Mitsubishi GOT1000 GT15-4-U Communication Unit User's Manual PDF

1 of 1
1 of 1

Summary of Content for Mitsubishi GOT1000 GT15-4-U Communication Unit User's Manual PDF

User's Manual GT15-RS2-9P GT15-RS4-9S GT15-RS4-TE

Thank you for choosing Mitsubishi Electric Graphic Operation Terminal (GOT).

2005 MITSUBISHI ELECTRIC CORPORATION

GOT2000/GOT1000 Series Serial Communication Unit

Prior to use, please read both this manual and detailed manual thoroughly to fully understand the product.

MODEL GT15-RS2/4-U

MODEL CODE

1D7M40

IB(NA)-0800325-M(1806)MEE

SAFETY PRECAUTIONS (Always read these precautions before using this equipment.)

Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly. The precautions given in this manual are concerned with this prod- uct. In this manual, the safety precautions are ranked as "WARNING" and "CAUTION".

Note that the CAUTION level may lead to a serious accident according to the circumstances. Always follow the precautions of both levels because they are import- ant to personal safety. Please save this manual to make it accessible when required and always forward it to the end user. [INSTALLATION PRECAUTIONS]

[INSTALLATION PRECAUTIONS]

Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.

Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.

Be sure to shut off all phases of the external power supply used by the system before mounting or removing this unit to/from the GOT. Not doing so can cause a unit failure or malfunction.

Before connecting the Bus connection cable to this unit, always shut off GOT power and PLC CPU power externally in all phases.Not doing so can cause a malfunction.

Use this unit in the environment that satisfies the general specifications described in the User's Manual for the GOT used. Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration.

WARNING

CAUTION

WARNING

CAUTION

[DESIGN PRECAUTIONS]

[WIRING PRECAUTIONS]

[STARTUP AND MAINTENANCE PRECAUTIONS]

[DISPOSAL PRECAUTIONS]

[TRANSPORTATION PRECAUTIONS]

When installing this unit to the GOT, fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range.Undertightening can cause a drop, failure or malfunction.Overtightening can cause a drop, failure or malfunction due to screw or unit damage.

Do not bunch the control wires or communication cables with the main circuit or power wires, or lay them close to each other. As a guide, separate the lines by a distance of at least 100mm (3.94 inches) otherwise malfunctions may occur due to noise.

Be sure to shut off all phases of the external power supply used by the system before wiring.Failure to do so may result in an electric shock, product damage or malfunctions.

Use crimp-contact, pressure-displacement or soldering to wire the connectors for external connections properly using the manufacturer-specified tools.If the connection is incomplete, it may cause the module to short circuit, catch fire, or malfunction.

Connect the connectors to the unit securely. Always secure the cables connected to the unit, e.g. run them in

conduits or clamp them.Not doing so can cause unit or cable damage due to dangling, moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault.

Before starting cleaning, always shut off GOT power externally in all phases. Not doing so can cause a unit failure or malfunction.

Do not disassemble or modify any unit. This will cause failure, malfunction, injuries, or fire.

Do not touch the conductive areas and electronic parts of this unit directly.Doing so can cause a unit malfunction or failure.

Exercise care to avoid foreign matter such as chips and wire offcuts entering the unit. Not doing so can cause a fire, failure or malfunction.

Do not hold the cable part when unplugging any cable connected to the unit. Doing so can cause unit or cable damage or a malfunction due to a cable contact fault.

Always make sure to touch the grounded metal to discharge the electricity charged in the body, etc., before touching the unit. Failure to do so may cause a failure or malfunctions of the unit.

Dispose of this product as industrial waste.

Make sure to transport the GOT main unit and/or relevant unit(s) in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of the User's Manual for the GOT used, as they are precision devices. Failure to do so may cause the unit to fail. Check if the unit operates correctly after transportation.

CAUTION

WARNING

WARNING

CAUTION

WARNING

CAUTION

CAUTION

CAUTION

Manual The following shows manuals relevant to this product.

For relevant manuals, refer to the PDF manuals stored in the DVD- ROM for the drawing software used.

Compliance with the EMC and Low Voltage Directives To configure a system meeting the requirements of the EMC and Low Voltage Directives when incorporating the Mitsubishi GOT (EMC and Low Voltage Directives compliant) into other machinery or equipment, refer to "EMC AND LOW VOLTAGE DIRECTIVES" of the General Description included with the GOT used. The CE mark, indicating compliance with the EMC and Low Voltage Directives, is printed on the rating plate of the GOT.

Compliance with the new China RoHS directive GOT

6 6

SJ/T11364 : GB/T26572

: GB/T26572

Referenced Standard: GB/T15969.2 (Requirement of Chinese standardized law)

Detailed Manuals

Manual name Manual number (Model code)

GOT2000 Series Users Manual (Hardware) (Sold separately)

SH-081194ENG (1D7MJ5)

GOT2000 Series Connection Manual (Mitsubishi Products) For GT Works3 Version1 (Sold separately)

SH-081197ENG (1D7MJ8)

GOT2000 Series Connection Manual (Non-Mitsubishi Products 1) For GT Works3 Version1 (Sold separately)

SH-081198ENG

GOT2000 Series Connection Manual (Non-Mitsubishi Products 2) For GT Works3 Version1 (Sold separately)

SH-081199ENG

GOT2000 Series Connection Manual (Microcomputer, MODBUS/Fieldbus Products, Peripherals) For GT Works3 Version1 (Sold separately)

SH-081200ENG

GT16 User's Manual (Hardware) (Sold separately)

SH-080928ENG (1D7MD3)

GT15 User's Manual (Sold separately)

SH-080528ENG (1D7M23)

GOT1000 Series Connection Manual (Mitsubishi Products) for GT Works3

(Sold separately)

SH-080868ENG (1D7MC2)

GOT1000 Series Connection Manual (Non-Mitsubishi Products 1) for GT Works3

(Sold separately)

SH-080869ENG (1D7MC3)

GOT1000 Series Connection Manual (Non-Mitsubishi Products 2) for GT Works3

(Sold separately)

SH-080870ENG (1D7MC4)

GOT1000 Series Connection Manual (Microcomputer, MODBUS Products, Peripherals) for GT Works3(Sold separately)

SH-080871ENG (1D7MC5)

Relevant Manuals

Note: This symbol mark is for China only.

Pb

Hg

Cd

Cr(VI)

PBB

PBDE

Packing List The following items are included.

* For handling of the ferrite core, refer to "For users intending to connect the GOT directly to a PLC using the RS-422 cable (GT01-C R4-25P)" provided with the product.

1. OVERVIEW This user's manual describes the GOT2000/GOT1000 series serial communication unit (hereinafter referred to as the serial communication unit). The serial communication unit is used when performing the serial communication between GOT and a FA device. For attachable GOTs, refer to the User's Manual for the GOT used.

2. SPECIFICATIONS

2.1 Performance Specifications The performance specifications of the serial communication unit are indicated below. The general specifications of the serial communication unit are the same as those of the GOT. Refer to the User's Manual for the GOT used for the general specifications of the GOT.

* The maximum transmission distance differs depending on the controller connected. For details, refer to the GOT2000 or GOT1000 series connection manual for GT Works3 that covers the controller used.

Select a serial communication unit according to the connection type. When using the serial communication, make the communication settings to perform communication between the GOT and PLC. Since the GT15-RS4-TE cannot control the signals (RS/CS), the unit cannot be connected to the PLC. For the details of the connection type, refer to the GOT2000 or GOT1000 series connection manual for GT Works3 that covers the controller used.

Model Product Quantity

GT15-RS2-9P

RS-232 serial communication unit 1

Mounting screw set (2 screws, 2 stickers) 1

GOT2000/GOT1000 Series Serial Communication Unit User's Manual (This manual)

1

GT15-RS4-9S

RS-422/485 serial communication unit 1

Mounting screw set (2 screws, 2 stickers) 1

Ferrite Core* 1

GOT2000/GOT1000 Series Serial Communication Unit User's Manual (This manual)

1

GT15-RS4-TE

RS-422/485 serial communication unit 1

Mounting screw set (2 screws, 2 stickers) 1

Terminal block socket 1

Plate type solderless terminal (For con- necting braided shield cable) 1

GOT2000/GOT1000 Series Serial Com- munication Unit User's Manual (This manual)

1

Item Specification

GT15-RS2-9P GT15-RS4-9S GT15-RS4-TE

Transmission method RS-232 compliant

RS-422/485 compliant

RS-422/485 compliant

Interface D-sub 9-pin (Male)

D-sub 9-pin (Female) Terminal block

Connector DDK make (17LE-23090- 27(D3CC))

DDK make (17LE-13090- 27(D3AC))

-

Transmission speed 115200/57600/38400/19200/9600/4800bps

Synchronous type Non-Synchronous type (Asynchronous type)

Error detection method Parity check, sum check

Maximum transmission distance 15m 1200m* 1200*

Imternal current consumption (5VDC) 0.29A 0.33A 0.3A

Weight 0.09kg (0.20lb)

When using serial communication unit, use a standard monitor OS and communication driver of GT Designer2 Version2.15R or later. With a standard monitor OS and communication driver of an older version, the GOT has cannot recognize the unit to perform monitoring.

2.2 Specifications of terminal block socket (For GT15-RS4-TE only)

3. PART NAMES AND EXTERNAL DIMENSIONS

(1) GT15-RS2-9P / PS4-9S

(2) GT15-RS4-TE

Dimensions of X when the serial communication unit is mounted to the GOT

Unit: mm (inch) (3) Back view (For GT15-RS4-9S / TE only)

Item Specifications

Screw tightening torque 0.20 to 0.25 [Nm]

Recommended driver DIN 5265: ISO 2380/2 compliant product DIN 5264: Product with the tip chrome-plated based on the ISO 2380/1 standard

Applicable wire size 0.08 to 1.5 [mm2]

GOT GT27 GT25 GT16 GT15

15, 23(0.91) - 19.5(0.77) 21(0.83)

12.1 23(0.91) 23(0.91) 18(0.71) 18(0.71)

10.4 23(0.91) 23(0.91) 21(0.83) 21(0.83)

8.4 23(0.91) 23(0.91) 23(0.91) 23(0.91)

5.7 23(0.91) - 23(0.91) 23(0.91)

No. Name Description

1) Mounting screw Mounting screws fixed with a front extension unit or GOT

2) Interface connector

Extension connector installed to a front extension unit or the GOT

3) Extension connector

Extension connector to which a back extension unit is installed

4) Serial communication connector

Connector for connecting a serial communication cable (For GT15-RS4-TE, the terminal block socket is connected.)

1)

7)

3)

4) X

98 (3

.8 6)

7 (0

.2 8)

11 2

(4 .4

1)

2.5 (0.10)

30 .5

(1 .2

)

21 .5

(0 .8

5)

3 (0.12)

GOT main unit63 (2.48)

2)

31.5 (1.24)

9 (0

.3 5)

Unit: mm (inch)

1)

7)

3)

4)

5)

X

GOT main unit

63 (2.48) 3 (0.12)

98 (3

.8 6)

1 2

(0 .4

7)

2.5 (0.10)

30 .5

(1 .2

) 21

.5 (0

.8 5)

11 7

(4 .6

1)

2)

29.5 (1.16)

11 .5

(0 .4

5)

Unit: mm (inch)

6)

(Expanded figure of part 6))

O N1

2

100 OHM

ON

SW1

4. INSTALLATION PROCEDURE The installation procedure for the serial communication unit is explained using the GT1575.

4.1 Serial communication unit installation The following figures show an example of the GT15-RS2-9P/RS4-9S installation.The installation of the GT15-RS4-TE follows the same procedure. (1) Power off the GOT. (2) Remove one extension unit cover of the GOT.

(3) Fit the serial communication unit in the GOT case.

(4) Fasten the serial communication unit by tightening its mounting screws (2 places) with tightening torque 0.36 to 0.48 Nm.

(5) When installing an extension unit on the unit that has been installed, remove the connector cover and the sticker. When not installing an extension unit on the unit that has been installed, in order to avoid receiving electrostatic, stick accessory stickers to cover the top of mounting screws (2 places). Keep the connector cover fixed. Keep the sticker stuck as it is.

5) Terminal block socket

Socket for connecting a serial communication cable to the serial communication connector

6) DIP switch (For GT15-RS4- 9S/TE only)

Switch to set terminating resistor.When using the built-in terminating resistor (100), turn both No. 1 and No. 2 switches on.When using the external terminating resistor, turn both No. 1 and No. 2 switches off.

7) Rating plate -

Point

If you remove the serial communication unit, detach it from specified direction (shown PULL) so as not to break a connector.

No. Name Description

Sticker

Accessory

stickers

Connector

cover

4.2 Terminal block socket installation (For GT15-RS4-TE only)

(1) Insert the terminal block socket in the serial communication unit.

(2) Fasten the terminal block by tightening the terminal block fixing screws (2 places) with the tightening torque of 0.20 to 0.25 Nm. (Expanded figure of part A)

4.3 Connecting the braided shield cable (For GT15-RS4-TE only)

When connecting the braided shield cable inside the RS-422/485 cable, use the plate type solderless terminal included with the product. Before connecting each cable inside the RS-422/485 cable to the terminal block, remove the cable sheath by 7mm(0.28 inches).

CAUTION

Always secure the cables connected to the unit, e.g. run them in conduits or clamp them.Not doing so can cause unit or cable damage due to dangling, moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault.

Point

When attaching or removing a communication cable to/from the terminal block socket, detach the terminal block socket from the connector. (When extension units are installed in multiple layers, the units do not have to be removed from the GOT main unit.)

Point

Tighten the terminal block wiring screws with the tightening torque of 0.5 to 0.6 Nm.

When using the plate type solderless terminal, be sure to insert the terminal in the horizontal direction toward the terminal block. The solderless terminal may come off when it is inserted in the vertical direction.

A

A terminal block fixing screw

7mm

10 FG

Braided shield cable

Plate type solderless terminal

(0.28inches)

Warranty Mitsubishi Electric will not be held liable for damage caused by factors found not to be the cause of Mitsubishi Electric; machine damage or lost profits caused by faults in the Mitsubishi Electric products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi Electric; damages to products other than Mitsubishi Electric products; and to other duties.

For safe use This product has been manufactured as a general-purpose part for

general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.

Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi Electric.

This product has been manufactured under strict quality control. However, when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.

USA

Brazil

Mexico

Germany

UK

Italy

Spain

France

Czech

Turkey

Poland

Russia

South Africa

China

Taiwan

Korea

Singapore

Thailand

Indonesia

Vietnam

India

Australia

Country/Region Sales office/Tel Mitsubishi Electric Automation, Inc. 500 Corporate Woods Parkway, Vernon Hills, IL 60061, U.S.A. Tel: +1-847-478-2100 Mitsubishi Electric do Brasil Comercio e Servicos Ltda. Avenida Adelino Cardana, 293, 21 andar, Bethaville, Barueri SP, Brasil CEP 06401-147 Tel: +55-11-4689-3000 Mitsubishi Electric Automation, Inc. Mexico Branch Mariano Escobedo #69, Col. Zona Industrial, Tlalnepantla Edo. Mexico, C.P.54030 Tel: +52-55-3067-7511 Mitsubishi Electric Europe B.V. German Branch Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany Tel: +49-2102-486-0 Mitsubishi Electric Europe B.V. UK Branch Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, U.K. Tel: +44-1707-28-8780 Mitsubishi Electric Europe B.V. Italian Branch Centro Direzionale Colleoni - Palazzo Sirio, Viale Colleoni 7, Agrate Brianza (MB), Italy Tel: +39-039-60531 Mitsubishi Electric Europe B.V. Spanish Branch Carretera de Rubi 76-80-Apdo.420, 08190 Sant Cugat del Valles (Barcelona), Spain Tel: +34-935-65-3131 Mitsubishi Electric Europe B.V. French Branch 25, Boulevard des Bouvets, 92741 Nanterre Cedex, France Tel: +33-1-55-68-55-68 Mitsubishi Electric Europe B.V. Czech Branch Avenir Business Park, Radlicka 751/113e, 158 00 Praha 5, Czech Republic Tel: +420-251-551-470 Mitsubishi Electric Turkey A.S. Umraniye Branch Serifali Mahallesi Nutuk Sokak No:5, TR-34775 Umraniye / Istanbul, Turkey Tel: +90-216-526-3990 Mitsubishi Electric Europe B.V. Polish Branch ul. Krakowska 50, 32-083 Balice, Poland Tel: +48-12-347-65-00 Mitsubishi Electric (Russia) LLC St. Petersburg Branch Piskarevsky pr. 2, bld 2, lit Sch, BC Benua, office 720; RU-195027 St. Petersburg, Russia Tel: +7-812-633-3497 Adroit Technologies 20 Waterford Office Park, 189 Witkoppen Road, Fourways, Johannesburg, South Africa Tel: +27-11-658-8100 Mitsubishi Electric Automation (China) Ltd. No.1386 Hongqiao Road, Mitsubishi Electric Automation Center, Shanghai, China Tel: +86-21-2322-3030 SETSUYO ENTERPRISE CO., LTD. 6F, No.105, Wugong 3rd Road, Wugu District, New Taipei City 24889, Taiwan Tel: +886-2-2299-2499 Mitsubishi Electric Automation Korea Co., Ltd. 7F-9F, Gangseo Hangang Xi-tower A, 401, Yangcheon-ro, Gangseo-Gu, Seoul 07528, Korea Tel: +82-2-3660-9530 Mitsubishi Electric Asia Pte. Ltd. 307 Alexandra Road, Mitsubishi Electric Building, Singapore 159943 Tel: +65-6473-2308 Mitsubishi Electric Factory Automation (Thailand) Co., Ltd. 12th Floor, SV.City Building, Office Tower 1, No. 896/19 and 20 Rama 3 Road, Kwaeng Bangpongpang, Khet Yannawa, Bangkok 10120, Thailand Tel: +66-2682-6522 to 31 PT. Mitsubishi Electric Indonesia Gedung Jaya 11th Floor, JL. MH. Thamrin No.12, Jakarta Pusat 10340, Indonesia Tel: +62-21-3192-6461 Mitsubishi Electric Vietnam Co., LTD. Ho Chi Minh Head Office Unit 01-04, 10th Floor, Vincom Center, 72 Le Thanh Ton Street, District 1, Ho Chi Minh City, Vietnam Tel: +84-8-3910-5945 Mitsubishi Electric India Pvt. Ltd. Pune Branch Emerald House, EL -3, J Block, M.I.D.C., Bhosari, Pune - 411026, Maharashtra, India Tel: +91-20-2710-2000 Mitsubishi Electric Australia Pty. Ltd. 348 Victoria Road, P.O. Box 11, Rydalmere, N.S.W. 2116, Australia Tel: +61-2-9684-7777

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN

When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission.

Specifications subject to change without notice.

Manualsnet FAQs

If you want to find out how the GOT1000 Mitsubishi works, you can view and download the Mitsubishi GOT1000 GT15-4-U Communication Unit User's Manual on the Manualsnet website.

Yes, we have the User's Manual for Mitsubishi GOT1000 as well as other Mitsubishi manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The User's Manual should include all the details that are needed to use a Mitsubishi GOT1000. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Mitsubishi GOT1000 GT15-4-U Communication Unit User's Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Mitsubishi GOT1000 GT15-4-U Communication Unit User's Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Mitsubishi GOT1000 GT15-4-U Communication Unit User's Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Mitsubishi GOT1000 GT15-4-U Communication Unit User's Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Mitsubishi GOT1000 GT15-4-U Communication Unit User's Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.