nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.
Warranty Exclusion of loss in opportunity and secondary loss from warranty liability Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation to: (1) Damages caused by any cause found not to be the responsibility of Mitsubishi. (2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products. (3) Special damages and secondary damages whether foreseeable or not, compensation for
accidents, and compensation for damages to products other than Mitsubishi products. (4) Replacement by the user, maintenance of on-site equipment, start-up test run
and other tasks.
For safe use This product has been manufactured as a general-purpose part for general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life. Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi Electric. This product has been manufactured under strict quality control. However when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
Safety Precaution (Read these precautions before use.)
This manual classifies the safety precautions into two categories:
and .
Depending on the circumstances, procedures indicated by may also cause severe injury. It is important to follow all precautions for personal safety.
Associated Manuals
How to obtain manuals For product manuals or documents, consult with the Mitsubishi Electric dealer from who you purchased your product.
Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.
Manual name Manual No. Description
FX3S Series Users Manual - Hardware Edition
JY997D48601 MODEL CODE:
09R535
Explains the FX3S Series PLC specifications for I/O, wiring, installation, and maintenance.
Applicable standards FX3S-CNV-ADP units comply with the EC Directive (EMC Directive). Further information can be found in the following manual.
FX3S Series Hardware Manual (Manual No. JY997D48301) Attention This product is designed for use in industrial applications.
1. Outline The connection conversion adapter is an adapter for connecting the analog special adapters and communication special adapters to the FX3S PLC.
1.1 Incorporated Items Verify that the following product and items are included in the package:
1.2 External Dimensions and Part Names
[1] Main body mounting hole 1 (2-3.2) (Use when connecting to main unit of AC power type)
[2] Main body mounting hole 2 (2-3.2) (Use when connecting to main unit of DC power type)
[3] Special adapter slide hook [4] Special adapter connector [5] Nameplate [6] Board connector 1
(Use when connecting to main unit of AC power type) [7] Board connector 2
(Use when connecting to main unit of DC power type)
[8] Board connector cover*1
[9] Main body connector [10] Memory cassette connector cover [11] Board mounting hole (2-3.2) [12] Memory cassette connector [13] Main unit connector
*1 Default configuration of board connector cover is installed to [7]. Install to [6] when connecting to main unit of DC power type.
Included Item
FX3S-CNV-ADP 1 unit
Tapping screws for installation (M38) 4 pcs.
Installation Manual (This manual) 1 manual each
74 (2.92") 14.6 (0.58")
90 (3
.5 5"
)
[Connector conversion adapter (main body)]
[Connector conversion adapter (board)]
[3]
[1]
[9]
[11] [12]
[5]
[10]
[13]
[8]
[6] [7][4] Unit: mm (inches)
MASS (Weight): Approx. 0.1 kg (0.22 lbs)
Connector cover is removed
[2]
2. Installation For details on installation, refer to the following manual.
FX3S Series User's Manual - Hardware Edition
3. Specifications
3.1 Applicable PLC
For details on the system configuration, refer to the following manual. FX3S Series User's Manual - Hardware Edition
3.2 General Specifications The general specifications are equivalent to the PLC main unit. For general specifications, refer to the following manual.
FX3S Series User's Manual - Hardware Edition
INSTALLATION PRECAUTIONS
Make sure to cut off all phases of the power supply externally before attempting installation or wiring work. Failure to do so may cause electric shock or damage to the product.
INSTALLATION PRECAUTIONS
Use the product within the generic environment specifications described in PLC main unit manual (Hardware Edition). Never use the product in areas with excessive dust, oily smoke, conductive dusts, corrosive gas (salt air, Cl2, H2S, SO2 or NO2), flammable gas, vibration or impacts, or expose it to high temperature, condensation, or rain and wind. If the product is used in such conditions, electric shock, fire, malfunctions, deterioration or damage may occur.
Use screwdrivers carefully when performing installation work, thus avoiding accident or product damage.
When drilling screw holes or wiring, make sure cutting or wire debris does not enter the ventilation slits. Failure to do so may cause fire, equipment failures or malfunctions.
Do not touch the conductive parts of the product directly. Doing so may cause device failures or malfunctions.
Connect the adapter securely to their designated connectors. Loose connections may cause malfunctions.
STARTUP AND MAINTENANCE PRECAUTIONS
Do not disassemble or modify the PLC. Doing so may cause fire, equipment failures, or malfunctions. * For repair, contact your local Mitsubishi Electric representative.
Do not drop the product or exert strong impact to it. Doing so may cause damage.
DISPOSAL PRECAUTIONS
Please contact a certified electronic waste disposal company for the environmentally safe recycling and disposal of your device.
TRANSPORTATION AND STORAGE PRECAUTIONS
The product is a precision instrument. During transportation, avoid impacts larger than those specified in the general specifications by using dedicated packaging boxes and shock-absorbing palettes. Failure to do so may cause failures in the product. After transportation, verify operation of the product and check for damage of the mounting part, etc.
Model name Applicability
FX3S Series PLC Ver. 1.00 or later (from first production)
This manual confers no industrial property rights or any rights of any other kind,
Note: This symbol mark is for China only.
6 6
SJ/T 11364
:GB/T 26572
:GB/T 26572
: GB/T15969.2
(Pb)
(Hg)
(Cd)
(Cr(VI))
(PBB)
(PBDE)
FX3S-CNV-ADP
INSTALLATION MANUAL
This manual describes the part names, dimensions, mounting, and specifications of the product. Before use, read this manual and the manuals of all relevant products fully to acquire proficiency in handling and operating the product. Make sure to learn all the product information, safety information, and precautions. Store this ma