OPERATORS MANUAL

PNEUTORQUE PTM & PTME SERIES STALL TOOLS

Part Number 34321 | Issue 8 | Original Instructions (English) Norbar Torque Tools Ltd 2022

NORBAR TORQUE TOOLS LTD

Wildmere Road, Banbury, Oxfordshire, OX16 3JU

UNITED KINGDOM Tel + 44 (0)1295 270333

Email enquiry@norbar.com

For the most up-to-date version of the Operators Manual, please scan the

QR code below.

www.norbar.com

To find your local Norbar company or

distributor, please scan the QR code below.

1

CONTENTS Part Numbers Covered By This Manual 2 Safety 3 General Safety Rules 3 Projectile Hazards 3 Entanglement Hazards 3 Operating Hazards 3 Repetitive Motions Hazards 4 Accessory Hazards 4 Workplace Hazards 4 Dust and Fume Hazards 4 Noise Hazards 5 Vibration Hazards 5 Additional Safety Instructions for Pneumatic Power Tools 5 PTM Specific Safety Instructions 6 Markings on Tool 6 Introduction 7 Parts Included 7 Accessories 8 Features and Functions 9 Set Up Instructions 10 PneuTorque Hanger 10 Connecting Air Supply 10 Air Lubrication 11 Torque Reaction 11 Clockwise/Counter Clockwise Operation 14 Setting Torque to Tighten Fastener 14 Operating Instructions 15 Tightening 15 Releasing 16 Dual Trigger Tools 17 Maintenance 18 Air Lubrication 18 Gearbox 18 Silencer 18 Drive Square 19 Calibration 19 Cleaning 19 Disposal19 Specifications 20 Declaration of Conformity 22 Trouble Shooting 23 Glossary of Terms 23

2

PART NUMBERS COVERED BY THIS MANUAL This manual covers the setup and use of Norbar PneuTorque PTM and PTME stall tools.

Part Number Model Direction Maximum Torque 18100.F06 PTM-52-500-F Forward (Clockwise) only

500 Nm 18100.B06 PTM-52-500-B Bi-directional 18101.F06 PTM-52-800-F Forward (Clockwise) only

800 Nm 18101.B06 PTM-52-800-B Bi-directional 18102.F06 PTM-72-1000-F Forward (Clockwise) only

1000 Nm 18102.B06 PTM-72-1000-B Bi-directional 18103.F08 PTM-72-1350-F Forward (Clockwise) only

1350 Nm 18103.B08 PTM-72-1350-B Bi-directional 181456.F08 PTM-68-2000-F Forward (Clockwise) only

2000 Nm 181456.B08 PTM-68-2000-B Bi-directional 180296.F08 PTM-80-2700-F Forward (Clockwise) only

2700 Nm 180296.B08 PTM-80-2700-B Bi-directional 18159.F08 PTM-92-4000-F Forward (Clockwise) only

4000 Nm 18159.B08 PTM-92-4000-B Bi-directional 18159.F12 PTM-92-4000-F Forward (Clockwise) only 18159.B12 PTM-92-4000-B Bi-directional 18108.F12 PTM-119-4500-F Forward (Clockwise) only

4500 Nm 18108.B12 PTM-119-4500-B Bi-directional 18109.F12 PTM-119-6000-F Forward (Clockwise) only

6000 Nm 18109.B12 PTM-119-6000-B Bi-directional 18140.F06 PTME-72-1000-F Forward (Clockwise) only

1000 Nm 18140.B06 PTME-72-1000-B Bi-directional 18141.F08 PTME-72-2000-F Forward (Clockwise) only

2000 Nm 18141.B08 PTME-72-2000-B Bi-directional

NOTE: The main PTM and PTME models are listed above. Other PTM and PTME stall tools with

minor variances are also covered. Description of Options:

Part Number Option Description *****.F** Forward (Clockwise) only *****.B** Bi-directional (Clockwise and Counter Clockwise) *****.*06 3/4 A/F drive square size *****.*08 1 A/F drive square drive *****.*12 1 1/2 A/F drive square drive

*****.B**.DTM PneuTorque with Dual Trigger Module *****.B**.RA PneuTorque with Right Angle Gearbox

Model Option Description PTM-**-***-* PneuTorque Twin Motor

PTME-**-****-* PneuTorque Twin Motor fixed nose extension PTM*-52-****-* 52mm diameter gearbox PTM*-68-****-* 68mm diameter gearbox PTM*-72-****-* 72mm diameter gearbox PTM*-80-****-* 80mm diameter gearbox PTM*-92-****-* 92mm diameter gearbox

PTM*-119-****-* 119mm diameter gearbox PTM*-**-1000-* Maximum torque in Nm

3

SAFETY IMPORTANT: THIS OPERATORS MANUAL SHOULD BE KEPT FOR FUTURE REFERENCE. General Safety Rules: For multiple hazards, read and understand the safety instructions before installing, operating, repairing,

maintaining, changing accessories on, or working near the assembly power tool for threaded fasteners. Failure to do so can result in serious bodily injury.

Only qualified and trained operators should install, adjust or use the assembly power tool for threaded fasteners.

Do not modify this assembly power tool for threaded fasteners. Modifications can reduce the effectiveness of safety measures and increase the risks to the operator.

Do not discard the safety instructions; give them to the operator.

Do not use the assembly power tool for threaded fasteners if it has been damaged.

Tools shall be inspected periodically to verify that the ratings and markings required are legibly marked on the tool. The employer/user shall contact the manufacturer to obtain replacement marking labels when necessary.

Projectile Hazards: Failure of the workpiece, of accessories or even of the tool itself can generate high-velocity projectiles.

Always wear impact-resistant eye protection during the operation of the assembly power tool for threaded fasteners. The grade of protection required should be assessed for each use.

Ensure that the workpiece is securely fixed.

Entanglement Hazards: Entanglement hazards can result in choking, scalping and/or lacerations if loose clothing, personal

jewellery, neckware, hair or gloves are not kept away from the tool and accessories.

Inappropriate gloves can become entangled with the rotating drive, causing severed or broken fingers.

Rotating drive sockets and drive extensions can easily entangle rubber-coated or metal-reinforced gloves.

Do not wear loose-fitting gloves or gloves with cut or frayed fingers.

Never hold the drive, socket or drive extension.

Keep hands away from rotating drives.

Operating Hazards: The use of the tool can expose the operator's hands to hazards including crushing, impacts, cuts and

abrasions and heat. Wear suitable gloves to protect hands.

These tools require the use of a suitable reaction which presents a crushing hazard. Ensure to follow the set up instructions in this manual.

Operators and maintenance personnel shall be physically able to handle the bulk, weight and power of the tool.

Hold the tool correctly; be ready to counteract normal or sudden movements and have both hands available.

4

Maintain a balanced body position and secure footing.

Release the trigger in the case of an interruption of the energy supply.

Use only lubricants recommended by the manufacturer.

Do not use in confined spaces and beware of crushing hands between tool and workpiece.

Repetitive Motions Hazards: When using a power tool for threaded fasteners, the operator can experience discomfort in the hands,

arms, shoulders, neck, or other parts of the body.

While using an assembly power tool for threaded fasteners, the operator should adopt a comfortable posture whilst maintaining secure footing and avoiding awkward or off-balanced postures. The operator should change posture during extended tasks, which can help avoid discomfort and fatigue.

If the operator experiences symptoms such as persistent or recurring discomfort, pain, throbbing, aching, tingling, numbness, burning sensations or stiffness, these warning signs should not be ignored. The operator should tell the employer and consult a qualified health professional.

Accessory Hazards: Disconnect the assembly power tool for threaded fasteners from the energy supply before changing the

tool or accessory.

Use only sizes and types of accessories and consumables that are recommended by the assembly power tool for threaded fasteners manufacturer; do not use other types or sizes of accessories and consumables.

Workplace Hazards: Slips, trips and falls are major causes of workplace injury. Be aware of slippery surfaces caused by the

use of the tool and also of trip hazards caused by the air line or hydraulic hose.

Proceed with care in unfamiliar surroundings. Hidden hazards, such as electricity or other utility lines, can exist.

The assembly power tool for threaded fasteners is not intended for use in potentially explosive atmospheres and is not insulated against coming into contact with electrical power.

Make sure there are no electrical cables, gas pipes, etc., that can cause a hazard if damaged by use of the tool.

Dust and Fume Hazards: Dust and fumes generated when using assembly power tools for threaded fasteners can cause ill health

(for example, cancer, birth defects, asthma and/or dermatitis); risk assessment and implementation of appropriate controls for these hazards are essential.

Risk assessment should include dust created by the use of the tool and the potential for disturbing existing dust.

Direct the exhaust so as to minimize disturbance of dust in a dust-filled environment.

Where dust or fumes are created, the priority shall be to control them at the point of emission.

All integral features or accessories for the collection, extraction or suppression of airborne dust or fumes should be correctly used and maintained in accordance with the manufacturer's instructions.

Use respiratory protection in accordance with employer's instructions and as required by occupational health and safety regulations.

5

Noise Hazards: Unprotected exposure to high noise levels can cause permanent, disabling, hearing loss and other

problems, such as tinnitus (ringing, buzzing, whistling or humming in the ears). Therefore a risk assessment and implementation of appropriate controls for these hazards are essential.

Appropriate controls to reduce the risk may include actions such as damping materials to prevent workpieces from ringing.

Use hearing protection in accordance with employer's instructions and as required by occupational health and safety regulations.

Operate and maintain the assembly power tool for threaded fasteners as recommended in the instruction handbook, to prevent an unnecessary increase in noise levels.

If the assembly power tool for threaded fasteners has a silencer, always ensure it is in place and in good working order when the assembly power tool for threaded fasteners is operating.

Select, maintain and replace the consumable/tool as recommended in the instruction handbook, to prevent an unnecessary increase in noise.

Vibration Hazards: Exposure to vibration can cause disabling damage to the nerves and blood supply of the hands and

arms.

Wear warm clothing when working in cold conditions and keep your hands warm and dry.

If you experience numbness, tingling, pain or whitening of the skin in your fingers or hands, stop using the assembly power tool for threaded fasteners, tell your employer and consult a physician.

Operate and maintain the assembly power tool for threaded fasteners as recommended in the instruction handbook, to prevent an unnecessary increase in vibration levels.

Do not use worn or ill-fitting sockets or extensions, as this is likely to cause an increase in vibration.

Select, maintain and replace the consumable/tool as recommended in the instruction handbook, to prevent an unnecessary increase in vibration levels.

Support the weight of the tool in a stand, tensioner or balancer, if possible.

Hold the tool with a light but safe grip, taking account of the required hand reaction forces, because the risk from vibration is generally greater when the grip force is higher.

Additional Safety Instructions for Pneumatic Power Tools: Air under pressure can cause severe injury:

o Always shut off air supply, drain hose of air pressure and disconnect tool from air supply when not in use, before changing accessories or when making repairs;

o Never direct air at yourself or anyone else.

Whipping hoses can cause severe injury. Always check for damaged or loose hoses and fittings.

Cold air shall be directed away from the hands.

Air lines with safe disconnect couplings, as supplied, are recommended. Whenever universal twist couplings (claw couplings) are used, lock pins shall be installed and whipcheck safety cables shall be used to safeguard against possible hose-to-tool and hose-to-hose connection failure.

Do not exceed the maximum air pressure stated on the tool.

6

For torque-control and continuous-rotation tools, the air pressure has a safety critical effect on performance. Therefore, requirements for length and diameter of the hose shall be specified.

Never carry an air tool by the hose.

PTM Specific Safety Instructions: This tool is intended for use with threaded fasteners. Other uses within the limits of the tool may be

appropriate. Please contact Norbar for guidance.

The user (or the users employer) shall assess the specific risks that can be present as a result of each use. This Operators Manual contains sufficient information for the end user to be able to perform an initial risk assessment.

Unexpected direction of drive square movement can cause a hazardous situation.

Isolate the tool from all energy sources before changing or adjusting the drive square or socket.

Markings on Tool

Pictograms on Tool Meaning

Read and understand Operators Manual.

Unexpected tool movement due to reaction forces or breakage of drive square or reaction bar may cause injuries. There is a risk of crushing between the reaction bar and work piece. Keep hands away from reaction bar. Keep hands away from tool output.

7

INTRODUCTION The PneuTorque PTM & PTME tools are air driven power tools designed for applying torque to threaded fasteners. There are models to cover torque capacities of 500 Nm to 2000 Nm. The tools use an external air pressure regulator (included in a Lubro Control Unit) to set the air pressure that controls the stall torque. Parts Included

Description Part Number

PTM-52 PTM-68 PTM-72 PTM-80 PTM-92 PTM-119 PTME-72

Visual Difference

PneuTorque

Power Tool 18100.** 18101.** 181456.***

18102.** 18103.** 18104.**

180296.** 18159.** 18108.** 18109.**

18140.** 18141.** 18149.**

Cranked Reaction Bar 18646 19611 18494 19289 18936 18961 -

Reaction Bar Retaining

Circlip 26588 265417 26486 26486 26486 26482 -

Hanger 18747 18747 18747 18971 18971 18971 18747

Operators Manual (with air pressure

graph & language USB

[if required])

34321 34321 34321 34321 34321 34321 34321

8

Accessories

Description Part Number PTM-52 PTM-68 PTM-72 PTM-80 PTM-92 PTM-119 PTME-72

Air Coupling Socket for Hose 28933 28933 28933 28933 28933 28933 28933

Lubro Control Unit 16074 16074 16074 16074 16074 16074 16074 3/4" Drive Square

(fixing screw) 18544

(25351.30) - 18779 (25352.45) - - - -

1 Drive Square (fixing screw)

18545 (25351.30)

19431 (25352.45)

18492 (25352.45)

19431 (25352.40)

18934 (25352.60) - -

1 1/2 Drive Square

(fixing screw) - - - - 18935

(25352.60) 18959

(25352.80) -

3/4" Drive Shaft (fixing pin) - - - - - - 77112.2

(26287) 1 Drive Shaft

(fixing pin) - - - - - 18802 (26287)

Reaction Plate [NOTE 1]

18298 - 18298 - - - -

Reaction Adaptor [NOTE 1]

18558 - 18290 - - - -

Single-Sided Reaction Plate

18576 - 18292 - 18979 16687 -

Double-Sided Reaction Plate

18590 - 18293 - 18980 18981 -

Silencer 18591 18591 18591 18591 18591 18591 18591 6 Blade Nose

Extension (3/4)

18594.006 - (1) 18755.006 - - - -

9 Blade Nose Extension

(3/4) 18594.009 - (1)

18755.009 - - - -

12 Blade Nose Extension

(3/4) 18594.012 - (1)

18755.012 - - - -

9 Nose Extension for Truck & Bus

Wheels - -

(3/4) 19087.009

(1) 19089.009

- - - -

12 Nose Extension for Truck & Bus

Wheels

- -

(3/4) 19087.012

(1) 19089.012

- - - -

9

Description Part Number PTM-52 PTM-68 PTM-72 PTM-80 PTM-92 PTM-119 PTME-72

Dual Trigger Module

19286 19286 19286 19286 19286 19286 19286

Lifting Handle

- - 19363 19448 19363 19363 19363

NOTE 1: Requires both the Reaction Bar and Reaction Adaptor to be used together. FEATURES AND FUNCTIONS Twin Motor The tools use two motors; one to quickly run-down the fastener and the other to achieve final torque. Trigger The trigger controls the flow of air. The more the trigger is pressed the more air flows into the tool. This allows for slow positioning of socket and reaction bar. Once positioning is complete, the trigger must be fully pressed for correct torque application. Clockwise/Counter-Clockwise Selector Tools fitted with this option can be used for tightening counter-clockwise threaded fasteners and for releasing clockwise threaded fasteners. Reaction Bar The reaction bar ensures all reaction forces are contained, so that torque reaction is not passed back to the operator. Several reaction bar styles are available, including the PTME / Nose Extension reaction where tool access is restricted including applications on wheel nuts on heavy vehicles. Non-Impacting Low vibration levels make these tools comfortable and safe for the operator to use. In addition there is less damage to the tool, socket and threaded assembly. Replaceable Drive Square To avoid internal damage to the tool (especially due to torque overload), the output drive square has been designed to shear first. PneuTorque tools are fitted with a drive square that can easily be replaced; alternative drive square sizes are also available.

10

Hanger The hanger can be used to suspend the PneuTorque from a balancer. Quick Tool Coupling Air couplings supplied to allow quick tool connection and disconnection from the air hose. SET UP INSTRUCTIONS The PneuTorque set up covers the following items: 1. PneuTorque Hanger

2. Connecting Air Supply

3. Air Lubrication

4. Torque Reaction

5. Clockwise / Counter-Clockwise Operation

6. Setting torque to tighten fastener Please complete the set up in the order shown. PneuTorque Hanger The PneuTorque hanger (Figure 1-E) is designed to be used with a suitable balancer to provided comfortable tool use. If not required the hanger can be removed. Connecting Air Supply

WARNING: TO AVOID HAZARD FROM WHIPPING AIR HOSES MAKE ALL CONNECTIONS TO THE TOOL BEFORE TURNING ON THE AIR SUPPLY.

Make sure all hoses are clean, in good condition and free from dirt / water. Connect the tool air inlet hose (Figure 1-A) to the outlet side of the lubro control unit (Figure 1-B) (not supplied), observing air flow direction arrows. TIP: On tools supplied with quick air couplings, fit the coupling plug

to the tool inlet and the coupling socket to air hose. To connect, push couplings together. To disconnect, pull back lock on socket coupling.

Connect the inlet side of the lubro control unit (Figure 1-B) to the air supply (Figure 1-C) using a minimum hose size of 1/2 bore (12mm). Avoid using 1/2 bore hoses of longer than 5 meters from the supply to the pressure regulator unit as this will reduce the performance of the tool.

11

Turn on air supply and check for air leaks.

FIGURE 1 Connections

Air Lubrication The tool must be used with oil lubrication in the supplied air. This is achieved by using a Lubro Control Unit (not supplied). Set the air lubrication:

a. Fill Lubro Control Unit with hydraulic oil (Fuchs Silkair VG22, Shell Tellus S2 VX15 or equivalent good quality hydraulic oil).

b. Ensure the tool drive is free to rotate.

c. Run the tool by pressing the trigger.

d. Adjust Lubro Control Unit to supply 6 drops of oil per minute.

e. Release trigger. See Lubro Control Unit Operators Manual for more details. Torque Reaction The reaction bar ensures all reaction forces are contained, so torque reaction is not passed back to the operator. Several reaction bar styles are available. Fit reaction bar as detailed below:

Tool Type Reaction Bar Type Fitting Instructions

PTM

Cranked reaction bar (standard) Fit reaction bar / plate (Figure 1-D) over the drive square to engage reaction splines

Secure with circlip supplied Single sided reaction plate (option) Double sided reaction plate (option)

Nose Extension (option)

Fit as instructions supplied with nose extension

PTME Nose Extension (standard) Factory fitted, not removable

C

B

A D

E

12

It is essential the reaction bar rests squarely against a solid object or surface adjacent to the fastener to be tightened. The contact area must be within the shaded area of Figure 2, with the contact area as large as possible.

FIGURE 2 Safe Reaction Window

WARNING: CARE MUST BE TAKEN TO ENSURE THAT THE REACTION BAR IS ONLY USED WITHIN THE LIMITATIONS SHOWN IN FIGURE 2.

For special applications or where extra deep sockets must be used the standard bar may be extended but only within the limitations shown on Figure 2. Alternative reaction bars are available, see page 5.

WARNING: FAILURE TO OBSERVE THE LIMITATIONS SHOWN IN FIGURE 2 WHEN MODIFYING STANDARD REACTION BARS MAY RESULT IN PREMATURE WEAR OR DAMAGE TO THE TOOL.

Standard drive square extensions MUST NOT be used as these will cause serious damage to the tool output drive. A range of nose extensions is available for applications where access is restricted. These are designed to support the final drive correctly. The dimensions of the standard reaction bars is shown in the following table:

Reaction Bars (Standard) Tool L A B W SQ

PTM-52 60 131 71 35 3/4

PTM-68 74 165 120 30 1

PTM-72 75 165 91 48 1

PTM-80 75.5 167 115 30 1

PTM-92 98.5 205 115 50 1 1 1/2"

PTM-119 127 199 65 55 1 1/2"

Extra Length Socket Standard Length Socket

Torque Reaction should be taken in the shaded areas only

13

Reaction Bars (PTME) Tool L A B W SQ

PTME-72 (1000 Nm) 80.5 110 63 12 3/4"

PTME-72 (2000 Nm) 51.5 110 62 16 1

When the PneuTorque is in operation the reaction bar rotates in the opposite direction to the output drive square and must be allowed to rest squarely against a solid object or surface adjacent to the fastener to be tightened. (See Figure 3).

PneuTorque

Type

Torque Reaction

Clockwise Counter-Clockwise (Bi-Directional Tools Only)

Example of PTM tool

FIGURE 3(a)

FIGURE 3(b)

Example of PTM tool with

nose extension for truck & bus wheel option

FIGURE 3(c)

FIGURE 3(d)

WARNING: ALWAYS KEEP HANDS CLEAR OF THE REACTION BAR WHEN THE TOOL IS IN USE OR SERIOUS INJURY MAY RESULT.

14

Clockwise/Counter-Clockwise Operation Set clockwise / counter-clockwise as required. NOTE: This setting only applies to bi-directional tools.

WARNING: FAILURE TO FULLY ENGAGE THE CLOCKWISE/COUNTER-CLOCKWISE OPERATION SELECTOR WILL RESULT IN DAMAGE TO THIS PART OF THE GEARBOX.

Setting Torque to Tighten Fastener The torque created by the PneuTorque depends on the air pressure setting. All tools are supplied with an Air Pressure Graph that gives the air pressure required to produce the correct torque output. Set the torque output as follows:- 1. Use the Air Pressure Graph (supplied)

to find the air pressure to achieve the required torque.

2. With the tool running, adjust the Lubro Control Unit until the correct air pressure is shown on the gauge. IMPORTANT: THE WRENCH MUST BE FREE RUNNING WHILE ADJUSTING THE AIR PRESSURE

TO GIVE THE CORRECT SETTING. IMPORTANT: CHECK THAT THE LUBRO CONTROL UNIT IS SUPPLYING APPROXIMATELY SIX

DROPS OF OIL PER MINUTE WHILE THE TOOL IS FREE RUNNING.

FIGURE 4(a) Clockwise (Arrow towards drive square)

FIGURE 4(b) Counter - Clockwise (Arrow away from drive square)

15

OPERATING INSTRUCTIONS

WARNING: KEEP HANDS CLEAR OF THE REACTION BAR.

WARNING: WHEN USING THIS TOOL IT MUST BE SUPPORTED AT ALL TIMES IN ORDER TO PREVENT UNEXPECTED RELEASE IN THE EVENT OF FASTENER OR COMPONENT FAILURE.

Tightening 1. Fit PneuTorque with the correct size impact or high quality socket to suit fastener. TIP: For added safety it is recommended to secure the socket to the square drive.

This is often achieved using a pin and O ring, see socket manufacturer for guidance.

2. Ensure the Clockwise/Counter-clockwise selector is correctly set (if fitted).

3. Rotate the handle into a convenient position relative to the reaction bar. Fit the tool onto the fastener to be tightened with the reaction bar adjacent to the reaction point. See Figure 5.

4. Adopt a suitable posture to counteract normal or unexpected movement of the tool due to reaction forces.

5. Squeeze the trigger partially to bring the reaction bar into contact with the reaction point.

6. Fully press trigger and keep fully pressed until tool stalls then release trigger. If the trigger is not fully pressed full torque will not be applied to the fastener.

7. Remove the tool from the fastener.

FIGURE 5

16

Releasing NOTE: Only for bi-directional tools.

1. Fit the PneuTorque with the correct size impact or high quality socket to suit the fastener to be released.

TIP: For added safety it is recommended to secure the socket to the square drive.

This is often achieved using a pin and O ring, see socket manufacturer for guidance. 2. Ensure the clockwise/counter-clockwise selector is correctly set.

3. Rotate the handle into a convenient position relative to the reaction bar. Fit the tool onto the fastener to be released with the reaction bar adjacent to the reaction point. See Figure 6.

4. Adopt a suitable posture to counteract normal or unexpected movement of the tool due to reaction forces.

5. Squeeze the trigger partially to bring the reaction bar into contact with the reaction point.

6. Fully press trigger and keep fully pressed until threaded fastener releases. TIP: If unable to release the fastener, increase the air pressure to the tool. Do not exceed the

maximum air pressure for the tool.

WARNING: EXCEEDING THE MAXIMUM AIR PRESSURE WILL CAUSE OVERLOADING AND MAY LEAD TO SERIOUS DAMAGE.

WARNING: CHANGING THE AIR PRESSURE AFTER SETTING THE PRESSURE

REGULATOR WILL CHANGE THE STALL TORQUE VALUE.

FIGURE 6

17

Dual Trigger Tools Tools purchased with a Dual Trigger Module (DTM) pre-fitted are identified with the part number suffix .DTM Tools purchased with a DTM pre-fitted are calibrated at Norbar with the DTM in place. This is because the DTM itself creates a pressure drop which would alter any previously determined calibration data.

WARNING: IF A TOOL IS PURCHASED WITH A DTM FITTED (AS A DTM TOOL) AND THE USER WANTS TO REMOVE THE MODULE AND USE THE TOOL WITHOUT IT, A NEW CALIBRATION IS REQUIRED. IN THIS SCENARIO CONTACT NORBAR OR YOUR NORBAR DISTRIBUTOR.

With the DTM fitted the tool will not operate unless both the trigger on the DTM and the tool trigger are pressed simultaneously. As with the tool trigger, the DTM trigger must be fully pressed so as not to affect the air flow, pressure, and ultimately the torque output.

FIGURE 7 Dual Trigger Module

18

FIGURE 8 Silencer Replacement

MAINTENANCE For optimum performance and safety, regular tool maintenance is required. The user maintenance is limited to the replacement of the drive square and the silencer. Any other maintenance or repairs should be carried out by Norbar or a Norbar distributor. Maintenance intervals will depend on the tool usage and the environment in which it is being used. The maximum recommended maintenance and recalibration interval is 12 months. TIP: Steps the user can take to reduce the amount of maintenance required include:

1. Use the tool in a clean environment. 2. Use an air compressor fitted with a dryer. 3. Ensure the Lubro Control Unit has sufficient hydraulic oil. 4. Ensure the Lubro Control Unit delivers hydraulic oil at the correct rate. 5. Ensure the Lubro Control Unit is regularly maintained, see product manual. 6. Maintain the correct torque reaction.

Air Lubrication Add Fuchs Silkair VG22, Shell Tellus S2 VX15 or equivalent good quality hydraulic oil to the Lubro Control Unit. Gearbox Under normal operating conditions it is not necessary to re-grease the gearbox. The gearbox contains Lubcon Turmogrease Li 802 EP or equivalent good quality grease. Silencer The silencer (part number 18591) must be changed every 12 months. This may be more frequent for high tool usage or dirty environments. TIP: Change silencer with tool upside down, as shown, to ensure internal parts (spring and valve)

are kept in place. 1. Remove M4 screw (A) (part number 25381.10) using a 2.5mm hexagon key. 2. Remove pin (B) (part number 26284) using a pin punch. 3. Pull out air inlet tube (D) with base plate & silencer. 4. Remove silencer (E) from air inlet tube. 5. Fit new silencer (part number 18591) over air inlet tube. 6. Fit air inlet tube assembly (C, D & E) into handle against spring resistance. 7. Fit pin (B) with a hammer. 8. Fit screw (A) and torque to 0.5 Nm. Do not over tighten this screw as it is likely to break the base plate

moulding. TIP: When refitting air inlet tube assembly into handle care should be taken to ensure correct

alignment between air inlet tube and spring. It may be easier to fit the spring into air inlet tube first and secure with a small amount of grease.

C

B A

D

E

19

Drive Square To avoid internal damage (especially due to torque overload), the output drive square has been designed to shear first. This saves major internal damage and allows easy square removal. For drive square part numbers see page 5. To replace drive square:

1. Remove the air supply. 2. Support tool in a horizontal position. 3. Remove the screw or spring pin, then remove drive square. If the square has sheared it may be necessary to use pliers to remove the broken parts. 4. Fit new drive square. 5. Fit new screw and tighten between 4 Nm to 5 Nm (for PTM52) or 8 Nm to 9 Nm (for

PTM68/72/80/92/119) or insert new spring pin. 6. Connect air supply. TIP: If the drive square fails continually then seek advice from Norbar or a Norbar distributor. Calibration To maintain the PneuTorque accuracy it is recommended the tool is recalibrated at least every 12 months. Contact Norbar or a Norbar distributor for more information. Cleaning Keep the tool in a clean condition to aid safety. Do not use abrasives or solvent based cleaners. Disposal Recycling Considerations:

Component Material Handle Aluminium Case / Steel Internals

Gearbox (Clockwise / Counter-Clockwise) Aluminium Case / Steel Internals Gearbox (52mm / 68mm / 72mm /

80mm / 92mm / 119mm) Steel with Nickel Plated Case / Steel Internals

Reaction Bar PTM-52 is Steel / PTM-72 is Aluminium

FIGURE 9 Square Drive Replacement

20

SPECIFICATIONS

Part Number Torque Tool Speed Minimum Maximum 18100.*** 100 Nm (74 lbfft) 500 Nm (370 lbfft) 224 rev/min 18101.*** 160 Nm (118 lbfft) 800 Nm (590 lbfft) 148 rev/min

18102.*** / 18140.*** / 18162.*** 200 Nm (147 lbfft) 1000 Nm (738 lbfft) 122 rev/min

18103.*** / 18163.*** 270 Nm (200 lbfft) 1350 Nm (1000 lbfft) 86 rev/min 181456.*** / 18141.** 400 Nm (295 lbfft) 2000 Nm (1475 lbfft) 58 rev/min

180296.*** 540 Nm (400 lbfft) 2700 Nm (2000 lbfft) 40 rev/min 18159.*** 800 Nm (590 lbfft) 4000 Nm (2950 lbfft) 32 rev/min 18108.*** 900 Nm (660 lbfft) 4500 Nm (3300 lbfft) 23 rev/min 18109.*** 1200 Nm (885 lbfft) 6000 Nm (4425 lbfft) 15.5 rev/min

Part Number

Dimensions (mm) Tool Weight (kg) Reaction Weight

(kg) H W R L *****.F** *****.B** *****.F** *****.B**

18100.*** 318 82 60 320 369 3.8 4.1 0.85 18101.*** 318 82 60 320 369 3.8 4.1 0.85 18102.*** 318 85.7 75 361 410 5.8 6.1 0.7 18103.*** 318 85.7 75 361 410 5.8 6.1 0.7

181456.*** 318 85.7 74.5 357 406 5.0 5.3 1.1 180296.*** 318 82 79.5 366 415 7.2 7.5 1.4 18159.*** 318 92 98.5 432 481 8.2 8.5 1.35 18108.*** 318 119 127 484 533 13 13.3 2.1 18109.*** 318 119 127 484 533 13 13.3 2.1 18140.*** 318 82 51.5 435 484 6.9 7.2 - 18141.*** 318 82 51.5 457 506 7.4 7.7 - 18162.*** 318 82 82 - 532 - 9.4 - 18163.*** 318 82 82 - 532 - 9.5 -

FIGURE 10 Tool Dimensions

21

Repeatability: 5% Air Supply: Maximum pressure 6.3 bar (For maximum output speed). Lubrication: Fuchs Silkair VG22 or Shell Tellus S2 VX15 recommended for the Lubro Control

Unit. Temperature Range: 0C to +50C (operating). -20C to +60C (storage). Operating Humidity: 85% Relative Humidity @30C maximum. Handle Vibration: < 2.5m/s measured in accordance with ISO 28927-2. Measured tool vibration (ah) = 1.79 m/s with uncertainty (K) = 0.34 m/s Sound Pressure Level: The sound pressure level is 84 dB(A) uncertainty K = 3dB, measured in

accordance with BS EN ISO 11148-6 Environment: Store in a clean & dry environment. Machinery Directive: In conformance with: BSEN 792-6:2000 Hand-held non-electric power tools. Safety requirements. Assembly power tools for threaded fasteners.

Due to continuous improvement all specifications are subject to change without prior notice. NOTE: If equipment is used in a manner not specified by the manufacturer, the protection provided

by the equipment could be impaired.

22

DECLARATION OF CONFORMITY

UK Declaration of Conformity (No 0022V2)

The object of the declaration: PneuTorque PTM & PTME Series Stall Tools. Model Name (Part Number): PTM-52-****-* (18100.***, 18101.*** & 77383), PTM-68-****-* (181456.***), PTM-72-****-* (18102.***, 18103.***, 18104.*** & 77257), PTM-80-****-* (180296.***), PTM-92-****-* (18159.***), PTM-119-****-* (18108.*** & 18109.***) & PTME-72-****-* (18140.***, 18141.*** & 18149.***) Serial Number All. The object of the declaration described above is in conformity with the relevant UK statutory requirements: Supply of Machinery (Safety) Regulations 2008 The object of the declaration described above has been designed to comply with the following standards: BS EN ISO 11148-6:2012 The basis on which conformity is being declared: This declaration of conformity is issued under the sole responsibility of the manufacturer. The technical documentation required to demonstrate that the products meet the requirements of the above legislation has been compiled by the signatory below and is available for inspection by the relevant enforcement authorities. The UKCA mark was first applied in: 2021. Signed for and on behalf of Norbar Torque Tools Ltd.

Signed: Full Name: Trevor Mark Lester B.Eng. Date: 8 February 2022 Authority: Compliance Engineer Place: Norbar Torque Tools Ltd., Wildmere Road, Banbury, Oxfordshire. OX16 3JU

EU Declaration of Conformity (No 0022V3)

The object of the declaration: PneuTorque PTM & PTME Series Stall Tools. Model Name (Part Number): PTM-52-****-* (18100.***, 18101.*** & 77383) , PTM-68-****-* (181456.***), PTM-72-****-* (18102.***, 18103.***, 18104.*** & 77257), PTM-80-****-* (180296.***), PTM-92-****-* (18159.***), PTM-119-****-* (18108.*** & 18109.***) & PTME-72-****-* (18140.***, 18141.*** & 18149.***) Serial Number All. The object of the declaration described above is in conformity with the relevant union harmonisation legislation: Directive 2006/42/EC on Machinery Directive. The object of the declaration described above has been designed to comply with the following standards: EN ISO 11148-6:2012 The basis on which conformity is being declared: This declaration of conformity is issued under the sole responsibility of the manufacturer. The technical documentation required to demonstrate that the products meet the requirements of the above Directives has been compiled by the signatory below and is available for inspection by the relevant enforcement authorities. The CE mark was first applied in: 2007. The authorised representative to compile the technical file within the European Union (EU) is: Francesco Frezza Snap-On Equipment S.r.l. Via Prov. Carpi, 33 42015 Correggio RE Italy Signed for and on behalf of Norbar Torque Tools Ltd.

Signed: Full Name: Trevor Mark Lester B.Eng. Date: 8 February 2022 Authority: Compliance Engineer Place: Norbar Torque Tools Ltd., Wildmere Road, Banbury, Oxfordshire. OX16 3JU

23

TROUBLE SHOOTING The following is only a guide, for more complex faults please contact Norbar or a Norbar distributor.

Problem Likely Solutions

Tool output does not rotate when trigger pressed

Check air supply is functioning and connected Check air pressure setting (at least 1 bar) Check correct setting of direction knob Check both triggers are fully pressed for Double Trigger versions. Output drive square sheared, needs replacing Gear train or air motor is damaged

Drive square is sheared See maintenance section to replace drive square

Tool does not stall Fastener sheared or thread stripped Gear train or air motor is damaged

GLOSSARY OF TERMS

Word or Term Meaning A/F Across Flats

Air Pressure Graph Graph supplied with all stall tools to show the air pressure setting to produce required torque

Bi-directional Tool capable of Clockwise and Counter-clockwise square rotation

Calibration Device Torque measurement system to display peak torque using a joint simulator or test fastener

Fastener Bolt or stud to be tightened

Lubro Control Unit Unit to provide filtering and lubrication along with pressure regulation. Not supplied with tool

Nose Extension A reaction type used where tool access is restricted, typical examples on wheel nuts on heavy vehicles. Available as an option for PTM tools or integral for PTME tools

PneuTorque Product name

PTM PneuTorque Twin Motor

PTME PneuTorque Twin Motor with fixed nose extension

Reaction Bar Item to counteract applied torque. Also called reaction plate

Stall Tool Tool will stall due to air pressure set.

24

NOTES

OPERATORS MANUAL

PNEUTORQUE PTM & PTME SERIES STALL TOOLS

Part Number 34321 | Issue 8 | Original Instructions (English) Norbar Torque Tools Ltd 2022

NORBAR TORQUE TOOLS LTD

Wildmere Road, Banbury, Oxfordshire, OX16 3JU

UNITED KINGDOM Tel + 44 (0)1295 270333

Email enquiry@norbar.com

For the most up-to-date version of the Operators Manual, please scan the

QR code below.

www.no

Manualsnet FAQs

If you want to find out how the PNEUTORQUE PTM & PTME Series Norbar works, you can view and download the Norbar PNEUTORQUE PTM & PTME Series 34321 Stall Tool Operator's Manual on the Manualsnet website.

Yes, we have the Operator's Manual for Norbar PNEUTORQUE PTM & PTME Series as well as other Norbar manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Operator's Manual should include all the details that are needed to use a Norbar PNEUTORQUE PTM & PTME Series. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Norbar PNEUTORQUE PTM & PTME Series 34321 Stall Tool Operator's Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Norbar PNEUTORQUE PTM & PTME Series 34321 Stall Tool Operator's Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Norbar PNEUTORQUE PTM & PTME Series 34321 Stall Tool Operator's Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Norbar PNEUTORQUE PTM & PTME Series 34321 Stall Tool Operator's Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Norbar PNEUTORQUE PTM & PTME Series 34321 Stall Tool Operator's Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.