The Capture Viewer tool bar contains the following icons:

Table F. Capture Viewer Icons

Icon Icon Name Function

Open Open the selected image in the Frame Capture Viewer.

Copy Copy the selected image.

Print Print the selected image(s).

Refresh Update the image set with any new images that have been captured since the Capture Viewer was opened. Images captured while the capture viewer is open will not be displayed until the refresh button is clicked. The number of queued images appears in the Capture Viewer status bar.

Delete Delete the selected image.

Configure Filter Filter the image captures by date and time.

Clear Filter Clear the settings selected in the Filter dialog box.

C1534M (1/06) 55

Filter Images 1. Click the Filter icon on the Capture Viewer tool bar. The Filter dialog box appears.

Alternate Step 1 Select View > Filter from the Capture Viewer menu bar.

Figure 68. Filter Dialog Box

2. Select the filter settings from the following options:

Previous This option displays the images captured during the specified previous time period; specify the number of minutes, hours, or days.

Between This option displays the images captured during the specified time interval. Select dates from the calendars that appear when you click the down arrows. If necessary, you can filter the search further by specifying the time of day during the search days (such as between 8:00 AM and 4:00 PM on each day from August 24 to 28).

Figure 69. Filter By Date and Time

Sort Images 1. Select View > Sort By from the Capture Viewer menu bar, and then select the sort option. You can sort either by date/time or by camera

name.

2. If necessary, select View > Sort Order to specify ascending or descending order.

56 C1534M (1/06)

Select Images

In the Capture Viewer, you can select one or more capture images for printing or deleting by using any of the following methods:

To select an individual image click the image

To select all images shown in the Capture Viewer, use Ctrl-A, or select Edit > Select All from the Capture Viewer menu bar.

To select a group of images press and hold the Ctrl key, and then click the desired images.

To select a sequence of images click and drag the mouse to draw a box around the desired images. The selected images are highlighted.

NOTE: To invert the selection (deselect the previously selected images, and select all of the previously unselected images) click Edit > Invert Selection from the Capture Viewer menu bar.

Figure 70. Select a Sequence of Images

Copy an Image 1. Select an image, and then click the Copy icon.

2. The image is copied to the system clipboard. You can then paste the image into another application.

Save Image Captures Pelco recommends saving a backup copy of any important image captures on external media, such as a CD. Image captures are stored in the Program Files\CamControlSvr\AlarmImage folder. Manual captures are saved in the IDO subfolder.

The VMX210 system includes a Read/Writer CD drive, which you can use to create a CD backup of image captures. Follow the CD creation instructions provided in the CD software.

Delete Images Select one or more images, and then click the Delete icon.

C1534M (1/06) 57

You can also delete images with a macro. Create a macro containing a Maintenance event set to remove images according to the specified time frame, as shown in Figure 72.

Figure 71. Maintenance Macro Set to Delete Captures

NOTE: To optimize hard disk space, delete images regularly. A maximum of 32,000 images is allowed. Once you have deleted an image, you cannot restore it to the system.

Open an Image Select an image and then click the Open icon on the Capture Viewer tool bar. The full-size image appears in the Frame Capture Viewer.

Alternate Method Double-click an image.

Figure 72. Frame Capture Viewer

Print Images

Print Thumbnail Images 1. Select the desired image(s), and then click the Print icon on the Capture Viewer tool bar. A standard Windows print dialog box appears.

2. Select the appropriate print options.

3. Click OK. The image(s) print on the specified printer.

58 C1534M (1/06)

Print a Full-Size Single Image

1. Open an image in the Capture Viewer.

2. From the Frame Capture Viewer menu, select File > Print. The image is printed with the filename and date stamp as displayed in the viewer window.

ALTERNATE Step 2 Select File > Print Setup to modify the printer settings, and then click Print.

NOTE: To use the print function, you must have a printer connected to the VMX210 workstation parallel port. Refer to the Windows 2000 documentation for printer installation instructions.

OPERATE AUXILIARIES AND OUTPUT POINTS

Operate Camera Auxiliaries Camera auxiliaries defined through the camera device configuration procedures may be controlled from VMX200 through the following steps:

1. Drag the desired camera into one of the VMX200 video windows.

2. Right-click the VMX200 video window, and then select the appropriate auxiliary from the pop-up menu. The device is turned on.

If you display the pop-up menu again, you will see that the selected auxiliary control now has a check mark next to it. Once an auxiliary is on, it will remain on until it is turned off or the system is shut down.

3. To turn the auxiliary off, display the pop-up menu and select the auxiliary. The check mark disappears.

Digital Output Point Controls You can use VMX200 to control external relay devices such as lights, gates, or motors using the systems digital output controls. Refer to Configure Input/Output Points in the Additional Configuration section for instructions on configuring relay output points.

1. Select Automation > Digital Output Control from the site map menu bar. The Output Control window appears.

Figure 73. Digital Output Control Window

2. All output points for the specified device are displayed on the right side of the window.

NOTE: The output point number used in VMX200 refers to the physical relay contact number on the rear panel of the interface unit. VMX200 does not use the GPI numbers associated with relay contacts on the relay interface unit.

Use the following output control icons to change the state of each relay output point:

C1534M (1/06) 59

Table G. Output Control Icons

Logic state example: A floodlight is normally off. The output point is configured to represent off as a false state. When you click the true icon, the floodlight is turned on. Refer to Configure Input/Output Points in the Additional Configuration section for additional information on output point startup configuration.

NOTES:

Relay contact settings (such as normally open/normally closed) are configured through the DIP switches on the relay interface unit. These settings are duplicated in the VMX200 configuration when you add the device (refer to the Reference Information for Adding Devices section in the Appendix).

The definition of True in VMX200 depends on the DIP switch setting. For example, if you configure relay contacts 1-16 in a relay interface unit as normally open, then True equals open for VMX200 relay point 1 through point 16.

ADVANCED CONTROLS

Advanced Camera Controls To access the advanced controls for a camera, right-click the camera icon on the site map image, and then select Advanced Controls from the pop-up menu. Or you can right-click the mouse in the VMX200 video window displaying the desired camera, and then select Advanced Controls from the pop-up menu.

Figure 74. Sample Camera Advanced Properties Dialog Boxes: General Tab (left) and Advanced Tab (right)

The Advanced Properties dialog box provides a way to configure a cameras special features. The specific fields contained in the dialog box vary, depending on the features supported by the camera. For example, with a Spectra camera, you can configure settings such as camera labels, lens speed, and patterns. The Display Properties button on the Advanced page opens the camera menu. The circle button below the Display Properties button controls iris open and iris close.

In some cases, the Advanced Properties dialog box contains a Profile tab. Use this page to save camera settings as a specific Profile for that camera. Profiles are loaded manually or through an automated macro. This is a useful feature for outdoor cameras that must adjust their exposure for varying light conditions during the day.

Click the Driver Logs tab to view error messages related to the device driver. If system cameras are controlled by Coaxitron through a switcher, the driver log displays errors related to the switcher driver, since commands to move cameras are sent to the switcher. If system cameras are not controlled through a switcher, the camera driver log displays camera errors and timeouts.

The driver log is a good troubleshooting tool, especially when used in combination with the Diagnostic Log. Refer to View the Diagnostic Log in the Troubleshooting section of the Appendix.

Icon Icon Name Function

Momentary True/False Click this icon to momentarily change the output points state to true. When you release the icon, the output points state returns to false.

True Click this icon to set the selected point to true. This icon appears pressed down when the output point is in a true logic state.

False Click this icon to set the selected point to false. This icon appears pressed down when the output point is in a false logic state.

60 C1534M (1/06)

Advanced CCTV Device Properties VMX200 provides access to the advanced properties of other CCTV devices through a dialog box specifically designed for each device.

Advanced Control for an External Monitor or VCR 1. Open the external device window.

2. Right-click the device icon, and then select Advanced Controls from the pop-up menu. The appropriate Advanced Control dialog box appears.

Figure 75. External Device Advanced Properties

Advanced Control for a Switcher or Multiplexer 1. Select View > Advanced Properties > Switchers from the site map menu bar.

2. Select the specific switcher or multiplexer. The appropriate Advanced Control dialog box appears.

NOTE: This option is restricted under User Permissions.

Figure 76. Advanced Properties Menu Option for CM6800

C1534M (1/06) 61

Appendix

THE VMX200 SITE MAP WINDOW The VMX200 site map window contains the following sections:

Menu bar

Tool bar

Site map image

Status bar

SITE MAP MENU BAR

Mouse Operation 1. Click the desired menu; the drop-down menu appears.

2. Click the desired command in the drop-down menu.

Keyboard Operation 1. Press Alt + underlined letter (for example, Alt+F for File); the drop-down menu appears.

2. Use the up or down arrow key to navigate to the desired option.

3. Press Enter.

Figure 77. Site Map Menu Bar

62 C1534M (1/06)

Table H describes the commands available through the site map menu bar.

Table H. Site Map Menu Bar Commands

Menu Command Function

File Log in as a New User Open the Log-In dialog box for the next user.

Exit Exit the VMX200.

Edit Site Map Select the Site Map image editing mode.

Options Open the user-specific settings dialog box.

View Advanced Properties Open Advanced Properties for any switchers or multiplexers that offer advanced controls.

Alarms Open the Alarm Viewer, which displays the alarm log.

Captures Open the Capture Viewer.

FTP Activity Open the FTP Activity Log. This log displays a record of communications.

Icon Labels Click to remove or add a check mark next to each type of icon; a check mark indicates that the label will be displayed on the site map for that type of icon.

Modem Activity This is reserved for future use.

Diagnostic Log Open the Log Viewer, which is a log of system events. This log is used primarily for support diagnostics.

Configure Devices Open the Device Configuration window.

Auxiliary Points Open the Auxiliaries dialog box for configuration of camera auxiliary points.

Input/Output Points Open the devices Point Properties dialog box for configuration of input/output points.

Maps Open the Maps dialog box for adding and renaming facility map images.

Users Open the Configure Users dialog box where user preferences are specified.

FTP Sites Open the FTP Sites dialog box for configuration of remote servers and firewalls.

Sockets This is reserved for future use.

Video Card Driver Open the configuration settings for the Video-For-Windows card installed on the VMX210. NOTE: Do not change this setting. For proper video functionality, 41VP (version 2) must be designated as the video overlay option.

Capture Card Open the Capture Card Configuration dialog box for editing file format and compression.

External Monitors Window

Open the appropriate device window for editing the layout of the installed devices.

VCRs Window

Automation Sequences

Edit Create or edit a sequence from the Sequences dialog box.

Stop All Stop all currently running sequences.

Macros Open the Macro Editor dialog box.

Scheduler Open the Scheduler dialog box.

Digital Output Control Open the Digital Output Control dialog box from which external devices can be activated.

Camera Following Enables the Camera Following feature.

Utilities Database Utilities

Backup Generate a backup copy of the workstation database.

Restore Open and restore a backup copy of the workstation database.

Compact Compact the database currently being used.

Help About VMX200 Displays VMX200 software registration and version information.

C1534M (1/06) 63

SITE MAP ZOOM ICONS

The site map zoom icons increase and decrease the size of the currently displayed map image. To use the Zoom In icon, click Zoom In, and then click the site map. Release the mouse button or drag a box around the specific section of the map. that you want to enlarge.

Figure 78. Site Map Zoom Icons

SITE MAP STATUS BAR

The status bar provides the following information:

A prompt identifying a link to another site map

Macro status information

The current time, as defined in the VMX210 workstation operating system

Figure 79. Site Map Status Bar

64 C1534M (1/06)

THE VMX210 DEVICE CONFIGURATION WINDOW

DEVICE CONFIGURATION WINDOW MENU BAR

Figure 80. Device Configuration Window Menu Bar

Table I describes the commands available through the Device Configuration window Menu Bar.

Table I. Device Configuration Window Menu Bar Commands

Menu Command Function

File Revert Revert to the last saved configuration settings.

PageSetup Open the page setting dialog box.

Print Preview Previews print job with current page settings.

Print Open print job dialog box.

Close Close the Device Configuration window.

Edit Copy Copy the selected object.

Paste Insert the copied object.

Paste Many Insert a specified number of copies of the object.

Delete Remove the selected object from the configuration diagram.

Select All Select all objects on the configuration diagram.

Find Device Locates a specified object on the configuration diagram.

Mirror

Horizontally Flip selected device icons around a vertical axis (left to right).

Vertically Flip selected device icons around a horizontal axis (top to bottom).

Device Inventory The Device Inventory allows you to save installation details of any system device without having to include it on the device configuration diagram.

Open Open the Device Inventory window.

Move Selected To Move the selected device directly to the Device Inventory without opening the Device Inventory window.

Add Add the designated device to the system configuration. Select from the list of devices displayed on the submenu. For each device, complete the fields in each dialog box, and then click Next to continue to the subsequent dialog box until the device configuration is complete.

Properties Open the Device Details dialog box for the selected object.

View Zoom You can zoom the diagram view. Select from the following list of zoom settings, which are displayed on the submenu. To Page (accommodate all icons in the viewing area) 100% 75% 50% 25%

Show Switch Paths Display the current status of all system video and audio switch paths on the diagram.

Labels Click to remove or add a check mark next to each type of device; a check mark indicates that the device label will be displayed on the diagram for that type of device.

Node Legend Toggles the configuration screens node color legend on and off.

C1534M (1/06) 65

DEVICE CONFIGURATION WINDOW TOOL BAR

Figure 81. Device Configuration Window Tool Bar

Table J describes the icons available on the Device Configuration window tool bar.

Table J. Device Configuration Window Tool Bar Icons

Icon Icon Name Menu Bar Command Function

Print Print Open print job dialog box.

Copy Edit > Copy Copy the selected object.

Paste Edit > Paste Insert the copied object.

Properties Edit > Properties Open the Device Details dialog box for the selected object.

Zoom In The menu bar does not containfunctions equivalent to these icons. with this tool. Use the View > Zoom functions instead.

Enlarge a specific area of the diagram by dragging a box with this tool. You can also use this tool to center a specific area of the diagram by clicking it on the desired area.

Zoom Out Use this tool to zoom out in increments.

Zoom Selected Use this tool to focus on a specific object or group of objects.

Zoom 1 to 1 Use this tool to revert to the default drawing size.

Zoom to Page Use this tool to display the entire area available to the configuration diagram.

Add Camera Edit > Add > Camera Add the designated device to the system configuration.

Add Switcher Edit > Add > Switcher

Add External Monitor Edit > Add > External Monitor

Add VCR Edit > Add > VCR

Add Input/Output Device Edit > Add > Input/Output Device

Add DVR Edit > Add > DVR This is reserved for future use.

Add Modem Edit > Add > Modem This is reserved for future use.

Add Avitech VCC4 This is not available on the menu bar.

This is reserved for future use.

66 C1534M (1/06)

REFERENCE INFORMATION FOR ADDING DEVICES The dialog boxes for adding devices contain instructions for completing the entry fields. If you need further assistance, refer to the field definitions provided below.

ADD A CAMERA

General Information

Name: Enter a camera name (up to 64 characters). This name can contain letters, numbers, and symbols.

Location: Enter a description of the camera location, such as Parking Lot B (up to 255 characters). This text is displayed in the title bar of the video display window when the camera is selected.

Description: Enter any other relevant information, such as the camera serial number or specific communications settings (up to 255 characters).

Camera Capabilities

Pan, Tilt, Zoom, Focus, Iris: Select the appropriate options that the camera provides. Leave all options unchecked for fixed cameras.

Presets: If your camera stores preset positions, check this option.

Auxiliary Contacts: Check this option if your camera has options such as a wiper blade or lamps that require operator control.

Positional Feedback: This is reserved for future use.

Control Commands

Coaxial Cable: Check this option if both video data and control data are sent to and from the camera along the same coaxial cable, through either a switcher or a multiplexer.

Switcher Serial Port: Check this option if the cameras control data is to be sent serially through a matrix switcher or multiplexer.

PC Serial Port (or Modem): Check this option if the cameras control data will be sent serially (such as with RS-232) from the VMX210 or through the Ethernet COM port.

Make and Model This dialog box appears only when you add a camera that is controlled serially through the VMX210 communications port.

Manufacturer: Select Pelco.

Model: Select the appropriate camera model.

Camera Addressing Cameras that are controlled serially through the VMX210 communications port or a switcher control port must be addressed to ensure proper communication with the system.

Automatic Addressing: Select this option if the cameras are controlled by Coaxitron. If the cameras are controlled by D or P protocol, you can use automatic addressing provided the camera addresses match the switcher input numbers (camera 1 to input 1, and so on). Automatic addressing assigns the camera an address that is the same as the logical number of the switching device node that it is connected to. If physical/logical mapping has been applied to the switching device, then the cameras address will be taken from the logical number of the input port instead of the physical port number. If the camera is connected to multiple switching devices, the cameras address will be taken from the first node it is connected to.

Manual Addressing: Enter an address number corresponding to the address (DIP switch setting) on the camera. If more than one camera is installed on the same serial line (such as in a daisy-chain configuration from the VMX210 serial port), each camera must have a unique address. Changes in switcher physical/logical mapping have no effect on communications with manually addressed cameras.

Preset Capacity

Number of Presets: Enter the number of camera presets, if the camera supports presets.

Auxiliary Contacts

Number of Auxiliary Contacts: Enter the number of auxiliary contacts in the camera, if applicable.

C1534M (1/06) 67

ADD A SWITCHER

Use Add a Switcher to add matrix switchers and Genex multiplexers to the system configuration.

General Information

Name: Enter a switcher name (up to 64 characters). This name can contain letters, numbers, and symbols.

Location: Enter a short description of the switchers physical location (up to 255 characters).

Description: Enter any other relevant information, such as the serial number (up to 255 characters).

Make and Model

Manufacturer: Select Pelco.

Model: Select the appropriate switcher model.

Device Addressing Switchers that are controlled serially through the VMX210 communication port must be addressed to ensure proper communication with the system.

Select Manual Addressing, and enter an address number corresponding to the address (DIP switch setting) on the switcher itself. If more than one switcher is installed on the same serial line (such as in a daisy-chain configuration), each switcher must have a unique address.

NOTE: For the CM9760 switcher the address must match the PIN number of the CM9760-KBD. For the Genex multiplexer the address must match the GenexUnit ID number (for example, Unit ID 1 = address 1).

Video Inputs and Outputs

Number of Video Inputs/ Number of Video Outputs: Enter the number of video input and output connections on the switcher. If necessary, refer to the

switchers installation/operation manual.

Physical/Logical Mapping: This optional feature provides a means of assigning a non-sequential numbering system to the physical inputs and outputs of a matrix switcher. Note, however, that this VMX210 mapping information cannot be transmitted to the matrix switcher.

Control Ports

Number of Switcher Control Serial Ports: Enter the number of switcher control ports.

Number of Camera Control Serial Ports: Enter the number of camera control ports on the switcher.

ADD AN EXTERNAL MONITOR

The VMX210 quad workstation (VMX210-SYS-Q) can support multiple external monitors connected to any output port on an external switcher or an available output port on the VMX210.

General Information

Name: Enter a monitor name (up to 64 characters). This name can contain letters, numbers, and symbols.

Location: Enter a short description of the monitors physical location (up to 255 characters).

Description: Enter any other relevant information, such as the serial number (up to 255 characters).

NOTE: This information is for VMX210 system reference only. The text entered in these fields does not appear on system monitors.

68 C1534M (1/06)

ADD A VCR

General Information

Name: Enter a VCR name (up to 64 characters). This name can contain letters, numbers, and symbols.

Location: Enter a short description of the VCRs physical location (up to 255 characters).

Description: Enter any other relevant information, such as the serial number (up to 255 characters).

Make and Model

Manufacturer: Select Pelco.

Model: Select the appropriate VCR model.

Device Addressing

VCRs that are controlled serially through a VMX210 communication port must be addressed to ensure proper communication with the system.

Select Manual Addressing, and enter address 0 unless the VCRs internal setting is different.

ADD A DIGITAL INPUT/OUTPUT DEVICE

VMX210 uses digital input/output device types for handling inputs from alarm interface units or sending on/off signals to external relay devices.

General Information

Name: Enter a device name (up to 64 characters). This name can contain letters, numbers, and symbols.

Location: Enter a short description of the devices physical location (up to 255 characters). This text is displayed in the title bar of the video display window when the device is selected.

Description: Enter any other relevant information, such as the serial number (up to 255 characters).

Make and Model

Manufacturer: Select Pelco.

Model: Select the appropriate model number.

Dip Switch Settings

Set the DIP switch settings to match the settings on the front panel of the alarm or relay unit.

Point Configuration

You can configure the alarm input points or relay output points at this time, or you can configure them at a later time. Refer to Configure Input/ Output Points in the Additional Configuration section.

C1534M (1/06) 69

SOFTWARE INSTALLATION AND REGISTRATION Please call Pelcos 24-hour Technical Support at 1-800-289-9100 or 1-559-292-1981 before installing an upgrade or reinstalling the VMX200 software from CD.

VMX210 SOFTWARE REINSTALL

The following instructions are necessary only in the event that you need to reinstall the software. Do not complete these instructions unless advised to do so by a Pelco Technical Support representative.

1. Uninstall the previously installed VMX200 software.

a. Click the Windows Start button.

b. Choose Settings > Control Panel.

c. Select Add/Remove Programs.

d. Select the VMX200.

e. Click Add/Remove or Change/Remove (Windows 2000).

NOTE: When you reinstall the VMX200 software, the existing database from the previous installation will be recognized and used for the new installation. You should not change the installation directory when reinstalling the VMX200 software, otherwise the existing database will not be found.

2. When the uninstall process is complete, close all programs on the VMX210 workstation.

3. Insert the VMX210 Resource CD into the CD drive on your VMX210 workstation.

4. The VMX200 Installation and User Guide window appears.

If it does not appear:

a. Select the Windows Start button.

b. Select Run.

c. Type D:\setup.exe (if necessary, substitute the appropriate letter of your CD drive for D).

5. Select Install VMX200.

6. Follow the on-screen instructions to complete the installation.

7. When the installation is complete you will be prompted to enter the Base License; see License ID below.

NOTE: When you reinstall the VMX200 software, the existing database from the previous installation will be recognized and used for the new installation. You should not change the installation directory when reinstalling the VMX200 software, otherwise the existing database would not be found.

70 C1534M (1/06)

SOFTWARE REGISTRATION

The first time you start the VMX200 software, a message box prompts you to enter a Base License. Click Yes to open the Add License dialog box.

1. Enter your License ID in the Add License dialog box.

The License ID (a two-part number) is printed on a sticker located on the VMX210 CD case. The Hardware ID is entered by Pelco at the factory.

LICENSE ID

NOTE: Once you have entered your License ID, you must obtain your Activation Code (Step 2) and then enter it (Step 3) within 30 days.

2. Obtain your Activation Code:

a. Open your Internet browser and go to the VMX210 Activation page at Pelco.com. https://www.pelco.com/ vmxactivation/ (Note the s in https this is a secure server address.)

b. Enter your Hardware ID and License ID, and then complete the remaining fields.

c. Click Activate. A confirmation screen appears, containing your Activation Code.

OR

Call Pelco Technical Support: 1-800-289-9100 or 1-559-292-1981

C1534M (1/06) 71

NOTES: To refer to the Installation ID or Activation Code at a later time, complete the following steps: 1. Select Help > About VMX200 from the menu bar, and then click Registration. The My Licenses dialog box appears.

2. Click your license, and then click Properties. The License Properties dialog box appears.

3. Enter your Activation Code in the Add License dialog box.

4. Click Apply.

5. Click Close.

72 C1534M (1/06)

FEATURE UPGRADE REGISTRATION - FOR FUTURE USE

When you purchase a feature upgrade, Pelco will send you a software License ID number. Complete the following steps to upgrade the software:

1. Select Help > About VMX200 from the menu bar. The About VMX200 dialog box appears.

2. Click Registration. The My Licenses dialog box appears.

3. Click Add. The Add License dialog box appears.

4. Follow the instructions provided in the Software Registration section.

CCTV DEVICE DRIVERS

Hardware such as cameras, switchers, and VCRs require special filesdevice driversthat tell the VMX210 how to communicate with them. A current set of device drivers and corresponding command databases are installed with the VMX200 software.

If you need to install additional device drivers or update existing drivers complete the steps in the following sections.

Install a New Device Driver

1. Follow the steps for adding the new device as described in the System Configuration section of this manual.

2. When you reach the Make and Model dialog box, click the Have Disk button.

3. In the file manager window, select the .cci file from the disk containing the new driver, and then click Open. The .cci file is the device drivers setup file, which will manage the installation.

4. Select the device and click Next. The device then will be available in the manufacturer/model window.

5. Complete the remaining device configuration wizard screens.

This device driver now will be available when adding another device of that type.

Update a Device Driver

1. Open the Device Configuration window.

2. Double-click the device icon on the diagram for which you wish to update. The device details dialog box appears.

3. Click the Make/Model tab or the Control tab (the tab name depends on the device type), and then click Have Disk.

4. In the file manager window, select the .cci file from the disk containing the new driver, and then click Open.

5. Select the desired device from the list.

NOTE: A warning appears if the driver being installed is older than the one currently installed in the system. If you are unsure whether to continue with the installation, contact Pelcos 24-hour technical support for assistance.

6. Click OK to close the device details dialog box and to accept changes. The new driver now will be available any time you wish to add another device of that type. This process also updates all other existing instances of the device.

TROUBLESHOOTING

VMX200 Software Unexpectedly Quits If the software unexpectedly quits, make a note of the following information:

Actions and events immediately prior to the shut-down

The screen from which the error occurred

Any error messages that were displayed

Then restart VMX210. Should the system fail to restart, refer to the Emergency Backup and Restore Procedures section for system recovery information.

If the system quits again under the same conditions as the first failure, contact Pelco immediately and report the conditions that preceded the event in both instances.

C1534M (1/06) 73

The Software Requires a Backup Database During a Restart If the VMX210 suffers a serious system error resulting in a corruption of the system configuration information, the software will prompt the user to specify an alternative database during system restart. Refer to the Restore the VMX210 Database section for instructions.

The Video Window Turns Black or Blue After Dropping a Camera This problem indicates that the selected cameras video link is broken. This may be the result of a fault at the camera, the video cables, the switcher connections, or the system configuration diagram. Use the following checklist to determine the location of the fault.

NOTE: A black video window indicates a problem between the camera and the switcher. A blue video window indicates a problem between the switcher and the VMX210 workstation.

Verify camera operation: Check the camera to ensure that it is receiving power and has not sustained any damage.

Verify camera configuration: Open the device configuration window and confirm that the camera is connected properly to a switcher or the main VMX210 video inputs in exactly the same way that it is connected physically.

Test cables and connections: Check the system cables and connectors with cables and connectors that are known to be functioning correctly.

Presets Have Moved From Their Original Positions Check the cameras mounting structure to ensure that no camera movement has occurred or is possible. If the problem persists, it is likely a problem with the camera hardware. Contact your camera manufacturer.

NOTE: Some cameras will lose their preset settings when the dome is changed.

Incorrect Cameras Are Being Displayed When an Alarm Is Activated This type of error can be the result of either an incorrect macro specification in the alarm (digital input point) configuration or incorrect camera specification within the alarms macro. Verify that both the macro and alarm configuration have been designed properly.

A Facility Map Image Will Not Load Properly or at All Verify that the desired image is in the Video Management Software Site Maps directory and has been saved in one of the acceptable image file formats (.jpg, .bmp, .wmf, .emf, and .gif). If the image is too large or small, it must be edited to an acceptable size for the Video Management Software map window (1016 x 673, 16-bit color is ideal).

Blue Lines Remain on the Facility Map Image After Closing the Map Edit Tool Bar This error will occur after drawing an image link area but not specifying the linked map. This problem can be fixed by selecting File > Edit Image Map, right-clicking inside the identified link area, and selecting the desired linked image from the pop-up window.

Video is Displayed When a Camera is Dropped Onto a Video Window, but there is No Ptz Control This error is typically the result of a problem with the controls being sent to the cameras or with the control lines themselves. First, verify that the cameras installation details are correct with respect to how the camera is controlled and/or how the camera is addressed. The com port settings on the VMX210 workstation or other serial device distribution system should match the specifications for the serial devices connected to it. This includes baud rate, parity, and start and stop bits. If correcting these does not solve the problem, check all serial connections to ensure that there are no bad cables or connections, and check that the serial addressing within the camera matches what is specified within the VMX210.

The Capture Viewer Displays Blue Images or None at All Verify that there is a valid video source to capture an image from. If the video window Status Bar does not indicate a failure and the source can be viewed in any other video display window, restart the system and note any error messages that appear during device initialization.

A Video Window Displays the Simulated Video VMX200 will display a Simulated Video image if the systems display/control windowing board fails to initialize properly. Restarting VMX200 software will correct this problem.

The Control/Display Monitor Windows are Displaying a Green Tint This is another indicator that the windowing board failed to initialize properly. Power down the system completely (cold boot) and restart to correct the problem.

The Video Control/Display and Map Windows Are Not In the Desired Positions or Do Not Utilize the Additional Monitors Installed If the monitor and Windows desktop resolution settings are changed, window placement may not appear correctly. If this happens, the .ccm configuration file must be deleted so that the system is forced to re-create the file with the proper monitor resolution parameters. The file can be found in the WinNT\System32\ccsupp directory. Before deleting the .ccm file, ensure that the monitor and desktop resolution parameters within the Windows system control panel are configured properly.

The resolution of VMX210 workstation monitors are configured at the factory to 1024 x 768 so that the Windows desktop becomes multiples of these values. A dual monitor system is configured with a desktop resolution of 2048 x 768 (or 1024 x 1536). Note that monitors must also be set to 60Hz with high color depth (16 bit).

74 C1534M (1/06)

A special .ccm file editor program program, called Window Placement Editor, was installed with the control system and may be found under the Start menu. This utility program allows users to manage their systems window configuration through a simple interface. Contact Pelco for assistance.

View the Diagnostic Log Before contacting Pelco, refer to the Diagnostic Log to see if it detected errors. The Diagnostic Log records errors starting drivers and errors related to the VMX200 software (such as with macros or sequences). The Diagnostic Log also records when Macros are started.

1. Select View > Diagnostic Log.

2. Write down any unusual entries in the log.

3. When you discuss your system problem with Pelco, provide the technical support staff with the Diagnostic Log entries.

EMERGENCY BACKUP AND RESTORE PROCEDURES

Backup the VMX210 Database VMX200 makes a backup copy of the configuration database each time the configuration screen is closed successfully. A total of five backup files are retained, based on the most recent dates. Use the Backup utility to make additional copies and to save backup databases to alternative media. Pelco recommends also saving a copy of the database on external media (such as a CD).

Users with administration privileges can save the current database to a backup file name and location.

1. Select Utilities > Database Utilities > Backup from the map screen menu bar. The Save Database Backup As dialog box appears.

2. Type an appropriate filename, and then select a new location, if necessary.

3. Click Save.

Restore the VMX210 Database In the unlikely event that your VMX210 system suffers a serious system error resulting in a corruption of the system configuration information, the following steps should ensure that the system recovers smoothly:

1. Restart VMX210.

2. The system may prompt you to specify an alternative database. If not, select Utilities > Database Utilities > Restore. The Backup Databases dialog box appears.

Figure 82. Backup Databases Dialog Box

3. Select the most recent backup file from the backup files saved automatically by VMX210 or from the copies manually saved with the Backup utility described in the Backup the VMX210 Database Database section, above.

4. Click OK, and then restart VMX210.

The system will now perform properly. If problems still exist, contact Pelco immediately.

C1534M (1/06) 75

76 C1534M (1/06)

Index

A Add devices 9 Adjust video 47 Advanced camera controls 60 Advanced CCTV device properties 61 Alarm

view alarm events 50 Alarms

Acknowledge an alarm 51 add icon to site map 25 alarm interface unit 69 alarm viewer 50 alarm-based image captures 51 configure alarm input points 39 view alarm events 21

Automation 63 Auxiliary points, configure 38

B Backup 75

C Camera

add 67 add icon to site map 25 advance controls 60 operation 45 PTZ control 46

Camera auxiliary points configure 38 operation 59

Capture card, configure 43 Capture viewer 51, 55 CCTV device driver 73 CCTV devices, properties 61 Configuration

system 9 Configure

alarm input points 39 camera auxiliary points 38 capture card 43 external device windows 27 FTP settings 41 macros 32 presets 28 relay output points 39 scheduled events 35 sequences 29 site maps 22 users 18

Connect devices 12

D Daisy-chain serial communications 13 Database, backup and restore 75

Default Map 21 Device

configure 9 connections 12 Edit 11 icon 11 icon labels 15, 63 inventory 10, 65 properties 11

Device Configuration close 18 edit 13

Device configuration diagram 10 print 17 save 17 window 9

Device drivers 73 Diagnostic log 63 Digital input device, add 69 Digital output point 59 Drawing connections 12

E Edit

auxiliary point properties 38 device configuration 13 site maps 25

External device windows, configure 27 External Monitor

add 11, 68 External monitor

operation 47

F Feature upgrade 73 Filter images 56 Find device 17

I Image capture

filter 56 format 22 operation 54

Image captures alarms 51

Import, site map image 23 Install

devices 9 VMX210 8

Inventory device 10

L Label, device icon 15 Link

C1534M (1/06) 77

site map image 27 Log in 44 Log In as a New User 44 Log viewer 63

M Macro

add icon to site map 25 configure 32 operation 49 snapshot 35 startup 21

Map icon, resize 27 Map, start-up 24 Maps. See Site map Mirror 14 Monitor. See External monitor

N Network Proxies

configure 41 NTSC, select video format 43

O Operation

camera auxiliary points 59 cameras 45 digital output points 59 external monitor 61 image captures 54 macros 49 presets 48 PTZ control 46 sequences 49 site maps 45 VCR 52

Options, user environment 20

P PAL, select video format 43 Password 19 Permissions

user 19 Presets

configure 28 operation 48

Print device configuration diagram 17 image captures 58

Print Images 58 Properties

device 11 PTZ control 46

R Relay interface unit, operation 59 Requirements

system 9

Resize, map icon 27 Restore 75 Revert 17

S Save device configuration 17 Scheduled events, configure 35 Select camera 45 Sequence

configure 29 operation 49

Site map configure 22 edit 25 image 22 link 27 status bar 64 window 62 zoom icons 26

Snapshot macro 35 Start VMX210 44 Startup

macro 21 map 21 options 21

Status bar, site map 64 Switcher, add 68

T Troubleshooting 73

U Upgrade 73 User

configure 18 permissions 19 properties 19

User environment options 20 Username 19

V VCR

add 69 operation 52

Video window adjustment 47 View alarm events 50

Z Zoom icons, site map 26, 64

78 C1534M (1/06)

PRODUCT WARRANTY AND RETURN INFORMATION

WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.

Exceptions to this warranty are as noted below:

Five years on FT/FR8000 Series fiber optic products.

Three years on Genex Series products (multiplexers, server, and keyboard).

Three years on Camclosure and fixed camera models, except the CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models, which have a five-year warranty.

Three years on PMCL 200/300/400 Series LCD monitors.

Two years on standard motorized or fixed focal length lenses.

Two years on Legacy, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed dome products.

Two years on Spectra, Esprit, ExSite, and PS20 scanners, including when used in continuous motion applications.

Two years on Esprit and WW5700 Series window wiper (excluding wiper blades).

Two years (except lamp and color wheel) on Digital Light Processing (DLP) displays. The lamp and color wheel will be covered for a period of 90 days. The air filter is not covered under warranty.

Eighteen months on DX Series digital video recorders, NVR300 Series network video recorders, Endura Series distributed network-based video products, and TW3000 Series twisted pair transmission products.

One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.

Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes).

Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty.

Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelcos liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product lia- bility, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.

The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state.

If a warranty repair is required, the Dealer must contact Pelco at (800)289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information: 1. Model and serial number 2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number 3. Details of the defect or problem

If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written explanation with the product when returned.

Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.

RETURNS In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair).

All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.

Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate address below.

If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to: Service Department Pelco 3500 Pelco Way Clovis, CA 93612-5699

If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the following:

If the goods are to be sent by a COURIER SERVICE, send the goods to: Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA

If the goods are to be sent by a FREIGHT FORWARDER, send the goods to: Pelco c/o Expeditors 473 Eccles Avenue South San Francisco, CA 94080 USA Phone: 650-737-1700 Fax: 650-737-0933

This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.

REVISION HISTORY

Manual # Date Comments C1534M 1/06 Original version.

Pelco, the Pelco logo, Camclosure, Esprit, Genex, Coaxitron, Legacy, and Spectra are registered trademarks of Pelco. Endura and ExSite are trademarks of Pelco. Intel and Pentium are registered trademarks of Intel Corporation. Adobe and Photoshop are registered trademarks of Adobe Systems Incorporated AutoCAD is a registered trademark of Autodesk, Inc. Microsoft, Windows, and IntelliMouse are registered trademarks of Microsoft Corporation. DLP is a registered trademark of Texas In

Manualsnet FAQs

If you want to find out how the VMX200 Pelco works, you can view and download the Pelco VMX200 Software Installation Manual on the Manualsnet website.

Yes, we have the Installation Manual for Pelco VMX200 as well as other Pelco manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Installation Manual should include all the details that are needed to use a Pelco VMX200. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Pelco VMX200 Software Installation Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Pelco VMX200 Software Installation Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Pelco VMX200 Software Installation Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Pelco VMX200 Software Installation Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Pelco VMX200 Software Installation Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.