Kleenmaid RHCR120 Hood Instructions For Use PDF

1 of 16
1 of 16

Summary of Content for Kleenmaid RHCR120 Hood Instructions For Use PDF

3

4

5

A=

Wall cooker hood

B=

Island hood

1X 2X 1X 150 mm

A 1x 2X 6x 4.2x9.5 4x 3.5x6.5 x 3.5x4.5

1X 1X 4x 18x6 8x 6 8x 4.2x32

1X 1X

10

2xM5x25

6

min. 650 mm (wall)

min. 700 mm (island)

7

mm mm

mm (A) 8 mm (B)

6

70 70

98 98

A1

A3

A5

A7

A2

A4

A6

A8

1135 mm

8

A9

B1

B3

B5

B4

B6

A10

B2

9

A+B

B7

125

A+B

B8

ONLY IF WALL HOLE 125

10

THIS PRODUCT IS DESIGNED FOR DOMESTIC USE. THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR DAMAGES TO THINGS OR PEOPLE DERIVING FROM INCORRECT INSTALLATION OR IMPROPER, ERRONEOUS OR UNSUITABLE USE. THE APPLIANCE MUST NOT BE USED BY PEOPLE (INCLUDING CHILDREN) WITH PHYSICAL, SENSORIAL OR MENTAL IMPAIRMENTS, OR BY PEOPLE WITHOUT THE NECESSARY EXPERIENCE

OR KNOWLEDGE, UNLESS THEY ARE SUPERVISED OR INSTRUCTED IN THE USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY. CHILDREN MUST BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE.

Dear Customer, we would like to thank you and congratulate you on your choice. This new product has been carefully designed and built using top quality materials, and meticulously tested to ensure that it meets all your culinary requirements. Please read and observe these simple instructions, which will enable you to achieve excellent results from the very rst time you use it. This state-of-the-art appliance comes to you with our very best wishes.

THE MANUFACTURER

11

The hood may be installed in the filtering or in the ducting version. Exhausting version (Fig.1) the hood aspirates the kitchen air saturated with fumes and odours, purifies it through the grease filters and expels it through an outlet pipe. With his version the charcoal filters are not required. Filtering version (Fig.1A) the hood aspirates the kitchen air saturated with fumes and odours, purifies it through the grease filters and the charcoal filters and returns clean air into the room. The charcoal filters are not supplied.

Decide from beginning on the type of installation. For greater efficiency, we recommend to install the hood in exhausting version.

Use gloves during installation and maintenance operations.

In case of exhausting version it is important : - to prepare the hole and the duct of 150

mm.diameter - to use a duct with the minimal indispensable

length - to use a duct with few curves as possible (max

curve angle 90) - to avoid to use flat ducts or with different

sections - to use a duct with the smoother surface inside

and of a certified material - dont connect the hood to fumes exhaust ducts

(fireplaces, boilers, stoves,) - fi ,eloh llaw a otni detaucave eb ton nac ria eht

this hole is not dedicated to this purpose - to equip the room of air intakes in order to not

create air depression (it must not exceed the 0,04 mbar)

CONTROLS

A B C D E F G H I

A) ON/ OFF motor (it switches the hood on the second speed)

B) 1st motor speed C) 2nd motor speed D) 3rd motor speed E) 4th motor speed F) ON/OFF lamps: if pressed long, it permits

to select 3 different levels. Last selected level will remain in memory when the cooker hood restarts.

G) TIMER: it permits to select 3 several ranges(10, 15, 20 minutes)

H) *Filter alarm I) Remote control signal receiver

*Filter alarm: the first operation once you have connected the cooker hood to the power, is to set it into exhausting or recycling mode. Proceed as follows: once the cooker is connected all the keys will light for some seconds: press the key on/off for around 8 seconds until that the key H is not lighted. Press the key B if you want the cooker hood to work in exhausting mode (in this way the charcoal filter counter is not working because it is not required); the red key H is blinking and you can confirm pressing it. To set the cooker hood into recycling mode (grease filters and charcoal filters counter) you must press the key C after the 8 seconds and the key H will be lighted red fix; pressing on it you can confirm. After 30 hours working, the key H will light fix: this means that it is time to clean the grease filters. After 140 hours working the key H will blink

12

red: this means that the grease filters must be cleaned and the charcoal filters replaced. To reset, press the key H longer for second 7-8. Note well: it is not possible to reset partially the counter times until the system doesnt show one of the alarms. This means that intermediate resets are not possible.

REMOTE CONTROL FUNCTIONS

A B

C D

A) ON/OFF motor (it switches the hood on the second speed)

B) It decreases the motors speed C) It increases the motors speed D) ON/OFF lamps (it is possible to set the

lamps intensity only manually on the hood)

MAINTENANCE Before cleaning and maintenance

operations, would you please disconnect the power. Cooker hood cleaning: the cooker hood must be cleaned at least each 2 months in order to prevent the fires risk; to clean the hood externally, a soft cloth moistened with warm water and neutral soap must be used for the painted cooker hoods and specific cleaning producs for the stainless steel cooker hoods. To clean the cooker hood internally, use a cloth with denatured alcohol. Do not use abrasive or corrosive products! Grease filters cleaning(for exhausting and filtering executions)

shtnom 2 hcae tsael ta sretlif esaerg eht naelC in order to prevent the fires risk and anyway according the use of the appliance. To remove the grease filters push on the filters handle.

Wash them hand or in the dishwasher by using a neutral soap. Please take also into consideration that the dishwasher wash can alter the grease filters colour but not its features. Charcoal filters replacement (in case of filtering execution): The charcoal filters must be replaced at least each 6 months in order to prevent fires risk and anyway according the use of the appliance.

How to replace the charcoal filters :

Insert the charcoal filter in the special slots and then clip it (as shown in the picture)

13

Lamps replacement:

Remove the lamp glass gently with a screwdriver. Replace with a lamp of the same type. Do not touch the new lamp with bare hand.

Dont touch the lamps if they are still hot!

MALFUNCTION Before contacting the Technical Service, please verify these simple cases: Why the cooker hood is not working? - is there power cut? - Is the cooker hood switched off? - Is the plug disconnected or damaged? Why the cooker hood is inefficient? - is the cooker hood working at the suitable

speed to remove the quantity of the fumes and vapours?

- Is the kitchen room enough ventilated to permit an adeguate air intake?

- Must the grease filters be cleaned? - Must the charcoal filters be replaced?(in case of

filtering cooker hood) - After 10 minutes continuous working at the 4th

speed, the cooker hood goes automatically to the 2nd speed (normal working speed)

Why the cooker hood switched off while is working? - Is there a sudden power cut? - Is the plug disconnected or damaged? - After 5 hours continuous working the cooker

hood turns off automatically(energy saving).

Manualsnet FAQs

If you want to find out how the RHCR120 Kleenmaid works, you can view and download the Kleenmaid RHCR120 Hood Instructions For Use on the Manualsnet website.

Yes, we have the Instructions for Use for Kleenmaid RHCR120 as well as other Kleenmaid manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Instructions for Use should include all the details that are needed to use a Kleenmaid RHCR120. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Kleenmaid RHCR120 Hood Instructions For Use is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Kleenmaid RHCR120 Hood Instructions For Use consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Kleenmaid RHCR120 Hood Instructions For Use free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Kleenmaid RHCR120 Hood Instructions For Use, simply download the document to your computer. Once downloaded, open the PDF file and print the Kleenmaid RHCR120 Hood Instructions For Use as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.