C3926M-A / REV 07-28-14TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981

INSTALLATION AND OPERATION MANUAL

FMCI-PF1POE and FMCI-PG1POE 10/100MBPS AND MULTI RATE ETHERNET MEDIA CONVERTERS WITH POWER OVER ETHERNET (POE)

The FMCI-PF1POE Ethernet media converter is designed to transmit and receive 10/100 Mbps data over optical fiber through user selectable FSFP modules while the FMCI-PG1POE receives 10/100/1000 Mbps electrical input and converts this to a 100 or 1000 Mbps optical output (selected by a DIP switch) and the 100/1000 Mbps optical input back to the 10/100/1000Mbps electrical output. The electrical interface will Auto-Negotiate Ethernet rates without any adjustments. These models additionally supply IEEE 802.3at (30W) compliant Power over Ethernet (PoE) to the remote end. The fiber type, distance and optics require the ordering of sold-separately interchangeable FSFP modules. These products are environmentally hardened to operate in harsh industrial environments. No electrical or optical adjustments required (Plug and Play).

Similarly, the optical data rate of 100FX or 1000FX of the FMCI-PG1POE is selected by a DIP switch. See Figure 5 on Page 4 for 100/1000FX DIP switch settings.

Bi-color (Red/Green) LED indicators are provided for rapidly confirming operating status. Please see Figure 6 on Page 5 for LED explanations.

The FMCI-PF1POE and FMCI-PG1POE operate as stand-alone modules. Please see Figures A and B on Page 6 for mounting instructions.

This manual serves the following Model Numbers: FMCI-PF1POE FMCI-PG1POE

TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981 C3926M-A / REV 07-28-14

IMPORTANT SAFETY INSTRUCTIONS

1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturers instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other.

A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.

10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the points where they exit from the apparatus.

11. Only use attachments/accessories specified by the manufacturer. 12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use

caution when moving the cart/apparatus combination to avoid injury from tip-over. 13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as

power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

14. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases shall be placed on the apparatus.

15. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. 16. Installation should be done only by qualified personnel and conform to all local codes. 17. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must

not be installed where exposed to rain and moisture. 18. Use only installation methods and materials capable of supporting four times the maximum specified load. 19. A CCC-approved power cord must be used to power this equipment when used in China. 20. CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not

perform any servicing other than that contained in the operating instructions unless you are qualified to do so.

The product and/or manual may bear the following marks: This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.

CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN.

C3926M-A / REV 07-28-14TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981

INSTALLATION AND OPERATION MANUAL FMCI-PF1POE AND FMCI-PG1POE

FIGURE 1 FMCI-PF1POE MEDIUM SIZE UNIT

FIGURE 2 FMCI-PF1POE MEDIUM SIZE UNIT REAR PANELFRONT PANEL

CAT5e/6 IEEE802.3at

(30W) PoE

BLACK WITH WHITE STRIPE

BLACK Surface Mount Power: 48VDC @ 1.25A

OPTICAL FIBER DETERMINED BY SELECTION OF FSFP MODULE

TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981 C3926M-A / REV 07-28-14

INSTALLATION AND OPERATION MANUAL FMCI-PF1POE AND FMCI-PG1POE

FIGURE 3 FMCI-PG1POE SMALL SIZE UNIT

FIGURE 4 FMCI-PG1POE SMALL SIZE UNIT REAR PANELFRONT PANEL

CAT5e/6 IEEE802.3at

(30W) PoE BLACK WITH WHITE STRIPE BLACK Surface Mount Power: 48 57 VDC @ 0.85A

OPTICAL FIBER DETERMINED BY

SELECTION OF FSFP MODULE

FIGURE 5 DIP SWITCH SETTINGS Select the Data Rate before powering on the unit. After a Data Rate change, re-cycle power to the unit.

100/1000FX DIP SWITCH POSITION RESULTING DATA RATE OFF 1000FX (requires use of Gigabit FSFP module) ON 100FX

C3926M-A / REV 07-28-14TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981

INSTALLATION AND OPERATION MANUAL FMCI-PF1POE AND FMCI-PG1POE

FIGURE 7 POSSIBLE ETHERNET CONFIGURATION Ethernet IEEE 802.3 Network Element determined by user.

FIGURE 6 LED INDICATORS

LINK COPPER POWER GREEN Solid No Activity

Blinking Activity Solid No Activity Blinking Activity

Unit powered up

YELLOW Highest Data Rate OFF No Link No Link Unit powered down

Ethernet IEEE 802.3 Network

Element

FMCI-PF1POE (Head end)

FMCI-PF1POE (Remote end)

CAT5e/6 with RJ45 Connections

100m (328ft)

CAT5e/6 with RJ45 Connections

100m (328ft)

Optical Fiber Determined By

Selection Of FSFP Module

30W Power over Ethernet

Remote Ethernet IEEE802.3at PD

TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981 C3926M-A / REV 07-28-14

MECHANICAL INSTALLATION INSTRUCTIONS

FIGURE A Dimensions are for a medium size module

INSTALLATION CONSIDERATIONS The FMCI-PF1POE and FMCI-PG1POE media converters are supplied as standalone modules. Units should be installed in dry locations protected from extremes of temperature and humidity.

CARD CAGE RACKS

CAUTION: Although the units are hot-swappable and may be installed without turning power off to the rack, the manufacturer recommends that the power supply be turned off and that the rack power supply is disconnected from any power source. Note: Remove electrical connector before installing in card cage rack.

1. Make sure that the card is oriented right side up, and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the racks connector panel. Seating may require thumb pressure on the top and bottom of the cards front panel.

CAUTION: Take care not to press on any of the LEDs.

2. Tighten the two thumb screws on the card until the front panel of the card is seated against the front of the rack.

WARNING: Unit is to be used with a Listed Class 2 power supply.

IMPORTANT SAFEGUARDS: A) Elevated Operating Ambient - If installed in a closed or multi-

unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.

B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.

FIGURE B Dimensions are for a small size module

5.000cm [1.969in]

10.000cm [3.937in]

0.600cm [0.236in]

8.291cm [3.264in]

9.490cm [3.736in]

2.697cm [1.062in]

0.396cm [0.156in]

0.795cm [0.313in]

8.38cm [3.3in]

2.7cm [1.06in]

4.19cm [1.65in]

0.8cm [0.31in] 0.4cm [0.16in]

0.62cm [0.24in]

6.37cm [0.25in]

PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.

Exceptions to this warranty are as noted below: Five years:

Fiber optic products Unshielded Twisted Pair (UTP) transmission products CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and

MC3651H-2X camera models Three years:

FD Series and BU Series analog camera models Fixed network cameras and network dome cameras with Sarix technology Sarix thermal imaging products (TI and ESTI Series) Fixed analog camera models (C20 Series, CCC1390H Series, C10DN Series,

and C10CH Series) EH1500 Series enclosures Spectra IV products (including Spectra IV IP) Spectra HD dome products Camclosure IS Series integrated camera systems DX Series video recorders (except DX9000 Series which is covered for a

period of one year), DVR5100 Series digital video recorders, Digital Sentry

Series hardware products, DVX Series digital video recorders, and NVR300 Series network video recorders

Endura Series distributed network-based video products Genex Series products (multiplexers, server, and keyboard) PMCL200/300/400 Series LCD monitors PMCL5xxF Series and PMCL5xxNB Series LCD monitors PMCL5xxxBL Series LED monitors

Two years: Standard varifocal, fixed focal, and motorized zoom lenses DF5/DF8 Series fixed dome products Legacy Series integrated positioning systems Spectra III, Spectra Mini, Spectra Mini IP, Esprit, ExSite, ExSite IP, and

PS20 scanners, including when used in continuous motion applications Esprit Ti and TI2500 Series thermal imaging products Esprit and WW5700 Series window wiper (excluding wiper blades) CM6700/CM6800/CM9700 Series matrix Digital Light Processing (DLP) displays (except lamp and color wheel). The

lamp and color wheel will be covered for a period of 90 days. The air filter is not covered under warranty.

Six months: All pan and tilts, scanners, or preset lenses used in continuous motion

applications (preset scan, tour, and auto scan modes) Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to a Pelco designated location. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty.

Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelcos liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental, or consequential damages (including loss of use, loss of profit, and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.

The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state.

If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information:

1. Model and serial number 2. Date of shipment, P.O. number, sales order number, or Pelco invoice number 3. Details of the defect or problem

If there is a dispute regarding the warranty of a product that does not fall under the warranty conditions stated above, please include a written explanation with the product when returned.

Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.

RETURNS To expedite parts returned for repair or credit, please call Pelco at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair) and designated return location.

All merchandise returned for credit may be subject to a 20 percent restocking and refurbishing charge.

Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid.

This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.

Revised 10-9-12

Pelco, the Pelco logo, and other trademarks associated with Pelco products referred to in this publication are trademarks of Pelco, Inc. or its affiliates. Copyright 2013, Pelco, Inc. ONVIF and the ONVIF logo are trademarks of ONVIF Inc. All other product names and services are the property of their respective companies. All rights reserved. Product specifications and availability are subject to change without notice.

Pelco, Inc. 625 W. Alluvial Ave., Fres

Manualsnet FAQs

If you want to find out how the C3926M-A Pelco works, you can view and download the Pelco FMCI-PG1POE C3926M-A Converter Operation Manual on the Manualsnet website.

Yes, we have the Operation Manual for Pelco C3926M-A as well as other Pelco manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Operation Manual should include all the details that are needed to use a Pelco C3926M-A. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Pelco FMCI-PG1POE C3926M-A Converter Operation Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Pelco FMCI-PG1POE C3926M-A Converter Operation Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Pelco FMCI-PG1POE C3926M-A Converter Operation Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Pelco FMCI-PG1POE C3926M-A Converter Operation Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Pelco FMCI-PG1POE C3926M-A Converter Operation Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.