Mitsubishi QE83WH4W Measuring Module User's Manual PDF

1 of 1
1 of 1

Summary of Content for Mitsubishi QE83WH4W Measuring Module User's Manual PDF

1k

2k

1l

2l

3l

3k

1k

2k

1l

2l

3l

3k

1k

2k

1l

2l

C H 1

C H 2

C H 3

3l

3k

PA

PB

PC

PD

SLD

1k

2k

1l

2l

3l

3k

1k

2k

1l

2l

3l

3k

1k

2k

1l

2l

C H 1

C H 2

C H 3

3l

3k

PA

PB

PC

PD

SLD

1 2 3 0

1 2 3 0

Energy Measuring Module Model QE83WH4W

Users Manual Hardware Before using this module, please read both this manual and Details carefully and pay full attention to safety to handle this module correctly. Make sure that the end users read this manual and then keep the manual in a safe place for future reference. ABOUT MANUALS

The following manuals are also related to this module. Order each manual as needed, referring to the following list.

Manual name Manual numbermodel code Energy Measuring Module Users ManualDetails QE83WH4W IB6372219H866

COMPLIANCE WITH THE EMC AND LOW VOLTAGE DIRECTIVES (1) For programmable controller system

To configure a system meeting the requirements of the EMC and Low Voltage Directives when incorporating the Mitsubishi programmable controller (EMC and Low Voltage Directives compliant) into other machinery or equipment, refer to Chapter 9 "EMCAND LOW VOLTAGE DIRECTIVES" of the QCPU User's Manual (Hardware Design, Maintenance and Inspection). The CE mark, indicating compliance with the EMC and Low Voltage Directives, is printed on the rating plate of the programmable controller.

(2) For this module For the compliance of this module with the EMC and Low Voltage Directives, refer to Section 6.1 Wiring.

(1)This Energy Measuring Module can measure three channels of various types of electric quantity. It can measure three channels of electric energy, reactive energy, current, voltage, electric power, reactive power, apparent power, power factor, and frequency. Both consumption and regeneration of the electric energy can be measured.

(2)Extensive monitoring functions In addition to memorizing the maximum and minimum values, two types of alarm monitoring for upper and lower limit can be performed for each channel.

(3)It also can measure the electric energy for a certain period. It can measure the electric energy for the duration of time for which the output device is on. This feature enables to acquire the electric energy needed during device operation or energy per tact.

(4)Equipped with the current measuring mode where eight channels of current can be measured. By selecting the current measuring mode using the intelligent function module switch, you can measure only the current through eight channels. Note that the input/output signals and buffer memory to be used in the current measuring mode are different from those used in the regular operation mode. For details, refer to "Users Manual (Details)".

The following items for this device are included in the package. Check that no items are missing. Energy Measuring Module x 1 Voltage input terminal block x 1 Users Manual (Hardware) x 1

3.1 Precautions for Operating Environment and Conditions Do not use this product in the places listed below. Failure to follow the instruction may cause malfunctions and a life decrease of product.

Places the Ambient temperature exceeds the range 0 55C. Places the Relative humidity exceeds the range 5 95% or places with dewfall. Altitude exceeds 2000 m. Places exposed to rain or water drop. Dust, corrosive gas, saline and oil smoke exist. Vibration and impact exceed the specifications. Installed excluding the control panel.

3.2 Matters concerning the preparation before use Use the module in the specified usage environment and conditions. The setting of this module primary voltage, primary current necessary before using it. Please refer to "Users Manual (Details)" about each setting method.

3.3 Installation and Wiring Precautions Shut off the external power supply for the module in all phases before installing or wiring. Failure to do so may cause an electric shock or damage of the module.

Any person who is involved in the installation and the wiring of this Sequencer should be fully competent todo the work. Use the programmable controller in an environment that meets the general specifications in the Users Manual for the CPU module used. Failure to do so may result in electric shock, fire, malfunction, or damage to or deterioration of the product. To mount the module, while pressing the module-mounting lever located in the lower part of the module, fully insert the module fixing projection(s) into the hole(s) in the base unit and press the module until it snaps into place. Incorrect mounting maycause malfunction, failure or drop of the module. When using the Sequencer in an environment of frequent vibrations, fix the module with a screw. Tighten the screw within the specified torque range. Under tightening can cause drop of the screw, short circuit or malfunction. Over tightening can damage the screw and/or module, resulting in drop, short circuit, or malfunction. Shut off the external power supply for the system in all phases before mounting or removing the module. Failure to do so mayresult in damage to the product. Do not directly touch any conductive part of the module. Doing so can cause malfunction or failure of the module. FG terminal must be grounded according to the D-type ground (Type 3) dedicated for sequencer. Failure to do so may result in an electric shock or a malfunction. When using this product, make sure to use it in combination with current sensor (EMU-CT series or EMU2-CT5-4). Please not to exceed the rating of this product for input of current sensor. For further details, please refer to current sensor manual to maintain the functionality and the accuracy of this product. The dedicated current sensor (EMU-CT50/CT100/CT250/CT400/CT600) is used only for low voltage circuit. It cannot be used with a high voltage circuit. Also, EMU2-CT5-4W should be used with the secondary side (5 A) of transformer transfixed. If it is connected with a high-voltage circuit by mistake, it may cause a burnout of the device and a fire. It is critically dangerous. Measurement circuit voltage cannot be input directly into the module. Please enter the output voltage of the voltage transform unit (QE8WH4VT) The dedicated current sensor has a polarity (directionality). Be careful about it when installing the module. Take care not entering any foreign objects such as ships and wire pieces into the module. It may cause a fire, a failure or a malfunction. In order to prevent the module from incoming foreign objects such as wire pieces during wiring work, a foreign-object preventive label is placed on the module. While a wiring work is performed, keep the label on the module. Before operating the system, peel off the label for heat release. If the foreign-object preventive label is not peeled and the system is in use, residual heat inside the module may reduce the product life. The wires to be connected to the module shall be placed in a duct or fixed together by clamping. If the electric wires are not placed in the duct or clamped together, loosen wires or their movement or careless stretch may cause a breakage of the module or wire or a malfunction due to poor contact of electric wires. Use appropriate size of electric wires. If inappropriate size of electric wire is used, it may cause a fire due to generated heat. Use the applicable solderless terminals (R1.25-3) for current input terminals. If inappropriate solderless terminal is used, a wire breakage or a contact failure may occur, which may cause a device malfunction, a failure, a burnout, or a fire. When using stranded wires for the voltage input terminals, strand the wire edges to prevent thin wires from loosening. After inserting the electric wire or a solderless terminal, make sure that no missing insertion is existing. Missing insertion maycause a device malfunction, a fire, or an electric shock. If the wires connected to the module are strongly pulled off, it may cause a malfunction or a breakage to the module or the wire. Ensure the wiring to the module properly, checking the rated voltage and current of the product and the terminal pin assignment. If the input voltage exceed the rated voltage or the wiring is improper, it may cause a fire or a breakage. (Tensile load: 22N or less) Do not exceed the specified voltage when doing an insulation resistance test and a commercial frequency withstand voltage test. To protect persons who do not have adequate knowledge of electric equipment from electric shocks, any of the following measures should be taken for the panel. (a) To lock the panel so that only trained persons having adequate knowledge of electric equipment can open it. (b) To design the structure so that the power is automatically interrupted upon opening of the panel. The protection class of the panel should be IP2X or higher.

Mitsubishi Programmable Controller

1. Features

2. Checking packaged contents

3. Safety Precautions

Danger

Caution

3.4 Precautions for Start-up and Maintenance Use the product within the ratings specified in this manual. If it is used outside the ratings, it may cause

not only malfunction or failure but also fire or burnout. Before operating the product, check that active bare wire, etc. does not exist around the product. If any

bare wire is found, stop the operation immediately, and take an appropriate action such as isolation protection.

Do not disassemble or modify the module. It may cause failure, malfunction, injury or fire. Attaching and detaching the module must be performed after the power source is shut off for all

outside phases. If all phases are not shut off, it may cause electric shock, failure or malfunction of the module.

Do not touch powered wires. It may cause malfunction. Tighten mounting screws and cleaning module must be performed after the power source is shut off for all outside phases. If all phases are not shut off, it may cause electric shock, failure or malfunction of the module. Use a soft dry cloth to clean off dirt of the module surface. Do not let a chemical cloth remain on the surface for an extended period of time nor wipe the surface

with thinner or benzene. Check for the following items to use this module properly for long time. (1) No damage on this module (2) No abnormality with LED indicators (3) No abnormal noise, smell or

heat. (4) No looseness with installation, wire connection to terminal blocks, and connector connection. (Check these items under the electric outage condition.)

4.1 Names and functions of parts of QE83WH4W are provided below.

(2)Current input terminals Connect the current wire of the measuring circuit with the secondary output of the dedicated current sensor.

(1)LED Operating status of this module is displayed.

(3)Voltage input terminals Connect the voltage input wire of the measuring circuit.

Terminal symbol Name of terminal

1k 1l

1-phase current input terminal (power source side) 1-phase current input terminal (load side)

2k 2l

2-phase current input terminal (power source side) 2-phase current input terminal (load side)CH1

3k 3l

3-phase current input terminal (power source side) 3-phase current input terminal (load side)

1k 1l

1-phase current input terminal (power source side) 1-phase current input terminal (load side)

2k 2l

2-phase current input terminal (power source side) 2-phase current input terminal (load side)CH2

3k 3l

3-phase current input terminal (power source side) 3-phase current input terminal (load side)

1k 1l

1-phase current input terminal (power source side) 1-phase current input terminal (load side)

2k 2l

2-phase current input terminal (power source side) 2-phase current input terminal (load side)CH3

3k 3l

3-phase current input terminal (power source side) 3-phase current input terminal (load side)

PA, PB PC, PD

Terminal for connecting the secondary terminal block of the voltage transform unit

SLD Shield connection terminal

4.2 Names and functions of LEDs The following describes names and functions of LEDs.

Name Color Role Indicator condition

0 LED Green Displays the operation status of this module. ON: Normal operation OFF: Internal power shut-off, hardware error *1

1 LED Green Displays CH1 measurement status of this module. 2 LED Green Displays CH2 measurement status of this module. 3 LED Green Displays CH3 measurement status of this module.

ON: Measuring electric energy (consumption) Flashing: Measuring electric energy (regeneration) OFF: Not measuring (No measurement)

4 LED Green Displays CH1 1-side measurement status (regeneration) of this module.

5 LED Green Displays CH2 1-side measurement status (regeneration) of this module.

6 LED Green Displays CH3 1-side measurement status (regeneration) of this module.

ON: Measuring electric energy (regeneration) on side 1 OFF: Other than the above

7 LED - - Always OFF.

8 LED Red Displays errors and conditions of this module. Flashing: Out-of-range error *1 ON: Hardware error *1 OFF: Normal operation

9 LED Green Displays CH1 2-side measurement status (regeneration) of this module.

A LED Green Displays CH2 2-side measurement status (regeneration) of this module.

B LED Green Displays CH3 2-side measurement status (regeneration) of this module.

ON: Measuring electric energy (regeneration) on side 2 OFF: Other than the above

C LED Green Displays CH1 3-side measurement status (regeneration) of this module.

D LED Green Displays CH2 3-side measurement status (regeneration) of this module.

E LED Green Displays CH3 3-side measurement status (regeneration) of this module.

ON: Measuring electric energy (regeneration) on side 3 OFF: Other than the above

F LED - - Always OFF.

1For details, check with the list of error codes. (Refer to section 9.1)

5.1 How to attach to the base unit

Attach to the base unit of MELSEC-Q series. When attaching the module, make sure to insert the protruding portions for fixing the module into the holes on the base unit. In doing so, insert it securely so that the protruding portion of the module does not come off of the holes. Do not force to attach the module; otherwise the module may break. When installing the module at a vibrating area with strong impact, tighten the module to the base unit using screws. Fixing-Module screw (arranged by user): M3 x 12mm Tightening torque of the fixing-module screws: 0.36 0.48 Nm

Names of signals of terminal block

Caution

4. Name and function of each part 5. Attaching and removing the module

Insert it securely so that the protruding portion for fixing the module*1 does not come off of the module-fixing hole.

Push the unit toward the arrow direction, as the module-fixing hole being a fulcrum point, until you hear a click sound to firmly attach it to the based module.

Check that the module is firmly inserted to the base unit.

Complete

6.1 Wiring Follow the wiring diagram for external connection of QE83WH4W. Current sensor (EMU-CT50/CT100/CT250/CT400/CT600, EMU2-CT5-4W) is necessary for the connection of the current circuit. Voltage transform unit (QE8WH4VT) is necessary for the connection of the voltage circuit. In addition, up to five QE83WH4W modules can be connected to one voltage transform unit. Please refer to the Users Manual (Details) of this module, and the installation method and the detailed specifications of the current sensor and the voltage transform unit.

Make sure that before connecting the cable, the direction of the current sensor is correct for attachment. K to L is the correct direction. K: power source side, L: load side.

The available range of the voltage transform unit is from 55/95V AC to 227/480V AC. When this product is used in a circuit more than 227/480VAC, voltage transformer is required.

The available phase voltage of the transformer is up to 6600V. Connect the secondary side of the transformer to the terminal (P1, P2, P3, P0) of the Voltage transform unit. Make sure that terminal symbols are correct. This product cannot connect with the secondary side of the transformer directly.

6.2 How to connect wires Use appropriate electric wires and tighten a screw by appropriate torque as described right.

Applicable wire(Usable electric wire)

Voltage input terminals Insert a wire to the terminal all the way until it touches the end. Stripping length of the used wire in use has to be 7mm. When using a stranded wire, strand the wire edges to prevent thin wires from loosening.

Current input terminals Use an applicable solderless terminals. No solderless terminal with insulation sleeve can be used on the terminal block.

It is recommended to cover the solderless terminals connecting electric cables with a mark tube or insulating tube. Applicable solderless terminals for current input terminals

: R1.25-3 (No solderless terminal with insulation sleeve can be used).

Voltage input terminals Current input terminals

Single wire AWG24-16 - Stranded wire AWG20-16 AWG20-18 Tightening torque [Nm] 0.4-0.5 0.42-0.58

* To comply with UL/c-UL standards, use the wires meeting the following requirements. The rated temperature of the copper conductor should be 60C/75C. Cble applicable (Fil lectrique utilisable)

Terminals de tension d'entre Terminals de courant d'entre

Cble simple AWG24-16 - Cble brin AWG20-16 AWG20-18

Couple de serrage [Nm] 0.4-0.5 0.42-0.58 * Pour tre conforme UL/c-UL standard, utilisez le fil lectrique selon les conditions suivantes. La temprature classe du conduit en cuivre doit tre 60C/75C.

Input signal wire shall not be bound together with or placed close to the main circuit and power line. Keep 300 mm or longer distance between them.(Except for the terminal input section) It may cause malfunction due to noise The input wiring of the measurement circuit uses separate cables which is different from other signal cables, and do not be affected by serge and the instruction of the interchange side. In actual use, connect the SLD terminal to a shield.

6. How to wire

Load 3Load 1

EMU-CT***model split current sensor (50/100/250/400/600)

Current transformer ***/5A

Load side

Power source side

Voltage transform unit QE8WH4VT

Three-phase 4-wire (with the voltage transform unit / Separated type current transformer) Three-phase 4-wire (with the voltage transform unit / voltage transformer / current transformer)

Load side

Power source side

5A current sensor EMU2-CT5-4W

5A current sensor cable EMU2-CB-Q5B-4W

Load side Voltage transformer for gauge

Voltage transform unit QE8WH4VT

*For a low voltage circuit,grounding of the secondary sides of VT is not necessary.

Caution

Note: Unit of number is mm.

8. Specifications The charge-free warranty period for the product shall be 1 year from the date of your purchase or the date the product is delivered your specified delivery location. However, the maximum limit of the charge-free warranty period shall be set to 18 months from the time of manufacture by defining the longest distribution period of the product as 6 months after the product is shipped from our manufacturing factory. Also, the charge-free warranty period for the replacement product shall not be extended exceeding the charge-free warranty period for the original product.

Our company shall not be liable to compensate for any loss arising from events not attributable to our company, opportunity loss and lost earning of the customer due to failure of the product, and loss, secondary loss, accident compensation, damage to other products besides our products and other operations caused by a special reason regardless of our companys predictability in both within and beyond the charge-free warranty period.

If an abnormal sound, bad-smelling smoke, fever break out from this module, I switch it off promptly, and dont use it.

Item Specifications Model QE83WH4W Phase-wire system three-phase 4-wire

Rating

Voltage circuit

63.5/110 277/480V AC Selected from: 63.5/110V 100/173V 105/182V

110/190V115/199V120/208V127/220V200/346V 220/380V230/400V240/415V242/420V250/430V 254/440V265/460V277/480V Each value refers to the primary voltage of voltage transform unit (QE8WH4VT). If more than 277/480 V AC, use a transformer (VT). Primary voltage of VT can be set up to 6600V

Current circuit

50 A, 100 A, 250 A, 400 A, 600 A AC (The dedicated split type current sensor is used. Each value refers to the current at the primary side of the current sensor.) 5AAC (The dedicated split type current sensor is used. 5 A current sensor is used together with the current transformer (CT), and the primary-side current is configurable up to 6000 A.)

Frequency 50Hz-60Hz

Allowable tolerance of module (excluding the current sensor) (Under the current measuring mode, measures current only)

Current, current demand: 1.0% (100% of the rating) Voltage: 1.0% (100% of the rating) Electric power, electric power demand

: 1.0% (100% of the rating) Reactive power: 1.0% (100% of the rating) Apparent power: 1.0% (100% of the rating) Frequency: 1.0% (45 65 Hz range of the rating) Power factor: 3.0% (against the electric angle 90) Electric energy: 2.0%

(5 100% range of the rating, power factor = 1) Reactive energy: 2.5%

(10 100% range of the rating, power factor = 0)

Measurable circuit count 3 circuits under the same voltage system (3 channels), or 8 circuits (8 channels) in the current measuring mode

Operating temperature 0 55C (Average daily temperature 35C or below) Operating humidity 5 95% RH (No condensation) Storage temperature -25 +75C Operating altitude 2000 m or below

Commercial frequency withstand voltage

Between voltage/current input terminals - SLD terminal: 2210 V AC 5 sec

Between voltage/current input terminals - sequencer power source and GND terminals:

2210 V AC 5 sec

Standard EMC :EN61131-2:2007, EN61326-1:2006 LVD :EN61131-2:2007, EN61010-1:2010

Installation area Inside a control panel

KCC-REI-MEK-19H013

Appllicant MITSUBISHI ELECTRIC AUTOMATION KOREA CO.Ltd

Equipment Name Energy Measuring Module

Model QE83WH4W

Made In JAPAN

Manufacturer

MITSUBISHI ELECTRIC CORPORATION FUKUYAMA WORKS

A ( )

,

.

(A)

7. Dimensions 9. Warranty

Caution

10. Customer Service

Please refer to "catalog" or users manual (Details) for more detail. HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, Japan

View

View

P1

P2

P3

FG

P0

SLD

PA

PB

PC

PD

QE83WH4W

1k 1l

2k 2l

CH1

3k 3l

1k 1l

2l 2k

3k 3l

1k 1l

2l 2k

3k 3l

CH2

CH3

P A

P B

P C

P D

SLD

View

View

P1

P2

P3

FG

P0

SLD

PA

PB

PC

PD

P A

P B

P C

P D

SLD

QE83WH4W

1k 1l

2k 2l

CH1

3k 3l

1k 1l

2l 2k

3k 3l

1k 1l

2l 2k

3k 3l

CH2

CH3

2l

2k

3l

3k

1k

1l

1k

3k

2k

2l

1l

3l

1k

2k

1l

2l

C H 1

3l

3k

1k

2k

1l

2l

C H 2

3l

3k

1k

2k

1l

2l

C H 3

3l

3k

QE83WH4W

D PSLD

0

1

2

3

4

5

6

7

8

9

A

B

C

D

E

F

QE83WH4W

112

A PB PC P

1k

2k

1l

2l

C H 1

3l

3k

1k

2k

1l

2l

C H 2

3l

3k

1k

2k

1l

2l

C H 3

3l

3k

27 4

9 8

21 .5

Base unit

Module

Unit connector Base unit

Protrusion for fixing the module (*1)

Lever for attaching the module

module(*2) Hook for fixing t

Manualsnet FAQs

If you want to find out how the QE83WH4W Mitsubishi works, you can view and download the Mitsubishi QE83WH4W Measuring Module User's Manual on the Manualsnet website.

Yes, we have the User's Manual for Mitsubishi QE83WH4W as well as other Mitsubishi manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The User's Manual should include all the details that are needed to use a Mitsubishi QE83WH4W. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Mitsubishi QE83WH4W Measuring Module User's Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Mitsubishi QE83WH4W Measuring Module User's Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Mitsubishi QE83WH4W Measuring Module User's Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Mitsubishi QE83WH4W Measuring Module User's Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Mitsubishi QE83WH4W Measuring Module User's Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.