DS-PK1-LT-WE/WB Series Wireless LCD Keypad

Diagram References

E N G L I S H

2022 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved. About this Manual The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision website (https://www.hikvision.com/). Please use this Manual with the guidance and assistance of professionals trained in supporting the Product.

Trademarks and other Hikvisions trademarks and logos are the properties of Hikvision in various jurisdictions.

Other trademarks and logos mentioned are the properties of their respective owners.

Disclaimer TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED AS IS AND WITH ALL FAULTS AND ERRORS. HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS. YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK, VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED. YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATTER PREVAILS.

Appearance

2 Indication

1

+ identifies the positive terminal(s) of equipment which is used with, or generates direct current. - identifies the negative terminal(s) of equipment which is used with, or generates direct current. No naked flame sources, such as lighted candles, should be placed on the equipment. The serial port of the equipment is used for debugging only. Install the equipment according to the instructions in this manual. To prevent injury, this equipment must be securely attached to the floor/wall in accordance with the installation instructions. Keep right direction when using the equipment. The additional force shall be equal to three times the weight of the equipment but not less than 50N. The equipment and its associated mounting means shall remain secure during the installation. After the installation, the equipment, including any associated mounting plate, shall not be damaged.

Fault

Fire Alarm Panic Alarm Medical Alarm Stay Arm

Away Arm Settings Output Disarm Back Scroll Up/Delete Scroll Down

Confirm Swipe Tag

Query Lock

Armed/Disarmed Enrollment/Signal Strength

With Fault Enrollment

LED Description

Armed

Disarmed

Solid orange

Solid blue

Solid green

Alarm

Find Me Mode

Note: Event Alarm Priority > Tampering Alarm Priority

Tampering Alarm: Solid red Event Alarm: Flashing red No Alarm: Off

Flashing red

OffNo Fault

Signal Strength

Power On

Back Light

Alarm

Flashing green: Strong Flashing orange: Medium Flashing red: Weak/Disconnect

Flashing orange: Enrolling Green flashes 7 times: Enrolled

Solid green for 1 s

-The back light is on by default, you can set the On/Off schedule on the web client/APP of the control panel. Refer to the user manual of control panel. -It turns off when there is no key operation for more than 10 s to 30 s (adjustable). -If the keypad is not enrolled to the control panel, the back light is off.

1

Tamper Switch

Power Switch

Touch Key Serial Port

MCU Serial Port

RFM Serial Port

Flashing green

Flashing blue

Entry Delay

Exit Delay

UD27093B

3 Enrollment

4 Installation

2. Attach the front panel onto the rear panel.

Note: The additional force shall be equal to three times the weight of the equipment but not less than 50N. The equipment and its associated mounting means shall remain secure during the installation. After the installation, the equipment, including any associated mounting plate, shall not be damaged.

1. Secure the rear panel on the wall with four supplied screws.

3. Tighten the screw on the bottom to complete.

Enroll the Peripheral Locally

Enroll the Peripheral with QR Code or Serial No.

1. In the APP, tap the "Enrollment Mode" button on the control panel page to make the control panel enter the enroll- ment status. 2. Push the power switch of the peripheral to ON, and it will be automatically enrolled to the control panel. Note: when the keypad has been enrolled to the control panel A, if there is a control panel B in the enrollment mode around when the power is turned on, the keypad will enroll to the control panel B.

1. In the APP, tap the icon "+" and scan the QR code or enter the serial No. on the peripheral. 2. Push the power switch of the peripheral to ON, and it will be automatically enrolled to the control panel.

1. Remove the screw on the bottom of the keypad. 2. Disassemble the keypad and remove the rear panel. 3. Power on the security control panel. 4. Download and install APP. 4. Log in APP and tap the icon "+". Scan the QR code or enter the control panel serial No. to add the control panel. 5. Enroll the peripheral locally, with OR code, or with serial No..

Remove the screw on the bottom of the keypad. Disassemble the keypad and remove the rear panel.

Scan the QR code on the rear panel of the keypad. Push the power switch to ON.

Check signal strength and select installation place Enter the signal checking mode by operating on the control panel. Signal LED flashes green: Strong. Signal LED flashes orange: Medium. Signal LED flashes red: Weak/Disconnected.

2

CAUTION

IF THE BATTERY COMPARTMENT DOES NOT CLOSE SECURETLY, STOP USING THE PRODUCT AND KEEP IT AWAY FROM CHILDREN.

Buzzer Description Two short beeps: Operation succedded Three short beeps: Operation failed Rapid short beeps: Entry delay Slow short beeps: Exit delay Repeated sound effects: Fire alarm/Medical alarm/Panic alarm/Lid opened alarm

Command5 The keypad command is shown as follows.

Events Codes Notes

Arm

Away arm Password/Tag +

Password/Tag +

Password/Tag +

A short tag swiping (<3 s) is equal to a password.

Only the administrator and the installer have this permission.

Only the administrator and the installer and operators have this permission. The one-push arming is configured on the web client or APP of the control panel. The one-push arming does not require area selection.

1. When the area is selected, the corresponding page will be displayed. 2. Duress passwords can be configured on the control panel.

Duress password +

1. Password/Tag + to enter the relay selection page 2. Use # to select/cancel the relay 3. Use to confirm

Password/Tag + # + Area No. +

Password/Tag + # + Area No. +

Password/Tag + (Hold 3 s)

Password/Tag +

After enabled, the keypad can be armed with or

(Short press)

(Hold 3 s)

Password/Tag + # + Area No. +

Stay arm

Disarm

Area away arm

Area disarm

Area stay arm

Duress password disarm

Disarm

Silence Silence

Alarm

Lock

Relay

Settings

One-push Arm

Delete

Query Query fault 1. Password/Tag + 2. Use # to confirm

Lock/Unlock keypad

Relay output

Settings

One-push Arm

Backspace

Delete all

Fire alarm (Hold 3 s)

(Hold 3 s)

(Hold 3 s)

Hold (3 s) to lock the keypad for 60 s. Hold (3 s) again or wait 60 s to unlock.

Panic alarm

Medical alarm

Arming Process (Enabled/Disabled on Control Panel) Pre-arming Indication: The keypad displays "Waiting for arming" The fault LED turns solid orange

Fault Checking Indication: All faults of the control panel and the zones to be operated will be displayed. You need to use scroll keys to view all faults before next operation. - Away arming: Confirm by - Stay arming: Confirm by - Cancel: The fault LED turns flashing orange

Exit Delay Indication: The keypad displays "Exit delay" The arming LED turns flashing blue and the buzzer indicates exit delay.

Arm Directly Press the or to arm the device. Indication: Armed: arming LED solid blue for 5 s. Buzzer beeps twice. Arming failed: Buzzer beeps three time. Cancel Press the to cancel the arming process. Indication: Armed: Buzzer beeps twice. Arming failed: Buzzer beeps three time.

No Instant Operation The count down is finished. Indication: Armed: arming LED solid blue for 5 s. Buzzer beeps twice. Arming failed: Buzzer beeps three time.

3

6 Specification The keypad technical specification is shown as follows.

4

Reset Hold the Tamper Switch and turn on the power until the LED flashes red 3 times.

Simple Mode Arm The keypad is diarmed. A short tag swiping (<3 s) to away arm. A long tag swiping (3 s) to stay arm.

Disarm The keypad is armed. A short tag swiping (<3 s) to disarm.

Note: 1. A single swiping interval needs to be longer than 3 s. Multiple swipings within 3 s count as one time. 2. Simple mode does not support arming process.

Settings User Management: Add/Edit/Delete users. Tag Managment: Add/Edit/Delete tags. Restore Alarm: Confirm alarm or restore tamper of the control panel. (Only when the control panel supports and enables PD6662. Only installer has this permission.) Company/Telephone: Edit company name and telephone number. Control Panel Lock/Unlock: One-push to lock or unlock the control panel. (Only installer has this permission.) Bypass/Restore Bypass: Bypass/Restore bypass zones.

WE Series WB Series Wireless technology RF frequency 868 MHz 433 MHz RF modulation RF distance 1200 m (open area) 800 m (open area)

LED indicatior

Buzzer Power switch Tamper-proof Serial port Tag reader built-in

Numeric key

System fault display System status display Operation Configuration

Power consumption

Battery type Battery life span Operation temperature Operation humidity Color Installation method Dimension (W H D)

Weight

10C to 55C 10% to 90% White Wall-mounting

With batteries: 348 g Without batteries: 282 g

174.63 mm 109.62 mm 25.25 mm

Standby time more than two years Four CR123 batteries

Quiescent current: 80 uA Max current: 300 mA Voltage: 3 V

Tri-X, two-way communication

2GFSK

Faul

Manualsnet FAQs

If you want to find out how the DS-PK1-LT-WB Hikvision works, you can view and download the Hikvision DS-PK1-LT-WB Keypad User's Manual on the Manualsnet website.

Yes, we have the User's Manual for Hikvision DS-PK1-LT-WB as well as other Hikvision manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The User's Manual should include all the details that are needed to use a Hikvision DS-PK1-LT-WB. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Hikvision DS-PK1-LT-WB Keypad User's Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Hikvision DS-PK1-LT-WB Keypad User's Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Hikvision DS-PK1-LT-WB Keypad User's Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Hikvision DS-PK1-LT-WB Keypad User's Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Hikvision DS-PK1-LT-WB Keypad User's Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.