* Filterpack (FR-BFP) o
(3) The attachment is applica with other rails.
Single-phase 100V class FR-S510WE-0.1K to 0.4K FR-S510WE-0.75K Single-phase 200V class FR-S520SE-0.1K to 0.75K FR-S520SE-1.5K
FR-C500 200V class FR-C520-0.1K, 0.2K, 0.4K, 0.75K FR-C520-1.5K, 2.2K FR-C520-3.7K
FR-F500J* 200V class FR-F520J-0.4K, 0.75K FR-F520J-1.5K, 2.2K FR-F520J-3.7K 400V
FR-FP500J* 200V 400V
Applicable Rail TH35-7.5 Rail w TH35-15 Rail w
the rail mounting screw pitch should be no more than the corresponding value
: Must not be mounted nt pitches are used together on the same DIN rail, choose the minimum
ail, it can endure continuous vibration equivalent to (approximately) 2.45m/s2.
two frequencies having a ratio of 2 to 1.
500 300 200 150 500 500 500
K, 0.2K 1K, 0.2K .1K, 0.2K
FR-E720-0.4K, 0.75K FR-E720S-0.4K, 0.75K
FR-E710W-0.4K
FR-E720-1.5K, 2.2K FR-E720S-1.5K
FR-E710W-0.75K FR-E720-3.7K
K, 0.2K .1K, 0.2K .1K, 0.2K
FR-D720-0.4K, 0.75K FR-D720S-0.4K, 0.75K
FR-D710W-0.4K
FR-D720-1.5K, 2.2K FR-D720S-1.5K
FR-D740-0.4K to 3.7K FR-D710W-0.75K
FR-D720-3.7K
1K, 0.2K .1K, 0.2K .1K, 0.2K
FR-S520E-0.4K, 0.75K FR-S520SE-0.4K, 0.75K
FR-S510WE-0.4K
FR-S520E-1.5K, 2.2K FR-S540E-0.4K to 3.7K
FR-S520SE-1.5K FR-S510WE-0.75K
FR-S520E-3.7K
K, 0.2K FR-C520-0.4K, 0.75K FR-C520-1.5K, 2.2K FR-C520-3.7K
FR-F520J-0.4K, 0.75K FR-F520J-1.5K, 2.2K FR-F540J-0.4K to 3.7K FR-F520J-3.7K
FR-FP520J-0.4K to 2.2K FR-FP540J-0.4K to 3.7K FR-FP520J-3.7K
Sweep Count
10 times (1 octave*/1 minute)
(a) Channel mounting (b) Enclosure surface mounting
1/2
f FR-F500J and FP500J series cannot be installed to a DIN rail installation attachment.
ble to the DIN, EN, IEC standard-compliant 35mm wide rails given below. Do not use the attachment
class FR-F540J-0.4K to 3.7K class FR-FP520J-0.4K to 2.2K FR-FP520J-3.7K class FR-FP540J-0.4K to 3.7K
Rail Specifications idth 35mm, height 7.5mm idth 35mm, height 15mm
INVERTER DIN Rail Mounting Attachment
Thank you for choosing the Mitsubishi transistorized inverter option unit. This instruction manual gives handling information and precautions for using this product. Incorrect handling might cause an unexpected fault. Before using the equipment, always read this manual carefully to use it to its optimum. Please forward this manual to the end user.
This product is the attachment to install an inverter or energy saving drive to a DIN rail.
1. Preparation (1) Check the attachment type to confirm that the product is as you ordered.
(2) Following models are compatible with DIN rail installation attachment. Do not use the attachment to a non-compatible model.
Safety Instructions
Do not touch inverter, power saving drive, and DIN rail installation attachment while power is ON or right after power is shut down because these devices are extremely hot. Touching these devices can cause a burn.
Carry the product in a correct manner according to its weight. Not doing so can cause injury. Also, be careful of the edges.
Always inspect the product after mounting. Not doing so can cause it to drop due to incorrect installation, resulting in an accident.
Inverter/energy saving drive Capacity of compatible inverter/energy saving drive
FR-UDA01 FR-UDA02 FR-UDA03
FR-E700 200V class FR-E720-0.1K to 0.75K FR-E720-1.5K, 2.2K FR-E720-3.7K
Single-phase 100V class FR-E710W-0.1K to 0.4K FR-E710W-0.75K Single-phase 200V class FR-E720S-0.1K to 0.4K FR-E720S-0.75K, 1.5K
FR-D700
200V class FR-D720-0.1K to 0.75K FR-D720-1.5K, 2.2K FR-D720-3.7K 400V class FR-D740-0.4K to 3.7K
Single-phase 100V class FR-D710W-0.1K to 0.4K FR-D710W-0.75K Single-phase 200V class FR-D720S-0.1K to 0.75K FR-D720S-1.5K
FR-S500
200V class FR-S520E-0.1K to 0.75K FR-S520E-1.5K, 2.2K FR-S520E-3.7K 400V class FR-S540E-0.4K to 3.7K
(4) Due to the mechanical strength of the rail, indicated in the following table.
DIN rail mounting screw pitch L (mm)
Note: If the mounted models of differe mounting screw pitch.
Mounting screw pitch
(5) When the inverter is mounted on the DIN r
* Octave indicates the interval between any
(a) Channel mounting
TH35-7.5 100 TH35-15 500
(b) Enclosure surface mounting
TH35-7.5 250 TH35-15 500
Compatible inverter/energy saving drive
FR-E720-0.1 FR-E720S-0. FR-E710W-0
FR-D720-0.1 FR-D720S-0 FR-D710W-0
FR-S520E-0. FR-S520SE-0 FR-S510WE-0
FR-C520-0.1
Frequency Acceleration Amplitude 10 to 55Hz 0.075mm 55 to 150Hz 9.8m/s2
Mounting screw pitch
L L L
Specifications subject to change without notice.
BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
tachment to Inverter ve the inverter's front cover in accordance with the
rom DIN Rail
p of the groove into the top side of the DIN rail and as been fixed securely.
To check whether the inverter has been mounted to the DIN rail securely or not, push up the inverter (with force at about 3Nm) as shown below. If the inverter does not come off, the inverter is mounted securely. If it comes off, mount it to the DIN rail then push it up again.
Recommended installation screw size
Inverter
M4 0.7L=12
FR-E720-0.1K to 3.7K FR-E720S-0.1K to 1.5K FR-E710W-0.1K to 0.75K FR-D720-0.1K to 3.7K FR-D740-0.4K to 3.7K FR-D720S-0.1K to 1.5K FR-D710W-0.1K to 0.75K FR-S520E-0.1K to 0.75K, 3.7K FR-S520SE-0.1K to 0.75K FR-S510WE-0.1K to 0.4K FR-C520-0.1K to 0.75, 3.7K FR-F520J-0.4K, 0.75K, 3.7K FR-FP520J-3.7K
M4 0.7L=16
FR-S520E-1.5K, 2.2K FR-S540E-0.4K to 3.7K FR-S520SE-1.5K FR-S510WE-0.75K FR-C520-1.5K, 2.2K FR-F520J-1.5K, 2.2K FR-F540J-0.4K to 3.7K FR-FP520J-0.4K to 2.2K FR-FP540J-0.4K to 3.7K
unting
,03
unting status on DIN rail
4. DIN Rail Mounting Attachment Outline Dimension Drawings
FR-UDA01 FR-UDA02 FR-UDA03
Hook Hook Hook
68 108
67
1 2 8
8 .7
15 67
15 10
1 2 8
8 .7
1 2 8
8 .7
170
67
(Unit: mm) 4-M4 0.7 screw
14.4
4-M4 0.7 screw3-M4 0.7 screw
IB-0600032-D(0901)MEE Printed in Japan
HEAD OFFICE: TOKYO
2/2
(2) Dismounting 1) Using a flat-blade screwdriver (6 100), pull down the hook at the bottom of the DIN adaptor. 2) With the hook pulled down, pull the inverter toward you to dismount it from the DIN rail.
Inverter
DIN adaptor Hook
Screwdriver
Dismounting direction
2. Installation of DIN Rail Mounting At (1) When installing the DIN rail mounting attachment to the inverter, first remo
inverter instruction manual.
(2) Precautions for installation 1) Be careful so that the mounting screws do not enter the inverter.
3. Mounting and Dismounting to and f (1) Mounting
To prevent the inverter from dropping due to a mounting fault, insert the to press the inverte