- Manuals
- Brands
- Hikvision
- Display
- DS-D4209FI-III
- Installation Guide
Hikvision DS-D4209FI-III Display Installation Guide PDF


Summary of Content for Hikvision DS-D4209FI-III Display Installation Guide PDF
Full-Color LED Display Unit
Installation Guide
Full-Color LED Display Unit Installation Guide
i
Legal Information
2021 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
About this Manual
The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision website (https://www.hikvision.com/). Please use this Manual with the guidance and assistance of professionals trained in supporting the Product.
Trademarks
and other Hikvision's trademarks and logos are the properties of
Hikvision in various jurisdictions. Other trademarks and logos mentioned are the properties of their respective owners.
: The terms HDMI and HDMI High-Definition Multimedia Interface, and the HDMI
Logo are trademarks or registered trademarks of HDMI Licensing Administrator, Inc. in the United States and other countries.
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED "AS IS" AND "WITH ALL FAULTS AND ERRORS". HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS. YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK, VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED. YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF
Full-Color LED Display Unit Installation Guide
ii
PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATTER PREVAILS.
Full-Color LED Display Unit Installation Guide
iii
Contents
Chapter 1 Product Introduction...................................................................................................... 1
1.1 Overview ........................................................................................................................... 1
1.2 Product Components ........................................................................................................ 1
Chapter 2 Rack Installation............................................................................................................. 2
2.1 About Rack ........................................................................................................................ 2
2.2 Install the Rack.................................................................................................................. 2
2.2.1 Precautions ............................................................................................................ 2
2.2.2 Install the Wall-Mounted Rack ............................................................................... 2
2.2.3 Install the Ultrathin Rack...................................................................................... 11
2.2.4 Install the All-in-One Rack .................................................................................... 25
Chapter 3 Cabinet Installation ...................................................................................................... 44
3.1 Introduction .................................................................................................................... 44
3.1.1 About the Cabinet ................................................................................................ 44
3.1.2 Load Capability of the Cabinet ............................................................................. 44
3.2 Install the Cabinets ......................................................................................................... 45
3.2.1 Precautions .......................................................................................................... 45
3.2.2 Stitch Cabinet Frames .......................................................................................... 46
3.2.3 Install Lamp Boards on the Cabinets .................................................................... 49
3.2.4 Adjust Lamp Boards on the Cabinets Horizontally ............................................... 53
3.2.5 Install Protective Shield........................................................................................ 55
3.3 Configuration Example.................................................................................................... 55
3.3.1 Cabling Diagram for 16 Output Interfaces ............................................................ 56
3.3.2 The First Row Power Cord Connection ................................................................. 58
3.3.3 The 16th Row Power Cord Conenction ................................................................. 61
3.3.4 The 5th Row Network Cable Connection.............................................................. 66
3.3.5 Signal Redundancy ............................................................................................... 67
Chapter 4 Software Debugging ..................................................................................................... 70
4.1 Log into the Device ......................................................................................................... 70
4.2 Configure Signal Cables ................................................................................................... 71
Full-Color LED Display Unit Installation Guide
1
Chapter 1 Product Introduction
1.1 Overview
Full-color LED display unit (hereinafter referred to as the device, the product, or the LED) is a high-precision product delivering clear and vivid images. It is featured by wide color gamut, stable performance, long service life, strong environmental adaption, cost effective and little cost to use. The device is applicable to scenes, such as radio and television stations, meeting room display, video security, information display, etc.
1.2 Product Components
An LED control system includes sending and receiving cards. The sending card packages images and sends them to the receiving card. The receiving card unpackages and processes the images, and then displays the images on the LED display unit. The center distance between two pixels is called pixel pitch. The smaller pixel pitch results in higher pixel density per unit area, higher resolution and higher cost. For example, P1.2 indicates 1.2 mm pixel pitch. Our products are rack-mount system, so the installation process mainly involves rack installation and cabinet installation. The following sections describe how to install the rack and cabinet in details.
Full-Color LED Display Unit Installation Guide
2
Chapter 2 Rack Installation
2.1 About Rack
There are three types of racks for installing our full-color LED products: wall-mounted rack, ultrathin rack and all-in-one rack. The wall-mounted rack is used for installing front-maintenance cabinets only. The ultrathin rack and all-in-one rack can be used for installing front-maintenance cabinets and back-maintenance cabinets. The rack models vary depending on the project scale and installation environment, so the rack illustrations in this manual are for reference only.
2.2 Install the Rack
2.2.1 Precautions
Installation personnel must wear protective gear. Take safety measures when working at heights. Make sure that the rack is mounted vertically to the flat ground without tilting or twisting. Check that all structural parts and fasteners are fully mounted without missing. After all the accessories are mounted, clean all the debris in the rack and avoid metal debris
being remained.
2.2.2 Install the Wall-Mounted Rack
The wall-mounted rack is used for installing front-maintenance cabinets only.
Install the Base Frame
Steps
1. Use header corners to connect aluminum extrusion rods from bottom to top.
Full-Color LED Display Unit Installation Guide
3
Figure 2-1 Assemble the Base Frame
Figure 2-2 Base Frame Assembled
2. Use expansion bolts, T-Shaped bolts and fixing plates to fix the base frame onto the wall.
Figure 2-3 Fix the Base Frame onto the Wall
Install the Rack Frame
Steps
1. Use the header corners to connect aluminum extrusion rods to the base frame from left to right.
Full-Color LED Display Unit Installation Guide
4
Figure 2-4 Assemble the Rack Frame
2. Use expansion bolts, T-Shaped bolts and fixing plates to fix the rack frame onto the wall.
Full-Color LED Display Unit Installation Guide
5
Figure 2-5 Fix the Rack Frame onto the Wall
Install Cabinets into the Rack Frame
After base frame and rack frame are well installed, perform the following steps to install the cabinets into the rack frame:
Steps
1. Install the mounting screws through the holes on the front of the cabinet and lock with the floating nuts on the bracket frame.
Full-Color LED Display Unit Installation Guide
6
Figure 2-6 Fix the Screen
Full-Color LED Display Unit Installation Guide
7
Figure 2-7 Screen Fixed
2. Install the cabinets from the center to both sides until cabinets of the first row installed.
Full-Color LED Display Unit Installation Guide
8
Figure 2-8 Screens Fixed
3. Repeat the above steps to install the other cabinets in the above rows. 4. Use a level to measure and ensure that the cabinets are flat and vertical.
Note
Do not fix the screws between the connectors and cabinets too tight for future adjustment. In normal cases, lock out LED lamp boards after they are adjusted horizontally and vertically
because the boards will probably be moved during the installation of other lamp boards. Ensure that the screen is flat and without evident gap. Otherwise, make some adjustments.
Full-Color LED Display Unit Installation Guide
9
Figure 2-9 Screens of the First Row Fixed
Note
For details about cabinet stitching, see Stitch Cabinet Frames. For details about lamp boards installation, see Install Lamp Boards on the Cabinets.
5. Repeat the above steps to install the other cabinets.
Full-Color LED Display Unit Installation Guide
10
Figure 2-10 Screen Installation Finished
Note
Install the device no more than 5 mm away from the wall or other metal racks in case of lamp board drop resulting in electric shock.
After installation, there should be no openings around the LED module. The bottom bracket under the wire outlet position should completely cover the bottom hole only to let the wire out, to prevent the molten material from dripping to the bottom during fire caused by internal failure.
To ensure safety, the installation parts and the wall should support four times the weight of the device.
Full-Color LED Display Unit Installation Guide
11
2.2.3 Install the Ultrathin Rack
The ultrathin racks are used for mounting front-maintenance products and back-maintenance products.
Install the Bottom Chassis
Steps
1. Use header corners to connect aluminum extrusion rods from bottom to top.
Figure 2-11 Assemble the Base Frame Unit
Full-Color LED Display Unit Installation Guide
12
Figure 2-12 Base Frame Unit Assembled
2. Use wedge-locking collector bolts to connect the base frame units.
Figure 2-13 Connect the Base Frame Units
3. Position the anchor bolts into the base frame and tighten the bolts.
Full-Color LED Display Unit Installation Guide
13
Figure 2-14 Assemble the Base Frame
4. Level the bottom chassis and then tighten the bolts.
Figure 2-15 Leveled Bottom Chassis
Install the Rack Frame
Steps
1. Use header corners to connect aluminum extrusion rods from bottom to top.
Full-Color LED Display Unit Installation Guide
14
Figure 2-16 Assemble the Rack Frame Unit
2. Use wedge-locking collector bolts to connect the rack frame units.
Full-Color LED Display Unit Installation Guide
15
Figure 2-17 Connect the Rack Frame Units
3. Align the rack frame to the base chassis and use wedge-locking collector bolts to fix the frames.
Figure 2-18 Align the Rack Frame to the Base Chassis
Full-Color LED Display Unit Installation Guide
16
Figure 2-19 Frames Aligned
Install the Rear Pulling Rods (for Large-scale Project)
Steps
1. Use the wedge-locking collector bolts to fix the rear pulling rods into the rack frame.
Full-Color LED Display Unit Installation Guide
17
Figure 2-20 Fix the Rear Pulling Rods into the Rack frame
Full-Color LED Display Unit Installation Guide
18
Figure 2-21 Rear Pulling Rods Fixed
2. Use the expansion bolts to fix the rear pulling rods onto the bearing wall.
Full-Color LED Display Unit Installation Guide
19
Figure 2-22 Fix the Rear Pulling Rods onto the Bearing Wall
Install the Connectors
The connectors are divided into two parts: customized front joint piece which is used to connect the screens, and back connecting component which is used to connect the rack frame. The following figures list three types of connectors and the positions where the connectors used respectively.
Figure 2-23 Connectors
Full-Color LED Display Unit Installation Guide
20
Figure 2-24 Connectors Installed
Note
Please pay attention to the types of outermost connectors between rack frame and bottom chassis.
Steps
1. Twist the hexagonal screws into the T-Shaped nuts. 2. Insert the T-Shaped nuts into the slots of aluminum extrusion rods, and move the connectors to
the suitable place.
Full-Color LED Display Unit Installation Guide
21
Figure 2-25 Install the Connectors
3. Secure the connectors to the rack frame with screws.
Install Cabinets into the Rack Frame
After the bottom chassis, rack frame and connectors are well installed, perform the following steps to install the cabinets into the rack frame:
Steps
1. Install the first cabinet from the lower middle part. Level and secure the cabinet to the connectors on the rack frame. For screens do not have connectors near the rear, use joint pieces to fix the screen.
Full-Color LED Display Unit Installation Guide
22
Figure 2-26 Fix the Screen with Joint Pieces
Note
Install the cabinets from the bottom to the top, from the middle to the sides. Do not fix the screws between the connectors and cabinets too tight for future adjustment. In normal cases, lock out LED lamp boards after they are adjusted horizontally and vertically
because the boards will probably be moved during the installation of other lamp boards. Ensure that the screen is flat and without evident gap. Otherwise, make some adjustments.
2. Repeat the above steps to install the other cabinets in the lowest row.
Full-Color LED Display Unit Installation Guide
23
Figure 2-27 Fix the Screens
3. Use a level to measure and ensure that the cabinets are flat and vertical.
Note
When there is a deviation in height, simply place a thin iron sheet under the bottom. Do not try to resolve the deviation by hitting the cabinets on the top because it will result in larger deviation later.
4. Repeat the above steps to complete the installation of other cabinets.
Full-Color LED Display Unit Installation Guide
24
Figure 2-28 Screens Fixed
5. Ensure that all the cabinets are flat and vertical and the seams between the cabinets are even. Then tighten the screws to complete the installation.
Full-Color LED Display Unit Installation Guide
25
Figure 2-29 Screen Installation Finished
Note
For details about cabinet stitching, see Stitch Cabinet Frames. For details about lamp boards installation, see Install Lamp Boards on the Cabinets.
2.2.4 Install the All-in-One Rack
The all-in-one racks are used for mounting front-maintenance products and back-maintenance products.
Install the Bottom Chassis
Steps
1. Use header corners to connect aluminum extrusion rods.
Full-Color LED Display Unit Installation Guide
26
Note
It is recommended to assemble the base frame units from bottom to top.
Figure 2-30 Assemble the Base Frame Unit
Full-Color LED Display Unit Installation Guide
27
Figure 2-31 Base Frame Unit Assembled
2. Use wedge-locking collector bolts to connect the base frame units.
Full-Color LED Display Unit Installation Guide
28
Figure 2-32 Connect the Base Frame Units
Full-Color LED Display Unit Installation Guide
29
Figure 2-33 Base Frame Units Connected
3. Repeat the above steps to connect the other base frame units.
Figure 2-34 Base Frame
4. Position the anchor bolts into the base frame and tighten the bolts.
Full-Color LED Display Unit Installation Guide
30
Figure 2-35 Assemble the Base Frame
5. Level the bottom chassis and then tighten the bolts.
Figure 2-36 Leveled Bottom Chassis
Install the Rack Frame
Steps
1. Use header corners to connect aluminum extrusion rods.
Note
It is recommended to assemble the rack frame units from bottom to top.
Full-Color LED Display Unit Installation Guide
31
Figure 2-37 Assemble the Rack Frame Unit
2. Use wedge-locking collector bolts to connect the rack frame units.
Full-Color LED Display Unit Installation Guide
32
Figure 2-38 Connect the Rack Frame Units
3. Repeat the above steps to connect the other rack frame units.
Full-Color LED Display Unit Installation Guide
33
Figure 2-39 Rack Frame
4. Align the rack frame to the base chassis and use wedge-locking collector bolts to fix the frames.
Figure 2-40 Align the Rack Frame to the Base Chassis
Full-Color LED Display Unit Installation Guide
34
Figure 2-41 Frames Aligned
Install the Rear Pulling Rods (for Large-scale Project)
Steps
1. Use the wedge-locking collector bolts to fix the rear pulling rods into the rack frame.
Full-Color LED Display Unit Installation Guide
35
Figure 2-42 Fix the Rear Pulling Rods into the Rack Frame
Figure 2-43 Rear Pulling Rods Fixed
Full-Color LED Display Unit Installation Guide
36
2. Use the expansion bolts to fix the rear pulling rods onto the bearing wall.
Figure 2-44 Fix the Rear Pulling Rods onto the Bearing Wall
Install the Connectors
The connectors are divided into two parts: customized front joint piece which is used to connect the screens, and back connecting component which is used to connect the rack frame. The following figures list three types of connectors and the positions where the connectors used respectively.
Figure 2-45 Connectors
Full-Color LED Display Unit Installation Guide
37
Figure 2-46 Connectors Installed
Note
Please pay attention to the types of outermost connectors between rack frame and bottom chassis.
Steps
1. Twist the hexagonal screws into the screw thread plates. 2. Insert the screw thread plates into the slots of aluminum extrusion rods, and move the
connectors to the suitable place.
Full-Color LED Display Unit Installation Guide
38
Figure 2-47 Install the Connectors
3. Secure the connectors to the rack frame with screws.
Install Cabinets into the Rack Frame
After the bottom chassis, rack frame and connectors are well installed, perform the following steps to install the cabinets into the rack frame:
Steps
1. Install the first cabinet from the lower middle part. Level and secure the cabinet to the connectors on the rack frame. For the screens do not have connectors near the rear, use joint pieces to fix the screen.
Figure 2-48 Fix the Screen with Joint Pieces
Full-Color LED Display Unit Installation Guide
39
Note
Install the cabinets from the bottom to the top, from the middle to the sides. Do not fix the screws between the connectors and cabinets too tight for future adjustment. In normal cases, lock out LED lamp boards after they are adjusted horizontally and vertically
because the boards will probably be moved during the installation of other lamp boards. Ensure that the screen is flat and without evident gap. Otherwise, make some adjustments.
2. Repeat the above steps to install the other cabinets in the lowest row.
Figure 2-49 Fix the Screens
3. Use a level to measure and ensure that the cabinets are flat and vertical.
Note
When there is a deviation in height, simply place a thin iron sheet under the bottom. Do not try to resolve the deviation by hitting the cabinets on the top because it will result in larger deviation later.
4. Repeat the above steps to complete the installation of other cabinets.
Full-Color LED Display Unit Installation Guide
40
Figure 2-50 Screens Fixed
5. Ensure that all the cabinets are flat and vertical and the seams between the cabinets are even. Then tighten the anchor bolts to complete the installation.
Full-Color LED Display Unit Installation Guide
41
Figure 2-51 Screen Installation Finished
Note
For details about cabinet stitching, see Stitch Cabinet Frames. For details about lamp boards installation, see Install Lamp Boards on the Cabinets.
Full-Color LED Display Unit Installation Guide
42
Install the Cover Plates and Door Plates for Bottom Chassis
Steps
1. Use T-Shaped bolts to install the front cover plates and lateral cover plates for bottom chassis respectively.
Figure 2-52 Install the Cover Plates
2. Use T-shaped bolts or door hinge to install the door plates including upper fixing plates, lower fixing plates, left door plates and right door plates.
Full-Color LED Display Unit Installation Guide
43
Figure 2-53 Install the Door Plates
Full-Color LED Display Unit Installation Guide
44
Chapter 3 Cabinet Installation
3.1 Introduction
3.1.1 About the Cabinet
A cabinet is a basic unit for LED engineering installation in which LED modules are neatly mounted on a metal sheet (cast aluminum) box, with a built-in independent receiving card and switching power supply, an engineering installation structure, and independent display.
3.1.2 Load Capability of the Cabinet
Load Capability of Network Interfaces
The following table lists the load capability of a single network interface of the sending card for different screen types.
Table 3-1 Load Capability of Network Interfaces
Screen Type Max Load of a Single Network Interface
P1.2 4 cabinets
P1.4 6 cabinets
P1.5 7 cabinets
P1.6 8 cabinets
P1.8 10 cabinets
P2.5 16 cabinets
Load Capability of Power Cables
Table 3-2 Load Capability of Power Cables
Cabinet Type Max Load of a Single Power Cable
Front-Maintenance Cabinet 15 rows
Follow the instructions below when connecting power cords:
If your video wall has 15 rows of LED displays or fewer, connect a single power cord to each column from the bottom of the lowest display. That is, use one power cord for each column.
If your video wall has more than 15 rows of LED displays, connect two power cords to each
Full-Color LED Display Unit Installation Guide
45
column both from the bottom of the display. That is, use two power cords for each column.
The power cable connection between the cabinets is as follows.
Figure 3-1 Power Cable Connection
3.2 Install the Cabinets
3.2.1 Precautions
Read the following precaution tips before you install the LED screens: Install the LED screens after the decoration construction is completed. Avoid humid or high-pH environment to prevent damage to the LED lamps. Do not expose the device to rain or humid environment to reduce the risk of fire or electric
shock. Electric discharge may last for a short period of time after the power is shut down. Please wait
two minutes after the power is shut down to operate the device. Only use the original power cable delivered with the device. Contact authorized dealer to
purchase power cable with same specifications. Please do not frequently plug and unplug the power cable when the power is on.
Full-Color LED Display Unit Installation Guide
46
3.2.2 Stitch Cabinet Frames
Cabinet Frame Locating
Align two cabinet frames with the locating studs, locating holes and installation holes. Single cabinet frame has 2 locating studs, 2 locating holes and 8 installation holes. The locating studs, locating holes and installation holes are shown as follows.
Figure 3-2 Locating Studs, Locating Holes and Installation Holes
Stitch Cabinet Frames Horizontally
Steps
1. Align the installation holes in the horizontal direction of the two adjacent cabinet frames, and adjust the cabinet frames to the relative level.
Full-Color LED Display Unit Installation Guide
47
Figure 3-3 Align the Cabinet Horizontally
2. Insert the M6 screws into the installation holes.
Figure 3-4 Cabinet Stitching Horizontally
Full-Color LED Display Unit Installation Guide
48
Note
There are 2 installation holes in the installation place, with one to be reserved. You can insert the screws from left to right or from right to left according to the actual
situation. Adjust the flatness of the cabinet frames to ensure the horizontal and vertical alignment
between the cabinet frames.
Stitch Cabinet Frames Vertically
Steps
1. Align the locating studs in the vertical direction of the two adjacent cabinet frames to the locating holes, and adjust the cabinet frames to the relative level.
Figure 3-5 Align the Cabinet Vertically
2. Fix the cabinet frames with the M6 screws.
Full-Color LED Display Unit Installation Guide
49
Figure 3-6 Cabinet Stitching Vertically
Note
There are 4 installation holes in the installation place, with the middle two of them to be reserved.
Insert the screws up to down into the outer installation holes, and down to up into the middle installation holes.
Adjust the flatness of the cabinet frames to ensure the horizontal and vertical alignment between the cabinet frames.
3.2.3 Install Lamp Boards on the Cabinets
Fix the lamp boards on the cabinet frames by magnetic attraction. One cabinet frame is equipped with eight lamp boards.
Full-Color LED Display Unit Installation Guide
50
Figure 3-7 Front and Back of the Lamp Board
Steps
1. Placing the lamp boards on the front of the cabinet frames, align the lamp boards and the edge of the cabinet frames initially.
Full-Color LED Display Unit Installation Guide
51
Figure 3-8 Adsorb Lamp Board
Note
Please align the connector and pay attention to the direction of lamp boards when adsorbing the lamp board.
2. Align and adsorb the lower edge of the lamp boards with the cabinet frames, and then align the locating studs on the lamp boards to the locating holes on the cabinets and adsorbs the remaining three sides of the lamp boards.
Full-Color LED Display Unit Installation Guide
52
Figure 3-9 Install the First Lamp Board
3. The lamp board adsorbs to the cabinet automatically.
Figure 3-10 Lamp Board Installation Finished
Full-Color LED Display Unit Installation Guide
53
4. Optional: If you need to remove the lamp boards, remove the first lamp board by using the LED vacuum pumping tool, and remove other lamp boards with hands.
Figure 3-11 LED Vacuum Pumping Tool
3.2.4 Adjust Lamp Boards on the Cabinets Horizontally
Rotate the screws on the cabinet frames with a word screwdriver to push the adjusting points and lamp boards out until the cabinet is level with others. In the following figure, all the circled points are adjusting points, and there are 9 adjusting points for each cabinet.
Full-Color LED Display Unit Installation Guide
54
Figure 3-12 Points Adjustable on the Front of Cabinet Frames
Full-Color LED Display Unit Installation Guide
55
3.2.5 Install Protective Shield
To reduce the risk of electric shock, install protective shield on the exposed connector after completing LED screen installation.
Figure 3-13 Install Protective Shield
Danger
To reduce the risk of electric shock, install protective shield on the exposed connector after installing LED screen.
The power cable of LED screen should be grounded before powering on the screen. Before installing the protective shield, ensure that the power is cut off.
3.3 Configuration Example
The following two figures show the connection diagrams of P1.2 cabinets. The resolution is 2880 1620. Max load of a single network interface for P1.2 is 4 cabinets. For details, see Load Capability of the Cabinet. If the power consumption of the cabinet is 200 W, 15 cabinets can be divided into one group.
Full-Color LED Display Unit Installation Guide
56
Assign one power cable to each column with 15 rows or less.
Note
The signal cables are marked in green and the power cables in red. The power consumption of a one-to-two power cable is 4000 W. The power consumption of a
one-to-one power cable is 2000 W.
3.3.1 Cabling Diagram for 16 Output Interfaces
Please connect power cords and network cables according to the following diagram. Power cords connection: connect L/N/PE interfaces, and fix the baffle. For details about the first
row and the 16th row power cords connection, see The First Row Power Cord Connection and The 16th Row Power Cord Conenction.
Network cable connection: pass the network cable through the hole and insert into the network interfaces. For details about the 5th row network cable connection, see The 5th Row Network Cable Connection.
Figure 3-14 Power Cords and Network Cables Connection
If the sending card provides 16 output interfaces with 12 network interfaces used, the cabling is shown in the following figure.
Full-Color LED Display Unit Installation Guide
57
Figure 3-15 Cabling Diagram for 16 Output Interfaces
The following figure shows the related cabling diagram on the client.
Full-Color LED Display Unit Installation Guide
58
Figure 3-16 Cabling Diagram for 16 Output Interfaces on the Client
3.3.2 The First Row Power Cord Connection
For the power cord connection of the first row, please remove the original power cord first and then connect an external power cord.
Steps
1. Unfasten the terminal block to remove the original power cord.
Full-Color LED Display Unit Installation Guide
59
Figure 3-17 Before Connecting Power Cord
Full-Color LED Display Unit Installation Guide
60
Figure 3-18 Remove the Original Power Cord
2. Connect an external power cord from the reserved cabling hole on the bottom of the cabinet.
Full-Color LED Display Unit Installation Guide
61
Figure 3-19 Connect External Power Cord from the Bottom
3.3.3 The 16th Row Power Cord Conenction
Because the max load of a single power cord are 15 rows of cabinets, please connect the power cords of the cabinets in the 16th row according to the following diagrams.
Steps
1. Remove the original power cord of cabinet in the 16th row, and meanwhile remove the baffle of the reserved cabling hole.
Full-Color LED Display Unit Installation Guide
62
Figure 3-20 Before Connecting Power Cord of the 16th Row
Full-Color LED Display Unit Installation Guide
63
Figure 3-21 Remove the Original Power Cord and Baffle
Full-Color LED Display Unit Installation Guide
64
Figure 3-22 Back of the Cabinet after Removing the Baffle
2. Connect an external power cord from the reserved cabling hole, and fix the cord on the cabinet.
Full-Color LED Display Unit Installation Guide
65
Figure 3-23 Front View of External Power Cord Connection
Figure 3-24 Rear View of External Power Cord Connection
Full-Color LED Display Unit Installation Guide
66
3.3.4 The 5th Row Network Cable Connection
Because the max load of a single network cable are 4 rows of P1.2 cabinets, please connect the network cables of the cabinets in the 5th row according to the following diagrams.
Steps
1. According to the network cable connection method in Figure 3-25 diagram, connect the network cables from 1 to 4 rows.
2. Connect another network cable to the network interface of the cabinet in the 5th row from the cabling hole on the right side of the bottom.
3. Repeat the above step to finish the network cable connection of other cabinets.
Note
Do not remove the baffle under the network interface. Please connect the network cable from the cabling hole on the right side of the cabinet bottom.
Full-Color LED Display Unit Installation Guide
67
Figure 3-25 Network Cable Connection of the 5th Row
3.3.5 Signal Redundancy
The whole project adopts redundancy mode. Use the 16-interface sending card as an example. Client enables redundancy mode, and then system automatically set even network interfaces (LAN) to be standby. The standby network interfaces do not need connections via client. LANs relationship: LAN 1 corresponds to LAN 2 (standby), LAN 3 to LAN 4, , and LAN 15 to LAN 16. According to on-site project cabling, LAN 1 connects to the first cabinet while LAN 2 connects to the last cabinet of the first group.
Note
When the standby signal cable is connected, the wiring connected from the cabinet to another cabinet needs to be disconnected.
Full-Color LED Display Unit Installation Guide
68
The following figures shows the cabling and the related cabling diagram on the client.
Figure 3-26 Cabling Diagram in Signal Redundancy Mode
Full-Color LED Display Unit Installation Guide
69
Figure 3-27 Cabling Diagram in Signal Redundancy Mode on the Client
Full-Color LED Display Unit Installation Guide
70
Chapter 4 Software Debugging
4.1 Log into the Device
Steps
1. Install and open the LED client.
Figure 4-1 Login Interface
2. Click Online Device to search for online devices. 3. Activate the desired online device.
If the device is not activated, activate the device and set a password. If the device is activated, enter the password to log in. If you forget the password, reset the password using your OA account.
Full-Color LED Display Unit Installation Guide
71
Figure 4-2 Online Device
4. Choose the device and change the IP address and gateway.
Note
Ensure that the device resides on the same network segment with your PC client. Change your PC's IP address to the device's IP address which is displayed on the LED display
controller at intervals.
5. Click Refresh. 6. Choose the device and log in.
Note
The default username is admin, password is admin12345, and port is 8000.
4.2 Configure Signal Cables
Set Screen Scale as, for example, one row with two columns, and select the correct screen type.
Steps
1. Click number one network interface which corresponds to the actual network interface. 2. Click the screen on the right.
Full-Color LED Display Unit Installation Guide
72
3. Hold the mouse and make movements, and the system will connect cables for the signal interfaces according to the movements.
Figure 4-3 Cable Configuration
4. Right click to complete the cable configuration. 5. Repeat the above step
Related manuals for Hikvision DS-D4209FI-III Display Installation Guide
Manualsnet FAQs
If you want to find out how the DS-D4209FI-III Hikvision works, you can view and download the Hikvision DS-D4209FI-III Display Installation Guide on the Manualsnet website.
Yes, we have the Installation Guide for Hikvision DS-D4209FI-III as well as other Hikvision manuals. All you need to do is to use our search bar and find the user manual that you are looking for.
The Installation Guide should include all the details that are needed to use a Hikvision DS-D4209FI-III. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.
The best way to navigate the Hikvision DS-D4209FI-III Display Installation Guide is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.
This Hikvision DS-D4209FI-III Display Installation Guide consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.
You can download Hikvision DS-D4209FI-III Display Installation Guide free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.
To be able to print Hikvision DS-D4209FI-III Display Installation Guide, simply download the document to your computer. Once downloaded, open the PDF file and print the Hikvision DS-D4209FI-III Display Installation Guide as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.