Contents

Mitsubishi Electric FR E7CN Instruction Manual PDF

1 of 8
1 of 8

Summary of Content for Mitsubishi Electric FR E7CN Instruction Manual PDF

1

Heatsink Protrusion Attachment

INVERTER

Thank you for choosing this Mitsubishi Electric inverter option. This Instruction Manual provides handling information and precautions for use of the equipment. Incorrect handling might cause an unexpected fault. Before using this inverter, always read this Instruction Manual carefully to use the equipment to its optimum performance. Please forward this Instruction Manual to the end user.

This attachment is used to protrude the inverter heatsink to the rear panel of enclosure. This attachment dissipates about 70% of the heat generated by the inverter.

1. Applicable inverter

: Applicable

This section is specifically about safety matters

While power is ON or for some time after power-OFF, do not touch the inverter and the attachment as they will be extremely hot. Touching these devices may cause a burn.

The product must be transported in a suitable method which corresponds with the product mass. Failure to do so may lead to injuries. Special attention must be paid to the edges of the product.

Foreign conductive objects must be prevented from entering the inverter. That includes screws and metal fragments or other flammable substance such as oil.

Applicable inverter Applicable attachment

FR-E7CN01 FR-E7CN02 FR-E7CN03 FR-E7CN04 FR-E7CN05 FR-E7CN06

E700

FR-E720-1.5K, 2.2K FR-E720S-0.75K, 1.5K

FR-E720-3.7K

FR-E720-5.5K, 7.5K

FR-E740-1.5K, 2.2K, 3.7K FR-E720S-2.2K

FR-E740-5.5K, 7.5K

FR-E720-11K, 15K FR-E740-11K, 15K

D700

FR-D720-1.5K, 2.2K FR-D720S-1.5K FR-D740-1.5K, 2.2K, 3.7K

FR-D720-3.7K

FR-D720S-2.2K

FR-D720-5.5K, 7.5K FR-D740-5.5K, 7.5K

FR-D720-11K, 15K FR-D740-11K, 15K

F700PJ

FR-F720PJ-1.5K, 2.2K FR-F740PJ-1.5K, 2.2K, 3.7K

FR-F720PJ-3.7K

FR-F720PJ-5.5K, 7.5K FR-F740PJ-5.5K, 7.5K

FR-F720PJ-11K, 15K FR-F740PJ-11K, 15K

2. Product confirmation and assembly example (1) The following items are provided in a package. Check the contents and the quantity.

* Use the side covers for a rectangular cut that is made on an enclosure. (Refer to page 3 for enclosure cut dimensions.)

(2) Part names

(3) Assembly example FR-E7CN03

* Use the side covers for a rectangular cut that is made on an enclosure. Refer to page 3 for enclosure cut dimensions. (FR-E7CN05 and 06 do not have side covers.)

No. Name Attachment model

FR-E7CN01, 02 FR-E7CN03 FR-E7CN04 FR-E7CN05 FR-E7CN06 1) Upper installation frame 1 1 1 1 1 2) Upper cover 1 1 1 1 1 3) Lower installation frame 1 1 1 1 1 4) Side cover* 2 2 2 - - 5) Frame installation screw 4 (M412) 4 (M520) 4 (M412) 4 (M416) 4 (M520) 6) Cover installation screw 4 (M48) 2 (M48) 4 (M48) 2 (M48) 2 (M48)

No. Name Description 1) Upper installation frame A frame for securing the inverter onto the (upper) enclosure surface. 2) Upper cover A cover for the fan-replacement hole of the upper frame. 3) Lower installation frame A frame for securing the inverter onto the (lower) enclosure surface. 4) Side cover Covers to fill the space around a cut that is made on an enclosure. 5) Frame installation screw Screws to mount the upper and lower frames to the inverter body. 6) Cover installation screw Screws to mount the upper and side covers to the enclosure.

Assembly diagram Assembled product (with side covers)

REMARKS

To replace a cooling fan, remove "2) upper cover" first, then replace the fan through the hole. (For the details, refer to the Instruction Manual of the inverter.)

3) Lower installation frame

1) Upper installation frame

5) Frame

installation

screw

2) Upper cover

6) Cover installation screw

4) Side cover*

4) Side cover*

Inverter 3) Lower

installation

frame

1) Upper installation frame

2) Upper cover

6) Cover

installation

screw

4) Side

cover*

2

3. Enclosure cut dimensions Cut an enclosure to the following dimensions according to the inverter capacity.

FR-E7CN01 (with side covers) FR-E7CN01(without side covers)

FR-E7CN02 (with side covers) FR-E7CN02 (without side covers)

FR-E7CN03 (with side covers) FR-E7CN03 (without side covers)

57

0 .5

34

0 .5

14 8

0.

5 90

0

.5

23 8

5. 5

123

137 0.5

10-M4 screw

(Unit: mm) 27

83 27

104

104

123

(1 01

)

5. 5

14 8

0.

5 90

0

.5

23 8

137 0.5

6-M4 screw

(Unit: mm)

176

190 0.5

23 9

4. 5

57

0 .5

34

0 .5

14 8

0.

5 90

0

.5

(Unit: mm)

10-M4 screw 166

27 85

27

4. 5

166

176

190 0.5

(1 00

)

14 8

0.

5 90

0

.5

23 9

(Unit: mm)

6-M4 screw

185

200 0.5

36 7

7. 5

80

0 .5

12 0.

5

0. 5

90

0 .5

28 0

0.

5

(Unit: mm)

10-M5 screw 175

200 0.5

36 7

7. 5

90

0 .5

(1 6.

5) 28

0

0. 5

30 20

5 30

10 2

175

185

(Unit: mm)

6-M5 screw

3

FR-E7CN04 (with side covers) FR-E7CN04 (without side covers)

FR-E7CN05 FR-E7CN06

NOTE The cooling section, which comes out of the enclosure, has a cooling fan. Because of this, this attachment cannot

be used in an environment with water drops, oil, mist, dust, etc. Be careful not to drop screws, dust, etc. into the inverter and cooling fan section. The heatsink protrusion attachment is mounted to the inverter with about 1mm space between their mounting sur-

faces.

57

0. 5

17 0

0.

5 90

0.

5

25 6.

5

56

0 .5

160 0.5

143 8.

5

(Unit: mm)

10-M4 screw

90

0 .5

25 6.

5

160 0.5

136

8. 5

17 0

0.

5

24 10

5 24

10 3.

5

136

143

(Unit: mm)

6-M4 screw

221 234 0.5

25 7

8. 5

17 0

0.

5 90

0

.5

(Unit: mm)

6-M4 screw 175

195 0.5

10 2

26 5

7. 5

36 7

212

27 9.

5

0. 5

90

0 .5

(Unit: mm)

4-M5 screw

2-M5 screw

4

4. Outline dimension (------ : enclosure cut lines) FR-E7CN01 (with side covers) FR-E7CN01 (without side covers)

FR-E7CN02 (with side covers) FR-E7CN02 (without side covers)

FR-E7CN03 (with side covers) FR-E7CN03 (without side covers)

* The dimensions are different for the FR-E700 series inverters with plug-in options.

(135.5) *

2.3

60

20

Attachment

75.5 *

11 4

(1 28

)

Enclosure

10 (1

4)

0. 2

58 .6

(0 .2

) 54

.5 14

8. 5

26 2

86.5

153

10 4

2-5 hole (4.1)

(Unit: mm)

Attachment

4-oval hole (5 10)

4-oval

hole

(4.8 9)

Enclosure

(135.5) *

2.3

60

20

75.5*

11 4

(1 28

)

10 4

10

54 .5

14 8.

5

26 2

86.5

153

(1 4)

(4.1)

2-5 hole

4-oval hole (5 10)

Attachment

Enclosure

Attachment

Enclosure

(Unit: mm)

2.3 76* 66.5

(142.5)*

20 (1

28 )

11 4

148.5

209

54 .5

14 8.

5

26 2

10 4

0. 2

58 .6

(0 .2

)

10 (1

4)

(4.1)2-5 hole

4-oval hole (5 10)

4-oval

hole

(4.8 9)

Attachment

Enclosure

(Unit: mm)

Attachment

Enclosure

148.5

209

54 .5

14 8.

5

26 2

(1 28

) 20

2.3

76* 66.5

(142.5)*

11 4

10 4

10 (1

4)

(4.1) 2-5 hole

4-oval hole (5 10)

Attachment

Enclosure

Attachment

Enclosure

(Unit: mm)

(2 60

) 11

6. 5

148.5

219

20

93.5* 71.5

(165)*

2

75 .5

0. 2

14 9.

1 (0

.2 )

17 1.

5

10 (1

6. 5)

39 6.

5

(5.4)2-6 hole

4-oval hole (6 12)

4-oval

hole

(6 8)

Attachment

Enclosure

(Unit: mm)

Attachment

Enclosure

(2 60

) 11

6. 5

148.5

219

20

93.5* 71.5

(165)*

2

75 .5

17 1.

5

10 (1

6. 5)

39 6.

5

(5.4)2-6 hole

4-oval hole (6 12)

Attachment

Enclosure

Attachment

Enclosure

(Unit: mm)

5

The dimensions are different for the FR-E700 series inverters with plug-in options.

FR-E7CN04 (with side covers) FR-E7CN04 (without side covers)

FR-E7CN05 FR-E7CN06

(1 50

)

2.3 75* 60

(135)*

11 4

20

10 179

118.5

80 .6

0. 2

(0 .2

) 54

.5 14

8. 5

28 4

10 4

(1 4)

(4.1) 2-5 hole

4-oval hole (5 10)

4-oval

hole

(4.8 9)

Attachment

Enclosure

(Unit: mm)

Attachment

Enclosure

(1 50

)

2.3

75* 60

(135)*

11 4

20

10

179

118.5

54 .5

14 8.

5

28 4

10 4

(1 4)

(4.1)

2-5 hole

4-oval hole (5 10)

Attachment

Enclosure

Attachment

Enclosure

(Unit: mm)

(1 50

)

79* 68

(147)*

2

11 6.

5 20

194.5

253

10 (1

6. 5)

64 .5

14 6

28 6.

5

10 4

(4.1)2-5 hole

4-oval hole (5 10)

Attachment

Enclosure

(Unit: mm)

Attachment

Enclosure

245 22

72 40

8

(1 6.

5)

15 6 11

6. 5

(2 60

) 32

12.3

2.3 86*

(170)*

84 (5.4)

10 3.

5

6-6.5 hole

Attachment

Enclosure

(Unit: mm)

Attachment

Enclosure

6

MEMO

7

IB(NA)-0600370ENG-A(1010)MEE Printed in Japan Specifications subject to change without notice.

HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN<

Manualsnet FAQs

If you want to find out how the FR E7CN Mitsubishi Electric works, you can view and download the Mitsubishi Electric FR E7CN Instruction Manual on the Manualsnet website.

Yes, we have the Instruction Manual for Mitsubishi Electric FR E7CN as well as other Mitsubishi Electric manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Instruction Manual should include all the details that are needed to use a Mitsubishi Electric FR E7CN. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Mitsubishi Electric FR E7CN Instruction Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Mitsubishi Electric FR E7CN Instruction Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Mitsubishi Electric FR E7CN Instruction Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Mitsubishi Electric FR E7CN Instruction Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Mitsubishi Electric FR E7CN Instruction Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.