2/4 IB(NA)-0600541ENG-B

rocedure rews at the both sides of the control circuit terminal block of FR-A800/F800 series inverter. oved.) terminal block to remove it.

or lower, the FR-A840-00620(22K) or lower, FR-F820-01250(30K) or lower, or FR-F840- remove the fixing screw for earthing (grounding) cable, and instead attach the provided torque: 0.33 to 0.4 Nm) or higher, the FR-A840-00770(30K) or higher, FR-F820-01540(37K) or higher, or FR- verter, fit the bracket to the inverter, into the place shown in the figure below.

ot to bend the pins of inverter control circuit connector. or lower, the FR-A840-00620(22K) or lower, FR-F820-01250(30K) or lower, or FR-F840- fix the A8TAT to the inverter and the hexagon spacer using the provided installation .33 to 0.4 Nm) or higher, the FR-A840-00770(30K) or higher, FR-F820-01540(37K) or higher, or FR- verter, fix the A8TAT to the inverter and the bracket using the provided screws. (Tightening

nal block of the FR-A700/F700(P)/A500/F500 series inverter. Be careful not to bend the onnector. Fix the control circuit terminal block using the installation screws of the control ing torque: 0.33 to 0.4 Nm)

FR-A820-01540(30K) or higher FR-A840-00770(30K) or higher

Bracket

Insert the bracket into the tab.xagon spacer

Fix with screws. 5K)

Fix with screws.

1/4 IB(NA)-0600541ENG-B

INVERTER Control Circuit Terminal Block Intercompatibility Attachment

Thank you for choosing this Mitsubishi Electric inverter option unit. This Instruction Manual provides handling information and precautions for use of the equipment. Incorrect handling might cause an unexpected fault. Before using this product, always read this Instruction Manual carefully to use this product correctly. Please forward this Instruction Manual to the end user.

1 Unpacking and checking the product Take the product out of the package, and confirm that the product is as you ordered and intact. The product is an option for the FR-A800/F800 series.

Used with the FR-A820-01250 (22K) or lower, FR-A840-00620 (22K) or lower, FR-F820-01250(30K) or lower, and FR-F840- 00620(30K) or lower.

Used with the FR-A820-01540(30K) or higher, FR-A840-00770(30K) or higher, FR-F820-01540(37K) or higher, and FR- F840-00770(37K) or higher.

Applicable control circuit terminal blocks

2 Installation p (1) Loosen the two installation sc

(These screws cannot be rem Slide down the control circuit

For the FR-A820-01250(22K) 00620(30K) or lower inverter, hexagon spacer. (Tightening For the FR-A820-01540(30K) F840-00770(37K) or higher in

(2) Install the A8TAT. Be careful n (3) For the FR-A820-01250(22K)

00620(30K) or lower inverter, screws. (Tightening torque: 0 For the FR-A820-01540(30K) F840-00770(37K) or higher in torque: 0.33 to 0.4 Nm)

(4) Install the control circuit termi pins of A8TAT control circuit c circuit terminal block. (Tighten

Warning While the inverter power is ON, do not remove the front cover or the wiring cover. Do not operate the inverter with

any cover or wiring cover removed, as accidental contact with exposed high-voltage terminals and internal components may occur, resulting in an electrical shock.

Even if power is OFF, do not remove the front cover except for wiring or periodic inspection as you may accidentally touch the charged inverter circuits and get an electric shock.

Before wiring or inspection, check that the display of the operation panel is OFF. Any person who is involved in wiring or inspection shall wait for at least 10 minutes after the power supply has been switched OFF and check that there are no residual voltage using a tester or the like. The capacitor is charged with high voltage for some time after power OFF, and it is dangerous.

Any person who is involved in wiring or inspection of this equipment shall be fully competent to do the work. Do not touch the printed circuit board or handle the cables with wet hands. Doing so may cause an electric shock. Do not subject the cables to scratches, excessive stress, heavy loads or pinching. Doing so may cause an electric shock.

FR-A8TAT 1

Installation screw (M36) 2

Hexagon spacer 1

Bracket 1

FR-A800 series FR-A700 series FR-A500 series

FR-F800 series FR-F700(P) series FR-F500 series

Loosen the screws.

FR-A820-01250 (22K) or lower FR-A840-00620 (22K) or lower

He

Remove the screw.

Example of FR-A820-00105 (1.

4/4 IB(NA)-0600541ENG-B

se of Hazardous Substances in Electronic and oducts

zardous substances in electronic and electrical products is applied to the product as ent Methods for the Restriction of the Use of Hazardous Substances in Electrical and le's Republic of China.

GB/T26572

GB/T26572

(Pb)

(Hg)

(Cd)

(Cr(VI))

(PBB)

(PBDE)

anual number Revision

00541ENG-A First edition

00541ENG-B

Addition Compatibility with the FR-F800 series inverters Precautions for removal and reinstallation of the A8TAT Restricted Use of Hazardous Substances in Electronic and

Electrical Products

BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

3/4 IB(NA)-0600541ENG-B

3 Precautions for removal and reinstallation of the A8TAT The following are the precautions to remove or reinstall the A8TAT. Observe the following for proper handling to avoid malfunctions or failures of the inverter. To remove or reinstall the A8TAT, keep it upright so that it is parallel with the inverter. To install the A8TAT, slide it upward so that the groove on the terminal block fits over the tongue on the inverter.

Adjust the A8TAT position for alignment with the screw fixing bases. Check that the A8TAT is parallel with the inverter and the pins of the inverter's control circuit connector are not bent.

After checking the proper connection, fix the terminal block with two screws.

NOTE Do not tilt the A8TAT while tightening the screws or removing it from the inverter. (Otherwise, a

stress applied to the A8TAT or the control circuit connector may cause damage to them.)

4 Restrictions for using the inverter with the A8TAT For using the control circuit terminal block of the FR-A500/F500 series, open or remove the cover of the control

circuit terminal block. Otherwise, the front cover of the inverter may not close properly. Since the specifications of the control circuit terminals of the FR-A700/F700(P)/A500/F500 series are different from

those of the FR-A800 series, certain functions of the inverter are restricted (refer to the table below).

...Available ...Not available The FR-A800/F800 plug-in option FR-A8NC or FR-A8NCE, or the FR-A800 plug-in option FR-A8NS cannot be

installed. When using a plug-in option, connect the plug-in option using a cable that can be routed through the space

between the front cover and the control circuit terminal block (FR-A700/F700(P) series: 7 mm, FR-A500/F500 series: 0.8 mm).

5 Restricted U Electrical Pr

The mark of restricted use of ha follows based on the Managem Electronic Products of the Peop

SJ/T11364

REVISIONS

Relay output 2 terminals

24 V external power sup- ply input terminal

Safety stop signal terminals

FR-A500/F500 series

FR-A700/F700(P) series

Inverter's control circuit connector

A

Fit the groove over the tongue.

Insert the terminal block parallel into the inverter.

FR-A8TAT Fasten the screws.

Inverter's control circuit connector

FR-A8TAT

View from A side

Print date * M

May 2014 IB(NA)-06

Dec 2017 IB(NA

Manualsnet FAQs

If you want to find out how the FR A8TAT Mitsubishi Electric works, you can view and download the Mitsubishi Electric FR A8TAT Instruction Manual on the Manualsnet website.

Yes, we have the Instruction Manual for Mitsubishi Electric FR A8TAT as well as other Mitsubishi Electric manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Instruction Manual should include all the details that are needed to use a Mitsubishi Electric FR A8TAT. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Mitsubishi Electric FR A8TAT Instruction Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Mitsubishi Electric FR A8TAT Instruction Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Mitsubishi Electric FR A8TAT Instruction Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Mitsubishi Electric FR A8TAT Instruction Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Mitsubishi Electric FR A8TAT Instruction Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.