GT27-MMR-Z Set of GT16M-MMR-Z and GT27-IF2000

Thank you for choosing Mitsubishi Electric Graphic Operation Terminal (GOT).

2013 MITSUBISHI ELECTRIC CORPORATION

GOT2000 Series Multimedia Unit

Prior to use, please read both this manual and detailed manual thoroughly to fully understand the product.

MODEL GT27-MMR-Z-U-JE

MODEL CODE

1D7ML3

IB(NA)-0800518-F(2111)MEE

SAFETY PRECAUTIONS (Always read these precautions before using this equipment.)

Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly. The precautions given in this manual are concerned with this product. In this manual, the safety precautions are ranked as "WARNING" and "CAUTION".

Note that the CAUTION level may lead to a serious accident according to the circumstances. Always follow the precautions of both levels because they are important to personal safety. Please save this manual to make it accessible when required and always forward it to the end user.

[DESIGN PRECAUTIONS]

Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.

Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.

Do not bundle the control and communication cables with main-circuit, power or other wiring. Run the above cables separately from such wiring and keep them a minimum of 100mm apart. Not doing so noise can cause a malfunction.

WARNING

CAUTION

CAUTION

[MOUNTING PRECAUTIONS]

[WIRING PRECAUTIONS]

[STARTUP AND MAINTENANCE PRECAUTIONS]

[PRECAUTIONS WHEN THE DATA STORAGE IS IN USE]

[DISPOSAL PRECAUTIONS]

Be sure to shut off all phases of the external power supply used by the system before mounting or removing this unit to/from the GOT. Not doing so can cause a unit failure or malfunction.

Before connecting the Bus connection cable to this unit, always shut off GOT power and PLC CPU power externally in all phases. Not doing so can cause a malfunction.

Use this unit in the environment that satisfies the general specifications described in the User's Manual for the GOT used. Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration.

Do not drop the unit or subject it to string shock. A unit damage may result.

When installing this unit to the GOT, fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range (0.36Nm to 0.48Nm) with a Phillips-head screwdriver No. 2. Undertightening can cause a drop, failure or malfunction. Overtightening can cause a drop, failure or malfunction due to screw or unit damage.

Be sure to shut off all phases of the external power supply used by the system before wiring. Failure to do so may result in an electric shock, product damage or malfunctions.

Exercise care to avoid foreign matter such as chips and wire offcuts entering the unit. Not doing so can cause a fire, failure or malfunction.

Make sure to securely connect the cable to the connector of unit. Incorrect connection may cause malfunctions.

Before starting cleaning or mounting screw retightening, always shut off GOT power externally in all phases. Not doing so can cause a unit failure or malfunction. Tighten the mounting screws in the specified torque range (0.36Nm to 0.48Nm) with a Phillips-head screwdriver No. 2. Undertightening can cause the GOT to drop, short circuit or malfunction. Overtightening can cause a drop, short circuit or malfunction due to the damage of the screws or unit.

Do not disassemble or modify the unit. Doing so can cause a failure, malfunction, injury or fire.

Do not touch the conductive and electronic parts of this unit directly. Doing so can cause a unit malfunction or failure.

The cables connected to the unit must be run in ducts or clamped. Not doing so can cause the unit or cable to be damaged due to the dangling, motion or accidentalpulling of the cables or can cause a malfunction due to a cable connection fault.

When unplugging the cable connected to the unit, do not hold and pull from the cable portion. Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cableconnection fault.

Do not drop the module or subject it to strong shock. A module damage may result.

Before touching the unit, always touch grounded metals, etc. to discharge static electricity from human body, etc. Not doing so can cause the unit to failure or malfunction.

When installing a CF card into this unit, insert it into the card slot of this unit until the CF card eject button pops out. Failure to do so may cause a malfunction due to poor contact.

Before inserting or removing a CF card into/from this unit, turn the CF card access switch off. Failure to do so may corrupt data on the CF card.

When removing a CF card from the GOT, support it by hand, as it may pop out. Failure to do so may cause the CF card to drop from the unit, resulting in a damage or failure.

When disposing of this product, treat it as industrial waste.

WARNING

CAUTION

WARNING

CAUTION

WARNING

CAUTION

CAUTION

CAUTION

[TRANSPORTATION PRECAUTIONS]

Manual

The following shows manuals relevant to this product.

For detailed manuals and relevant manuals, refer to the e-Manual or PDF manuals stored in the DVD-ROM for the screen design software used.

The latest manuals are also available from MITSUBISHI ELECTRIC FA Global Website (www.MitsubishiElectric.com/fa).

Compliance with the EMC and Low Voltage Directives To configure a system meeting the requirements of the EMC and Low Voltage Directives when incorporating the Mitsubishi GOT (EMC and Low Voltage Directives compliant) into other machinery or equipment, refer to "EMC AND LOW VOLTAGE DIRECTIVES" of the General Description included with the GOT used. The CE mark, indicating compliance with the EMC and Low Voltage Directives, is printed on the rating plate of the GOT.

Compliance with the new China RoHS directive GOT

6 6

SJ/T11364 : GB/T26572

:GB/T26572

Referenced Standard: GB/T15969.2 (Requirement of Chinese standardized law)

Packing List The following items are included.

Make sure to transport the GOT main unit and/or relevant unit(s) in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of the User's Manual for the GOT used, as they are precision devices. Failure to do so may cause the unit to fail. Check if the unit operates correctly after transportation.

When fumigants that contain halogen materials such as fluorine, chlorine, bromine, and iodine are used for disinfecting and protecting wooden packaging from insects, they cause malfunction when entering our products. Please take necessary precautions to ensure that remaining materials from fumigant do not enter our products, or treat packaging with methods other than fumigation (heat method). Additionally, disinfect and protect wood from insects before packing products.

Manual name Manual number (Model code)

GOT2000 Series User's Manual (Hardware) (Sold separately)

SH-081194ENG (1D7MJ5)

GOT2000 Series Connection Manual (Microcomputers, MODBUS/Fieldbus Products, Peripherals) For GT Works3 Version1

SH-081200ENG

Note: This symbol mark is for China only.

Pb

Hg

Cd

Cr(VI)

PBB

PBDE

Model Product Quantity

GT27-MMR-Z

Multimedia unit GT16M-MMR-Z 1

Video Interface Converter Unit GT27-IF1000 1

Mounting screw set for Multimedia unit (4 screws (40mm), 4 stickers)

1

Mounting screw set for Video Interface Converter Unit (2 screws (26mm), 2 stickers)

2

Cable clamp (for sound I/O) 1

GOT2000 Series Multimedia Unit User's Manual (This manual)

1

CAUTION

1. OVERVIEW

This users manual describes the GOT2000 Series Multimedia unit (hereinafter referred to as the Multimedia unit). The Multimedia unit is configured with the GT16 Multimedia unit and the Video Interface Converter Unit. The following functions are available by mounting the Multimedia unit on the GT27. The GOT displays a video image taken by a video camera, or the GOT stores

the video image as a video file in a CF card and plays the file. When an error occurs, a video image taken 120 seconds before and after the

error (up to 240 seconds) can be stored as a video file in a CF card. With the Ethernet connection, the GOT sends a video file to the personal

computer using the FTP server function.

*1: To store video files in the personal computer, the FTP server function of the GOT and the multimedia interaction tool are required.

*2: Power on the GOT simultaneously with the video camera. *3: Depending on the video camera type, noise from the power supply cable of the

video camera may cause malfunction of the GOT or a programmable controller. In this case, attach the following line filter to the power supply line of the video camera. Recommended line filter: TDK-Lambda RSHN-2003 (or equivalent products)

To use the Multimedia unit, set the controller settings. For the settings and system configurations, refer to GOT2000 Series Connection Manual (Microcomputer, MODBUS Products, Peripherals) for GT Works3 Version 1. For the details of the multimedia function, refer to GT Designer3 (GOT2000) Help.

2. SPECIFICATIONS

The following shows the performance specifications of the Multimedia unit. The general specifications of the Multimedia unit are the same as those of the GOT. For the general specifications of the GOT, refer to the GOT2000 Series User's Manual (Hardware).

*1:Compatible with PAL and CCIR formats only.

Item Specifications

Video input section

Input format

Color NTSC format, PAL format (interlaced format)

Monochrome EIA format, CCIR format (interlaced format)

Number of channels 1 channel

Video input signal IVp-p, 75 , composite signal

Display size (dot) 640x480 768x576*1

Connector for external connection BNC connector

Sound input section

Number of channels 1 channel

Sound input signal 1 Vrms

Connector for external connection

3.5 stereo mini jack, straight type

Sound output section

Number of channels 1 channel

Sound output signal 1 Vrms (Rated load 10k )

Connector for external connection

3.5 stereo mini jack, straight type

CF Card I/F section

Slot Compact flash Slot (TYPE1) 1 channel

Mode True-IDE mode

Ethernet I/F section

Number of channels 1 channel

Connector for external connection

RJ-45 (modular jack)

Data transfer method 100BASE-TX/10BASE-T

Video file

File format 3GP, MP4

Video coding/decoding format

MPEG-4 Part.2 SP@LV4

Resolution/maximum frame rate

VGA/15fps, QVGA/30fps

Internal current consumption 3.3VDC 0.51A

5.0VDC 0.49A accompanied with the GT27-IF1000

Weight 0.41kg accompanied with the GT27-IF1000

A 1254 348B

GOT

GT27-MMR-Z

Video camera

Do not mount not desmount a module while the power is supplied.

CAUTION

Video image

CF card in the multimedia unit (save/play)

Personal computer

SD card in the GOT

Video file *1

(Ethernet)

3. PART NAMES AND EXTERNAL DIMENSIONS

3.1 Multimedia Unit

3.2 Video Interface Converter Unit

No. Name Description

1) Extension connector Connector for connecting an extension unit

2) Mounting screw Screw for fixing the Video Interface Converter Unit

3) Rating plate -

4) Connector for video input Connector for connecting a coaxial cable

5) CF card access switch Switch for enabling or disabling access to the CF card ON: CF card accessed OFF: CF card not accessed

6) CF card access LED LED lamp lit when the CF card is accessed

7) CF card interface Interface for inserting a CF card

8) Sound input terminal Terminal for connecting the cable of the sound input device

9) Sound output terminal Terminal for connecting the cable of the sound output device

10) Video connector Video connector connected to the Video Interface Converter Unit

11) Ethernet interface Connector for Ethernet communication

12) Interface connector Connector connected to the Video Interface Converter Unit

No. Name Description

1) Extension connector Connector for connecting the Multimedia unit

2) Mounting screw Screw for fixing the RGB output unit

3) Rating plate -

4) Video connector Video connector for connecting the Multimedia unit

5) Auxiliary extension connector

Auxiliary extension connector connected to the GOT

6) Interface connector Connector connected to the GOT

133 (5.24)

12 8

(5 .0

4)

98 (3

.8 6)

23 (3

.8 6)

9 (0

.3 5) 14

(0 .5

5)

44 (1

.7 3)

35 (1

.3 8)

111 (4.37) 86 (3.39)

46 (1.81) 32 (1.26)

26 (1

.0 2)

8 (0

.3 1)

1)

9) 8)

2)

2)

4)

11) 10)12)

3)

6)

GT16M-MMR-Z

58 (2.29)

7)

5)

GOT main unit GT27-IF1000

Unit : mm (inch)

10 5

(4 .1

4)

133 (5.24)

98 (3

.8 6)

30 .5

(1 .2

0) 21

.5 (0

.8 5)

Unit : mm (inch)

1) 2)

2)

3)

4)

5)6)

4. INSTALLATION AND REMOVAL PROCEDURE

4.1 Cable Connection 1) Connect the cables of the sound I/O devices to the Multimedia unit. 2) Attach the cable clamp to the Multimedia unit.

Position the cable clamp band outside, and insert the cable clamp to section A shown in the following figure until it clicks. For the band inserting direction, refer to the arrow. (The cable clamp is the RSG-130-V0 of KITAGAWA INDUSTRIES CO.,LTD. or equivalent.)

3) Pull up the two hooks in the extension unit cover (two covers) of the GOT to remove the cover toward the opposite side of the cover as a fulcrum.

4.2 Unit Installation The installation procedure for the Multimedia unit is explained using the GT2712.

1) Turn off the GOT. 2) Pull up the two hooks in the extension unit cover (two covers) of the GOT to

remove the cover toward the opposite side of the hoots of the cover as a fulcrum.

3) Connect the Video Interface Converter Unit to the auxiliary extension interface and the extension interface on the GOT. After connecting it, tighten four mounting screws (26mm) with a torque of 0.36Nm to 0.48Nm to fix the unit.

4) Fit the Multimedia unit in the Video Interface Converter Unit case. 5) Tighten four mounting screws (40mm) of Multimedia unit with a torque of

0.36Nm to 0.48Nm to fix the unit.

6) For mounting any extension unit on Multimedia unit, remove the connector cover and the stickers. For mounting no extension unit on the Multimedia unit, cover over four mounting screws with the accessory stickers to the Multimedia unit or the Video Interface Converter Unit to avoid static electricity. Keep the connector cover fixed. Keep all the stickers fixed.

1)

Cable of the sound I/O device

2) 3)

Cable clamp

A

4.3 Unit Removal For removing the Multimedia unit, reverse the procedure of the installation.

5. CF CARD INSTALLATION/REMOVAL PROCEDURE

5.1 Installation 1) Open the CF card cover, and turn off the CF card access switch of the unit.

2) Insert a CF card into the CF card interface with the front side facing up. 3) Turn on the CF card access switch.

5.2 Removal 1) Open the CF card cover.

Turn off the CF card access switch, and check that the CF card access LED turns off. (When the CF card access LED is off, the CF card can be removed even while the GOT power is on.

2) Press the CF card eject button to pop out the CF card, and remove the card.

Point

Precautions for connecting sound I/O devices Do not connect or disconnect the cables of the sound I/O sections during

sound input or output. Do not connect devices other than sound I/O devices to the sound I/O

sections of the Multimedia unit. Cable clamp (1) Removing cable clamp band

The cable clamp band can be removed after the cables are fixed. Press the tab of the cable clamp upward using a screwdriver and others, and pull out the band.

(2) Removing cables from the Multimedia unit The cables of the sound I/O devices can be removed from the unit even if the cables are fixed with the cable clamp. Remove the cables by pressing the cable clamp from both directions (arrow A).

Connector cover Accessory sticker

Accessory sticker

Sticker

A

Warranty Mitsubishi Electric will not be held liable for damage caused by factors found not to be the cause of Mitsubishi Electric; machine damage or lost profits caused by faults in the Mitsubishi Electric products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi Electric; damages to products other than Mitsubishi Electric products; and to other duties.

For safe use This product has been manufactured as a general-purpose part for

general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.

Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi Electric.

This product has been manufactured under strict quality control. However, when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.

Country/Region Sales office/Tel

USA Mitsubishi Electric Automation, Inc. 500 Corporate Woods Parkway, Vernon Hills, IL 60061, U.S.A. Tel: +1-847-478-2100

Brazil Mitsubishi Electric do Brasil Comercio e Servicos Ltda. Avenida Adelino Cardana, 293, 21 andar, Bethaville, Barueri SP, Brazil Tel: +55-11-4689-3000

Mexico Mitsubishi Electric Automation, Inc. Mexico Branch Boulevard Miguel de Cervantes Saavedra 301, Torre Norte Piso 5, Ampliacion Granada, Miguel Hidalgo, Ciudad de Mexico, Mexico, C.P.11520 Tel: +52-55-3067-7512

Germany Mitsubishi Electric Europe B.V. German Branch Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany Tel: +49-2102-486-0

UK Mitsubishi Electric Europe B.V. UK Branch Travellers Lane, UK-Hatfield, Hertfordshire, AL10 8XB, U.K. Tel: +44-1707-28-8780

Italy Mitsubishi Electric Europe B.V. Italian Branch Centro Direzionale Colleoni - Palazzo Sirio, Viale Colleoni 7, 20864 Agrate Brianza (MB), Italy Tel: +39-039-60531

Spain Mitsubishi Electric Europe B.V. Spanish Branch Carretera de Rubi, 76-80-Apdo. 420, E-08190 Sant Cugat del Valles (Barcelona), Spain Tel: +34-935-65-3131

France Mitsubishi Electric Europe B.V. French Branch 25, Boulevard des Bouvets, 92741 Nanterre Cedex, France Tel: +33-1-55-68-55-68

Czech Mitsubishi Electric Europe B.V. Czech Branch Pekarska 621/7, 155 00 Praha 5, Czech Republic Tel: +420-255 719 200

Turkey Mitsubishi Electric Turkey A.S. Umraniye Branch Serifali Mahallesi Nutuk Sokak No:5, TR-34775 Umraniye / Istanbul, Turkey Tel: +90-216-526-3990

Poland Mitsubishi Electric Europe B.V. Polish Branch ul. Krakowska 48, 32-083 Balice, Poland Tel: +48-12-347-65-00

Russia Mitsubishi Electric (Russia) LLC St. Petersburg Branch Piskarevsky pr. 2, bld 2, lit "Sch", BC "Benua", office 720; 195027 St. Petersburg, Russia Tel: +7-812-633-3497

South Africa Adroit Technologies 20 Waterford Office Park, 189 Witkoppen Road, Fourways, South Africa Tel: +27-11-658-8100

China Mitsubishi Electric Automation (China) Ltd. Mitsubishi Electric Automation Center, No.1386 Hongqiao Road, Shanghai, China Tel: +86-21-2322-3030

Taiwan SETSUYO ENTERPRISE CO., LTD. 6F, No.105, Wugong 3rd Road, Wugu District, New Taipei City 24889, Taiwan Tel: +886-2-2299-2499

Korea Mitsubishi Electric Automation Korea Co., Ltd. 7F to 9F, Gangseo Hangang Xi-tower A, 401, Yangcheon-ro, Gangseo-Gu, Seoul 07528, Korea Tel: +82-2-3660-9569

Singapore Mitsubishi Electric Asia Pte. Ltd. 307 Alexandra Road, Mitsubishi Electric Building, Singapore 159943 Tel: +65-6473-2308

Thailand Mitsubishi Electric Factory Automation (Thailand) Co., Ltd. 12th Floor, SV.City Building, Office Tower 1, No. 896/19 and 20 Rama 3 Road, Kwaeng Bangpongpang, Khet Yannawa, Bangkok 10120, Thailand Tel: +66-2682-6522 to 31

Indonesia PT. Mitsubishi Electric Indonesia Gedung Jaya 8th Floor, JL. MH. Thamrin No.12, Jakarta Pusat 10340, Indonesia Tel: +62-21 3192-6461

Vietnam Mitsubishi Electric Vietnam Company Limited 11th & 12th Floor, Viettel Tower B, 285 Cach Mang Thang 8 Street, Ward 12, District 10, Ho Chi Minh City, Vietnam. Tel: +84-28-3910-5945

India Mitsubishi Electric India Pvt. Ltd. Pune Branch Emerald House, EL-3, J Block, M.I.D.C., Bhosari, Pune - 411026, Maharashtra, India Tel: +91-20-2710-2000

Australia MITSUBISHI ELECTRIC AUSTRALIA PTY. LTD. 348 Victoria Road, P.O. Box 11, Rydalmere, N.S.W 2116, Australia Tel: +61-2-9684-7777

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN

When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission.

Specifications subject to change without notice. Printed in Japan, November 2021.

Manualsnet FAQs

If you want to find out how the GOT2000 Mitsubishi works, you can view and download the Mitsubishi GOT2000 GT16M-MMR-Z Multimedia User's Manual on the Manualsnet website.

Yes, we have the User's Manual for Mitsubishi GOT2000 as well as other Mitsubishi manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The User's Manual should include all the details that are needed to use a Mitsubishi GOT2000. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Mitsubishi GOT2000 GT16M-MMR-Z Multimedia User's Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Mitsubishi GOT2000 GT16M-MMR-Z Multimedia User's Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Mitsubishi GOT2000 GT16M-MMR-Z Multimedia User's Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Mitsubishi GOT2000 GT16M-MMR-Z Multimedia User's Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Mitsubishi GOT2000 GT16M-MMR-Z Multimedia User's Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.