User's Manual

GT16M-ROUT

Thank you for choosing Mitsubishi Electric Graphic Operation Terminal (GOT).

2008 MITSUBISHI ELECTRIC CORPORATION

GT16 RGB Output Unit

Prior to use, please read both this manual and detailed manual thoroughly to fully understand the product.

MODEL GT16M-ROUT-U

MODEL CODE

1D7M86

IB(NA)-0800430-I(1806)MEE

SAFETY PRECAUTIONS (Always read these precautions before using this equipment.)

Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly. The precautions given in this manual are concerned with this prod- uct. In this manual, the safety precautions are ranked as "WARNING" and "CAUTION".

Note that the CAUTION level may lead to a serious accident according to the circumstances. Always follow the precautions of both levels because they are import- ant to personal safety. Please save this manual to make it accessible when required and always forward it to the end user.

Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.

Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.

WARNING

CAUTION

[DESIGN PRECAUTIONS]

[INSTALLATION PRECAUTIONS]

[WIRING PRECAUTIONS]

[STARTUP AND MAINTENANCE PRECAUTIONS]

Do not bunch the control wires or communication cables with the main circuit or power wires, or lay them close to each other. As a guide, separate the lines by a distance of at least 100mm (3.94 inches) otherwise malfunctions may occur due to noise.

Be sure to shut off all phases of the external power supply used by the system before mounting or removing this unit to/from the GOT. Not doing so can cause a unit failure or malfunction.

Before connecting the Bus connection cable to this unit, always shut off GOT power and PLC CPU power externally in all phases.Not doing so can cause a malfunction.

Use this unit in the environment that satisfies the general specifications described in the User's Manual for the GOT used. Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration.

Do not drop the unit or subject it to string shock. A unit damage may result.

When installing this unit to the GOT, fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range. Undertightening can cause a drop, failure or malfunction. Overtightening can cause a drop, failure or malfunction due to screw or unit damage.

Be sure to shut off all phases of the external power supply used by the system before wiring. Failure to do so may result in an electric shock, product damage or malfunctions.

Exercise care to avoid foreign matter such as chips and wire offcuts entering the unit. Not doing so can cause a fire, failure or malfunction.

Make sure to securely connect the cable to the connector of unit. Incorrect connection may cause malfunctions.

Before starting cleaning, always shut off GOT power externally in all phases. Not doing so can cause a unit failure or malfunction. Undertightening can cause the GOT to drop, short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit.

Do not disassemble or modify any unit. This will cause failure, malfunction, injuries, or fire.

Do not touch the conductive areas and electronic parts of this unit directly. Doing so can cause a unit malfunction or failure.

CAUTION

WARNING

CAUTION

WARNING

CAUTION

WARNING

[DISPOSAL PRECAUTIONS]

[TRANSPORTATION PRECAUTIONS]

Manual

The following shows manuals relevant to this product.

For relevant manuals, refer to the PDF manuals stored in the DVD- ROM for the drawing software used.

Compliance with the EMC and Low Voltage Directives To configure a system meeting the requirements of the EMC and Low Voltage Directives when incorporating the Mitsubishi GOT (EMC and Low Voltage Directives compliant) into other machinery or equipment, refer to "EMC AND LOW VOLTAGE DIRECTIVES" of the General Description included with the GOT used. The CE mark, indicating compliance with the EMC and Low Voltage Directives, is printed on the rating plate of the GOT.

Always secure the cables connected to the unit, e.g. run them in conduits or clamp them. Not doing so can cause unit or cable damage due to dangling, moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault.

Do not hold the cable part when unplugging any cable connected to the unit. Doing so can cause unit or cable damage or a malfunction due to a cable contact fault.

Always make sure to touch the grounded metal to discharge the electricity charged in the body, etc., before touching the unit. Failure to do so may cause a failure or malfunctions of the unit.

Dispose of this product as industrial waste.

Make sure to transport the GOT main unit and/or relevant unit(s) in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of the User's Manual for the GOT used, as they are precision devices. Failure to do so may cause the unit to fail. Check if the unit operates correctly after transportation.

Detailed Manual

Manual name Manual number

(Model code)

GT16 User's Manual (Hardware) (Sold separately)

SH-080928ENG (1D7MD3)

GOT1000 Series Connection Manual (Microcomputer, MODBUS Products, Peripherals) for GT Works3 (Sold separately)

SH-080871ENG (1D7MC5)

GT Designer3 Version1 Screen Design Manual (Functions)

(Sold separately)

SH-080867ENG (1D7MC1)

Relevant Manuals

CAUTION

CAUTION

CAUTION

Compliance with the new China RoHS directive GOT

6 6

SJ/T11364 : GB/T26572

: GB/T26572

Referenced Standard: GB/T15969.2 (Requirement of Chinese standardized law)

Packing List After unpacking the box, check that the following products are included.

1. OVERVIEW

This User's Manual describes the GT16M-ROUT RGB output unit (hereinafter referred to as the RGB output unit). When mounting RGB output unit with GT16 M the RGB output unit can external display screens on GOT.

To use the RGB output unit set the communication settings. For the settings and system configurations, refer to GOT1000 Series Connection Manual. For RGB output functions, refer to GT Designer2 Version Screen Design Manual.

Note: This symbol mark is for China only.

Pb

Hg

Cd

Cr(VI)

PBB

PBDE

Model Product Quantity

GT16M-ROUT

RGB output unit 1

Mounting screw set (4 screws, 4 stickers)

1

Extension interface relay board 1

GT16 RGB Output Unit User's Manual (This manual)

1

GOT+GT16M-ROUT External display

2. SPECIFICATIONS

The following shows the performance specifications of the the RGB

output unit.

The general specifications of the RGB output unit are the same as

those of the GOT.

For the general specifications of the GOT, refer to the User's Manual for the GOT used.

2.1 RGB output unit

2.2 GT1695M-X Timing Chart

2.3 GT1685M-SGT1675M-S and GT1665M-S Timing Chart

Item

Specifications

GT1695M-X GT1685M-S GT1675M-S GT1665M-S

GT1675M-S GT1665M-S

RGB output sectio n

RGB output format

Analog RGB

Display size (dot)

XGA; 1024 768

SVGA; 800 600

VGA; 640 480

Number of RGB output channels

1 channel

Dot clock 65.000 MHz 40.000 MHz 25.175 MHz

Horizontal scanning frequency

48.4 kHz 37.9 kHz 31.5 kHz

Vertical scanning frequency

60 Hz

Timing chart Refer to 2.2. Refer to 2.3. Refer to 2.4.

Connector for external connection

D-Sub15 pin: female

Internal current consumption

3.3VDC 0.13A

5.0VDC 0.11 A

Weight 0.17 kg (0.37 Ib)

Horizontal synchronizing timing Vertical synchronizing timing

Horizontal synchronizing timing Vertical synchronizing timing

HSYNC

Video signal

Horizontal sync width

Horizontal sync

Horizontal synchronizing timing

RGB

analog

0.7Vp-p

2.092 s 2.462 s 0.369 s

20.677 s

15.754 s

VSYNC

Video signal 15.880ms

Vertical sync width

0.124ms Vertical sync

Vertical synchronizing timing

16.666ms

0.600ms 0.062ms

RGB

analog

0.7Vp-p

HSYNC

Video signal

Horizontal sync width

Horizontal sync

Horizontal synchronizing timing

RGB

analog

0.7Vp-p

3.200 s 2.200 s 1.000 s

26.400 s

20.000 s

VSYNC

Video signal 15.840ms

Vertical sync width

0.106ms Vertical sync

Vertical synchronizing timing

16.579ms

0.607ms 0.026ms

RGB

analog

0.7Vp-p

2.4 GT1675M-V and GT1665M-V Timing Chart

3. PART NAMES AND EXTERNAL DIMENSIONS

3.1 RGB Output Unit

3.2 Extension Interface Relay Board

Horizontal synchronizing timing Vertical synchronizing timing

No. Name Description

1) Connector for RGB

output Connector for connecting a 9-core

combined cable

2) Interface connector Connector connected to the GOT

3) Extension connector Connector for connecting an extension unit

4) Board fixing screw Screw for fixing the extension interface

relay board

5) Mounting screw Screw for fixing the RGB output unit

6) Rating plate -

HSYNC

Video signal

Horizontal sync width

Horizontal sync

Horizontal synchronizing timing

RGB

analog

0.7Vp-p

3.813 s 1.907 s 0.636 s

31.778 s

25.422 s

VSYNC

Video signal 15.253ms

Vertical sync width

0.064ms Vertical sync

Vertical synchronizing timing

16.683ms

1.048ms 0.318ms

RGB

analog

0.7Vp-p

X

10 5

(4 .1

3)

98 (3

.8 6)

133 (5.24) 3 (0.12)

2.5 (0.10)

8 (0

.3 1)

30 .5

(1 .2

0) 21

.5 (0

.8 5)

19 (0.75)

8. 5

(0 .3

3)

5)

4)

6)

1)

2)

3) 5) GOT main unit

Dimensions of X when mounted the GOT

Unit : mm (inch)

GOT

12.1" 15" 19.5 (0.77)

18 (0.71) 21 (0.83) 23 (0.91)

10.4" 8.4"

Dimensions of X

Unit : mm (inch)

64 (2.52)

Unit : mm (inch)

2 4

(0 .9

4 )

2 7

.5

(1 .0

8 )

4. INSTALLATION PROCEDURE

The installation procedure for the RGB output unit is explained using the GT1675.

1) Turn off the GOT.

2) Remove two extension unit covers of the GOT.

3) Connect the extension interface relay board to the extend I/F-2 on the GOT. Remove the connector cover from the board.

4) Fit the RGB output unit in the GOT case.

5)Tighten four mounting screws with a torque of 0.36 to 0.48 Nm to fix the unit.

6) Tighten two board fixing screws with a torque of 0.36 to 0.48 Nm to fix the board.

7) For mounting any extension unit on the RGB output unit, remove the connector cover and the stickers. For mounting no extension unit on the RGB output unit, cover over four mounting screws with the accessory stickers to avoid static electricity. Keep the connector cover fixed. Keep all the stickers fixed.

Point

Remove the screws that fixes the extension interface relay board before removing the unit.(Above 6))

4) 3)

Remove the connector cover

5) 6)

Sticker

Accessory sticker

Accessory sticker

Connector cover

Warranty Mitsubishi Electric will not be held liable for damage caused by factors found not to be the cause of Mitsubishi Electric; machine damage or lost profits caused by faults in the Mitsubishi Electric products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi Electric; damages to products other than Mitsubishi Electric products; and to other duties.

For safe use This product has been manufactured as a general-purpose part for

general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.

Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi Electric.

This product has been manufactured under strict quality control. However, when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.

USA

Brazil

Mexico

Germany

UK

Italy

Spain

France

Czech

Turkey

Poland

Russia

South Africa

China

Taiwan

Korea

Singapore

Thailand

Indonesia

Vietnam

India

Australia

Country/Region Sales office/Tel Mitsubishi Electric Automation, Inc. 500 Corporate Woods Parkway, Vernon Hills, IL 60061, U.S.A. Tel: +1-847-478-2100 Mitsubishi Electric do Brasil Comercio e Servicos Ltda. Avenida Adelino Cardana, 293, 21 andar, Bethaville, Barueri SP, Brasil CEP 06401-147 Tel: +55-11-4689-3000 Mitsubishi Electric Automation, Inc. Mexico Branch Mariano Escobedo #69, Col. Zona Industrial, Tlalnepantla Edo. Mexico, C.P.54030 Tel: +52-55-3067-7511 Mitsubishi Electric Europe B.V. German Branch Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany Tel: +49-2102-486-0 Mitsubishi Electric Europe B.V. UK Branch Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, U.K. Tel: +44-1707-28-8780 Mitsubishi Electric Europe B.V. Italian Branch Centro Direzionale Colleoni - Palazzo Sirio, Viale Colleoni 7, Agrate Brianza (MB), Italy Tel: +39-039-60531 Mitsubishi Electric Europe B.V. Spanish Branch Carretera de Rubi 76-80-Apdo.420, 08190 Sant Cugat del Valles (Barcelona), Spain Tel: +34-935-65-3131 Mitsubishi Electric Europe B.V. French Branch 25, Boulevard des Bouvets, 92741 Nanterre Cedex, France Tel: +33-1-55-68-55-68 Mitsubishi Electric Europe B.V. Czech Branch Avenir Business Park, Radlicka 751/113e, 158 00 Praha 5, Czech Republic Tel: +420-251-551-470 Mitsubishi Electric Turkey A.S. Umraniye Branch Serifali Mahallesi Nutuk Sokak No:5, TR-34775 Umraniye / Istanbul, Turkey Tel: +90-216-526-3990 Mitsubishi Electric Europe B.V. Polish Branch ul. Krakowska 50, 32-083 Balice, Poland Tel: +48-12-347-65-00 Mitsubishi Electric (Russia) LLC St. Petersburg Branch Piskarevsky pr. 2, bld 2, lit Sch, BC Benua, office 720; RU-195027 St. Petersburg, Russia Tel: +7-812-633-3497 Adroit Technologies 20 Waterford Office Park, 189 Witkoppen Road, Fourways, Johannesburg, South Africa Tel: +27-11-658-8100 Mitsubishi Electric Automation (China) Ltd. No.1386 Hongqiao Road, Mitsubishi Electric Automation Center, Shanghai, China Tel: +86-21-2322-3030 SETSUYO ENTERPRISE CO., LTD. 6F, No.105, Wugong 3rd Road, Wugu District, New Taipei City 24889, Taiwan Tel: +886-2-2299-2499 Mitsubishi Electric Automation Korea Co., Ltd. 7F-9F, Gangseo Hangang Xi-tower A, 401, Yangcheon-ro, Gangseo-Gu, Seoul 07528, Korea Tel: +82-2-3660-9530 Mitsubishi Electric Asia Pte. Ltd. 307 Alexandra Road, Mitsubishi Electric Building, Singapore 159943 Tel: +65-6473-2308 Mitsubishi Electric Factory Automation (Thailand) Co., Ltd. 12th Floor, SV.City Building, Office Tower 1, No. 896/19 and 20 Rama 3 Road, Kwaeng Bangpongpang, Khet Yannawa, Bangkok 10120, Thailand Tel: +66-2682-6522 to 31 PT. Mitsubishi Electric Indonesia Gedung Jaya 11th Floor, JL. MH. Thamrin No.12, Jakarta Pusat 10340, Indonesia Tel: +62-21-3192-6461 Mitsubishi Electric Vietnam Co., LTD. Ho Chi Minh Head Office Unit 01-04, 10th Floor, Vincom Center, 72 Le Thanh Ton Street, District 1, Ho Chi Minh City, Vietnam Tel: +84-8-3910-5945 Mitsubishi Electric India Pvt. Ltd. Pune Branch Emerald House, EL -3, J Block, M.I.D.C., Bhosari, Pune - 411026, Maharashtra, India Tel: +91-20-2710-2000 Mitsubishi Electric Australia Pty. Ltd. 348 Victoria Road, P.O. Box 11, Rydalmere, N.S.W. 2116, Australia Tel: +61-2-9684-7777

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JA

Manualsnet FAQs

If you want to find out how the GOT1000 Mitsubishi works, you can view and download the Mitsubishi GOT1000 GT16M-ROUT-U RGB Output User's Manual on the Manualsnet website.

Yes, we have the User's Manual for Mitsubishi GOT1000 as well as other Mitsubishi manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The User's Manual should include all the details that are needed to use a Mitsubishi GOT1000. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Mitsubishi GOT1000 GT16M-ROUT-U RGB Output User's Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Mitsubishi GOT1000 GT16M-ROUT-U RGB Output User's Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Mitsubishi GOT1000 GT16M-ROUT-U RGB Output User's Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Mitsubishi GOT1000 GT16M-ROUT-U RGB Output User's Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Mitsubishi GOT1000 GT16M-ROUT-U RGB Output User's Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.