GOT2000 Series Ethernet communication unit

Prior to use, please read both this manual and detailed manual thoroughly to fully understand the product.

MODEL GT25-J71E71-U-JE

MODEL CODE

1D7MR6

IB(NA)-0800562-E(2107)MEE

SAFETY PRECAUTIONS (Always read these precautions before using this equipment.)

Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly. The precautions given in this manual are concerned with this product. In this manual, the safety precautions are ranked as "WARNING" and "CAUTION".

Note that the CAUTION level may lead to a serious accident according to the circumstances. Always follow the precautions of both levels because they are important to personal safety. Please save this manual to make it accessible when required and always forward it to the end user.

[DESIGN PRECAUTIONS]

Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.

Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.

If a communication fails in data link, the faulty station holds the data link data generated before the communication error. Create an interlock circuit in the sequence program using the communication status information in order that the system will operate safely. Failure to do so may cause mis-outputs or malfunctions, resulting in accidents. Check the faulty station and the operation status during communication error by referring to the relevant manuals.

Some failures of cable or the unit may cause the GOT to keep the outputs on or off. Create an external circuit for monitoring output signals that may lead to serious accidents. Failure to do so may cause mis-outputs or malfunctions, resulting in accidents.

WARNING

CAUTION

WARNING

[DESIGN PRECAUTIONS]

[INSTALLATION PRECAUTIONS]

[WIRING PRECAUTIONS]

[STARTUP AND MAINTENANCE PRECAUTIONS]

If a communication error (including cable disconnection) occurs during monitoring, the communication between the GOT and programmable controller CPU may be interrupted and the GOT may be inoperative. When configuring a system including the GOT, the possibility of GOT communication error must be considered; make sure the operation significant for the system will be performed by switches on devices other than the GOT. Failure to do so may cause mis-outputs or malfunctions, resulting in accidents.

To maintain the security (confidentiality, integrity, and availability) of the GOT and the system against unauthorized access, DoS*1 attacks, computer viruses, and other cyberattacks from unreliable networks and devices via network, take appropriate measures such as firewalls, virtual private networks (VPNs), and antivirus solutions. Mitsubishi Electric shall have no responsibility or liability for any problems involving GOT trouble and system trouble by unauthorized access, DoS attacks, computer viruses, and other cyberattacks. *1 DoS: A denial-of-service (DoS) attack disrupts services by overloading systems or exploiting vulnerabilities, resulting in a denial-of-service (DoS) state.

Do not bunch the control wires or cables with the main circuit or power wires, or lay them close to each other. As a guide, separate the lines by a distance of at least 100mm (3.94 inches) otherwise malfunctions may occur due to noise.

Be sure to shut off all phases of the external power supply used by the system before mounting or removing this unit to/from the GOT. Not doing so can cause a unit failure or malfunction.

Before connecting the Bus connection cable to this unit, always shut off GOT power and PLC CPU power externally in all phases.Not doing so can cause a malfunction.

Use this unit in the environment that satisfies the general specifications described in the User's Manual for the GOT used. Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration.

Do not drop the unit or subject it to string shock. A unit damage may result.

When mounting this unit on the GOT, fit it to the connection interface of the GOT, and tighten the mounting screws in the specified torque range (0.36Nm to 0.48Nm) with a Phillips-head screwdriver No. 2. Undertightening can cause a drop, failure or malfunction. Overtightening can cause a drop, failure or malfunction due to screw or unit damage.

Be sure to shut off all phases of the external power supply used by the system before wiring. Failure to do so may result in an electric shock, product damage or malfunctions.

Use crimp-contact, pressure-displacement or soldering to wire the connectors for external connections properly using the manufacturer-specified tools. If the connection is incomplete, it may cause the module to short circuit, catch fire, or malfunction.

Exercise care to avoid foreign matter such as chips and wire offcuts entering the unit. Not doing so can cause a fire, failure or malfunction.

Make sure to securely connect the cable to the connector of unit. Incorrect connection may cause malfunctions.

Before starting cleaning, always shut off GOT power externally in all phases. Not doing so can cause a unit failure or malfunction. Undertightening can cause the GOT to drop, short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit.

Do not disassemble or modify the unit and the CF card. Doing so can cause a failure, malfunction, injury or fire.

Do not touch the conductive areas and electronic parts of this unit directly. Doing so can cause a unit malfunction or failure.

Always secure the cables connected to the unit, e.g. run them in conduits or clamp them. Not doing so can cause unit or cable damage due to dangling, moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault.

Do not hold the cable part when unplugging any cable connected to the unit. Doing so can cause unit or cable damage or a malfunction due to a cable contact fault.

Always make sure to touch the grounded metal to discharge the electricity charged in the body, etc., before touching the unit. Failure to do so may cause a failure or malfunctions of the unit.

WARNING

CAUTION

WARNING

CAUTION

WARNING

CAUTION

WARNING

CAUTION

[DISPOSAL PRECAUTIONS]

[TRANSPORTATION PRECAUTIONS]

Manual The following shows manuals relevant to this product.

For detailed manuals or relevant manuals, refer to the e-Manual or the PDF manuals stored in the DVD-ROM for the drawing software used.

The latest manuals are also available from MITSUBISHI ELECTRIC FA Global

Website (www.MitsubishiElectric.com/fa).

Compliance with the EMC and Low Voltage Directives To configure a system meeting the requirements of the EMC and Low Voltage Directives when incorporating the Mitsubishi GOT (EMC and Low Voltage Directives compliant) into other machinery or equipment, refer to "EMC AND LOW VOLTAGE DIRECTIVES" of the General Description included with the GOT used. The CE mark, indicating compliance with the EMC and Low Voltage Directives, is printed on the rating plate of the GOT.

Compliance with the new China RoHS directive GOT

6 6

SJ/T11364 : GB/T26572

: GB/T26572

Referenced Standard: GB/T15969.2 (Requirement of Chinese standardized law)

Dispose of this product as industrial waste.

Make sure to transport the GOT main unit and/or relevant unit(s) in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of the GOT2000 Series User's Manual (Hardware), as they are precision devices. Failure to do so may cause the unit to fail. Check if the unit operates correctly after transportation.

When fumigants that contain halogen materials such as fluorine, chlorine, bromine, and iodine are used for disinfecting and protecting wooden packaging from insects, they cause malfunction when entering our products. Please take necessary precautions to ensure that remaining materials from fumigant do not enter our products, or treat packaging with methods other than fumigation (heat method). Additionally, disinfect and protect wood from insects before packing products.

Manual name Manual number (Model code)

GOT2000 Series User's Manual (Hardware) (Sold separately)

SH-081194ENG (1D7MJ5)

GT Designer3 (GOT2000) Screen Design Manual (Sold separately)

SH-081220ENG (1D7ML9)

GOT2000 Series Connection Manual (Mitsubishi Products) For GT Works3 Version1 (Sold separately)

SH-081197ENG (1D7MJ8)

GOT2000 Series Connection Manual (Non- Mitsubishi Products 1) For GT Works3 Version1

SH-081198ENG

GOT2000 Series Connection Manual (Non- Mitsubishi Products 2) For GT Works3 Version1

SH-081199ENG

GOT2000 Series Connection Manual (Microcomputers, MODBUS/Fieldbus Products, Peripherals) For GT Works3 Version1

SH-081200ENG

Note: This symbol mark is for China only.

Pb

Hg

Cd

Cr(VI)

PBB

PBDE

CAUTION

CAUTION

Packing List After unpacking the box, check that the following products are included.

1. OVERVIEW

This user's manual describes the GOT2000 series Ethernet communication unit (hereinafter referred to as the Ethernet communication unit) The Ethernet communication unit is required for some operations with the GOT, such as the Ethernet connection and the gateway function. For the applicable GOTs, refer to the GOT2000 Series User's Manual (Hardware). To communicate with a PLC by using the Ethernet connection, configure the controller settings. For the controller settings, refer to the GT Designer3 (GOT2000) Screen Design Manual. For the details of the system configuration and communication driver for the Ethernet connection, refer to the relevant GOT2000 Series Connection Manual according to the controller used.

2. SPECIFICATIONS

2.1 Performance Specifications The performance specifications of the Ethernet communication unit are indicated below. The general specifications of the Ethernet communication unit are the same as those of the GOT. Refer to GOT2000 Series User's Manual (Hardware) used for the general specifications of the GOT.

*1 Maximum number of connectable nodes when a repeater hub is used For the details, refer to the manual of Ethernet module of connected PLC.

*2 This depends on the specifications of the Ethernet network system to which the GOT is connected. For the details, refer to the manual of Ethernet module of connected PLC.

*3 If multiple network equipments (including GOT) are connected within a segment, the network load would increase. In such condition, the communication performance between GOT and PLC may be declined. The decline of the communication performance may be improved by the following measures. Using switching hubs. Reducing the number of monitoring devices of the GOT.

2.2 Supported version When using the Ethernet communication unit, use the following software and BootOS.

For how to check and upgrade the BootOS version, refer to the following manuals. GT Designer3 (GOT2000) Screen Design Manual

GOT2000 Series User's Manual (Utility)

Model Product Quantity

GT25- J71E71-100

GOT2000 Series Ethernet communication unit 1

Mounting screw set (2 screws (26 mm), 2 stickers) 1

GOT2000 Series Ethernet communication unit User's Manual (This manual)

1

Item Specification

Transmission specifications

Data transfer method 100BASE-TX 10BASE-T

Interface RJ45 (AUTO MDI/MDI-X)

Transmission method Base band Base band

Maximum node to mode distance

200m 200m

Maximum segment length

100m 100m

Maximum number of cascade connection*1

2 steps 4 steps

Number of units mounted to GOT Only 1 unit can be mounted to the extension unit interface.

Connecting condition

Number of GOTs connected

128 (Recommend 16 or less)*2*3

GOT placing distance 100m*2

Internal current consumption (5VDC) 0.14A

Weight 0.07kg (0.15lb)

Item Supported version

Screen design software GT Designer3 Version 1.160S or later

BootOS Z or later

2.3 Specifications of the related devices Use the connection cable and the hub which meet the IEEE802.3 100BASE-TX/ 10BASE-T standard.

3. PART NAMES AND EXTERNAL DIMENSIONS

Item Specifications

100BASE-TX 10BASE-T

Cable

Category 5 or higher (shielded, STP) straight cable, category 5 or higher (shielded, STP) cross cable

Category 3 or higher (shielded, STP) straight cable, category 3 or higher (UTP) straight cable, category 3 or higher (shielded, STP) cross cable, category 3 or higher (UTP) cross cable

Connector RJ45jack RJ45jack

Hub 100Mbps hub 10Mbps hub

See the "List of valid devices applicable for GOT2000 series" GOT-A-0064) for

information about models whose operations have been confirmed. For technical documents, please contact your local Mitsubishi representative. When using any model not mentioned in the "List of valid devices applicable for GOT2000 series", the model may not work normally. If you need the Technical News, consult your local Mitsubishi representative or branch office.

No. Name Description

1) Mounting screw Mounting screws fixed with a front extension unit or GOT

2) Interface connector Extension connector installed to a front extension unit or the GOT

3) Extension connector Extension connector to which a back extension unit is installed

4) Ethernet connector Connector to which Ethernet cable is connected

5) SPEED LED ON : Communicating at 100 Mbps OFF: Communicating at 10 Mbps or disconnected

6) SD/RD LED ON : Data sent or received OFF: Data not sent or received

7) Rating plate -

GOT main unit

1)

7)

4)

5) 6)

3) 2)

7 (0

.2 8)

97 .5

(3 .8

4) 4.

5 (0

.1 8)

63 (2.48) 27.5 (1.08)

3 (0.12)

31.5 (1.24)

20 (0.79)

8. 5

(0 .3

3)

21 .5

(0 .8

5)

unit: mm (inch)

4. INSTALLATION AND REMOVAL PROCEDURE

4.1 Installation The following shows how to install the Ethernet communication unit on GT2712 as an example.

1) Turn off the GOT. 2) Pull up the hooks of the GOT extension unit cover to remove the cover.

3) Mount the Ethernet communication unit on the extension interface of the GOT. Tighten two mounting screws (26 mm) with a torque of 0.36 Nm to 0.48 Nm to fix the unit.

4) Attach the accessory stickers, or remove the stickers from the Ethernet communication unit as necessary When connecting no extension unit to the extension connector: Leave the stickers on the Ethernet communication unit. Cover two mounting screws with the accessory stickers to avoid static electricity. When connecting an extension unit to the extension connector: Remove the stickers from the Ethernet communication unit, and connect the extension unit. The accessory stickers are not used.

4.2 Removal Remove the Ethernet communication unit in the reverse of the installation procedure.

Point

(1) Grounding work for the 100BASE-TX and 10BASE-T requires appropriate safety measures. Consult professionals for work details including terminal of connection cables and other plant work such as laying of main cables.

(2) If you remove the Ethernet communication unit, detach it from specified direction (shown PULL) so as not to break a connector.

Ethernet is a registered trademark of Xerox Corporation in the United States. Other business or product names mentioned herein are a trademark or registered trademark of each company.

Sticker

Accessory stickers

Sticker

Warranty Mitsubishi Electric will not be held liable for damage caused by factors found not to be the cause of Mitsubishi Electric; machine damage or lost profits caused by faults in the Mitsubishi Electric products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi Electric; damages to products other than Mitsubishi Electric products; and to other duties.

For safe use This product has been manufactured as a general-purpose part for

general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.

Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi Electric.

This product has been manufactured under strict quality control. However, when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.

Country/Region Sales office/Tel

USA Mitsubishi Electric Automation, Inc. 500 Corporate Woods Parkway, Vernon Hills, IL 60061, U.S.A. Tel: +1-847-478-2100

Brazil Mitsubishi Electric do Brasil Comercio e Servicos Ltda. Avenida Adelino Cardana, 293, 21 andar, Bethaville, Barueri SP, Brazil Tel: +55-11-4689-3000

Mexico Mitsubishi Electric Automation, Inc. Mexico Branch Boulevard Miguel de Cervantes Saavedra 301, Torre Norte Piso 5, Ampliacion Granada, Miguel Hidalgo, Ciudad de Mexico, Mexico, C.P.11520 Tel: +52-55-3067-7512

Germany Mitsubishi Electric Europe B.V. German Branch Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany Tel: +49-2102-486-0

UK Mitsubishi Electric Europe B.V. UK Branch Travellers Lane, UK-Hatfield, Hertfordshire, AL10 8XB, U.K. Tel: +44-1707-28-8780

Italy Mitsubishi Electric Europe B.V. Italian Branch Centro Direzionale Colleoni - Palazzo Sirio, Viale Colleoni 7, 20864 Agrate Brianza (MB), Italy Tel: +39-039-60531

Spain Mitsubishi Electric Europe B.V. Spanish Branch Carretera de Rubi, 76-80-Apdo. 420, E-08190 Sant Cugat del Valles (Barcelona), Spain Tel: +34-935-65-3131

France Mitsubishi Electric Europe B.V. French Branch 25, Boulevard des Bouvets, 92741 Nanterre Cedex, France Tel: +33-1-55-68-55-68

Czech Mitsubishi Electric Europe B.V. Czech Branch Pekarska 621/7, 155 00 Praha 5, Czech Republic Tel: +420-255 719 200

Turkey Mitsubishi Electric Turkey A.S. Umraniye Branch Serifali Mahallesi Nutuk Sokak No:5, TR-34775 Umraniye / Istanbul, Turkey Tel: +90-216-526-3990

Poland Mitsubishi Electric Europe B.V. Polish Branch ul. Krakowska 48, 32-083 Balice, Poland Tel: +48-12-347-65-00

Russia Mitsubishi Electric (Russia) LLC St. Petersburg Branch Piskarevsky pr. 2, bld 2, lit "Sch", BC "Benua", office 720; 195027 St. Petersburg, Russia Tel: +7-812-633-3497

South Africa Adroit Technologies 20 Waterford Office Park, 189 Witkoppen Road, Fourways, South Africa Tel: +27-11-658-8100

China Mitsubishi Electric Automation (China) Ltd. Mitsubishi Electric Automation Center, No.1386 Hongqiao Road, Shanghai, China Tel: +86-21-2322-3030

Taiwan SETSUYO ENTERPRISE CO., LTD. 6F, No.105, Wugong 3rd Road, Wugu District, New Taipei City 24889, Taiwan Tel: +886-2-2299-2499

Korea Mitsubishi Electric Automation Korea Co., Ltd. 7F to 9F, Gangseo Hangang Xi-tower A, 401, Yangcheon-ro, Gangseo-Gu, Seoul 07528, Korea Tel: +82-2-3660-9569

Singapore Mitsubishi Electric Asia Pte. Ltd. 307 Alexandra Road, Mitsubishi Electric Building, Singapore 159943 Tel: +65-6473-2308

Thailand Mitsubishi Electric Factory Automation (Thailand) Co., Ltd. 12th Floor, SV.City Building, Office Tower 1, No. 896/19 and 20 Rama 3 Road, Kwaeng Bangpongpang, Khet Yannawa, Bangkok 10120, Thailand Tel: +66-2682-6522 to 31

Indonesia PT. Mitsubishi Electric Indonesia Gedung Jaya 8th Floor, JL. MH. Thamrin No.12, Jakarta Pusat 10340, Indonesia Tel: +62-21 3192-6461

Vietnam Mitsubishi Electric Vietnam Company Limited 11th & 12th Floor, Viettel Tower B, 285 Cach Mang Thang 8 Street, Ward 12, District 10, Ho Chi Minh City, Vietnam. Tel: +84-28-3910-5945

India Mitsubishi Electric India Pvt. Ltd. Pune Branch Emerald House, EL-3, J Block, M.I.D.C., Bhosari, Pune - 411026, Maharashtra, India Tel: +91-20-2710-2000

Australia MITSUBISHI ELECTRIC AUSTRALIA PTY. LTD. 348 Victoria Road, P.O. Box 11, Rydalmere, N.S.W 2116, Australia Tel: +61-2-9684-7777

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN

When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission.

Specifications subject to change without notice. Printed

Manualsnet FAQs

If you want to find out how the GOT2000 Mitsubishi works, you can view and download the Mitsubishi GOT2000 GT25-J71E71-U-JE Ethernet User's Manual on the Manualsnet website.

Yes, we have the User's Manual for Mitsubishi GOT2000 as well as other Mitsubishi manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The User's Manual should include all the details that are needed to use a Mitsubishi GOT2000. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Mitsubishi GOT2000 GT25-J71E71-U-JE Ethernet User's Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Mitsubishi GOT2000 GT25-J71E71-U-JE Ethernet User's Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Mitsubishi GOT2000 GT25-J71E71-U-JE Ethernet User's Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Mitsubishi GOT2000 GT25-J71E71-U-JE Ethernet User's Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Mitsubishi GOT2000 GT25-J71E71-U-JE Ethernet User's Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.