Register your product www.kaercher.com/welcome

8.634-334.0-N 10/11/19

500 PSI-13 Gallon English 02

LISTED

2 86343340 PUZZI 50/35

Warranty Registration Thank you for purchasing a Krcher North America product. Warranty registration is quick and easy. Your registration will allow us to serve you better over the lifetime of the product.

To register your product go to : http://warranty.karcherna.com

For customer assistance: 1-800-444-7654

Machine Data Log / Overview

OVERVIEW

The machine is an electric powered carpet extractor intended for commercial use. This appliance applies a cleaning solution to the carpet and then vacuums the soiled water back into the recovery tank.

Model:

Date of Purchase:

Serial Number:

Dealer:

Address:

Phone Number:

Sales Representative:

MODEL: PUZZI 50/35 1.006-672.0

86343340 PUZZI 50/35 3

Table of Contents

Machine Data Log / Overview. . . . . . . . . . . . . . . . . .2

Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . .3

How to Use This Manual . . . . . . . . . . . . . . . . . . . . . .4

Safety IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . .5 HAZARD INTENSITY LEVEL . . . . . . . . . . . . . . . . . .6 Safety Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Grounding Instructions . . . . . . . . . . . . . . . . . . . . . . .8

Operations Technical Specifications . . . . . . . . . . . . . . . . . . . . . .9 Controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Machine Operation . . . . . . . . . . . . . . . . . . . . . . . . .11 Chemicals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Pre-Run Inspection . . . . . . . . . . . . . . . . . . . . . . . . .12 Equipment Set-up . . . . . . . . . . . . . . . . . . . . . . . . . .12 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

Maintenance Periodic Maintenance . . . . . . . . . . . . . . . . . . . . . . .14 Daily/Regular Maintenance. . . . . . . . . . . . . . . . . . .14 Vacuum Motor Replacement . . . . . . . . . . . . . . . . .15 Solution Pump Replacement . . . . . . . . . . . . . . . . .16 Pressure Regulator . . . . . . . . . . . . . . . . . . . . . . . . .17 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . .18

PARTS Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Electrical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Pump. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Recovery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Solution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Vacuum. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Suggested Spare Parts. . . . . . . . . . . . . . . . . . . . . 38 Serial Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

4 86343340 PUZZI 50/35

How to Use This Manual

This manual contains the following sections:

How to Use This Manual

Safety

Operations

Maintenance

Parts List

The HOW TO USE THIS MANUAL section will tell you how to find important information for ordering correct repair parts.

Parts may be ordered from authorized dealers. When placing an order for parts, the machine model and machine serial number are important. Refer to the MACHINE DATA box which is filled out during the installation of your machine. The MACHINE DATA box is located on the inside of the front cover of this manual.

The model and serial number of your machine is located approximately where shown.

Model:

Date of Purchase:

Serial Number:

Dealer:

Address:

Phone Number:

Sales Representative:

Serial Number Tag

The SAFETY section contains important information regarding hazardous or unsafe practices of the machine. Levels of hazards are identified that could result in product damage, personal injury, or severe injury resulting in death.

The OPERATIONS section is to familiarize the operator with the operation and function of the machine.

The MAINTENANCE section contains preventive main- tenance to keep the machine and its components in good working condition. They are listed in this general order:

Maintenance

Lubrication

Vacuum Motor Replacement

Solution Pump Replacement

Troubleshooting

The PARTS LIST section contains assembled parts illustrations and corresponding parts list. The parts lists include a number of columns of information:

REF column refers to the reference number on the parts illustration.

PART NO. column lists the part number for the part.

PRV NO. reference number.

QTY column lists the quantity of the part used in that area of the machine.

DESCRIPTION column is a brief description of the part.

SERIAL NO. FROM If this column has an (*) and a Reference number, see the SERIAL NUMBERS page in the back of your manual. If column has two asterisk (**), call manufacturer for serial number. The serial number indicates the first machine the part number is applicable to. The main illustration shows the most current design of the machine. When a boxed illustra- tion is shown, it displays the older design.

NOTES column for information not noted by the other columns.

NOTE: If a service or option kit is installed on your machine, be sure to keep the KIT INSTRUCTIONS which came with the kit. It contains replacement parts numbers needed for ordering future parts.

NOTE: The manual part number is located on the lower left corner of the front cover.

86343340 PUZZI 50/35 5

Safety

IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precaution

must always be followed, including the following:

READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE.

This machine is for commercial use.

To reduce the risk of fire, electric shock, or injury:

Connect to a properly grounded outlet. See Grounding Instructions.

Do not leave the machine unattended. Unplug machine from outlet when not in use and before mainte- nance or service.

Use only indoors. Do not use outdoors or expose to rain.

Do not allow machine to be used as a toy. Close attention is necessary when used by or near children.

Use only as described in this manual. Use only manufacturer's recommended components and attach- ments.

Do not use damaged electrical cord or plug. Follow all instructions in this manual concerning grounding the machine. If the machine is not working properly, has been dropped, damaged, left outdoors, or dropped into water, return it to an authorized service center.

Do not pull or carry machine by electrical cord, use as a handle, close a door on cord, or pull cord around sharp edges or corners.

Do not run machine over cord. Keep cord away from heated surfaces.

Do not unplug machine by pulling on cord. To unplug, grasp the electrical plug, not the electrical cord.

Do not handle the electrical plug or machine with wet hands.

Do not operate the machine with any openings blocked. Keep openings free of debris that may reduce airflow.

This machine is intended for cleaning carpet only.

Do not vacuum anything that is burning or smoking, such as cigarettes, matches, or hot ashes.

This machine is not suitable for picking up health endangering dust.

Turn off all controls before unplugging.

Do not operate this machine near flammable fluids, dust or vapors.

Maintenance and repairs must be done by qualified personnel.

If foam or liquid comes out of machine, switch off immediately.

SAVE THESE INSTRUCTIONS

6 86343340 PUZZI 50/35

Safety

The following symbols are used throughout this guide as indicated in their descriptions:

HAZARD INTENSITY LEVEL

There are three levels of hazard intensity identified by signal words -WARNING and CAUTION and FOR SAFETY. The level of hazard intensity is determined by the following definitions:

WARNING - Hazards or unsafe practices which COULD result in severe personal injury or death.

CAUTION - Hazards or unsafe practices which could result in minor personal injury or product or property damage.

FOR SAFETY: To Identify actions which must be followed for safe operation of equipment.

Report machine damage or faulty operation immediately. Do not use the machine if it is not in proper operating condition. Following is information that signals some potentially dangerous conditions to the operator or the equip- ment. Read this information carefully. Know when these conditions can exist. Locate all safety devices on the machine. Please take the necessary steps to train the machine operating personnel.

FOR SAFETY:

DO NOT OPERATE MACHINE: Unless Trained and Authorized. Unless Operation Guide is Read and understood. In Flammable or Explosive areas. In areas with possible falling objects.

WHEN SERVICING MACHINE: Avoid moving parts. Do not wear loose clothing; jackets, shirts, or sleeves when working on the machine. Use only manufacturer approved replacement parts.

86343340 PUZZI 50/35 7

Safety

Safety Labels NOTE: These drawings indicate the location of safety labels on the machine. If at any time the labels become illegible, promptly replace them.

Label Warning 86333370

Label Circuit Interrupter 86333380

8 86343340 PUZZI 50/35

Safety

Grounding Instructions

THIS PRODUCT IS FOR COMMERCIAL USE ONLY.

ELECTRICAL:

In the USA this machine operates on a standard 15 amp 115V, 60 hz, A.C. power circuit. The amp, hertz, and voltage are listed on the data label found on each machine. Using voltages above or below those indicated on the data label will cause serious damage to the motors.

EXTENSION CORDS:

If an extension cord is used, the wire size must be at least one size larger than the power cord on the machine, and must be limited to 50 feet (15.5m) in length.

GROUNDING INSTRUCTIONS:

This appliance must be grounded. If it should malfunc- tion or break down, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and grounding plug. The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordi- nances.

This appliance is for use on a nominal 120-volt circuit, and has a grounded plug that looks like the plug in "Fig. A". A temporary adaptor that looks like the adaptor in "Fig. C" may be used to connect this plug to a 2-pole receptacle as shown in "Fig. B", if a properly grounded outlet is not available. The temporary adaptor should be used only until a properly grounded outlet (Fig. A) can be installed by a qualified electrician. The green colored rigid ear, lug, or wire extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adaptor is used, it must be held in place by a metal screw.

Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

86343340 PUZZI 50/35 9

Height

LengthWidth

Technical Specifications

ITEM MEASURE

Electrical 115 Volt, 60 hz, 15A

Solution Pump 500 psi

Solution Capacity 13 Gal

Recovery Capacity 11 Gal

Height 43 inches

Length 30 inches

Width 22 inches

Vacuum Motor Single 3 Stage

Weight- Empty 117 lbs

Weight-Full Solution 222 lbs

Power cord 1 X 40 feet inline GFCI

Operations

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for thier safety.

10 86343340 PUZZI 50/35

Operations

Controls

1. Vacuum Accessory Tool Hook-up

2. Solution Pump Switch

3. Vacuum Switch

4. Breaker for Vacuum

5. Solution Accessory Tool Hook-up

6. Pressure Gauge

7. Adjustable Pressure Relief Valve

1 3 2 6

745

86343340 PUZZI 50/35 11

Operations

Machine Operation

Care must be exercised in the use of all chemicals. Chemicals are poisonous and can pose a health risk. Read and follow manufacturers instructions regarding dangers and correct usages.

The internal parts of the pump used in the machine are suitable for use with most carpet cleaning chemicals. But they are susceptible to chemical attack from some cleaning substances, such as hydrocarbon solvents and chlorinated bleaches. These non-compatible materials are not of the type used for carpet cleaning.

Chemicals

Suitable Chemicals Alkalis

Detergents

Hydroxides

Soaps

Vinegar

Non-Compatible Aldehydes

Aromatics Hydrocarbons

SP Butyls

Carbon Tetrachloride

Clorox*

Chlorinated Bleaches

Chlorinated Hydrocarbons

Lysol*

Methyl Ethel Ketone (MEK)

Perchorethylene (perc)

Phenolics

Trichlorethylene

D-Limonene

*Registered Trademark

Only use chemicals approved for use with this machine. Use of non-compatible chemicals may cause machine damage and will not be covered under the warranty. Carefully read ingredients on manufacturers label before using any product in this machine.

Do not let pump run dry.

Do not let pump run unattended.

12 86343340 PUZZI 50/35

Operations

Pre-Run Inspection

1. Check all fittings and connectors for proper assembly.

2. Check all hoses for leaks. Repair or replace any damaged hoses.

3. Check power cord(s) for any damage. If damaged, replace.

Equipment Set-up

1. Plug power cord from machine into properly grounded wall outlet.

2. Turn vacuum motor switch on and off to make sure there is electrical power at machine.

3. Using a clean container, fill the solution tank with clean hot water. Do not use water over 130F. Mix in a non-foaming cleaning concentrate for use in hot water extraction machines, following the manu- facture's instructions printed on container.

4. Connect priming hose to solution fitting on machine. Turn on pump and run for 30 seconds or until a steady flow of water is coming out of priming hose. Turn off pump and disconnect priming hose.

5. Connect vacuum hose to machine. Slide the swivel cuff over the outlet on the tank.

6. Connect the hose to your machine and wand. Pull back the knurled collar on the quick disconnect coupler and push onto the connection on the chassis. To avoid leaks, check to be that a positive connection was made.

NOTE: When using a powder cleaner, pre-mix with hot water in a clean container before adding to the solution tank.

7. Turn pump and vacuum switch to the on position.

86343340 PUZZI 50/35 13

Operations

Cleaning

Always use defoamer if foaming occurs. Foam will suspend large particles that may damage vacuum as well as allow liquid into the vacuum motor without activating the float shutoff.

1. Prior to cleaning, make certain that the nozzle is functioning properly.

a. To check, hold the wand about one foot above the surface to be cleaned and open the wand valve. A full spray should be observed from the nozzle.

b. If the nozzle is not showing a full spray pattern, adjust nozzle for proper pattern, clean, or replace nozzle.

2. Normally, chemical is applied on the push stroke of the wand when cleaning. Vacuuming is done on the pull stroke. For heavily soiled carpets the wand may be used in a scrubbing manner, applying chemical in both the push and pull stroke.

3. When cleaning, keep the working opening (wand mouth) flat on the surface being cleaned. Keep the wand moving when the valve is open.

4. The shutoff float inside the vacuum tank will impede the vacuum flow when the vacuum tank is full. When this occurs, empty the vacuum tank by opening the dump valve and dispose of the waste in a proper manner.

5. Once the vacuum tank has been emptied, you may once again proceed with cleaning

14 86343340 PUZZI 50/35

Maintenance

Periodic Maintenance

Twice a month, flush a white vinegar solution (one quart vinegar to two gallons of water) or anti-browning solution (mixed as directed) through the machine. This will prevent build-up of alkaline residue in the system.

Periodically inspect all hoses, electrical cables and connections on your machine. Frayed or cracked hoses should be repaired or replaced to eliminate vacuum or solution pressure loss. The electrical cable must be well insulated and cable connector screw kept tight. If the cable insulation is broken or frayed, repair or replace immediately. Don't take chances with electrical fire or shock.

SERVICE SCHEDULE DAILY WEEKLY QUARTERLY

Check machine for cord damage *

Check recovery dome and gasket for damage and cleanliness *

Check hoses for wear, blockages, or damage *

Check handles, switches, and knobs for damage *

Run one gallon of water through solution system *

Clean out recovery tank and check float valve to make sure it moves freely *

Clean out solution tank and remove and clean vacuum intake screen *

Clean outside of all tanks and check for damage *

Run vac motor for at least one minute to allow motor to dry *

Store with dome off tank to allow the tank to dry *

Check all gaskets for wear and leakage *

Check pump pressure; observe spray pattern and check with gauge if necessary

*

Check and clean solution screen *

Check cables for fraying *

Check overall performance of machine *

Check vac motor carbon brushes *

Daily/Regular Maintenance

Before making any repairs or adjustments to the machine, disconnect the power cord from the elec- trical source.

1. Empty unused cleaning solution from the solution tank.

2. Inspect and clean filter screen in solution tank.

3. Flush pumping system with 1 to 2 gallons of clean water.

4. After each use, rinse tank with fresh water. Periodi- cally inspect the recovery tank and decontaminate if necessary, using a Hospital Grade Virucide or a 10-1 bleach to water solution. Waste water should be disposed of properly.

Do not allow machine to freeze.

86343340 PUZZI 50/35 15

Maintenance

Only qualified maintenance personnel are to perform the following repairs.

Vacuum Motor Replacement

1. Turn off all switches and unplug machine.

2. Remove hardware under front of machine to access component compartment.

3. Remove vacuum motor cover and disconnect motor wires.

4. Remove the vacuum motor.

5. Reverse process to install vacuum motor.

Vacuum Motor Carbon Brushes Replacement

3 8 [9.5mm]

Carbon Brushes

End Cap

WARNING: The green ground wire must be attached for safe operation. See wiring diagram.

If armature commutator is grooved, extremely pitted or not concentric, the motor will need to be replaced or sent to a qualified service center.

Important:

These brushes wear quicker as the length shortens due to increased heat. Spring inside brush housing will damage motor if brushes are allowed to wear away completely.

Periodically check the length of the carbon brushes. Replace both carbon brushes when either is less than 3/8" (9.5mm) long.

16 86343340 PUZZI 50/35

Maintenance

Solution Pump Replacement

Only qualified maintenance personnel are to perform the following repairs.

8.756-049.0

8.756-049.0

Seal and O-Ring Kit 8.756-049.0

86343340 PUZZI 50/35 17

Maintenance

Only qualified maintenance personnel are to perform the following repairs.

Pressure Regulator

For best results with the pressure regulator, we recommend that you clean and lubricate the piston and u-cup with Superlube lubricant monthly or when pressure drop seems excessive.

1. Turn unit off before lubricating.

2. Remove cap, spring and spring retainer plate.

3. With fingertips remove piston and u-cup.

4. Wipe piston and u-cup clean of any film or scale.

5. Lubricate the piston and u-cup with Superlube.

6. Reassemble regulator.

7. With pump ON, re-adjust pressure regulator for normal operation.

Lubricate U-Cup with Superlube Monthly.

(GREEN 500 PSI) REBUILD KIT 8.619-924.0

18 86343340 PUZZI 50/35

Maintenance

Troubleshooting

PROBLEM CAUSE SOLUTION

Loss of Power

Unit not plugged in Connect unit to 3 prong grounded outlet.

Dead electrical circuit Check building circuit breaker or fuse box.

Faulty power cord Replace

Electrical shock Receptacle not grounded Contact an electrician to check building's wiring

Internal wiring problem Have a trained service technician check machine's wiring

Vac motor speed varies or doesn't run

Vacuum circuit breaker tripped Reset Breaker

Faulty vacuum motor Replace

Faulty switch Replace

Loss of vacuum

Loose vacuum dome Center and seal dome over tank

Crack in dome of poor joint Replace or repair using acrylic plastic cement only

Lint or dirt clogging vacuum screen With power off clean screen

Loose cuffs on vacuum hose Tighten cuffs turning counterclockwise

Vac motor seals leaking Replace

Floor tool vac chamber clogged Wash out with hose. Pick lint out with a wire

Vacuum hose damaged Replace

Recovery tank full / Float ball stuck in the up position

Turn off power, drain recovery tank.

Pump runs no solution

Pump inlet screen plugged Clean inlet screen

Pump not primed Prime pump with priming hose

Internal or external solution line damaged and leaking

Replace

Pump runs, loss of pressure

Internal pump components wearing out Replace, see pump kit components

Check valves in pump head for particles or cuts in seals

Take piston from BPR and lubricate with Super- lube. If problem still exists change BPR kit

Pump will not run Faulty switch Replace

Loose wiring Repair or replace

Solution hose fitting hard to connect

Corrosion on fittings. Clean with steel wool. Soak in acetic acid (white vinegar). Lubricate lightly with silicone base lubricant.

Carpet not getting clean

Severe soil conditions Make several passes at right angles to each other. Use a pre-spray.

Carpet too wet Over saturation Adjust solution pressure to lower settings. Make several passes without spray

Carpet browning Leaving carpet too wet Check for loss of vac pressure

Too much chemical Check label for correct solution concentration

Solution not flowing properly

Solution hose connection Check for positive connection

Faulty pump Repair or replace

Faulty floor tool valve / Nozzle Repair or replace

Faulty pump switch Repair

Rate your product and tell us your opinion.

valuer votre produit et dites-nous votre opinion.

www.kaercher.com/welcome

www.kaercher.com/dealersearch

Alfred Krcher SE & Co. KG Alfred-Krcher-Str. 28-40 71364 Winnenden (Germany) Tel.: +49 7195 14-0 Fax: +49 7195 14-2212

DANKE! THANK YOU! MERCI! GRACIAS!

!

Registrieren Sie Ihr Produkt und profitieren Sie von vielen Vorteilen.

Register your product and benefit from many advantages.

Enregistrez votre produit

Manualsnet FAQs

If you want to find out how the Puzzi 50 35 Karcher works, you can view and download the Karcher Puzzi 50 35 500 PSI-13 Gallon 1.006-672.0 Instructions Manual on the Manualsnet website.

Yes, we have the Instructions Manual for Karcher Puzzi 50 35 as well as other Karcher manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Instructions Manual should include all the details that are needed to use a Karcher Puzzi 50 35. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Karcher Puzzi 50 35 500 PSI-13 Gallon 1.006-672.0 Instructions Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Karcher Puzzi 50 35 500 PSI-13 Gallon 1.006-672.0 Instructions Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Karcher Puzzi 50 35 500 PSI-13 Gallon 1.006-672.0 Instructions Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Karcher Puzzi 50 35 500 PSI-13 Gallon 1.006-672.0 Instructions Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Karcher Puzzi 50 35 500 PSI-13 Gallon 1.006-672.0 Instructions Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.