Mitsubishi Electric CL1X2 D1D3S User's Manual v2 PDF

1 of 1
1 of 1

Summary of Content for Mitsubishi Electric CL1X2 D1D3S User's Manual v2 PDF

Side A

Side B

JAPANESE Side B ENGLISH

SAFETY PRECAUTIONS (Read these precautions before using)

Please read this manual carefully and pay special attention to safely in order to handle this product properly. Also pay careful attention to safely and handle the module properly. These precautions apply only to Mitsubishi equipment. Refer to the users manual of the CPU module to use for a description of the PLC system safety precautions. These SAFETY PRECAUTIONS classify the safety precautions into two categories: "WARNING" and "CAUTION".

Depending on circumstances, procedures indicated by may also be linked to serious results. In any case, it is important to follow the directions for usage. Store this manual in a safe place so that you can take it out and read it whenever necessary. Always forward it to the end user. [DESIGN PRECAUTIONS]

Procedures which may lead to a dangerous condition and cause death or serious injury if not carried out properly. Procedures which may lead to a dangerous condition and cause superficial to medium injury, or physical damage only, if not carried out properly.

Configure an interlock circuit in a sequence program so that the system operates on the safety side using the communication status information in the event the data link falls into a communication problem. Otherwise, erroneous output and malfunction may result in accidents.

Remote input and output can not be switched ON or OFF when a problem occurs in the remote I/O modules. Therefore build an external monitoring circuit that will monitor any input signals that could cause a serious accident.

Do not have control cables and connection cables bundled with or placed near by the main circuit and/or power cables. Wire those cables at least 100mm(3.94 inch) away from the main circuit and/or power cables. It may cause malfunction due to noise interference.

Use the module in the status in which any force is not applied on the module, flat cables dedicated to CC-Link/LT and flat cables for I/O. If a force is applied, wire breakage or failure may be caused.

[INSTALLATION PRECAUTIONS]

[WIRING PRECAUTIONS]

Use the module in an environment that meets the general specifications contained in this manual. Using this module in an environment outside the range of the general specifications could result in electric shock, fire, erroneous operation, and damage to or deterioration of the product.

Do not directly touch the module's conductive parts. Doing so could cause malfunction or trouble in the module.

Perform installation and wiring after disconnecting the power supply at all phases externally. If the power is not disconnected at all phases an electric shock or product damage may result.

[STARTING AND MAINTENANCE PRECAUTIONS]

[DISPOSAL PRECAUTIONS]

Perform correct wiring for the module according to the products rated voltage and terminal arrangement. Connecting to a power supply different from rating or miss-wiring may cause fire, product failure or malfunction.

Make sure foreign objects do not get inside the module, such as dirt and wire chips. It may cause fire, product failure or malfunction.

Do not short-circuit the 24G and +24V terminals. It may result in fire, product failure or malfunction.

Attach a warning label (hazard symbol 417-IEC-5036) concerning the electric shock to the location.

Do not touch the terminals when the power is ON. It may cause an electric shock or malfunction.

Perform cleaning the module after turning OFF the all external power supply for sure. Failure to do so may cause failure or malfunction of the modules.

Do not disassemble or modify the module. Doing so may cause failure, malfunction, injury, or fire.

The module case is made of resin; do not drop it or subject it to strong shock. A module damage may result.

Make sure to switch all phases of the external power supply OFF before installing or removing the module to/from the panel. Failure to do so may cause failure or malfunction of the modules.

[TRANSPORTATION AND MAINTENANCE PRECAUTIONS]

Compliance with EC directive (CE marking) This notification does not guarantee that an entire mechanical module produced in accordance with the contents of the notification comply with the following standards. Compliance to EMC directive of the entire mechanical module should be checked by the user / manufacturer. Attention This product is designed for use in industrial applications. Standards with which this product complies Type : Programmable Controller (Open Type Equipment) Remote I/O module Models : Products manufactured:

from November 1st, 2002 to April 30th, 2006 are compliant with EN61000-6-4:2001 and EN61131-2:1994+A11:1996+A12:2000 after May 1st, 2006 are compliant with EN61131-2:2007

When disposing of this product, treat it as industrial waste.

During transportation avoid any impact as the module is a precision instrument. Doing so could cause trouble in the module.

If is necessary to check the operation of module after transportation, in case of any impact damage.

Electromagnetic Compatibility

Notes for compliance to EMC directive It is necessary to install the CL1 series module in a shielded metal control

panel. For more details, please contact the local Mitsubishi Electric sales site.

Directive (EMC) Remark

EN61000-6-4:2001 Electromagnetic compatibility -Generic standards - Emission standard for Industrial environment

Compliance with all relevant aspects of the standard. (Radiated Emissions and Mains Terminal Voltage Emissions)

EN61131-2:1994/A11:1996/A12:2000 Programmable controllers -Equipment requirements and tests

Compliance with all relevant aspects of the standard. Radiated electromagnetic field Fast transient burst Electrostatic discharge Damped oscillatory wave

EN61131-2: 2007 Programmable controllers -Equipment requirements and tests

Compliance with all relevant aspects of the standard. EMI Radiated Emission Conducted Emission EMS Radiated electromagnetic field Fast transient burst Electrostatic discharge High-energy surge Voltage drops and interruptions Conducted RF Power frequency magnetic field

Use this product in Zone A*1 as defined in EN61131-2. *1 Zone defined in EN61131-2

Separation defined in EN61131-2 for EMC LVD regulation decided depending on condition in industrial setting. Zone C = Factory mains which is isolated from public mains by dedicated

transformers. Zone B = Dedicated power distribution which is protected by secondary

surge protection. (300V or less in the rated voltage is assumed.)

Zone A = Local power distribution which is isolated from dedicated power distribution by AC/DC converters, isolation transformers, etc. (120V or less in the rated voltage is assumed.)

Compliance with UKCA marking The requirements for compliance with UKCA marking are the same as that with EC directive (CE marking).

1. Outline of Product This product is a cable type input module connected to CC-Link/LT. This product has two input points (24V DC).

2. Name and Setting of Each Part

24G X0 X1 +24V

CL1X2-D1D3S

402010 8 4 2 1 0.5ms 1.5ms

40 20 10 8 4 2 1 0.5ms 1.5ms

O N

Input is ON: Lit Input is OFF: Extinguished

Attach it with this area facing upward.

Status indicator LEDs

LED name PW

L RUN

Operation Lit while the power is supplied. Lit while normal operation is executed. Blue

DIP switch (Remove the switch cover when setting the DIP switch.)

DIP switch assignment

Switch cover (Make sure to attach the switch cover after setting the DIP switch.)

Input operation indicator LED

Flat cable dedicated to CC-Link/LT

Flat cable for I/O Black

White Brown

Name Description Status indicator LED

PW ON while the power is supplied. L RUN ON while normal operation is executed.

Input operation indicator LED

ON while the input is ON. Extinguished while the input is OFF.

Flat cable dedicated to CC- Link/LT

24G Connector for CC-Link/LT communication line/ module power supply

DB DA

+24V

Flat cable for I/O

Blue 24G Black X0 White X1 Brown +24V

X0 input operation

indicator LED

X1 input operation

indicator LED

0 1

DIP switch

Set the 10's digit of the station No. using "STATION NO. 10", "STATION NO. 20" and "STATION NO. 40". Set the 1's digit of the station No. using "STATION NO. 1", "STATION NO. 2", "STATION NO. 4" and "STATION NO. 8". Factory default = All bits are OFF. Make sure to set the station No. in the range from 1 to 64.

0.5ms 1.5ms

Sets the response speed. ON: 0.5 ms (fast response type) OFF: 1.5 ms (standard type)

Name Description

40 20 10 8 4 2 1 10's digit 1's digitStation

No. 32 ONOFFONOFF ON OFF OFF

Example: When setting the station No. to "32", set the DIP switch as follows.

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUC

When exported from Japan, this manual does Trade and Industry for service transaction per

does it confer any patent licenses. Mitsu responsible for any problems involving in a result of using the contents noted in th

Warranty Exclusion of loss in opportunity and seco Regardless of the gratis warranty term, Mit (1) Damages caused by any cause found (2) Loss in opportunity, lost profits incurred (3) Special damages and secondary damag for accidents, and compensation for dam (4) Replacement by the user, maintenanc other tasks.

This product has been manufactured a industries, and has not been designed device or system used in purposes rela

Before using the product for special purp aerospace, medicine or passenger move

This product has been manufactured u when installing the product where majo product fails, install appropriate backup

For safe use

Country/Region Sales office/Tel USA MITSUBISHI ELECTRIC AUTOMATION, IN

500 Corporate Woods Parkway, Vernon Hi IL 60061, U.S.A. Tel : +1-847-478-2100/+1-847-478-2500 (N

Brazil MITSUBISHI ELECTRIC DO BRASIL COMERCIO E SERVICOS LTDA. Avenida Adelino Cardana, 293, 21 andar, Bethaville, Barueri SP, Brazil Tel : +55-11-4689-3000

Germany MITSUBISHI ELECTRIC EUROPE B.V. German Branch Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany Tel : +49-2102-486-0

UK MITSUBISHI ELECTRIC EUROPE B.V. UK Br Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, UK Tel : +44-1707-28-8780

Italy MITSUBISHI ELECTRIC EUROPE B.V. Italian Branch Centro Direzionale Colleoni - Palazzo Sirio, Viale Colleoni 7, 20864 Agrate Brianza (MB) Tel : +39-039-60531/+39-039-6053-342(NC

Spain MITSUBISHI ELECTRIC EUROPE, B.V. Spanish Branch Carretera de Rubi 76-80-AC.420, E-08190 Sant Cugat del Valles (Barcelona), Spain Tel : +34-935-65-3131/+34-935-65-2236(N

France MITSUBISHI ELECTRIC EUROPE B.V. French Branch 25, Boulevard des Bouvets, F-92741 Nanterre Cedex, France Tel : +33-1-55-68-55-68

Czech Republic MITSUBISHI ELECTRIC EUROPE B.V. Czech Branch, Prague Office Pekarska 621/7, 155 00 Praha 5, Czech Republic Tel : +420-255-719-200

Poland Mitsubishi Electric Europe B.V. Polish Bran ul. Krakowska 48, 32-083 Balice, Poland Tel : +48-12-347-65-00

3. Cautions on Handling 3.1 Handling of flat cable for I/O The cable length from the module to a sensor shall be within 3m(9'10"). Measure the cable outside the module, and confirm that the driving voltage for the used sensor is assured. Input

If the diameter of the input equipment connection cable is equivalent to the diameter of the flat cable for I/O of this module, connectors dedicated to CC-Link/LT can be used for connection.

3.2 Handling of cable Do not bend the cable within 30mm(1.18") from the module.

Use a crimp-style terminal in a status in which no force is applied on the cable.

Crimp-style connection device with insulator or closed end connection device

Sensor, switch, etc.

Input equipment

Connector dedicated to CC-Link/LT

Input equipment

Wire diameter: AWG18 (34/0.18)

30mm(1.19") 30mm(1.19")

3.3 Mounting with the CL1-HLD (module holder) Refer to the figures below for details on mounting or removing the remote I/O module when used with the CL1-HLD.

4. Wiring 4.1 External wiring The input terminals of the CL1X2-D1D3S operate while using the power supplied from the interface. When connecting a sensor to the input terminal, use a sensor of the NPN open collector transistor type. Input wiring

1)Fit the remote

I/O module in

a corner of the

CL1-HLD.

2)Press down b)

while holding

a).

1)Insert a screwdriver into either a, b, c, or d.

2)Pry the remote I/O module from the

holder using the screwdriver.

Mount Dismount

CL1-HLD

Remote I/O module

a)

b)

a

b

c

d

bishi Electric Corporation cannot be held dustrial property rights which may occur as

is manual.

ndary loss from warranty liability subishi shall not be liable for compensation to: not to be the responsibility of Mitsubishi. to the user by Failures of Mitsubishi products. es whether foreseeable or not, compensation

ages to products other than Mitsubishi products. e of on-site equipment, start-up test run and

s a general-purpose part for general or manufactured to be incorporated in a ted to human life. oses such as nuclear power, electric power, ment vehicles, consult with Mitsubishi Electric. nder strict quality control. However r accidents or losses could occur if the or failsafe functions in the system.

C. lls,

Country/Region Sales office/Tel Russia Mitsubishi Electric (Russia) LLC

2, bld. 1, Letnikovskaya str.,

4.2 Connection to sensor When using a two-wire type sensor When using a three-wire type sensor

Replace * in the figure with the used input No. Notes:

24G

DA

DB

+24V DC DC

R

X1

X0

0.5A

+24V

24G

R

CL1X2-D1D3S

Isolation Flat cable dedicated to CC-Link/LT

Flat cable for I/O

Internal circuit

. . .

Bleeder resistor *1

Connected to +24 V cable

Sensor (NPN) Sensor (NPN)

X *

24G

X *

24G

Connected to +24 V cable

Detection circuit

Detection circuit

C) 115054 Moscow, Russia Tel : +7-495-721-2070

*1 Bleeder resistor

Specifications subject to change without notice.

HI, CHIYODA-KU, TOKYO 100-8310, JAPAN

not require application to the Ministry of Economy, mission.

anch

, Italy )

C)

ch

China MITSUBISHI ELECTRIC AUTOMATION (CHINA) LTD. No.1386 Hongqiao Road, Mitsubishi Electric Automation Center, Changning District, Shanghai, China Tel : +86-21-2322-3030

Taiwan SETSUYO ENTERPRISE CO., LTD. 6F, No.105, Wugong 3rd Road, Wugu District, New Taipei City 24889, Taiwan, R.O.C. Tel : +886-2-2299-2499

Korea MITSUBISHI ELECTRIC AUTOMATION KOREA CO., LTD. 7F~9F, Gangseo Hangang Xi-tower A, 401, Yangcheon-ro, Gangseo-Gu, Seoul, 07528, Korea Tel : +82-2-3660-9530

Singapore MITSUBISHI ELECTRIC ASIA PTE. LTD, 307 Alexandra Road, Mitsubishi Electric Building, Singapore 159943 Tel : +65-6473-2308

Thailand Mitsubishi Electric Factory Automation (Thailand) Co., Ltd. 12th Floor, SV.City Building, Office Tower 1, No. 896/19 and 20 Rama 3 Road, Kwaeng Bangpongpang, Khet Yannawa, Bangkok 10120, Thailand Tel : +66-2682-6522~31

Indonesia PT. Mitsubishi Electric Indonesia Gedung Jaya 8th Floor, JL. MH.Thamrin No.12, Jakarta Pusat 10340, Indonesia Tel : +62-21-3192-6461

India Mitsubishi Electric India Pvt. Ltd. Gurgaon Branch 2nd Floor, Tower A & B, Cyber Greens, DLF Cyber City, DLF Phase - III, Gurgaon - 122002, Haryana, India Tel : +91-124-4630300

Australia MITSUBISHI ELECTRIC AUSTRALIA PTY. LTD. 348 Victoria Road PO BOX11, Rydalmere, N.S.W 2116, Australia Tel : + 61-2-9684-7777

When connecting a two-wire type sensor or input equipment having parallel resistor, select a sensor or equipment whose leakage current is 1.7mA or less. If the leakage current is more than 1.7mA, connect a bleeder resistor obtained in the following calculation formula. Circuit image

R(k) < 1.7(mA) / Leakage current(mA) - 1.7(mA) x 5.6(k) The power capacity W of the bleeder resistor R is as follows: W = (Input voltage)2/R

If chattering is present in the external input equipment, set 1.5ms. If the ON or OFF time of the input signal is less than 1.5 ms, set it to 0.5

ms. (The ON and OFF time of the input signal are required to be 0.5 ms or more.) When setting 1.5 ms: Set both the ON and OFF time of the input signal to 1.5 ms or more. When setting 0.5 ms: Set both the ON and OFF time of the input signal to 0.5 ms or more.

R

24V DC

Leakage current

Input impedance 5.6 k 1.7 mA or less

R: Bleeder resistor

Sensor Unit

Detection circuit

5. Specifications 5.1 General specifications

Item Specification Ambient working temperature

0 to 55C (32 to 131F)

Ambient storage temperature -25 to 75C (-13 to 167F)

Ambient operating humidity

5 to 95%RH: Dew condensation shall not be considered.

Ambient storage humidity 5 to 95%RH: Dew condensation shall not be considered.

Vibration resistance (*1)

When intermittent vibration is present Number of times of sweep

Frequency Acceleration Half amplitude

10 times in each of X, Y and Z directions (for 80 min)

10 to 57Hz 0.075mm 57 to 150Hz 9.8m/s2

When continuous vibration is present Frequency Acceleration Half amplitude 10 to 57Hz 0.035mm 57 to 150Hz 4.9m/s2

Impact resistance (*1) 147 m/s2, 3 times in each of X, Y and Z directions

Operating atmosphere Corrosive gas shall not be present.

Operating altitude 2,000m(6561'8") or less (*2)

Installation place Inside control panel (*3)

Over-voltage category or less (*4)

Degree of contamination 2 or less (*5)

Notes: *1 The criterion is shown in IEC61131-2.

*2 The module cannot be used in an environment pressurized above the

atmospheric pressure which can be generated around the altitude of 0 m. If the module is used in such an environment, it may fail.

*3 The module can be used in any environment even outside the control panel as far as the requirements of the ambient operating temperature, the ambient operating humidity, etc. are satisfied.

*4 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within premises. Category applies to equipment for which electrical power is supplied from fixed facilities. The surge voltage withstand level for up to the rated voltage of 300V is 2500V.

*5 This index indicates the degree of conductive generating substances in the environment in which the module is used. The degree of contamination 2 indicates that contamination is caused by generation of only non-conductive substances. In this degree, however, temporary conduction may be caused by accidental condensation.

5.2 Input specifications Item Specification

Input method DC input (using module power supply in common) Number of inputs 2 points Isolation method Isolation with photocoupler Rated input voltage 24V DC Rated input current Approx. 4 mA Operating voltage range Same as module power supply Max. simultaneous ON input points 100% (at 24V DC)

ON voltage/ON current 19 V or more/3 mA or more OFF voltage/OFF current 11 V or less/1.7 mA or less Input resistance 5.6 k

Response time

OFFON 0.5ms/1.5ms or less (at 24V DC) Selected by DIP switch (default value = OFF/1.5ms).

ONOFF 0.5ms/1.5ms or less (at 24V DC) Selected by DIP switch (default value = OFF/1.5ms).

Common wiring method 2 point/1 common (1 point)

5.3 Performance specifications Item Specification

Module power supply

Voltage 20.4 to 28.8V DC (24V DC -15% to +20%) Ripple ratio: Within 5%

Current consumption

40mA (when all points are ON) (Current consumption does not contain the input current.)

Initial current 70mA Max. allowable

momentary power failure period

PS1:1ms

Number of stations occupied 4-, 8- or 16-point mode: 1 station

Noise durability 500Vp-p Noise width: 1s Cycle: 25 to 60 Hz (by noise simulator)

Withstand voltage 500V AC for 1 min

Isolation resistance 10 M or higher between primary area (external DC terminal) and secondary area (internal circuit) by 500V DC insulation resistance tester

Protection class IP2X I/O part connection method Connection with cable Module installation method Can be installed in six directions Flat cable for I/O (wire diameter) AWG18 (34/0.18)

Mass (weight) 0.07 kg (0.15 lbs) (including 500mm(19.69") flat cable dedicated to CC-Link/LT and 500mm(19.69") flat cable for I/O)

6. Outside Dimensions

Unit: mm(inches)

24G X0 Y0 +24V

20(0.79")

65 (2

.5 6"

) 50

0( 19

.6 9"

)

12(0.48")

50 0(

19 .6

9" )

This manual confers no industrial property rights or any rights of any other kind, nor

CL1X2-D1D3S CC-Link/LT Remote I/O Module

Please read this manual thoroughly before starting to use the product and handle the product properly.

Users Manual MODEL CL1X2-D1D3S MANUAL Number JY997D03901M

Manualsnet FAQs

If you want to find out how the CL1X2 D1D3S Mitsubishi Electric works, you can view and download the Mitsubishi Electric CL1X2 D1D3S User's Manual v2 on the Manualsnet website.

Yes, we have the User's Manual for Mitsubishi Electric CL1X2 D1D3S as well as other Mitsubishi Electric manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The User's Manual should include all the details that are needed to use a Mitsubishi Electric CL1X2 D1D3S. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Mitsubishi Electric CL1X2 D1D3S User's Manual v2 is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Mitsubishi Electric CL1X2 D1D3S User's Manual v2 consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Mitsubishi Electric CL1X2 D1D3S User's Manual v2 free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Mitsubishi Electric CL1X2 D1D3S User's Manual v2, simply download the document to your computer. Once downloaded, open the PDF file and print the Mitsubishi Electric CL1X2 D1D3S User's Manual v2 as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.