2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved. About this Manual The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision website (https://www.hikvision.com/). Please use this Manual with the guidance and assistance of professionals trained in supporting the Product.

and other Hikvision's trademarks and logos are the properties of Hikvision in various jurisdictions. Other trademarks and logos mentioned are the properties of their respective owners.

Disclaimer TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED AS IS AND WITH ALL FAULTS AND ERRORS. HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS. YOU ACKNOWLEDGE THAT THE NATURE OF INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED. YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS.

1 Introduction

2 Appearance

3 Indication

This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized European standards listed under the EMC Directive 2014/30/EU, the RE Directive 2014/53/EU, the RoHS Directive 2011/65/EU.

replacement of a battery with an incorrect type that can defeat a safeguard (for example, in the case of some lithium battery types); disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery, that can result in an explosion; leaving a battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas; and a battery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid or gas

Fault

Fire Alarm

Relay Control Disarm Away Arm Stay Arm

Panic Alarm Medical Alarm

Armed/Disarmed Enrollment/Signal Strength

EnrollmentWith Fault

LED Indication Description

Buzzer Description

Armed

Disarmed

Arming Failed

Disarming Failed

Operation completed: Beep twice Operation failed: Beep three times

Solid orange for 3 s and then off

Solid blue for 5 s

Green flashes 2 times

Blue turns Off

Green turns Off

Tampering Alarm

No Alarm

Event Alarm

Note: Event Alarm Priority > Tampering Alarm Priority

Solid red

Off

Flashing red

OffNo Fault

Signal Strength

Find Me

Power On Back Light

-If the keypad is not enrolled to the control panel, the back light is off. -It turns off when there is no key operation for more than 10 s.

Alarm

Tamper Switch

Power Switch

Serial Port

Solid green for 3 s: Strong Solid orange for 3 s: Medium Solid red for 3 s: Weak Flashing red for 3 s: Disconnected

Flashing red and green: Enrolling Green flashes 7 times: Enrolled

Solid green for 1 s: Powered on

Flashing green for 20 s: Operating

-The back light is on by default, you can set the On/Off schedule on the web client of the control panel. Refer to the user manual of control

2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info

2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see:www.recy- clethis.info

1

CAUTION

RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. REPLACEMENT OF A BATTERY WITH AN INCORRECT TYPE THAT CAN DEFEAT A SAFEGUARD.

CAUTION

CHEMICAL BURNING DANGER DO NOT SWALLOW THE BATTERY KEEP NEW AND USED BATTERIES AWAY FROM THE CHILDREN.

IF YOU THINK BATTERIES MIGHT HAVE BEEN SWALLOWED OR PLACED INSIDE ANY PART OF THE BODY, SEEK IMMEDIATE MEDICAL ATTENTION.

CAUTION

DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUC- TIONS AND LOCAL REGULATION.

EN 50131-1:2006+A2:2017 EN 50131-3:2009

EN 50131-5-3:2017 Security Grade(SG) 2

Environmental Class(EC) II

4 Enrollment

5 Installation

2. Attach the front panel onto the rear panel.

Note: The additional force shall be equal to three times the weight of the equipment but not less than 50N. The equipment and its associated mounting means shall remain secure during the installation. After the installation, the equipment, including any associated mounting plate, shall not be damaged.

1. Secure the rear panel on the wall with four supplied screws.

3. Tighten the screw on the bottom to complete the

Enroll the Peripheral Locally

Enroll the Peripheral with QR Code or Serial No.

1. In the APP, tap the "Enrollment Mode" button on the control panel page to make the control panel enter the enroll- ment status. 2. Push the power switch of the peripheral to on, and it will be automatically enrolled to the control panel.

1. In the APP, tap the icon "+"and scan the QR code or enter the serial No. on the peripheral. 2. Push the power switch of the peripheral to on, and it will be automatically enrolled to the control panel.

1. Remove the screw on the bottom of the keypad. 2. Disassemble the keypad and remove the rear panel. 3. Power on the security control panel. 4. Log in the Hik-Connect APP and tap the icon "+" . Scan the QR code or input the control panel serial No. to add the control panel. 5. Enroll the peripheral locally, with OR code, or with serial No..

Note: for re-enrollment, you need to hold the tamper button while powering the peripheral on simultaneously.

Remove the screw on the bottom of the keypad. Disassemble the keypad and remove the rear panel.

Scan the QR code on the rear panel of the keypad. Push the power switch to ON.

Check signal strength and select installation place Enter the signal checking mode by operating on the control panel. Signal LED turns green for 3 s: Strong. Signal LED turns orange for 3 s: Medium. Signal LED turns red for 3 s: Weak. Signal LED flashes red for 3 s: Disconnected.

2

CAUTION

IF THE BATTERY COMPARTMENT DOES NOT CLOSE SECURETLY, STOP USING THE PRODUCT AND KEEP IT AWAY FROM CHILDREN.

7 Specification

Command6 The keypad command is shown as follows.

The keypad technical specification is shown as follows.

Events Codes Notes Away arming for all areas: User password + Away

Away arming for specified area: User password + # + Area No.(1,2.3.4.5.6.7.8.9.010.011.012....) + away

-The keypad does not display area No. greater than 9. -If the area No. is greater than 9, enter " 0XX"for the No."0"indicates tens digits, and "XX"indicates the actual area No. -If the selected area is not related to the keypad,the back light of 0 will flashes three times.

Stay arming for all areas: User password + Stay

Stay arming for specified area: User password + # + Area No.(1,2.3.4.5.6.7.8.9.010.011.012....) + Stay

-The keypad does not display area No. greater than 9. -If the area No. is greater than 9, enter " 0XX"for the No.."0"indicates tens digits, and "XX"indicates the actual area No. -If the selected area is not related to the keypad,the back light of 0 will flashes three times.

Disarming for all areas: User password + Disarm

Disarming for specified area: User password + # + Area No.(1,2.3.4.5.6.7.8.9.010.011.012....) + Disarm

-The keypad does not display area No. greater than 9. -If the area No. is greater than 9, enter " 0XX"for the No.."0"indicates tens digits, and "XX"indicates the actual area No. -If the selected area is not related to the keypad,the back light of 0 will flashes three times.

Clear alarm User Password+Hold Disarm Fire Hold "1/Fire Alarm" for 3 s The Buzzer will beep three times for failure operation. PA Hold "2/Panic Alarm" for 3 s The Buzzer will beep three times for failure operation.

Medical Hold "3/Medical" for 3 s The Buzzer will beep three times for failure operation.

Duress (Duress Code)+disarm You can set the duress code on the web client of the control panel. Refer to the user manual of control panel for details.

Output User Password+Output+relay No.(1,2.3.4.5.6.7.8.9.010.011.012....)+

-If the relay No. is greater than 9, enter " 0XX" for the No.."0"indicates tens digits, and "XX"indicates the actual relay No. - A successful command execution implement an operation "Off" or "On".

Away arm

Stay arm

Disarm

3

Speed 42Kbps Frequency 868.0MHz Method 2GFSK Distance 1200m (open area) Transmition power 13 dbm Tamper switch 1, front and rear panel tamper-proof Wireless module For wireless communication Power switch Power on/off Buzzer 1

Indicator 4: fault (orange), enrollment/signal (red/green), arming(red/green/blue), and alarm (red)

Backlight white Number key 10: 0 to 9 Function key 5: *, #, stay arming, away arming, disarming, and Humidity 10 to 90 Temperature 10 to +55 Color White/Black Dimension(W x H x D) 140 x 86 x 22 mm,

Installation Installation Screw mounting

Power Supply Power Supply 1.5 VDC, four AA baterries, standby time more than two years

Weight Weight without batteries

151 g, and 23 g each battery

Operation Environment

Appearance

Wireless Keypad

RF

Interface

Display

Key

8 Operation Keypad Status

Operation Interval

Keypad Lock

Sleep Status

Working Status

Enrollment Status

Free Status

The keypadwill enter the sleep status while meeting the following conditions: No RFdata transmission No key operation for more than 10 s No keypad tampering alarm No polling No beeping No LED indication

The keypadwill enter the sleep status while meeting the following conditions: RF data transmission key operation keypad tamperingalarm polling Beeping LED indication

While thekeypad is enrolled toa control panel, it enters theenrollment status. Only if the keypad is enrolled, the key operation and status indication take effects.

There is no area related to the keypad. The key and back light do not works.

The interval between theoperations (successful or failed) should bemore than3 s. The continuousoperation of the key should be in 10 s.

The Keypad will be lockedafter 3 to 5 failure authenticationattempts.You can set the lock timeon theweb clientof the control panel

Arming Process Pre-delay Indication: The arming LED turnsflashing blue

Fault Checking Indication: The arming LED turnsflashing orange

Exit Delay Indication: Arming LED turns flashingblue, and the buzzer indicates exit delay.

Arm Directly Press theArm key to armthe device. Indication: Armed: arming LED solidblue for5 s. Buzzer beeps twice. Arming failed:Buzzer beeps three time. Disarm Press theDisarm key to disarmthe device. Indication: Armed: Buzzerbeeps twice. Arming failed:Buzzer beeps three time.

No Instant Operation The countdown isfinished. Indication: Armed: arming LED solidblue for5 s. Buzzer beeps twice. Arming failed:Buzzer beeps three time.

Confirm theoperation bypress theArm key

4</

Manualsnet FAQs

If you want to find out how the DS-PK1-E-WB Hikvision works, you can view and download the Hikvision DS-PK1-E-WB Keypad User's Manual on the Manualsnet website.

Yes, we have the User's Manual for Hikvision DS-PK1-E-WB as well as other Hikvision manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The User's Manual should include all the details that are needed to use a Hikvision DS-PK1-E-WB. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Hikvision DS-PK1-E-WB Keypad User's Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Hikvision DS-PK1-E-WB Keypad User's Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Hikvision DS-PK1-E-WB Keypad User's Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Hikvision DS-PK1-E-WB Keypad User's Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Hikvision DS-PK1-E-WB Keypad User's Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.