Pelco EC-1508CL-R Extender Operation Manual PDF

1 of 10
1 of 10

Summary of Content for Pelco EC-1508CL-R Extender Operation Manual PDF

C3944M / REV 02-18-14TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981

INSTALLATION AND OPERATION MANUAL

EC-1500 Series ETHERNETCONNECT EXTENDER WITH PASS-THROUGH POE TO 15 WATTS

The EthernetConnect EC-1500 series extends 10/100Mbps Ethernet over twisted pair cable or coax.

Single channel units can be powered locally or via Pass-Through PoE.

This manual serves the following Model Numbers: EC-1501U-M EC-1501C-M EC-1504U-W EC-1504C-W EC-1508UL-R EC-1508CL-R EC-1516UL-R EC-1516CL-R

TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981 C3944M / REV 02-18-14

IMPORTANT SAFETY INSTRUCTIONS

1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturers instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other.

A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.

10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the points where they exit from the apparatus.

11. Only use attachments/accessories specified by the manufacturer. 12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use

caution when moving the cart/apparatus combination to avoid injury from tip-over. 13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as

power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

14. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases shall be placed on the apparatus.

15. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. 16. Installation should be done only by qualified personnel and conform to all local codes. 17. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must

not be installed where exposed to rain and moisture. 18. Use only installation methods and materials capable of supporting four times the maximum specified load. 19. A CCC-approved power cord must be used to power this equipment when used in China. 20. CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not

perform any servicing other than that contained in the operating instructions unless you are qualified to do so.

The product and/or manual may bear the following marks: This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.

CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN.

C3944M / REV 02-18-14TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981

EC-1501X-M EC-1501X-M LOCAL REMOTE

PoE ETHERNET SWITCH

OR MIDSPAN

ETHERNET CONNECTION EXTENDED CONNECTION

C (COAXIAL) OR U (UTP)X

PoE POWER

POWERPOWERPOWER

ETHERNET SWITCH

EC-1501X-M EC-1501X-M LOCAL REMOTE

POWER

POWER

POWER

EC-1504X-W

PoE ETHERNET SWITCH

OR MIDSPAN

EC-1508XL-R EC-1504X-W

LOCAL EC-1504X-W EC-1501X-M

REMOTE

POWER POWER

POWERPOWER

POWER POWER

POWER POWER

POWER

EC-1516XL-R

POWERPOWER

POWER

EC-1501X-M

ETHERNET SWITCH

EC-1504X-W

LOCAL EC-1516XL-R EC-1501X-M

REMOTE

APPLICATION DIAGRAMS Note: Coaxial applications use EC-1500C modules; UTP applications use EC-1500U modules.

INSTALLATION AND OPERATION MANUAL EC-1500 SERIES

PoE Pass-Through Mode

Non-PoE Mode

Multichannel Non-PoE Application

Multichannel PoE Application

IMPORTANT NOTE. PLEASE READ. The network implementations are shown as general representations only and are not intended to show detailed network topologies. Your actual network will differ, requiring changes or perhaps additional network equipment to accommodate the systems as illustrated. Please contact your local Pelco representative to discuss your specific requirements.

TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981 C3944M / REV 02-18-14

INSTALLATION AND OPERATION MANUAL EC-1500 SERIES

INSTALLATION INSTRUCTIONS 1 - SET 10/100 SWITCH

Locate the 10/100 data rate DIP switch on the unit. Set the data rate according to bandwidth required. The default setting for the data rate DIP switch is 100Mbps. NOTE: The data rate must be set the same on both the local and remote units.

2 - SET WIRE PAIR DIP SWITCHES (UTP MODELS ONLY, FOR COAX MODELS SKIP TO STEP 3) Locate the wire pair DIP switch on the unit. Set the pair according to number of twisted wire pairs used (1 or 4). The default setting for the wire pair DIP switch is 4 pair. NOTE: The number of pairs selected must be set the same on both the local and remote units.

3 - SET LOCAL/REMOTE SWITCHES (1 AND 4 CHANNEL UNITS ONLY, FOR RACK UNITS SKIP TO STEP 4) Locate the Local/Remote Dip switch and set to LC at the head end or RM at the camera end. Locate the Local/Remote push button switch (coax units only), and set to the same setting as the dip switch. The factory setting for these switches is RM. The EC-1508xL-R and EC-1516xL-R units are preconfigured as Local devices.

4 - CONNECT EXTENDED WIRING Connect Extended Distance Port to field wiring.

5 - CONNECT NETWORK WIRING Using CAT5/5e, connect Local unit to network and Remote unit to camera.

6 - CONNECT POWER Connect power to unit per the following table:

Table 1 Power Connections per Use Case Unit Local Power Pass-Through PoE

EC-1501x-M

12 to 32 VDC or 18 to 32 VAC

Recommended Power Supply: Pelco Part# ECPS-12VDC-0.5A (12V 0.5A)

No external power required

EC-1504x-W 12 VDC (9 VDC when in a USRACK or EURACK)

Recommended Power Supply: Pelco Part# ECPS-12VDC-0.5A (12V 0.5A)

EC-1508xL-R EC-1516xL-R

12 VDC Recommended Power Supply: Pelco Part# ECPS-12VDC-3A (12V 3A)

or ECPS07-12VAC-3A Contact Pelco pre-sales support, or refer to the appropriate installation and operation manual when configuring and specifying power for a deployment.

7 - VERIFY FUNCTIONALITY See LED table below and Troubleshooting Guide if corrective action is needed. See figures beginning on page 6 for LED configurations for each model.

Table 2 Indicating LEDs PWR Ethernet Link Ethernet Activity EXT LNK

GREEN Power Applied Activity Detected 10Mbps YELLOW Link Established 100Mbps OFF Power Off No Link No Activity No Link

Ethernet Activity

Ethernet Link

EXT Link Power EC-1501U-M Only

C3944M / REV 02-18-14TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981

1 Mixed PoE and Non-PoE systems can be implemented.

2 All Non-PoE systems require local power.

3 PoE powered operation requires that a PoE Camera be connected, and that the camera power requirements are understood.

4 Multiple Channel units (EC-1504x-W, EC-1508xL-R, EC-1516xL-R) require 12 VDC for proper operation. The EC-1504x-W can be used in a USRACK or EURACK with 9 VDC.

5 Single Channel unit (EC-1501x-M) require power for all Non-PoE applications. Local power can be used in PoE application to minimize PoE consumption.

6 Lower data rates generally provide longer operating distances.

7 Rack units (EC-1508xL-R, EC1516xL-R) are pre-configured for Local (LC) and have no configurable Local/Remote switch. Any unit connected to one of these rack units via an extended distance port must be configured as Remote (RM) for proper operation.

APPLICATION NOTES

TABLE 3 APPROXIMATE MAXIMUM EXTENDED DISTANCES1

Media COAX - RG59/U UTP - 4 pair

Camera Data Rate 10M 100M 10M 100M

Non-PoE Camera1 5,000 ft 1,524 m

1,800 ft 549 m

3,000 ft 914 m

2,000 ft 610 m

PoE CLASS2 Camera (6.5W)1 3,000 ft 914 m

1,800 ft 549 m

3,000 ft 914 m

2,000 ft 610 m

PoE CLASS3 Camera(13W)1 (10W in Pass-Through mode)

750 ft 228 m

750 ft 228 m

750 ft 228 m

750 ft 228 m

1 See www.pelco.com for latest spec. Distance figures are based on a 50V PSE PoE power source, and external power supplies for the extenders. Distance figures are obtained using in-house testing mirroring installations. Factors such as coaxial/copper cable quality, the number of connectors/ splices in the cable run, the use of PoE, and environmental conditions encountered within the installation may affect the actual transmission distance, and should be taken into consideration. Due to advanced negotiation signaling required in IEEE 802.3at applications, Pass-through applications are limited to IEEE 802.3af PD devices only.

PoE over extended distance is not available in 1 Pair mode. Remote PoE injection is required for this case.

INSTALLATION AND OPERATION MANUAL EC-1500 SERIES

TABLE 4 TROUBLESHOOTING GUIDE Problem Steps to Take Indicating LEDs not lighting Non-PoE: Check that power is properly applied to the unit

PoE: Check that PoE camera is connected, PoE source is enabled. No Communication Check Ethernet Link LEDs, Extended Link LEDs, All Connections, Local/Remote and 10/100 switches are set properly.

Verify that Local units are installed at the head end and that Remote units are installed in the field. Bad Video Make sure Data Rate Switch is set properly, and the extended distance is within specifications (see Table 3 Approximate

Maximum Extended Distances). PoE Not Supplied to PD Make sure camera is IEEE 802.3af rated, PoE Source switch is set properly, and the extended distance is within

specifications (see Table 3 Approximate Maximum Extended Distances). Units not reaching estimated max distances over COAX or CAT5/UTP

Check extended distance cable and connections. Try connection on a short cable to eliminate possibility of faulty cabling. Check that the extended distance wire is connected to Extended Distance Port. Verify that there is no additional equipment (e.g. surge protector) on the Extended Link. The cable should be continuous from end to end, with no active components.

TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981 C3944M / REV 02-18-14

INSTALLATION AND OPERATION MANUAL EC-1500 SERIES

SINGLE CHANNEL UTP UNITS

FOUR CHANNEL SURFACE OR RACK MOUNT UTP UNITS

MULTICHANNEL RACK UTP UNITS

C3944M / REV 02-18-14TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981

INSTALLATION AND OPERATION MANUAL EC-1500 SERIES

SINGLE CHANNEL COAX UNITS

FOUR CHANNEL SURFACE OR RACK MOUNT COAX UNITS

MULTICHANNEL RACK COAX UNITS

TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981 C3944M / REV 02-18-14

INSTALLATION AND OPERATION MANUAL EC-1500 SERIES

FIGURE A Dimensions are for a small size module

8.38cm [3.3in]

2.7cm [1.06in]

4.19cm [1.65in]

0.8cm [0.31in] 0.4cm [0.16in]

0.62cm [0.24in]

6.37cm [2.50in]

FIGURE B Dimensions are for a standard size module

13.2 (5.2)

11.9 (4.7)

15 (5.9)

7.5 (2.9) 0.63 (0.25)

2.75 (1.1)

FIGURE C Dimensions are for a EthernetConnect 19 Rack Unit

48.260cm [19.000in]

15.443cm [6.080in]

4.3688cm [1.720in]

1.905cm [0.750in]

1.905cm [0.750in]44.450cm

[17.500in]

PRODUCT DIMENSIONS The EC-1501x-M is supplied as a standalone/surface mount (small size) module. The EC-1504x-W is supplied as a standalone/surface/rack (standard size) module. The EC-1508xL-R and EC-1516xL-R are supplied as 19 wide rack units for standalone or rack installation.

INSTALLATION AND OPERATION MANUAL EC-1500 SERIES

ADDITIONAL CONSIDERATIONS Units should be installed in dry locations protected from extremes of temperature and humidity.

WARNING: Units are to be used with Listed Class 2 power supplies.

IMPORTANT SAFEGUARDS: A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment

may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum operating temperature specified in the data sheet.

B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.

PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.

Exceptions to this warranty are as noted below: Five years:

Fiber optic products Unshielded Twisted Pair (UTP) transmission products CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and

MC3651H-2X camera models Three years:

FD Series and BU Series analog camera models Fixed network cameras and network dome cameras with Sarix technology Sarix thermal imaging products (TI and ESTI Series) Fixed analog camera models (C20 Series, CCC1390H Series, C10DN Series,

and C10CH Series) EH1500 Series enclosures Spectra IV products (including Spectra IV IP) Spectra HD dome products Camclosure IS Series integrated camera systems DX Series video recorders (except DX9000 Series which is covered for a

period of one year), DVR5100 Series digital video recorders, Digital Sentry

Series hardware products, DVX Series digital video recorders, and NVR300 Series network video recorders

Endura Series distributed network-based video products Genex Series products (multiplexers, server, and keyboard) PMCL200/300/400 Series LCD monitors PMCL5xxF Series and PMCL5xxNB Series LCD monitors PMCL5xxxBL Series LED monitors

Two years: Standard varifocal, fixed focal, and motorized zoom lenses DF5/DF8 Series fixed dome products Legacy Series integrated positioning systems Spectra III, Spectra Mini, Spectra Mini IP, Esprit, ExSite, ExSite IP, and

PS20 scanners, including when used in continuous motion applications Esprit Ti and TI2500 Series thermal imaging products Esprit and WW5700 Series window wiper (excluding wiper blades) CM6700/CM6800/CM9700 Series matrix Digital Light Processing (DLP) displays (except lamp and color wheel). The

lamp and color wheel will be covered for a period of 90 days. The air filter is not covered under warranty.

Six months: All pan and tilts, scanners, or preset lenses used in continuous motion

applications (preset scan, tour, and auto scan modes) Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to a Pelco designated location. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty.

Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelcos liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental, or consequential damages (including loss of use, loss of profit, and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.

The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state.

If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information:

1. Model and serial number 2. Date of shipment, P.O. number, sales order number, or Pelco invoice number 3. Details of the defect or problem

If there is a dispute regarding the warranty of a product that does not fall under th warra ty conditions stated above, ple se include a written explanation ith the product when returned.

Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.

RETURNS To expedite parts returned for repair or credit, please call Pelco at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair) and designated return location.

All merchandise returned for credit may be subject to a 20 percent restocking and refurbishing charge.

Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid.

This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.

Revised 10-9-12

Pelco, the Pelco logo, and other trademarks associated with Pelco products referred to in this publication are trademarks of Pelco, Inc. or its affiliates. Copyright 2013, Pelco, Inc. ONVIF and the ONVIF logo are trademarks of ONVIF Inc. All other product names and services are the property of their respective companies. All rights reserved. Product specifications and availability are subject to change without notice.

PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.

Exceptions to this warranty are as noted below: Five years:

Fiber optic products Unshielded Twisted Pair (UTP) transmission products CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and

MC3651H-2X camera models Three years:

FD Series and BU Series analog camera models Fixed network cameras and network dome cameras with Sarix technology Sarix thermal imaging products (TI and ESTI Series) Fixed analog camera models (C20 Series, CCC1390H Series, C10DN Series,

and C10CH Series) EH1500 Series enclosures Spectra IV products (including Spectra IV IP) Spectra HD dome products Camclosure IS Series integrated camera systems DX Series video recorders (except DX9000 Series which is covered for a

period of one year), DVR5100 Series digital video recorders, Digital Sentry

Series hardware products, DVX Series digital video recorders, and NVR300 Series network video recorders

Endura Series distributed network-based video products Genex Series products (multiplexers, server, and keyboard) PMCL200/300/400 Series LCD monitors PMCL5xxF Series and PMCL5xxNB Series LCD monitors PMCL5xxxBL Series LED monitors

Two years: Standard varifocal, fixed focal, and motorized zoom lenses DF5/DF8 Series fixed dome products Legacy Series integrated positioning systems Spectra III, Spectra Mini, Spectra Mini IP, Esprit, ExSite, ExSite IP, and

PS20 scanners, including when used in continuous motion applications Esprit Ti and TI2500 Series thermal imaging products Esprit and WW5700 Series window wiper (excluding wiper blades) CM6700/CM6800/CM9700 Series matrix Digital Light Processing (DLP) displays (except lamp and color wheel). The

lamp and color wheel will be covered for a period of 90 days. The air filter is not covered under warranty.

Six months: All pan and tilts, scanners, or preset lenses used in continuous motion

applications (preset scan, tour, and auto scan modes) Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to a Pelco designated location. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty.

Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelcos liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental, or consequential damages (including loss of use, loss of profit, and claims of third p rties) however caused, whether by the negligence of Pelco or therwise.

The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which ar subject to variation from state to state.

If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information:

1. Model and serial number 2. Date of shipment, P.O. number, sales order number, or Pelco invoice number 3. Details of the defect or problem

If there a dispute regarding the warranty of a product that does not fall under the warranty conditions stated above, please include a written explanation with the product when returned.

Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.

RETURNS To expedite parts returned for repair or credit, please call Pelco at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair) and designated return location.

All merchandise returned for credit may be subject to a 20 percent restocking and refurbishing charge.

Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid.

This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.

Revised 10-9-12

Pelco, the Pelco logo, and other trademarks associated with Pelco products referred to in this publication are trademarks of Pelco, Inc. or its affiliates. Copyright 2013, Pelco, Inc. ONVIF and the ONVIF logo are trademarks of ONVIF Inc. All other product names and services are the property of their respective companies. All rights reserved. Product specifications and availability are subject to change without notice.

WARRANTY STATEMENT For i formation about Pelcos product warranty and thereto related informatio , refer to www.pelco.com/warranty.

INSTALLATION CONSIDERATIONS Units should be installed in dry locations protected from extremes of temperature and humidity.

CARD CAGE RACKS

CAUTION: Although the rack mount modules are hot-swappable and may be installed without turning power off to the rack, Pelco recommends that the power supply be turned off and that the rack power supply is disconnected from any power source. Note: Remove electrical connector before installing in card cage ra k.

1. Make sure that the card is oriented right side up, and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the racks connector panel. Seating may require thumb pressure on the top and bottom of the cards front panel.

CAUTION: Take care not to press on any of the LEDs.

2. Tight n the two thumb sc ws n th card until the front panel of the card is seated against th front of the rack.

Pelco, Inc. 625 W. Alluvial Ave., Fresno, CA 93711 United States USA & C

Manualsnet FAQs

If you want to find out how the EC-1508CL-R Pelco works, you can view and download the Pelco EC-1508CL-R Extender Operation Manual on the Manualsnet website.

Yes, we have the Operation Manual for Pelco EC-1508CL-R as well as other Pelco manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Operation Manual should include all the details that are needed to use a Pelco EC-1508CL-R. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Pelco EC-1508CL-R Extender Operation Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Pelco EC-1508CL-R Extender Operation Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Pelco EC-1508CL-R Extender Operation Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Pelco EC-1508CL-R Extender Operation Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Pelco EC-1508CL-R Extender Operation Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.