User's Manual GT15-J71GF13-T2

Thank you for choosing Mitsubishi Electric Graphic Operation Terminal (GOT).

2011 MITSUBISHI ELECTRIC CORPORATION

GOT2000/GOT1000 Series CC-Link IE Field Network

Communication Unit

Prior to use, please read both this manual and detailed manual thoroughly to fully understand the product.

MODEL GT15-J71GF13-T2-U

MODEL CODE 1D7ME6

IB(NA)-0800473-H(2011)MEE

SAFETY PRECAUTIONS (Always read these precautions before using this equipment.)

Before using this product, please read this manual and the relevant manuals intro- duced in this manual carefully and pay full attention to safety to handle the product correctly. The precautions given in this manual are concerned with this product. In this manual, the safety precautions are ranked as "WARNING" and "CAUTION".

Note that the CAUTION level may lead to a serious accident according to the circumstances. Always follow the precautions of both levels because they are important to per- sonal safety. Please save this manual to make it accessible when required and always forward it to the end user.

[INSTALLATION PRECAUTIONS]

Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.

Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.

Be sure to shut off all phases of the external power supply used by the system before mounting or removing this unit to/from the GOT. Not doing so can cause a unit failure or malfunction.

WARNING

CAUTION

WARNING

[DESIGN PRECAUTIONS]

[WIRING PRECAUTIONS]

[STARTUP AND MAINTENANCE PRECAUTIONS]

Use this unit in the environment that satisfies the general specifications described in the User's Manual for the GOT used. Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration.

When installing this unit to the GOT, fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range (0.36 Nm to 0.48 Nm) with a Phillips-head screwdriver No.2. Undertightening can cause a drop, failure or malfunction. Overtightening can cause a drop, failure or malfunction due to screw or unit damage.

Do not directory touch the conductive part or electronic components of the unit. This may cause the unit to fail or malfunction.

If a communication fails in data link, the faulty station holds the data link data generated before the communication error. Create an interlock circuit in the sequence program using the communication status information in order that the system will operate safely. Failure to do so may cause mis-outputs or malfunctions, resulting in accidents. Check the faulty station and the operation status during communication error by referring to the relevant manuals.

Some failures of cable or communication unit may cause the GOT to keep the outputs on or off. Create an external circuit for monitoring output signals that may lead to serious accidents. Failure to do so may cause mis-outputs or malfunctions, resulting in accidents.

If a communication error (including cable disconnection) occurs during monitoring, the communication between the GOT and programmable controller CPU may be interrupted and the GOT may be inoperative. For bus connection : The programmable controller CPU is down and the GOT is inoperative. For other than above: The GOT is inoperative. When configuring a system including the GOT, the possibility of GOT communication error must be considered; make sure the operation significant for the system will be performed by switches on devices other than the GOT. Failure to do so may cause mis-outputs or malfunctions, resulting in accidents.

To maintain the security (confidentiality, integrity, and availability) of the GOT and the system against unauthorized access, DoS*1 attacks, computer viruses, and other cyberattacks from unreliable networks and devices via network, take appropriate measures such as firewalls, virtual private networks (VPNs), and antivirus solutions. Mitsubishi Electric shall have no responsibility or liability for any problems involving GOT trouble and system trouble by unauthorized access, DoS attacks, computer viruses, and other cyberattacks. *1 DoS: A denial-of-service (DoS) attack disrupts services by overloading systems or exploiting vulnerabilities, resulting in a denial-of-service (DoS) state.

Do not bunch the control wires or communication cables with the main circuit or power wires, or lay them close to each other. As a guide, separate the lines by a distance of at least 100mm (3.94 inches) otherwise malfunctions may occur due to noise.

Be sure to shut off all phases of the external power supply used by the system before wiring. Failure to do so may cause electric shock, product damage or malfunctions.

Be careful not to let foreign matter such as dust or wire chips get inside the unit. This may cause a fire, failure or malfunctions.

Make sure to securely connect the cable to the connector of unit. Incorrect connection may cause malfunctions.

Make sure to fix communication cables and power cables to the unit by ducts or clamps. Failure to do so may cause damage of the unit or the cables due to accidental pull or unintentional shifting of the cables, or malfunctions due to poor contact of the cables.

Do not hold the cable by hand and pull it out from the unit. When removing the cable from the unit, make sure to hold the connector by hand and pull it. Failure to do so may cause malfunctions or damage to the unit or cable.

Do not touch the connector while power is on. Failure to do so may cause electric shock or malfunctions.

Before starting cleaning, always shut off GOT power externally in all phases. Not doing so can cause a unit failure or malfunction.

Do not disassemble or modify any unit. This will cause failure, malfunction, injuries, or fire.

Do not touch the conductive areas and electronic parts of this unit directly. Doing so can cause a unit malfunction or failure.

Make sure to externally shut off all phases of the power supply before cleaning the unit and retightening unit mounting screws. Failure to do so may cause the unit to fail or malfunction. Loose tightening may cause a fall of the unit, short circuits, or malfunctions. Overtightening may damage the screws and/or the unit, resulting in a fall of the unit, short circuits or malfunctions.

CAUTION

WARNING

CAUTION

WARNING

CAUTION

WARNING

CAUTION

[STARTUP AND MAINTENANCE PRECAUTIONS]

[DISPOSAL PRECAUTIONS]

[TRANSPORTATION PRECAUTIONS]

Manual The following shows manuals relevant to this product.

For relevant manuals, refer to the PDF manuals stored in the DVD-ROM for the drawing software used.

Compliance with the EMC and Low Voltage Directives To configure a system meeting the requirements of the EMC and Low Voltage Directives when incorporating the Mitsubishi GOT (EMC and Low Voltage Directives compliant) into other machinery or equipment, refer to "EMC AND LOW VOLTAGE DIRECTIVES" of the General Description included with the GOT used. The CE mark, indicating compliance with the EMC and Low Voltage Directives, is printed on the rating plate of the GOT.

Compliance with the new China RoHS directive GOT

6 6

SJ/T11364

Make sure to touch the grounded metal to discharge the electricity charged in the body, etc., before touching the unit. Failure to do so may cause a failure or malfunctions of the unit.

Dispose of this product as industrial waste.

Make sure to transport the GOT main unit and/or relevant unit(s) in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of the User's Manual for the GOT used, as they are precision devices. Failure to do so may cause the unit to fail. Check if the unit operates correctly after transportation.

When fumigants that contain halogen materials such as fluorine, chlorine, bromine, and iodine are used for disinfecting and protecting wooden packaging from insects, they cause malfunction when entering our products.Please take necessary precautions to ensure that remaining materials from fumigant do not enter our products, or treat packaging with methods other than fumigation (heat method).Additionally, disinfect and protect wood from insects before packing products.

Detailed Manuals

Manual name Manual number (Model code)

GOT2000 Series User's Manual (Hardware) (Sold separately)

SH-081194ENG (1D7MJ5)

GOT2000 Series Connection Manual (Mitsubishi Products) For GT Works3 Version1

(Sold Separately)

SH-081197ENG (1D7MJ8)

GT16 User's Manual (Hardware) (Sold separately)

SH-080928ENG (1D7MD3)

GT15 User's Manual (Sold separately)

SH-080528ENG (1D7M23)

GOT1000 Series Connection Manual (Mitsubishi Products) for GT Works3

(Sold separately)

SH-080868ENG (1D7MC2)

Relevant Manuals

Note: This symbol mark is for China only.

Pb

Hg

Cd

Cr(VI)

PBB

PBDE

CAUTION

CAUTION

CAUTION

: GB/T26572

: GB/T26572

Referenced Standard: GB/T15969.2 (Requirement of Chinese standardized law)

Packing List After unpacking the box, check that the following products are included.

1. OVERVIEW This user's manual describes the GOT2000/GOT1000 series CC-Link IE Field Network communication unit (hereinafter referred to as the CC-Link IE communication unit). The CC-Link IE communication unit allows the GOT2000 or GOT1000 series to function as an intelligent device station on the CC-Link IE Field Network. Refer to the User's Manual for the GOT used for GOT to which this unit can be installed. When using the CC-Link IE Field Network connection, make the communication setting to perform communication with programmable controllers. For the details of the CC-Link IE Field Network connection, refer to the GOT2000 or GOT1000 Series Connection Manual (Mitsubishi Products).

2. SPECIFICATIONS The general specifications of the CC-Link IE communication unit are the same as those of the GOT. For the general specifications of the GOT, refer to the User's Manual for the GOT used. The performance specifications of the CC-Link IE communication unit are indicated below.

Model Product Quantity

GT15-J71GF13-T2

CC-Link IE Field Network communication unit 1 Mounting screw set (4 screws, 4 stickers) 1 Extension interface relay board 1 GOT2000/GOT1000 Series CC-Link IE Field Network Communication Unit User's Manual (This manual)

1

Item Specifications

Max. link device points per network

RWw 8K points (8192 points, 16Kbytes) RWr 8K points (8192 points, 16Kbytes) RX 16K points (16384 points, 2Kbytes) RY 16K points (16384 points, 2Kbytes)

Max. link device points per GOT

RWw 1K points (1024 points, 2Kbytes) RWr 1K points (1024 points, 2Kbytes) RX 2K points (2048 points, 256 bytes) RY 2K points (2048 points, 256 bytes)

Max. sending points per GOT

RWw Online (Nomal mode):1024 points, 2Kbytes Online (High-speed mode):256 points, 512 bytes

RY 2K points (2048 points, 256 bytes)

Transmis sion specifica tions

Communication speed 1Gbps

Connection cable

An Ethernet cable that meets the 1000BASE-T standard: Category 5e or higher (double shielded, STP), straight cable

Max. station-to- station distance

100m (conform to ANSI/TIA/EIA-568-B (category 5e))

Overall cable distance

In line connection: 12000m (when connecting 1 master station and 120 slave stations) In star connection: depends on the system configuration In ring connection: 12100m (when connecting 1 master station and 120 slave stations)

Max. number of cascaded stages

20 stages

Transmission path

Line type, star type (line and star mixed type is also enabled) or ring type

Max. number of connectable stations per network 120

Max. number of networks 239 Communication method Token passing method Max. transient transmission capacity 1920 bytes

Internal current consumption 0.96A Weight 0.26kg (0.57lb)

3. PART NAMES AND EXTERNAL DIMENSIONS

3.1 CC-Link IE Communication Unit

Dimensions of X when the CC-Link IE communication unit is mounted to the GOT. GOT GT27 GT25 GT16 GT15

15" 37 (1.46) - 33.5 (1.32) 35 (1.38) 12.1" 37 (1.46) 37 (1.46) 32 (1.26) 32 (1.26) 10.4" 37 (1.46) 37 (1.46) 35 (1.38) 35 (1.38) 8.4" 37 (1.46) 37 (1.46) 37 (1.46) 37 (1.46) 5.7" 37 (1.46) - 37 (1.46) 37 (1.46)

Unit : mm (inch)

No. Name Description

1) Indicator LED Indicates the operating status of the CC-Link IE communication unit.

2) Connector (PORT1 side) Connector for connecting an Ethernet cable

(There is no restrictions for the connecting order at wiring of PORT1 and PORT2 side connectors)3) Connector

(PORT2 side)

4) Interface connector Extension connector installed to a front extension unit or the GOT

5) Extension connector

Extension connector to which a back extension unit is installed

6) Board fixing screw Screws for fixing the extension interface relay board

7) Mounting screw Mounting screws fixed with a front extension unit or the GOT

8) Rating plate -

133 (5.24) 3

11 1

(4 .3

7)

GOT

X6 (0

.2 4) 2.5

(0.10)

2 (0.08)

35 (1

.3 8)

19 (0

.7 5)

44 (1

.7 3)

21 (0.83)

24 (0.94)

1)

4)

7)

7)

2)

8)

6)

5)

Unit : mm (inch)

3)

98 (3

.8 6)

3 (0

.1 2)

(0.12)

main unit

(1) Indicator LED

(2) LED on connector

3.2 Extension Interface Relay Board

4. INSTALLATION PROCEDURE

The installation procedure for the CC-Link IE communication unit is explained using the GT1685.

1) Power off the GOT. 2) Remove two extension unit covers of the GOT. 3) Attach the extension interface relay board to the extension interface 2 on the

GOT. After the installation, detach the connector cover from the extension interface relay board. For the following GOT types, the extension interface relay board is not needed. GT1655, GT155 of the GOT1000 series GT27, GT25 of the GOT2000 series

A LED indicates the status of the CC-Link IE communication unit and the communication status. If any communication error occurs, specify the error cause by the [NETWK unit status display] screen of the GOT utility. Refer to the User's Manual for the GOT used for details on the [NETWK unit status display] screen.

A LED indicates the link status of the CC-Link IE communication unit and the reception status.

LED name Status Description

RUN On The unit is in a normal status. Off Hardware failure or WDT error

SD On Sending data Off Not sending data

RD On Receiving data Off Not receiving data

ERR. On

Any of the following errors occurs. An error is detected on all stations. Station number duplication occurs in the network. The network parameters are corrupted. The network parameters (including the reserved station setting, the number of connected devices, and the network number) differ from the actual connection of the devices.

Blink A data link error station is detected. Off Normal operation

LINK LED

L ER LED LED name Status Description

L ER Off No error

On Target port frame loss

LINK Off Link down

On Link up

64 (2.52)

21 .5

(0 .8

5) 41

(1 .6

1)

Unit : mm (inch)

4) Fit the CC-Link IE communication unit in the GOT case.

5) Fix the CC-Link IE communication unit by tightening its mounting screws (4 places) with a tightening torgue of 0.36 to 0.48 Nm.

6) Fix the CC-Link IE communication unit by tightening two board fixing screws with a tightening torque of 0.36 to 0.48 Nm.

7) When installing an extension unit on the unit that has been installed, remove the connector cover and the stickers. When not installing an extension unit on the unit that has been installed, in order to avoid receiving electrostatic, stick accessory stickers to cover the top of mounting screws (4 places). Keep the connector cover fixed. Keep the accessory sticker stuck.

5. PRECAUTIONS FOR WIRING CABLES

1) Confirm the followings on the Ethernet cable used. If there is no disconnection If there is no short circuit If there is no connection problem at the connectors

2) Do not use Ethernet cables with broken latches. Using Ethernet cables with broken latches may cause cable disconnection or malfunction.

3) When connecting or removing the Ethernet cables to/from the unit, hold the Ethernet cable connector securely with the hands.

4) Connect the Ethernet cable connector and unit connector securely until you hear a click sound.

5) For connecting Ethernet cables to the unit, the bending radius of the cables must be within the specified range. For details, check the specifications of the cables to be used.

6) When installing the Ethernet cable, do not touch the cable core of the Ethernet cable connector or unit connector, or let dirt or dust collect on it. If oil from the hands, dirt or dust should adhere to the core, the transmission loss will increase, causing a malfunction in the data link.

7) Wire the connector to the Ethernet cable correctly. After wiring, perform a loop test or station-to-station test or others to confirm if the setting and wiring of CC-Link IE communication unit have been done properly.

8) For connectors to which Ethernet cables are not connected, keep the accessory connector covers attached, as to avoid the invasion of dirt and dust.

Point Remove the screws that fixes the extension interface relay board before removing the unit. (Above 6) )

4) 3)

Remove the connector cover.

2)

5) 6)

Connector cover Accessory sticker

Sticker

Accessory sticker

Connector cover

Warranty Mitsubishi Electric will not be held liable for damage caused by factors found not to be the cause of Mitsubishi Electric; machine damage or lost profits caused by faults in the Mitsubishi Electric products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi Electric; damages to products other than Mitsubishi Electric products; and to other duties.

For safe use This product has been manufactured as a general-purpose part for

general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.

Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi Electric.

This product has been manufactured under strict quality control. However, when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN

When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission.

Specifications subject to change without notice. Printed in Japan, November 2020.

Country/Region Sales office/Tel USA Mitsubishi Electric Automation, Inc.

500 Corporate Woods Parkway, Vernon Hills, IL 60061, U.S.A. Tel: +1-847-478-2100

Brazil Mitsubishi Electric do Brasil Comercio e Servicos Ltda. Avenida Adelino Cardana, 293, 21 andar, Bethaville, Barueri SP, Brazil Tel: +55-11-4689-3000

Mexico Mitsubishi Electric Automation, Inc. Mexico Branch Boulevard Miguel de Cervantes Saavedra 301, Torre Norte Piso 5, Ampliacion Granada, Miguel Hidalgo, Ciudad de Mexico, Mexico, C.P.11520 Tel: +52-55-3067-7512

Germany Mitsubishi Electric Europe B.V. German Branch Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany Tel: +49-2102-486-0

UK Mitsubishi Electric Europe B.V. UK Branch Travellers Lane, UK-Hatfield, Hertfordshire, AL10 8XB, U.K. Tel: +44-1707-28-8780

Italy Mitsubishi Electric Europe B.V. Italian Branch Centro Direzionale Colleoni - Palazzo Sirio, Viale Colleoni 7, 20864 Agrate Brianza (MB), Italy Tel: +39-039-60531

Spain Mitsubishi Electric Europe B.V. Spanish Branch Carretera de Rubi, 76-80-Apdo. 420, E-08190 Sant Cugat del Valles (Barcelona), Spain Tel: +34-935-65-3131

France Mitsubishi Electric Europe B.V. French Branch 25, Boulevard des Bouvets, 92741 Nanterre Cedex, France Tel: +33-1-55-68-55-68

Czech Mitsubishi Electric Europe B.V. Czech Branch Pekarska 621/7, 155 00 Praha 5, Czech Republic Tel: +420-255 719 200

Turkey Mitsubishi Electric Turkey A.S. Umraniye Branch Serifali Mahallesi Nutuk Sokak No:5, TR-34775 Umraniye / Istanbul, Turkey Tel: +90-216-526-3990

Poland Mitsubishi Electric Europe B.V. Polish Branch ul. Krakowska 48, 32-083 Balice, Poland Tel: +48-12-347-65-00

Russia Mitsubishi Electric (Russia) LLC St. Petersburg Branch Piskarevsky pr. 2, bld 2, lit "Sch", BC "Benua", office 720; 195027 St. Petersburg, Russia Tel: +7-812-633-3497

South Africa Adroit Technologies 20 Waterford Office Park, 189 Witkoppen Road, Fourways, South Africa Tel: +27-11-658-8100

China Mitsubishi Electric Automation (China) Ltd. Mitsubishi Electric Automation Center, No.1386 Hongqiao Road, Shanghai, China Tel: +86-21-2322-3030

Taiwan SETSUYO ENTERPRISE CO., LTD. 6F, No.105, Wugong 3rd Road, Wugu District, New Taipei City 24889, Taiwan Tel: +886-2-2299-2499

Korea Mitsubishi Electric Automation Korea Co., Ltd. 7F to 9F, Gangseo Hangang Xi-tower A, 401, Yangcheon-ro, Gangseo-Gu, Seoul 07528, Korea Tel: +82-2-3660-9569

Singapore Mitsubishi Electric Asia Pte. Ltd. 307 Alexandra Road, Mitsubishi Electric Building, Singapore 159943 Tel: +65-6473-2308

Thailand Mitsubishi Electric Factory Automation (Thailand) Co., Ltd. 12th Floor, SV.City Building, Office Tower 1, No. 896/19 and 20 Rama 3 Road, Kwaeng Bangpongpang, Khet Yannawa, Bangkok 10120, Thailand Tel: +66-2682-6522 to 31

Indonesia PT. Mitsubishi Electric Indonesia Gedung Jaya 8th Floor, JL. MH. Thamrin No.12, Jakarta Pusat 10340, Indonesia Tel: +62-21 3192-6461

Vietnam Mitsubishi Electric Vietnam Compa

Manualsnet FAQs

If you want to find out how the GOT1000 Mitsubishi works, you can view and download the Mitsubishi GOT1000 GT15-J71GF13-T2 Field Network User's Manual on the Manualsnet website.

Yes, we have the User's Manual for Mitsubishi GOT1000 as well as other Mitsubishi manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The User's Manual should include all the details that are needed to use a Mitsubishi GOT1000. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Mitsubishi GOT1000 GT15-J71GF13-T2 Field Network User's Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Mitsubishi GOT1000 GT15-J71GF13-T2 Field Network User's Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Mitsubishi GOT1000 GT15-J71GF13-T2 Field Network User's Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Mitsubishi GOT1000 GT15-J71GF13-T2 Field Network User's Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Mitsubishi GOT1000 GT15-J71GF13-T2 Field Network User's Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.