Contents

Pelco MPS524DT C545M-E Controller Operation Manual PDF

1 of 8
1 of 8

Summary of Content for Pelco MPS524DT C545M-E Controller Operation Manual PDF

MPS5DT, MPS524DT, MPS524DT/220

Scanner Controls

Installation/ Operation Manual

C545M-E (2/02)

Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA www.pelco.com In North America and Canada: Tel (800) 289-9100 FAX (800) 289-9150 International Customers: Tel +1(559) 292-1981 FAX +1(559) 348-1120

2 Pelco Manual C545M-E (2/02)

LIST OF ILLUSTRATIONS

Figure Page

1 Connector Assembly ..........................................................................................5 2 Dimension Drawing ............................................................................................7

LIST OF TABLES

Table Page

A PIN Assignments ................................................................................................5

CONTENTS

Section Page

IMPORTANT SAFEGUARDS AND WARNINGS ................................................................ 3

REGULATORY NOTICES ..................................................................................................3

DESCRIPTION ..................................................................................................................4 MODELS ....................................................................................................................4 OPTIONS ...................................................................................................................4

INSTALLATION ..................................................................................................................5 CONNECTOR ASSEMBLY ........................................................................................5 COMPLETING THE INSTALLATION .........................................................................6

OPERATION ......................................................................................................................6

SPECIFICATIONS..............................................................................................................6

WARRANTY AND RETURN INFORMATION.....................................................................8

Pelco Manual C545M-E (2/02) 3

IMPORTANT SAFEGUARDS AND WARNINGS

Prior to installation and use of this product, the following WARNINGS should be observed:

1. Installation and servicing should only be done by Qualified Service Personnel and conform to all Local codes.

2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain or moisture.

3. Only use replacement parts recommended by Pelco.

4. After replacement/repair of this units electrical components, conduct a resistance measurement between line and exposed parts to verify the exposed parts and have not been connected to line circuitry.

The product and/or manual may bear the following marks:

This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.

This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.

CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

Please thoroughly familiarize yourself with the information in this manual prior to installation and operation.

REGULATORY NOTICES

This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

4 Pelco Manual C545M-E (2/02)

DESCRIPTION

The MPS5DT and MPS524DT Scanner Controls provide precise and reliable control of Pelco PS20 and PS20-24 Series Scanners. The controls can still be used with older scanner models such as Pelco PS7, PS7-24, PS30A, and PS30-24.

An additional line is available to power the PS20 scanner and camera/enclosure eliminating the need for power at the scanner location.

The front panel switches operate left and right control, and automatic scan control.

These controls can be used as desktop models or up to three units can be rack mounted in a R300 Rack Kit.

Use the RB24 Relay Box to extend the controls operating distance up to 13,000 feet using 16 AWG.

MODELS

MPS5DT Desktop control for 120 VAC scanners (PS20, PS30A) UL

MPS524DT Desktop control for 24 VAC scanners (PS7-24, PS20-24, PS30-24) UL

MPS524DT/220 Same as MPS524DT except with 230 VAC input; Desktop control for 24 VAC scanners (PS7-24, PS20-24, PS30-24) CE

OPTIONS

R300 Rack mount kit. Up to three units can be racked horizontally in a single rack kit.

RB115 Low voltage relay box for use with 24 VAC control and 120 VAC scanners. Extends operating distance (control to relay box) up to 13,000 feet using 16 AWG.

RB24 Low voltage relay box for use with 24 VAC control and 24 VAC scanners. Extends operating distance (control to relay box) up to 13,000 feet using 16 AWG.

Pelco Manual C545M-E (2/02) 5

INSTALLATION

The following items are supplied:

MPS5DT, MPS524DT, or MPS524DT/220 6-pin mating connector with pins 2 screws

CONNECTOR ASSEMBLY

The first thing you must do is assemble the mating connector. The following steps apply to all AMP style connectors regardless of pin size or pin number. Refer to Figure 1 during assembly.

1. Slide the connector clamp assembly over the conductor cable.

2. Determine the size of wire to use. Refer to the Specifications section.

3. Prepare the wires from the conductor cable as follows:

a. Strip at least 1" from the cable jacket to expose the wires. You may need to strip more from the cable jacket if you have more wires.

b. Strip 1/8" from each wire.

c. Using an AMP-style crimper, crimp the wires and their insulation to the connector pins. Refer to Detail A in Figure 1.

4. Slide the connector pins into the appropriate holes in the connector body until they snap into place. You can see the pin assignments in Table A.

Table A. PIN Assignments

PIN FUNCTION

1 Common/AC Low

2 Right

3 Left

4 Auto

5 120 VAC HI for PS20 scanner and camera power or 24 VAC HI for PS20-24 scanner and camera power

8 Chassis Ground

5. Push the connector clamp assembly towards the connector body and screw it onto the connector body. Be careful not to disturb the wires.

6. Attach the appropriate clamp with the screws provided and tighten.

OR

00103

1" 1/8"

FRONT VIEW

13

47

811

1214

Figure 1. Connector Assembly

NOTE: Pin 5 is not used with PS7 and PS30 Series Scanners.

6 Pelco Manual C545M-E (2/02)

COMPLETING THE INSTALLATION

1. Attach the mating connector to the connector on the rear of the scanner control.

2. Attach the other end of the cable to the scanner.

3. Plug the power cord on the back of the scanner control into a 120 VAC outlet (MPS5DT and MPS524DT models) or a 230 VAC outlet (MPS524DT/220 model).

OPERATION

Turn the control on and test its operation using the following procedures:

MANUAL OPERATION

Move the rocker switch to the MANUAL position.

When you move the other rocker switch to the LEFT position, the scanner pans to the left. When you move it to the RIGHT position, the scanner pans to the right.

AUTO SCAN OPERATION

Move the rocker switch to the AUTO position.

The scanner pans to the right until it reaches its limit, then pans to the left.

The scanner automatically continues right/left panning until the MANUAL switch is set again or the scanner is turned off.

SPECIFICATIONS

CONTROLS

Left/Right: Rocker switch, LEFT/RIGHT

Auto Scan: Rocker switch, AUTO/MANUAL

Power: Rocker switch, ON/OFF

Pilot Lamp: Long life neon

ELECTRICAL

Input Voltage MPS5DT, MPS24DT: 120 VAC, 50/60 Hz MPS524DT/220: 230 VAC, 50/60 Hz

Output Voltage MPS5DT: 120 VAC MPS24DT: 24 VAC MPS524DT/220: 24 VAC

Maximum Power Requirements:

PS7-24 PS30-24 PS30A PS20 PS20-24

MPS5DT 17.5 VA 30 VA

MPS524DT 8.8 VA 13 VA 20 VA

MPS524DT/220 8.8 VA 13 VA 20 VA

Fuse Protection MPS5DT: 1/4 ASB MPS524DT: 1/2 ASB MPS524DT/220: 2/10 ASB

Pelco Manual C545M-E (2/02) 7

Power Cord: Unit is supplied with grounded power cord (either U. S. Standard or Continental European Standard)

Output Connector: AMP CPC type, 14 pin (mate supplied)

Cable Requirements: 4 conductors for PS7/PS30 models and 6 for PS20/PS20-24 models

Operating Distances: The following are the recommended cable distances between the control and the listed scanners. The PS20 and PS20-24 are powered locally and do not use power from the controller.

20 AWG 18 AWG 16 AWG (0.5 mm2) (1.0 mm2) (1.5 mm2)

PS7-24 745 ft 1185 ft 1885 ft

(227 m) (361 m) (575 m)

PS30A 2265 ft 3605 ft 5720 ft

(690 m) (1098 m) (1743 m)

PS30-24 115 ft 185 ft 295 ft

(35 m) (56 m) (90 m)

PS20 2,300 ft 3,700 ft 5,900 ft (701 m) (1,127 m) (1,798 m)

PS20-24 5,600 ft 9,000 ft 14,300 ft

(1,706 m) (2,743 m) (4,368 m)

NOTE: A relay box can be used to extend the maximum operating distance (control to relay box) to 13,000 feet using 16 AWG.

GENERAL

Construction Cover: Steel, black polyester powder coat Chassis: Steel, zinc plated Panel: Aluminum, black polyester powder coat with white silkscreen

Unit Size: 5.50 (W) x 1.75 (H) x 8.90 (D) inches (13.97 x 4.45 x 22.61 cm) Refer to Figure 2.

Unit Weight MPS5DT: 3 lb (1.36 kg) MPS524DT: 4 lb (1.80 kg) MPS524DT/220: 4 lb (1.80 kg)

(Design and specifications are subject to change without notice.)

Figure 2. Dimension Drawing

8 Pelco Manual C545M-E (2/02)

REVISION HISTORY Manual # Date Comments C545M 3/85 Original version. C545M 1/90 Rev. A. Revised to include MPS524DT/220. C545M 9/90 Rev. B. Revised page 2 and Figures 2 and 6. C545M-C 10/94 Rev. C. Revised to 2-Column Format. Incorporated new wiring diagrams (Figs. 5 and 6) and updated fuse values per

ECO #94-482. Revised Figure 2 and cable assembly instructions in Section 4.1. C545M-D 6/96 Rev. D.Figures 5 and 6 revised to include new wire colors and new transformer, part #TRF22282.30.70F.

3/97 Fuse value updated in Figure 6. 5/97 Manual formatted to new style. Optional R300 Rack mount instructions removed. Figures 4 and 5 updated per ECO

#97-125 (wiring colors and connections). C545M-E 2/02 Manual formatted to new style. New scanner models added. Figures 2-4 removed.

PRODUCT WARRANTY AND RETURN INFORMATION

WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.

Exceptions to this warranty are as noted below:

Five years on FT/FR8000 Series ber optic products.

Three years on Genex Series products (multiplexers, server, and keyboard).

Three years on Camclosure and xed camera models, except the CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models, which have a ve-year warranty.

Two years on standard motorized or xed focal length lenses.

Two years on Legacy, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series xed dome products.

Two years on Spectra, Esprit, ExSite, and PS20 scanners, including when used in continuous motion applications.

Two years on Esprit and WW5700 Series window wiper (excluding wiper blades).

Eighteen months on DX Series digital video recorders, NVR300 Series network video recorders, and Endura Series distributed network-based video products.

One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.

Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes).

Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty.

Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specic use or application made of the Products. Pelcos liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss of prot and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.

The above warranty provides the Dealer with specic legal rights. The Dealer may also have additional rights, which are subject to variation from state to state.

If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information: 1. Model and serial number 2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number 3. Details of the defect or problem

If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written explanation with the product when returned.

Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.

RETURNS In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair).

All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.

Goods returned for repair or credit should be clearly identied with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate address below.

If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to: Service Department Pelco 3500 Pelco Way Clovis, CA 93612-5699

If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the following:

If the goods are to be sent by a COURIER SERVICE, send the goods to: Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA

If the goods are to be sent by a FREIGHT FORWARDER, send the goods to: Pelco c/o Expeditors 473 Eccles Avenue South San Francisco, CA 94080 USA Phone: 650-737-1700 Fax: 650-737-0933

This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European U

Manualsnet FAQs

If you want to find out how the C545M-E Pelco works, you can view and download the Pelco MPS524DT C545M-E Controller Operation Manual on the Manualsnet website.

Yes, we have the Operation Manual for Pelco C545M-E as well as other Pelco manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Operation Manual should include all the details that are needed to use a Pelco C545M-E. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Pelco MPS524DT C545M-E Controller Operation Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Pelco MPS524DT C545M-E Controller Operation Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Pelco MPS524DT C545M-E Controller Operation Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Pelco MPS524DT C545M-E Controller Operation Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Pelco MPS524DT C545M-E Controller Operation Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.