DS-KD8003-IME1(B)/NS Video Intercom Module Door Staon
UD29432B-A
1
Microphone 2 Built-in Camera3
Loudspeaker4 TAMPER 65 Network Interface
Note: The module-connecng interface is used to connect other funcon module, such as nametag module, keypad module, card reader module, etc. All these modules are known as sub module.
Appearance1
Module-Connecng Interface
1 Low Illuminaon IR Supplement Light
Terminals8
Terminal
Installation Positions
2
4
A1 A2 A3 A4 A5 A6 A7 A8
NC1: Door Lock Relay Output (NC) NO1: Door Lock Relay Output (NO) COM: Common Interface NC2: Door Lock Relay Output (NC) NO2: Door Lock Relay Output (NO) GND: Grounding 12 VDC: Power Input GND: Grounding
B1 B2 B3 B4 B5 B6 B7 B8
AIN2: For the access of Door Contact 2 AIN1: For the access of Door Contact 1 AIN3: For the access of Exit Buon 1 AIN4: For the access of Exit Buon 2 485-: Module-connecng Interface 485+: Module-connecng Interface 12V OUT: Module-connecng Interface GND: Module-connecng Interface
C PoE Network Interface (Supports IEEE 802.af)
Installaon3 Note: Video intercom module door staon support one-module installaon, two-module installaon, three- module installaon and more-than-three-module installaon. Here takes three-module installaon as an example.
Note: When you connect to 12VDC power input and PoE switch at the same time, the priority of 12 VDC is higher than PoE Switch. When the device is powered off, you should to disconnect the network cable from PoE Switch before disconnecting the power cable.
Tools that you need to prepare for installaon: Drill(6), cross screw driver (PH1*150 mm), and gradienter. Make sure all the related equipment is power-off during the installaon. Make sure you have configured the sub module address before installaon. Valid sub
module address range is 1 to 8. The No. should be unique for sub modules that connected to the same main unit. The sub module address and corresponding switch status is shown as the figure.
Recommended Installation Height (The distance between the camera and the ground): 1.4 m to 1.6 m The FOV of the camera is : Horizontal: 146, Vertical: 82. The highest visual height and lowest visual height of the camera is shown as picture.
Before You Start
Three-Module Flush Mounng 1. Cave the installaon hole, and pull the cable out. Note: The suggested dimension of the installaon hole is 321.8(W) 108(H) 45.5(D) mm. The suggested length of the cables le outside is 270 mm. 2. Select a cable entry and remove the plasc sheet. Route the cables through the gang box hole. Insert the gang box into the installaon hole. Mark the gang box screw holes posion with a marker, and take out the gang box. 3. Drill 4 holes according to the marks on the wall, and insert the expansion sleeves into the screw holes. Fix the gang box with 4 expansion bolts. Fill the gap between the gang box and wall with concrete or Silicone sealant. Remove the mounng ears with tool aer concrete is dry. 4. Connect cables and insert the modules. a.Connect Cable 1 and one end of Cable 2 to the corresponding interfaces of the main
unit, then insert the main unit into the upper grid. b.Connect the other end of Cable 2 to the input interface of Sub Module 1. Connect
one end of Sub Module 1 and insert it into the middle grid. c.Connect the other end of Cable 3 to the input interface of Sub Module 2. Insert it
into the boom grid. 5. Fix the cover and the main unit with 2 socket head cap screws by using a hexagon wrench. Surface Mounng with Protecve Shield 1. Paste the installaon scker 1 onto the wall. Make sure the scker is placed horizontally via measuring with the gradienter. Drill 4 holes according to the screw holes on the scker. Note: The suggested size of hole is 6(diameter) 25(depth) mm. The suggested length of the cables le outside is 270 mm. 2. Remove the scker and insert the expansion sleeves into the screw holes. Fix the mounng frame onto the wall with 4 expansion bolts. 3. Thread the module-connecng line across the thread holes of the frame. Pass the main unit connecng line across the thread hole to the top grid and connect the cables. a.Connect the lines and module-connecng line 1 to the corresponding interfaces of
the main unit, then place the main unit into the upper grid. b.Connect the other end of the module-connecng line 1 to the input interface of the
sub modules via module-connecng line 2. c.Organize the cables with cable e in the package.
4. Insert the modules into the frame aer wiring. The main unit must be placed in the top grid. 5. Use the hexagon wrench in the package to fix the cover onto the frame.
Gang Box
1 2 3 4 5
13
1 2 3 4 5
Expansion Bolt
Mounng Ear
Sub Module 1
Sub Module 2
Hexagonal Screw2
2
1
3
3
3
Module-Connecng Line1
Module-Connecng Line2
Thread Hole
Cables Connected to Main Unit
Sub Module
Mounng Frame
Hexagonal Screw
Cover Hexagon Wrench
13
2 4
A1 A8 B8B1 C
LAN
GN D
12V O U T
485+ 485-
AIN 4
AIN 3
AIN 1
AIN 2
GN D
GN D
12V DC
N C1
N C2
N O 2
N O 1
CO M
RS485ALARM INDOOR
Sub Module Address DIP 1 DIP 2 DIP 3 DIP 4 DIP 5 DIP 6 DIP 7 DIP 8 Module 1 ON OFF OFF OFF OFF OFF OFF OFF Module 2 OFF ON OFF OFF OFF OFF OFF OFF Module 3 ON ON OFF OFF OFF OFF OFF OFF Module 4 OFF OFF ON OFF OFF OFF OFF OFF Module 5 ON OFF ON OFF OFF OFF OFF OFF Module 6 OFF ON ON OFF OFF OFF OFF OFF Module 7 ON ON ON OFF OFF OFF OFF OFF Module 8 OFF OFF OFF ON OFF OFF OFF OFF
Vertical: 82
Highest Height: 1.93 m
Lowest Height: 1 m
0.5 m
1.5 m
Vertical: 82
Highest Height: 2 m
Lowest Height: 1.16 m
0.5 m
1.6 m
Horizontal: 146
0.5 m
Vertical: 82
Highest Height: 1.83m
Lowest Height: 0.96m
0.5 m
1.4 m
Recommended Installation Height (The distance between the camera and the ground): 1.4 m to 1.6 m